{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T06:47:32Z","timestamp":1787208452320,"version":"build-2736575974"},"reference-count":84,"publisher":"Oxford University Press (OUP)","issue":"1185","license":[{"start":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T00:00:00Z","timestamp":1780531200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000272","name":"National Institute for Health and Care Research","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000272","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Senior Clinical and Practitioner Research","award":["NIHR304554"],"award-info":[{"award-number":["NIHR304554"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Total-body and long axial field-of-view (LAFOV) PET\/CT systems have transformed kinetic modeling from a regional research tool into a whole-body quantitative imaging approach. Unlike static SUV-based imaging, kinetic analysis provides physiologically meaningful parameters describing tracer transport, metabolism, and receptor binding. Historically limited by short axial coverage and low sensitivity, dynamic PET studies were confined to single organs and required invasive arterial sampling. LAFOV scanners, offering axial coverage of up to 2\u2009m and &amp;gt;10-fold sensitivity gains, enable simultaneous multi-organ dynamic acquisitions in a single bed position. This facilitates image-derived input functions, shortened protocols, and ultra-low-dose imaging while maintaining quantitative accuracy. Applications span oncology, neurology, cardiology, infection, and inflammation, with emerging roles in healthy volunteer studies and systemic physiology research. AI-driven methods further enhance feasibility by reducing scan duration, improving parametric image generation, and automating motion correction. Despite challenges in workflow standardization and model selection, advances in acquisition protocols and computational tools position LAFOV PET kinetic modeling as a clinically viable technique. Future developments promise integration into routine practice, enabling precision diagnostics, longitudinal monitoring, and novel tracer evaluation. LAFOV PET thus represents a paradigm shift toward comprehensive, whole-body quantitative imaging in nuclear medicine.<\/jats:p>","DOI":"10.1093\/bjr\/tqag139","type":"journal-article","created":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T16:03:07Z","timestamp":1780588987000},"page":"1662-1671","source":"Crossref","is-referenced-by-count":1,"title":["Kinetic modeling with total body PET\u2014current status and future applications"],"prefix":"10.1093","volume":"99","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-3955-5654","authenticated-orcid":false,"given":"Beverley F","family":"Holman","sequence":"first","affiliation":[{"name":"Department of Nuclear Medicine, Royal Free Hospital , London NW3 2QG,","place":["United Kingdom"]},{"name":"Division of Medicine, UCL , London WC1E 6JF,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neil","family":"Davis","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Royal Free Hospital , London NW3 2QG,","place":["United Kingdom"]},{"name":"Department of Radiation Physics and Protection, Oxford University Hospitals NHS Foundation Trust, Churchill Hospital , Headington, Oxford OX3 7LE,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adnan","family":"Chowdhury","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Royal Free Hospital , London NW3 2QG,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jannat","family":"Khan","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Royal Free Hospital , London NW3 2QG,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hemangini","family":"Natarajan","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Royal Free Hospital , London NW3 2QG,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-7317-3657","authenticated-orcid":false,"given":"Richard","family":"Meades","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Royal Free Hospital , London NW3 2QG,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tamar","family":"Willson","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Royal Free Hospital , London NW3 2QG,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Viraj","family":"Yoosoof","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Royal Free Hospital , London NW3 2QG,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"McCool","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Royal Free Hospital , London NW3 2QG,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,6,4]]},"reference":[{"key":"2026081915314327700_tqag139-B1","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1007\/s00259-018-4153-6","article-title":"Dynamic whole-body PET imaging: principles, potentials and applications","volume":"46","author":"Rahmim","year":"2019","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B2","doi-asserted-by":"publisher","first-page":"3538","DOI":"10.1007\/s00259-023-06299-w","article-title":"Quantitation of dynamic total-body PET imaging: recent developments and future perspectives","volume":"50","author":"Gu","year":"2023","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B3","doi-asserted-by":"publisher","first-page":"015017","DOI":"10.1088\/1361-6560\/ad9ce4","article-title":"An improved Patlak-based Ki parametric imaging approach for clinical18 F-FDG total-body PET","volume":"70","author":"Gu","year":"2024","journal-title":"Phys Med Biol"},{"key":"2026081915314327700_tqag139-B4","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1016\/j.jcmg.2023.06.022","article-title":"Total-body positron emission tomography","volume":"16","author":"Cherry","year":"2023","journal-title":"JACC Cardiovasc Imaging"},{"key":"2026081915314327700_tqag139-B5","doi-asserted-by":"publisher","first-page":"tqag060","DOI":"10.1093\/bjr\/tqag060","article-title":"Long axial field-of-view (LAFOV) PET in the era of multi-parametric imaging and theranostics","volume":"13","author":"Karakatsanis","year":"2026","journal-title":"Br J Radiol"},{"key":"2026081915314327700_tqag139-B6","doi-asserted-by":"publisher","first-page":"476","DOI":"10.2967\/jnumed.121.261972","article-title":"Performance characteristics of the biograph vision quadra PET\/CT system with a long axial field of view using the NEMA NU 2-2018 standard","volume":"63","author":"Prenosil","year":"2022","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B7","doi-asserted-by":"publisher","first-page":"861","DOI":"10.2967\/jnumed.120.250597","article-title":"Performance evaluation of the uEXPLORER total-body PET\/CT scanner based on NEMA NU 2-2018 with additional tests to characterize PET scanners with a long axial field of view","volume":"62","author":"Spencer","year":"2021","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B8","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1007\/s00259-022-05983-7","article-title":"Feasibility of using abbreviated scan protocols with population-based input functions for accurate kinetic modeling of [18F]-FDG datasets from a long axial FOV PET scanner","volume":"50","author":"Sari","year":"2023","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B9","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1186\/s40644-023-00540-3","article-title":"Long-axial field-of-view PET\/CT: perspectives and review of a revolutionary development in nuclear medicine based on clinical experience in over 7000 patients","volume":"23","author":"Alberts","year":"2023","journal-title":"Cancer Imaging"},{"key":"2026081915314327700_tqag139-B10","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1186\/s40658-024-00628-0","article-title":"Validation of image-derived input function using a long axial field of view PET\/CT scanner for two different tracers","volume":"11","author":"Palard-Novello","year":"2024","journal-title":"EJNMMI Phys"},{"key":"2026081915314327700_tqag139-B11","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1186\/s13550-023-01050-w","article-title":"An update on the use of image-derived input functions for human PET studies: new hopes or old illusions?","volume":"13","author":"Volpi","year":"2023","journal-title":"EJNMMI Res"},{"key":"2026081915314327700_tqag139-B12","doi-asserted-by":"publisher","first-page":"714","DOI":"10.2967\/jnumed.123.267036","article-title":"High-temporal-resolution kinetic modeling of lung tumors with dual-blood input function using total-body dynamic PET","volume":"65","author":"Wang","year":"2024","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B13","doi-asserted-by":"publisher","first-page":"5182","DOI":"10.21037\/qims-22-1418","article-title":"Biodistribution and radiation dosimetry of multiple tracers on total-body positron emission tomography\/computed tomography","volume":"13","author":"Li","year":"2023","journal-title":"Quant Imaging Med Surg"},{"key":"2026081915314327700_tqag139-B14","doi-asserted-by":"publisher","first-page":"1154","DOI":"10.2967\/jnumed.122.264810","article-title":"High-temporal-resolution lung kinetic modeling using total-body dynamic PET with time-delay and dispersion corrections","volume":"64","author":"Wang","year":"2023","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B15","doi-asserted-by":"publisher","first-page":"1266","DOI":"10.2967\/jnumed.121.262968","article-title":"Efficient delay correction for total-body PET kinetic modeling using pulse timing methods","volume":"63","author":"Li","year":"2022","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B16","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1186\/s12880-021-00623-2","article-title":"Dynamic 18F-FDG PET imaging of liver lesions: evaluation of a two-tissue compartment model with dual blood input function","volume":"21","author":"Wang","year":"2021","journal-title":"BMC Med Imaging"},{"key":"2026081915314327700_tqag139-B17","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1053\/j.semnuclmed.2024.11.001","article-title":"Role of total body PET\/CT in inflammatory disorders","volume":"55","author":"Zoghi","year":"2025","journal-title":"Semin Nucl Med"},{"key":"2026081915314327700_tqag139-B18","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1038\/jcbfm.1985.87","article-title":"Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations","volume":"5","author":"Patlak","year":"1985","journal-title":"J Cereb Blood Flow Metab"},{"key":"2026081915314327700_tqag139-B19","doi-asserted-by":"publisher","first-page":"740","DOI":"10.1038\/jcbfm.1990.127","article-title":"Graphical analysis of reversible radioligand binding from time\u2014activity measurements applied to [N-11 C-methyl]-(\u2212)-cocaine PET studies in human subjects","volume":"10","author":"Logan","year":"1990","journal-title":"J Cereb Blood Flow Metab"},{"key":"2026081915314327700_tqag139-B20","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1186\/s40658-024-00698-0","article-title":"Bidirectional dynamic frame prediction network for total-body [68Ga]Ga-PSMA-11 and [68Ga]Ga-FAPI-04 PET images","volume":"11","author":"Yang","year":"2024","journal-title":"EJNMMI Phys"},{"key":"2026081915314327700_tqag139-B21","doi-asserted-by":"publisher","first-page":"1997","DOI":"10.1007\/s00259-021-05623-6","article-title":"First results on kinetic modelling and parametric imaging of dynamic 18F-FDG datasets from a long axial FOV PET scanner in oncological patients","volume":"49","author":"Sari","year":"2022","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B22","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1007\/s00259-025-07371-3","article-title":"Exploring the metabolic landscape of lung adenocarcinoma and squamous cell carcinoma: a total-body [18F]FDG PET\/CT approach","volume":"53","author":"Tao","year":"2025","journal-title":"Eur J Nucl Med Mol Imaging."},{"key":"2026081915314327700_tqag139-B23","doi-asserted-by":"publisher","first-page":"eadh7968","DOI":"10.1126\/sciadv.adh7968","article-title":"First-in-human immunoPET imaging of COVID-19 convalescent patients using dynamic total-body PET and a CD8-targeted minibody","volume":"9","author":"Omidvari","year":"2023","journal-title":"Sci Adv"},{"key":"2026081915314327700_tqag139-B24","doi-asserted-by":"publisher","first-page":"2137","DOI":"10.1007\/s00259-024-06620-1","article-title":"Combined whole-body dynamic and static PET\/CT with low-dose [18F]PSMA-1007 in prostate cancer patients","volume":"51","author":"Sachpekidis","year":"2024","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B25","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1007\/s00259-023-06456-1","article-title":"Comparison of parametric imaging and SUV imaging with [68 Ga]Ga-PSMA-11 using dynamic total-body PET\/CT in prostate cancer","volume":"51","author":"Chen","year":"2024","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B26","doi-asserted-by":"publisher","first-page":"5579","DOI":"10.21037\/qims-23-186","article-title":"Quantitative parameters of static imaging and fast kinetics imaging in 18F-FDG total-body PET\/CT for the assessment of histological feature of pulmonary lesions","volume":"13","author":"Meng","year":"2023","journal-title":"Quant Imaging Med Surg"},{"key":"2026081915314327700_tqag139-B27","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/s40644-023-00649-5","article-title":"The role of dynamic, static, and delayed total-body PET imaging in the detection and differential diagnosis of oncological lesions","volume":"24","author":"Wu","year":"2024","journal-title":"Cancer Imaging"},{"key":"2026081915314327700_tqag139-B28","doi-asserted-by":"publisher","first-page":"622","DOI":"10.2967\/jnumed.120.261651","article-title":"Whole-Body parametric imaging of18 F-FDG PET using uEXPLORER with reduced scanning time","volume":"63","author":"Wu","year":"2022","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B29","doi-asserted-by":"publisher","first-page":"960","DOI":"10.2967\/jnumed.122.264988","article-title":"First total-body kinetic modeling and parametric imaging of dynamic68 Ga-FAPI-04 PET in pancreatic and gastric cancer","volume":"64","author":"Chen","year":"2023","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B30","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1007\/s00259-024-06879-4","article-title":"Impact of different parametric Patlak imaging approaches and comparison with a 2-tissue compartment pharmacokinetic model with a long axial field-of-view (LAFOV) PET\/CT in oncological patients","volume":"52","author":"Pan","year":"2025","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B31","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1186\/s13550-024-01080-y","article-title":"Dynamic whole-body [18F]FES PET\/CT increases lesion visibility in patients with metastatic breast cancer","volume":"14","author":"Pedersen","year":"2024","journal-title":"EJNMMI Res"},{"key":"2026081915314327700_tqag139-B32","doi-asserted-by":"publisher","first-page":"973","DOI":"10.2967\/jnumed.124.268706","article-title":"Quantitative total-body imaging of blood flow with high-temporal-resolution early dynamic 18F-FDG PET kinetic modeling","volume":"66","author":"Chung","year":"2025","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B33","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1148\/radiol.2020200028","article-title":"Molecular imaging approaches in dementia","volume":"298","author":"Villemagne","year":"2021","journal-title":"Radiology"},{"key":"2026081915314327700_tqag139-B34","doi-asserted-by":"publisher","first-page":"e075087","DOI":"10.1002\/alz.075087","article-title":"Non-invasive kinetic modeling of [18 F]-florbetaben and [18 F]-PI-2620 with total-body dynamic EXPLORER PET","volume":"19","author":"Holy","year":"2023","journal-title":"Alzheimers Dement"},{"key":"2026081915314327700_tqag139-B35","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1186\/s13550-025-01260-4","article-title":"Kinetic modeling of 18F-PI-2620 binding in the brain using an image-derived input function with total-body PET","volume":"15","author":"Bhattarai","year":"2025","journal-title":"EJNMMI Res"},{"key":"2026081915314327700_tqag139-B36","doi-asserted-by":"publisher","first-page":"1597902","DOI":"10.3389\/fnume.2025.1597902","article-title":"Evaluating image-derived input functions for cerebral [18F]MC225 PET studies","volume":"5","author":"Salvi De Souza","year":"2025","journal-title":"Front Nucl Med"},{"key":"2026081915314327700_tqag139-B37","doi-asserted-by":"publisher","first-page":"120611","DOI":"10.1016\/j.neuroimage.2024.120611","article-title":"Optimization-derived blood input function using a kernel method and its evaluation with total-body PET for brain parametric imaging","volume":"293","author":"Zhu","year":"2024","journal-title":"Neuroimage"},{"key":"2026081915314327700_tqag139-B38","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1007\/s00259-023-06469-w","article-title":"Brain perfusion estimation by Tikhonov model-free deconvolution in a long axial field of view PET\/CT scanner exploring five different PET tracers","volume":"51","author":"Larsson","year":"2024","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B39","doi-asserted-by":"publisher","first-page":"607","DOI":"10.2967\/jnumed.123.266858","article-title":"Total-Body PET\/CT applications in cardiovascular diseases: a perspective document of the SNMMI cardiovascular council","volume":"65","author":"Slart","year":"2024","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B40","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1093\/cvr\/cvaa009","article-title":"The pathogenic role of coronary microvascular dysfunction in the setting of other cardiac or systemic conditions","volume":"116","author":"Konst","year":"2020","journal-title":"Cardiovasc Res"},{"key":"2026081915314327700_tqag139-B41","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1186\/s13550-017-0315-y","article-title":"Semi-quantitative metabolic values on FDG PET\/CT including extracardiac sites of disease as a predictor of treatment course in patients with cardiac sarcoidosis","volume":"7","author":"Ishiyama","year":"2017","journal-title":"EJNMMI Res"},{"key":"2026081915314327700_tqag139-B42","doi-asserted-by":"publisher","first-page":"4985","DOI":"10.1007\/s00259-025-07308-w","article-title":"Total-body 11C-PIB PET\/CT imaging of systemic amyloidosis: inter-organ connectivity in cardiac amyloidosis for prognostic insights","volume":"52","author":"Hong","year":"2025","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B43","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1007\/s13721-025-00515-3","article-title":"Investigation of total-body applicable compartment models for kinetic modeling in total body 15O-water perfusion PET imaging","volume":"14","author":"Rainio","year":"2025","journal-title":"Netw Model Anal Health Inform Bioinforma"},{"key":"2026081915314327700_tqag139-B44","doi-asserted-by":"publisher","first-page":"3500","DOI":"10.1007\/s00259-025-07210-5","article-title":"New compartment model for hepatic blood flow quantification in humans from 15O-water PET images","volume":"52","author":"Rainio","year":"2025","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B45","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1007\/s12149-025-02035-6","article-title":"Pulmonary blood flow quantification in humans from 15O-water PET","volume":"39","author":"Rainio","year":"2025","journal-title":"Ann Nucl Med"},{"key":"2026081915314327700_tqag139-B46","doi-asserted-by":"publisher","first-page":"jnumed.125.271613","DOI":"10.2967\/jnumed.125.271613","article-title":"Organ-specific perfusion response to adenosine as measured using total-body PET","volume":"26","author":"K\u00e4rpijoki","year":"2026","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B47","doi-asserted-by":"publisher","first-page":"2219","DOI":"10.1007\/s00259-023-06242-z","article-title":"First-time rest-stress dynamic whole-body 82Rb-PET imaging using a long axial field-of-view PET\/CT scanner","volume":"50","author":"Caobelli","year":"2023","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B48","doi-asserted-by":"publisher","first-page":"1598","DOI":"10.1016\/j.jacc.2023.08.016","article-title":"Flurpiridaz F-18 PET myocardial perfusion imaging in patients with suspected coronary artery disease","volume":"82","author":"Maddahi","year":"2023","journal-title":"J Am Coll Cardiol"},{"key":"2026081915314327700_tqag139-B49","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s40256-024-00718-5","article-title":"Flurpiridaz F 18: first approval","volume":"25","author":"Keam","year":"2025","journal-title":"Am J Cardiovasc Drugs"},{"key":"2026081915314327700_tqag139-B50","doi-asserted-by":"publisher","first-page":"973","DOI":"10.2967\/jnumed.124.268706","article-title":"Quantitative total-body imaging of blood flow with high-temporal-resolution early dynamic18 F-FDG PET kinetic modeling","volume":"66","author":"Chung","year":"2025","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B51","doi-asserted-by":"publisher","first-page":"2098","DOI":"10.1016\/j.jcmg.2022.05.008","article-title":"Parametric imaging of biologic activity of atherosclerosis using dynamic whole-body positron emission tomography","volume":"15","author":"Derlin","year":"2022","journal-title":"JACC Cardiovasc Imaging"},{"key":"2026081915314327700_tqag139-B52","doi-asserted-by":"publisher","first-page":"416","DOI":"10.2967\/jnumed.122.264550","article-title":"Exploring vessel wall biology in vivo by ultrasensitive total-body PET","volume":"64","author":"Derlin","year":"2023","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B53","doi-asserted-by":"publisher","first-page":"1919","DOI":"10.1007\/s12350-021-02608-8","article-title":"Cardiac amyloidosis characterization by kinetic model fitting on [18F]florbetaben PET images","volume":"29","author":"Santarelli","year":"2022","journal-title":"J Nucl Cardiol"},{"key":"2026081915314327700_tqag139-B54","doi-asserted-by":"publisher","first-page":"6033","DOI":"10.3390\/jcm12186033","article-title":"Highlighting fibroblasts activation in fibrosis: the state-of-the-art fibroblast activation protein inhibitor PET imaging in cardiovascular diseases","volume":"12","author":"Cui","year":"2023","journal-title":"J Clin Med"},{"key":"2026081915314327700_tqag139-B55","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1016\/j.jacc.2017.11.024","article-title":"Myocardial inflammation predicts remodeling and neuroinflammation after myocardial infarction","volume":"71","author":"Thackeray","year":"2018","journal-title":"J Am Coll Cardiol"},{"key":"2026081915314327700_tqag139-B56","doi-asserted-by":"publisher","first-page":"7984","DOI":"10.7150\/thno.61423","article-title":"Molecular imaging of inflammation crosstalk along the cardio-renal axis following acute myocardial infarction","volume":"11","author":"Werner","year":"2021","journal-title":"Theranostics"},{"key":"2026081915314327700_tqag139-B57","doi-asserted-by":"publisher","first-page":"1821","DOI":"10.2967\/jnumed.123.265723","article-title":"Total-Body multiparametric PET quantification of18 F-FDG delivery and metabolism in the study of coronavirus disease 2019 recovery","volume":"64","author":"Wang","year":"2023","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B58","doi-asserted-by":"publisher","first-page":"1875","DOI":"10.3390\/cells12141875","article-title":"Flow cytometry: the next revolution","volume":"12","author":"Robinson","year":"2023","journal-title":"Cells"},{"key":"2026081915314327700_tqag139-B59","first-page":"2518","article-title":"High-temporal resolution kinetic modeling on total-body PET differentiates the hepatic interstitial space in nonalcoholic fatty liver disease and healthy subjects","volume":"63","author":"Tran","year":"2022","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B60","doi-asserted-by":"publisher","first-page":"2167","DOI":"10.1007\/s00259-025-07563-x","article-title":"Clinical evaluation of dynamic [18F]FDG PET imaging to distinguish infection from inflammation in fracture-related infections","volume":"53","author":"Van Rijsewijk","year":"2026","journal-title":"Eur J Nucl Med Mol Imaging."},{"key":"2026081915314327700_tqag139-B61","doi-asserted-by":"publisher","first-page":"2373","DOI":"10.1007\/s00259-020-05173-3","article-title":"Ultra-low-activity total-body dynamic PET imaging allows equal performance to full-activity PET imaging for investigating kinetic metrics of 18F-FDG in healthy volunteers","volume":"48","author":"Liu","year":"2021","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B62","doi-asserted-by":"publisher","first-page":"4722499","DOI":"10.1155\/2023\/4722499","article-title":"Dynamic total-body PET\/CT imaging reveals kinetic distribution of 68Ga-DOTATATE in normal organs","volume":"2023","author":"Yin","year":"2023","journal-title":"Contrast Media Mol Imaging"},{"key":"2026081915314327700_tqag139-B63","doi-asserted-by":"publisher","first-page":"738","DOI":"10.2967\/jnumed.119.238113","article-title":"Total-body quantitative parametric imaging of early kinetics of18 F-FDG","volume":"62","author":"Feng","year":"2021","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B64","doi-asserted-by":"publisher","first-page":"2493","DOI":"10.1007\/s00259-021-05500-2","article-title":"Short-time total-body dynamic PET imaging performance in quantifying the kinetic metrics of 18F-FDG in healthy volunteers","volume":"49","author":"Liu","year":"2022","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B65","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1186\/s40644-024-00684-w","article-title":"Extracting value from total-body PET\/CT image data - the emerging role of artificial intelligence","volume":"24","author":"Shiyam Sundar","year":"2024","journal-title":"Cancer Imaging"},{"key":"2026081915314327700_tqag139-B66","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1053\/j.semnuclmed.2024.09.002","article-title":"Total-Body PET\/CT: a role of artificial intelligence?","volume":"55","author":"Zhang","year":"2025","journal-title":"Semin Nucl Med"},{"key":"2026081915314327700_tqag139-B67","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1016\/j.cpet.2021.06.009","article-title":"Total-body PET kinetic modeling and potential opportunities using deep learning","volume":"16","author":"Wang","year":"2021","journal-title":"PET Clin"},{"key":"2026081915314327700_tqag139-B68","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1186\/s40658-023-00579-y","article-title":"Combining deep learning with a kinetic model to predict dynamic PET images and generate parametric images","volume":"10","author":"Liang","year":"2023","journal-title":"EJNMMI Phys"},{"key":"2026081915314327700_tqag139-B69","doi-asserted-by":"publisher","first-page":"1448","DOI":"10.1007\/s00259-024-07012-1","article-title":"A deep learning method for total-body dynamic PET imaging with dual-time-window protocols","volume":"52","author":"Ding","year":"2025","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B70","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1109\/TRPMS.2023.3243576","article-title":"Generation of whole-body FDG parametric Ki images from static PET images using deep learning","volume":"7","author":"Miao","year":"2023","journal-title":"IEEE Trans Radiat Plasma Med Sci"},{"key":"2026081915314327700_tqag139-B71","doi-asserted-by":"publisher","first-page":"2482","DOI":"10.1007\/s00259-022-05731-x","article-title":"Parametric image generation with the uEXPLORER total-body PET\/CT system through deep learning","volume":"49","author":"Huang","year":"2022","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B72","doi-asserted-by":"publisher","first-page":"4048","DOI":"10.1007\/s00259-022-05867-w","article-title":"Direct inference of Patlak parametric images in whole-body PET\/CT imaging using convolutional neural networks","volume":"49","author":"Zaker","year":"2022","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B73","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1007\/s00259-022-06003-4","article-title":"A deep neural network for parametric image reconstruction on a large axial field-of-view PET","volume":"50","author":"Li","year":"2023","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B74","doi-asserted-by":"publisher","first-page":"3465","DOI":"10.1007\/s00259-025-07182-6","article-title":"Impact of deep learning denoising on kinetic modelling for low-dose dynamic PET: application to single- and dual-tracer imaging protocols","volume":"52","author":"Muller","year":"2025","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B75","doi-asserted-by":"publisher","first-page":"102524","DOI":"10.1016\/j.media.2022.102524","article-title":"Unsupervised inter-frame motion correction for whole-body dynamic PET using convolutional long short-term memory in a convolutional neural network","volume":"80","author":"Guo","year":"2022","journal-title":"Med Image Anal"},{"key":"2026081915314327700_tqag139-B76","doi-asserted-by":"publisher","first-page":"3512","DOI":"10.1109\/TMI.2023.3290003","article-title":"MCP-Net: introducing Patlak loss optimization to whole-body dynamic PET inter-frame motion correction","volume":"27","author":"Guo","year":"2023","journal-title":"IEEE Trans Med Imaging"},{"key":"2026081915314327700_tqag139-B77","doi-asserted-by":"publisher","first-page":"3819587","DOI":"10.1155\/2023\/3819587","article-title":"Segmentation of dynamic total-body [18F]-FDG PET images using unsupervised clustering","volume":"2023","author":"Jaakkola","year":"2023","journal-title":"Int J Biomed Imaging"},{"key":"2026081915314327700_tqag139-B78","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1186\/s40658-022-00492-w","article-title":"Comparison between a dual-time-window protocol and other simplified protocols for dynamic total-body 18F-FDG PET imaging","volume":"9","author":"Wang","year":"2022","journal-title":"EJNMMI Phys"},{"key":"2026081915314327700_tqag139-B79","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1186\/s13550-025-01277-9","article-title":"Model selection for dynamic PET compartmental modelling of 18F-FDG uptake using a long axial field-of-view PET scanner with delay and motion correction","volume":"15","author":"Moradi","year":"2025","journal-title":"EJNMMI Res"},{"key":"2026081915314327700_tqag139-B80","doi-asserted-by":"publisher","first-page":"1274","DOI":"10.2967\/jnumed.121.262668","article-title":"Total-body PET multiparametric imaging of cancer using a voxelwise strategy of compartmental modeling","volume":"63","author":"Wang","year":"2022","journal-title":"J Nucl Med"},{"key":"2026081915314327700_tqag139-B81","doi-asserted-by":"publisher","first-page":"3215","DOI":"10.1007\/s00259-022-05747-3","article-title":"Abbreviated scan protocols to capture 18F-FDG kinetics for long axial FOV PET scanners","volume":"49","author":"Viswanath","year":"2022","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B82","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1007\/s00259-023-06526-4","article-title":"Dynamic total-body PET\/CT imaging with reduced acquisition time shows acceptable performance in quantification of [18F]FDG tumor kinetic metrics","volume":"51","author":"Liu","year":"2024","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026081915314327700_tqag139-B83","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1053\/j.semnuclmed.2021.10.002","article-title":"Parametric imaging with dynamic PET for oncological applications: protocols, interpretation, current applications and limitations for clinical use","volume":"52","author":"Dimitrakopoulou-Strauss","year":"2022","journal-title":"Semin Nucl Med"},{"key":"2026081915314327700_tqag139-B84","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1053\/j.semnuclmed.2024.05.008","article-title":"Total body PET-CT protocols in oncology","volume":"55","author":"Dimitrakopoulou-Strauss","year":"2025","journal-title":"Semin Nucl Med"}],"container-title":["British Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/bjr\/advance-article-pdf\/doi\/10.1093\/bjr\/tqag139\/68475692\/tqag139.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/99\/1185\/1662\/68475692\/tqag139.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/99\/1185\/1662\/68475692\/tqag139.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:31:47Z","timestamp":1787167907000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjr\/article\/99\/1185\/1662\/8702450"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,4]]},"references-count":84,"journal-issue":{"issue":"1185","published-online":{"date-parts":[[2026,6,4]]},"published-print":{"date-parts":[[2026,9,1]]}},"URL":"https:\/\/doi.org\/10.1093\/bjr\/tqag139","relation":{},"ISSN":["0007-1285","1748-880X"],"issn-type":[{"value":"0007-1285","type":"print"},{"value":"1748-880X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,9]]},"published":{"date-parts":[[2026,6,4]]}}}