{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T08:22:00Z","timestamp":1794990120622,"version":"4.9.1"},"reference-count":71,"publisher":"Oxford University Press (OUP)","issue":"1188","license":[{"start":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T00:00:00Z","timestamp":1785283200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,12,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>To provide a structured and critical overview of the technical foundations, diagnostic performance, and clinical applicability of zero echo time\/black-bone MRI (ZTE\/BB) and dual-energy CT virtual non-calcium imaging (DECT-VNCa) in skeletal oncology, with the aim of clarifying their respective roles and potential complementarity within contemporary imaging workflows.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A structured narrative review of peer-reviewed literature published between 2010 and 2025 was conducted, focusing on technical principles, methodological quality, lesion-level diagnostic performance, and clinical applications of ZTE\/BB MRI and DECT-VNCa in oncologic bone disease. Evidence was synthesized according to anatomical region and diagnostic task, including staging, assessment of cortical integrity, marrow infiltration, and treatment response. ZTE\/BB MRI demonstrates high-fidelity depiction of cortical bone, utility in PET\/MR attenuation correction, and growing relevance in radiotherapy planning and skeletal tumor assessment. DECT-VNCa enables sensitive and reproducible evaluation of bone marrow involvement, improving detection of CT-occult disease and providing quantitative biomarkers correlated with cellularity and therapy-related changes. Direct head-to-head comparisons remain limited, and variability in acquisition protocols and quantitative thresholds persists across platforms.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results and Conclusions<\/jats:title>\n                    <jats:p>ZTE\/BB MRI and DECT-VNCa should be considered complementary rather than competing techniques in skeletal oncology imaging. ZTE\/BB MRI is particularly suited for radiation-free assessment of cortical integrity and structurally relevant disease, whereas DECT-VNCa offers rapid, quantitative characterization of marrow involvement. An integrated, task-oriented use of these modalities may improve diagnostic coherence across different anatomical sites and phases of the oncologic pathway. Further prospective and standardized studies are required to harmonize protocols and define their optimal clinical integration.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/bjr\/tqag172","type":"journal-article","created":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T15:12:49Z","timestamp":1785337969000},"page":"2439-2453","source":"Crossref","is-referenced-by-count":0,"title":["Zero echo time MRI and dual-energy CT virtual non-calcium imaging in skeletal oncology: a critical evidence-based review"],"prefix":"10.1093","volume":"99","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-2421-1909","authenticated-orcid":false,"given":"Luca","family":"Marinelli","sequence":"first","affiliation":[{"name":"Department of Precision Medicine, University of Campania \u201cL. Vanvitelli\u201d , Naples 80138, Piazzetta Miraglia,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Chiara","family":"Brunese","sequence":"additional","affiliation":[{"name":"Department of Precision Medicine, University of Campania \u201cL. Vanvitelli\u201d , Naples 80138, Piazzetta Miraglia,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fiammetta","family":"Cappabianca","sequence":"additional","affiliation":[{"name":"Medicine and Surgery MedTech, Campus Bio-Medico University , Rome 00128, Via Alvaro Del Portillo,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicola Maria","family":"Tarantino","sequence":"additional","affiliation":[{"name":"Department of Precision Medicine, University of Campania \u201cL. Vanvitelli\u201d , Naples 80138, Piazzetta Miraglia,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Russo","sequence":"additional","affiliation":[{"name":"Department of Precision Medicine, University of Campania \u201cL. Vanvitelli\u201d , Naples 80138, Piazzetta Miraglia,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alfonso","family":"Reginelli","sequence":"additional","affiliation":[{"name":"Department of Precision Medicine, University of Campania \u201cL. Vanvitelli\u201d , Naples 80138, Piazzetta Miraglia,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Salvatore","family":"Cappabianca","sequence":"additional","affiliation":[{"name":"Department of Precision Medicine, University of Campania \u201cL. Vanvitelli\u201d , Naples 80138, Piazzetta Miraglia,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,7,29]]},"reference":[{"key":"2026111802534741500_tqag172-B1","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1148\/radiol.2019181949","article-title":"Guidelines for acquisition, interpretation, and reporting of whole-body MRI in myeloma: myeloma response assessment and diagnosis system (MY-RADS)","volume":"291","author":"Messiou","year":"2019","journal-title":"Radiology"},{"key":"2026111802534741500_tqag172-B2","doi-asserted-by":"publisher","first-page":"e302","DOI":"10.1016\/S1470-2045(19)30309-2","article-title":"International myeloma working group consensus recommendations on imaging in monoclonal plasma cell disorders","volume":"20","author":"Hillengass","year":"2019","journal-title":"Lancet Oncol"},{"key":"2026111802534741500_tqag172-B3","doi-asserted-by":"publisher","first-page":"2519","DOI":"10.1016\/j.ejca.2014.07.002","article-title":"Monitoring the response of bone metastases to treatment with magnetic resonance imaging and nuclear medicine techniques","volume":"50","author":"Lecouvet","year":"2014","journal-title":"Eur J Cancer"},{"key":"2026111802534741500_tqag172-B4","doi-asserted-by":"publisher","first-page":"4093","DOI":"10.3390\/cancers13164093","article-title":"Comprehensive updates in the role of imaging for multiple myeloma","volume":"13","author":"Lee","year":"2021","journal-title":"Cancers (Basel)"},{"key":"2026111802534741500_tqag172-B5","doi-asserted-by":"publisher","first-page":"980","DOI":"10.2214\/AJR.08.1633","article-title":"Whole-body MRI versus PET in assessment of multiple myeloma","volume":"192","author":"Shortt","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"2026111802534741500_tqag172-B6","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1007\/s00256-021-03895-2","article-title":"Imaging of treatment response and minimal residual disease in multiple myeloma: WB-MRI and PET\/CT","volume":"51","author":"Lecouvet","year":"2022","journal-title":"Skeletal Radiol"},{"key":"2026111802534741500_tqag172-B7","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1002\/mrm.22799","article-title":"MRI with zero echo time: hard-versus sweep-pulse excitation","volume":"66","author":"Weiger","year":"2011","journal-title":"Magn Reson Med"},{"key":"2026111802534741500_tqag172-B8","doi-asserted-by":"publisher","first-page":"1398","DOI":"10.1148\/rg.220029","article-title":"Zero echo time musculoskeletal MRI: technique, optimization, applications, and pitfalls","volume":"42","author":"Ayd\u0131ng\u00f6z","year":"2022","journal-title":"Radiographics"},{"key":"2026111802534741500_tqag172-B9","doi-asserted-by":"publisher","first-page":"1562","DOI":"10.3174\/ajnr.A6181","article-title":"Zero TE MRI for craniofacial bone imaging","volume":"40","author":"Lu","year":"2019","journal-title":"AJNR Am J Neuroradiol"},{"key":"2026111802534741500_tqag172-B10","doi-asserted-by":"publisher","first-page":"960","DOI":"10.1148\/radiol.2017170257","article-title":"Zero echo time imaging of the shoulder","volume":"286","author":"Breighner","year":"2018","journal-title":"Radiology"},{"key":"2026111802534741500_tqag172-B11","doi-asserted-by":"publisher","first-page":"417","DOI":"10.2967\/jnumed.114.149997","article-title":"Clinical evaluation of zero-echo-time MR imaging for cranial bones","volume":"56","author":"Delso","year":"2015","journal-title":"J Nucl Med"},{"key":"2026111802534741500_tqag172-B12","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1259\/bjr\/19389411","article-title":"\u201cBlack bone\u201d MRI for craniofacial imaging","volume":"85","author":"Eley","year":"2012","journal-title":"Br J Radiol"},{"key":"2026111802534741500_tqag172-B13","doi-asserted-by":"publisher","first-page":"W200","DOI":"10.2214\/AJR.19.21746","article-title":"MRI protocol for craniosynostosis using black bone MRI","volume":"213","author":"Tan","year":"2019","journal-title":"AJR Am J Roentgenol"},{"key":"2026111802534741500_tqag172-B14","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1007\/s00234-020-02508-7","article-title":"Automated 3D MRI rendering using ZTE","volume":"63","author":"Eley","year":"2021","journal-title":"Neuroradiology"},{"key":"2026111802534741500_tqag172-B15","doi-asserted-by":"publisher","first-page":"228","DOI":"10.21037\/qims-20-601","article-title":"Black bone imaging in paediatric craniofacial CT replacement","volume":"11","author":"Low","year":"2021","journal-title":"Quant Imaging Med Surg"},{"key":"2026111802534741500_tqag172-B16","doi-asserted-by":"publisher","first-page":"6451","DOI":"10.3390\/jcm11216451","article-title":"Imaging in craniofacial disorders with BB\/ZTE MRI sequences","volume":"11","author":"Ganau","year":"2022","journal-title":"J Clin Med"},{"key":"2026111802534741500_tqag172-B17","doi-asserted-by":"publisher","first-page":"1507","DOI":"10.1007\/s00256-020-03437-7","article-title":"Value of ZTE MRI and CT in bone tumors","volume":"49","author":"Xu","year":"2020","journal-title":"Skeletal Radiol"},{"key":"2026111802534741500_tqag172-B18","doi-asserted-by":"publisher","first-page":"e331","DOI":"10.1016\/j.crad.2024.01.012","article-title":"Utility of zero echo time for neoplasia, infection, inflammation","volume":"79","author":"Chauhan","year":"2024","journal-title":"Clin Radiol"},{"key":"2026111802534741500_tqag172-B19","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1148\/rg.2016150232","article-title":"Material separation using dual-energy CT","volume":"36","author":"Patino","year":"2016","journal-title":"Radiographics"},{"key":"2026111802534741500_tqag172-B20","doi-asserted-by":"publisher","first-page":"493","DOI":"10.2214\/AJR.19.21095","article-title":"Dual-energy CT in musculoskeletal imaging","volume":"213","author":"Rajiah","year":"2019","journal-title":"AJR Am J Roentgenol"},{"key":"2026111802534741500_tqag172-B21","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1186\/s41747-021-00228-y","article-title":"Virtual non-calcium DECT: clinical applications","volume":"5","author":"D\u2019Angelo","year":"2021","journal-title":"Eur Radiol Exp"},{"key":"2026111802534741500_tqag172-B22","doi-asserted-by":"publisher","first-page":"671","DOI":"10.3390\/diagnostics12030671","article-title":"AI-assisted DECT VNCa marrow imaging of the spine","volume":"12","author":"Fervers","year":"2022","journal-title":"Diagnostics"},{"key":"2026111802534741500_tqag172-B23","doi-asserted-by":"publisher","first-page":"1038","DOI":"10.1007\/s11547-024-01827-6","article-title":"Dual-energy CT in musculoskeletal imaging","volume":"129","author":"Albano","year":"2024","journal-title":"Radiol Med"},{"key":"2026111802534741500_tqag172-B24","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1001\/jama.2017.19163","article-title":"Preferred reporting items for a systematic review and meta-analysis of diagnostic test accuracy studies: the PRISMA-DTA statement","volume":"319","author":"Cohen","year":"2018","journal-title":"JAMA"},{"key":"2026111802534741500_tqag172-B25","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.ejrad.2017.08.005","article-title":"Meta-analysis of DECT VNCa for bone marrow edema","volume":"95","author":"Li","year":"2017","journal-title":"Eur J Radiol"},{"key":"2026111802534741500_tqag172-B26","doi-asserted-by":"publisher","first-page":"4182","DOI":"10.1007\/s00330-018-5411-5","article-title":"Diagnostic performance of DECT for BME","volume":"28","author":"Suh","year":"2018","journal-title":"Eur Radiol"},{"key":"2026111802534741500_tqag172-B27","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1148\/radiol.10091230","article-title":"VNCa DECT detecting traumatic BME","volume":"256","author":"Pache","year":"2010","journal-title":"Radiology"},{"key":"2026111802534741500_tqag172-B28","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.1007\/s00256-014-1913-7","article-title":"DECT VNCa bone bruises in knees","volume":"43","author":"Ai","year":"2014","journal-title":"Skeletal Radiol"},{"key":"2026111802534741500_tqag172-B29","doi-asserted-by":"publisher","first-page":"1109","DOI":"10.1016\/j.ejrad.2015.03.003","article-title":"DECT VNCa grading reliability knee BME","volume":"84","author":"Cao","year":"2015","journal-title":"Eur J Radiol"},{"key":"2026111802534741500_tqag172-B30","doi-asserted-by":"publisher","first-page":"815.e1","DOI":"10.1016\/j.crad.2019.06.020","article-title":"DECT VNCa detection of BME in knee joints","volume":"74","author":"Wang","year":"2019","journal-title":"Clin Radiol"},{"key":"2026111802534741500_tqag172-B31","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1007\/s00330-019-06304-7","article-title":"Color-coded VNCa DECT for knee trauma BME","volume":"30","author":"Booz","year":"2020","journal-title":"Eur Radiol"},{"key":"2026111802534741500_tqag172-B32","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1177\/0284185119877343","article-title":"DECT detection of BME with MRI reference","volume":"61","author":"Bj\u00f6rkman","year":"2020","journal-title":"Acta Radiol"},{"key":"2026111802534741500_tqag172-B33","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1007\/s00256-020-03646-y","article-title":"DECT for BME detection: meta-analysis","volume":"50","author":"Wilson","year":"2021","journal-title":"Skeletal Radiol"},{"key":"2026111802534741500_tqag172-B34","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.clinimag.2020.09.013","article-title":"VNCa DECT for ankle BME","volume":"69","author":"Foti","year":"2021","journal-title":"Clin Imaging"},{"key":"2026111802534741500_tqag172-B35","doi-asserted-by":"publisher","first-page":"4098","DOI":"10.1007\/s00330-020-06775-z","article-title":"Hip BME: DECT vs MRI","volume":"30","author":"Foti","year":"2020","journal-title":"Eur Radiol"},{"key":"2026111802534741500_tqag172-B36","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1148\/radiol.2021203624","article-title":"DECT for vertebral fracture-associated BME: meta-analysis","volume":"300","author":"Sherbaf","year":"2021","journal-title":"Radiology"},{"key":"2026111802534741500_tqag172-B37","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1148\/radiol.2017170281","article-title":"DECT VNCa diagnosis of MM infiltration","volume":"286","author":"Kosmala","year":"2018","journal-title":"Radiology"},{"key":"2026111802534741500_tqag172-B38","doi-asserted-by":"publisher","first-page":"5083","DOI":"10.1007\/s00330-018-5551-7","article-title":"DECT quantitative patterns of MM infiltration","volume":"28","author":"Kosmala","year":"2018","journal-title":"Eur Radiol"},{"key":"2026111802534741500_tqag172-B39","doi-asserted-by":"publisher","first-page":"W324","DOI":"10.2214\/AJR.14.12613","article-title":"DECT virtual calcium subtraction in MM","volume":"204","author":"Thomas","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"2026111802534741500_tqag172-B40","doi-asserted-by":"publisher","first-page":"e147","DOI":"10.1016\/j.acra.2021.02.027","article-title":"DECT in MM: comparison with PET\/CT and MRI","volume":"29","author":"Werner","year":"2022","journal-title":"Acad Radiol"},{"key":"2026111802534741500_tqag172-B41","doi-asserted-by":"publisher","first-page":"734819","DOI":"10.3389\/fonc.2021.734819","article-title":"Radiotherapy response assessment in MM: DECT VNCa","volume":"11","author":"Fervers","year":"2021","journal-title":"Front Oncol"},{"key":"2026111802534741500_tqag172-B42","doi-asserted-by":"publisher","first-page":"109502","DOI":"10.1016\/j.ejrad.2020.109502","article-title":"VNCa DECT predicts metabolic MM activity vs FDG PET","volume":"135","author":"Fervers","year":"2020","journal-title":"Eur J Radiol"},{"key":"2026111802534741500_tqag172-B43","doi-asserted-by":"publisher","first-page":"5731","DOI":"10.1002\/mp.15934","article-title":"Deep learning VNCa MM imaging","volume":"49","author":"Gong","year":"2022","journal-title":"Med Phys"},{"key":"2026111802534741500_tqag172-B44","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1002\/jmri.28843","article-title":"ZTE MRI in the musculoskeletal system","volume":"59","author":"Fujisaki","year":"2024","journal-title":"J Magn Reson Imaging"},{"key":"2026111802534741500_tqag172-B45","doi-asserted-by":"publisher","first-page":"1","DOI":"10.13104\/imri.2024.0009","article-title":"UTE and ZTE MRI and clinical applications","volume":"28","author":"More","year":"2024","journal-title":"Investig Magn Reson Imaging"},{"key":"2026111802534741500_tqag172-B46","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1007\/s10334-015-0510-8","article-title":"UTE\/ZTE MRI at 7T","volume":"29","author":"Larson","year":"2016","journal-title":"Magma"},{"key":"2026111802534741500_tqag172-B47","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.bone.2013.01.024","article-title":"Bone microstructure with ZTE MRI","volume":"54","author":"Weiger","year":"2013","journal-title":"Bone"},{"key":"2026111802534741500_tqag172-B48","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1002\/mrm.25593","article-title":"Zero TE MR bone imaging of the head","volume":"75","author":"Wiesinger","year":"2016","journal-title":"Magn Reson Med"},{"key":"2026111802534741500_tqag172-B49","doi-asserted-by":"publisher","first-page":"1307","DOI":"10.1007\/s00256-021-03987-2","article-title":"CT-like MRI ZTE knee osseous assessment","volume":"51","author":"Bharadwaj","year":"2022","journal-title":"Skeletal Radiol"},{"key":"2026111802534741500_tqag172-B50","doi-asserted-by":"publisher","first-page":"928","DOI":"10.1097\/BRS.0000000000002485","article-title":"Diagnostic accuracy of ZTE MRI for foraminal stenosis","volume":"43","author":"Argentieri","year":"2018","journal-title":"Spine (Phila Pa 1976)"},{"key":"2026111802534741500_tqag172-B51","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1002\/jmri.27970","article-title":"MRI vs CT for 3D bone imaging","volume":"56","author":"Florkow","year":"2022","journal-title":"J Magn Reson Imaging"},{"key":"2026111802534741500_tqag172-B52","doi-asserted-by":"publisher","first-page":"39","DOI":"10.25259\/JCIS_15_2025","article-title":"Black bone MRI in clinical practice: systematic review","volume":"15","author":"Jijo","year":"2025","journal-title":"J Clin Imaging Sci"},{"key":"2026111802534741500_tqag172-B53","doi-asserted-by":"publisher","first-page":"2632","DOI":"10.3390\/diagnostics15202632","article-title":"ARCANA protocol for radiation-free craniosynostosis imaging","volume":"15","author":"Micovic","year":"2025","journal-title":"Diagnostics"},{"key":"2026111802534741500_tqag172-B54","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1186\/s43055-025-01581-3","article-title":"ZTE MRI in osteoarthritis knee evaluation","volume":"56","author":"Tawfik","year":"2025","journal-title":"Egypt J Radiol Nucl Med"},{"key":"2026111802534741500_tqag172-B55","doi-asserted-by":"publisher","first-page":"477","DOI":"10.3390\/info16060477","article-title":"Synthetic CT from ZTE MRI via deep learning","volume":"16","author":"Aouadi","year":"2025","journal-title":"Information"},{"key":"2026111802534741500_tqag172-B56","doi-asserted-by":"publisher","first-page":"1632","DOI":"10.21037\/qims-23-1042","article-title":"VNCa spectral CT for MM marrow infiltration","volume":"14","author":"Chen","year":"2024","journal-title":"Quant Imaging Med Surg"},{"key":"2026111802534741500_tqag172-B57","doi-asserted-by":"publisher","author":"Liang L, Xiao F, Liang L","DOI":"10.1007\/s00256-024-04805-1"},{"key":"2026111802534741500_tqag172-B58","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1148\/radiol.2018181168","article-title":"DECT VNCa in axial spondyloarthritis","volume":"290","author":"Wu","year":"2019","journal-title":"Radiology"},{"key":"2026111802534741500_tqag172-B59","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1148\/radiol.2017161525","article-title":"3rd-generation DECT for vertebral BME","volume":"284","author":"Petritsch","year":"2017","journal-title":"Radiology"},{"key":"2026111802534741500_tqag172-B60","doi-asserted-by":"publisher","first-page":"108817","DOI":"10.1016\/j.ejrad.2020.108817","article-title":"Disc degeneration assessment with DECT VNCa","volume":"124","author":"Shinohara","year":"2020","journal-title":"Eur J Radiol"},{"key":"2026111802534741500_tqag172-B61","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1186\/s13244-023-01407-8","article-title":"Accuracy of VNCa for BME detection","volume":"14","author":"Zhao","year":"2023","journal-title":"Insights Imaging"},{"key":"2026111802534741500_tqag172-B62","doi-asserted-by":"publisher","first-page":"e339","DOI":"10.1097\/RLI.0000000000001228","article-title":"Photon-counting CT for MM lesion vitality","volume":"59","author":"Heidemeier","year":"2024","journal-title":"Invest Radiol"},{"key":"2026111802534741500_tqag172-B63","doi-asserted-by":"publisher","first-page":"264","DOI":"10.3390\/jcm13010264","article-title":"Imaging of multiple myeloma: present and future","volume":"13","author":"Rodr\u00edguez-Laval","year":"2024","journal-title":"J Clin Med"},{"key":"2026111802534741500_tqag172-B64","doi-asserted-by":"publisher","first-page":"852","DOI":"10.2967\/jnumed.117.198051","article-title":"ZeDD-CT: pseudo-CT from ZTE\/Dixon MRI","volume":"59","author":"Leynes","year":"2018","journal-title":"J Nucl Med"},{"key":"2026111802534741500_tqag172-B65","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.media.2016.03.001","article-title":"MRI-guided attenuation correction in PET\/MRI","volume":"32","author":"Arabi","year":"2016","journal-title":"Med Image Anal"},{"key":"2026111802534741500_tqag172-B66","doi-asserted-by":"publisher","first-page":"198","DOI":"10.21037\/qims-24-1100","article-title":"Advances in imaging for MM and bone disease","volume":"15","author":"Talarico","year":"2025","journal-title":"Quant Imaging Med Surg"},{"key":"2026111802534741500_tqag172-B67","doi-asserted-by":"publisher","first-page":"402","DOI":"10.2214\/AJR.18.19933","article-title":"Detection of Lumbar spine osseous metastases using dual-energy CT: phantom results and preliminary clinical validation","volume":"212","author":"Lecouvet","year":"2019","journal-title":"AJR Am J Roentgenol"},{"key":"2026111802534741500_tqag172-B68","doi-asserted-by":"publisher","first-page":"18","DOI":"10.3390\/medicina57010018","article-title":"Chronic intradiploic organizing hematoma of the skull mimicking calvarial tumor diagnosed using zero TE MRI: a case report and review of literature","volume":"57","author":"Park","year":"2020","journal-title":"Medicina (Kaunas)"},{"key":"2026111802534741500_tqag172-B69","doi-asserted-by":"publisher","first-page":"402","DOI":"10.2214\/AJR.18.19933","article-title":"Detection of Lumbar spine osseous metastases using dual-energy CT: phantom results and preliminary clinical validation","volume":"212","author":"Huang","year":"2019","journal-title":"AJR Am J Roentgenol"},{"key":"2026111802534741500_tqag172-B70","doi-asserted-by":"publisher","first-page":"43","DOI":"10.2478\/raon-2024-0003","article-title":"Quantitative assessment of bone marrow infiltration and characterization of tumor burden using dual-layer spectral CT in patients with multiple myeloma","volume":"58","author":"Xiong","year":"2024","journal-title":"Radiol Oncol"},{"key":"2026111802534741500_tqag172-B71","doi-asserted-by":"publisher","first-page":"100636","DOI":"10.1016\/j.jbo.2024.100636","article-title":"Diagnosis of newly developed multiple myeloma without bone disease detectable on conventional computed tomography (CT) scan by using dual-energy CT","volume":"48","author":"Jiang","year":"2024","journal-title":"J Bone Oncol"}],"container-title":["British Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/bjr\/advance-article-pdf\/doi\/10.1093\/bjr\/tqag172\/70351796\/tqag172.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/99\/1188\/2439\/70351796\/tqag172.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/99\/1188\/2439\/70351796\/tqag172.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T07:53:52Z","timestamp":1794988432000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjr\/article\/99\/1188\/2439\/8746886"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,29]]},"references-count":71,"journal-issue":{"issue":"1188","published-online":{"date-parts":[[2026,7,29]]},"published-print":{"date-parts":[[2026,12,1]]}},"URL":"https:\/\/doi.org\/10.1093\/bjr\/tqag172","relation":{},"ISSN":["0007-1285","1748-880X"],"issn-type":[{"value":"0007-1285","type":"print"},{"value":"1748-880X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,12]]},"published":{"date-parts":[[2026,7,29]]}}}