{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T17:00:56Z","timestamp":1790787656137,"version":"4.1.0"},"reference-count":10,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[2025,12,27]],"date-time":"2025-12-27T00:00:00Z","timestamp":1766793600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,1,15]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Totally implantable venous access devices provide long-term venous access for patients requiring extended therapies, such as chemotherapy, with lower risks of infection and extravasation. These devices are typically placed in the subclavian or internal jugular vein and connected to a subcutaneous port. Following implantation, a chest X-ray is used to confirm catheter placement, detect early complications, and identify the \u201cpinch-off sign\u201d\u2014a warning of potential catheter compression between the clavicle and first rib. Complications include malposition, pneumothorax, infection and catheter dysfunction such as pinch-off syndrome (POS), catheter fracture, and migration. POS can cause catheter dysfunction, fracture, and migration, potentially leading to severe cardiovascular or neurological complications, including cardiac perforation and pulmonary embolism. In some cases, catheter migration is asymptomatic and discovered incidentally. When catheter fragments migrate, removal via a percutaneous transvenous approach is preferred to avoid complications. However, in asymptomatic patients, observation may be a suitable alternative if the fragment adheres to the vessel. We report the case of a 25-year-old patient under surveillance for metastatic medullary thyroid carcinoma, whose catheter migrated to the pulmonary artery and remained complication-free for 6 years. This case highlights the importance of routinely checking for pinch-off syndrome whenever a central catheter is placed, and it suggests that removal of migrated catheter fragments may not be necessary in asymptomatic patients.<\/jats:p>","DOI":"10.1093\/bjrcr\/uaaf056","type":"journal-article","created":{"date-parts":[[2025,12,27]],"date-time":"2025-12-27T07:46:23Z","timestamp":1766821583000},"source":"Crossref","is-referenced-by-count":1,"title":["Pinch-off syndrome leading to catheter fracture: a rare complication of central venous port systems, a case report"],"prefix":"10.1093","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8775-4187","authenticated-orcid":false,"given":"Soumya","family":"El Graini","sequence":"first","affiliation":[{"name":"Radiology Department, National Institute of Oncology , Rabat 6527, Morocco"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6501-6888","authenticated-orcid":false,"given":"Ibtissam","family":"El Ouali","sequence":"additional","affiliation":[{"name":"Radiology Department, National Institute of Oncology , Rabat 6527, Morocco"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2151-2721","authenticated-orcid":false,"given":"Hamza","family":"Retal","sequence":"additional","affiliation":[{"name":"Radiology Department, National Institute of Oncology , Rabat 6527, Morocco"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-6074-1617","authenticated-orcid":false,"given":"Youssef","family":"Omor","sequence":"additional","affiliation":[{"name":"Radiology Department, National Institute of Oncology , Rabat 6527, Morocco"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-2993-3906","authenticated-orcid":false,"given":"Rachida","family":"Latib","sequence":"additional","affiliation":[{"name":"Radiology Department, National Institute of Oncology , Rabat 6527, Morocco"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3770-7248","authenticated-orcid":false,"given":"Sanae","family":"Amalik","sequence":"additional","affiliation":[{"name":"Radiology Department, National Institute of Oncology , Rabat 6527, Morocco"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2025,12,27]]},"reference":[{"key":"2026011801562233200_uaaf056-B1","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.revmed.2013.08.008","article-title":"Catheter fracture and pulmonary embolization of the distal fragment: a rare complication of the totally implantable venous access port","volume":"36","author":"Rebahi","year":"2015","journal-title":"Revue De Medecine Interne"},{"key":"2026011801562233200_uaaf056-B2","doi-asserted-by":"publisher","first-page":"333","DOI":"10.5090\/kjtcs.2018.51.5.333","article-title":"Pinch-off syndrome, a rare complication of totally implantable venous access device implantation: a case series and literature review","volume":"51","author":"Ilhan","year":"2018","journal-title":"Korean J Thorac Cardiovasc Surg"},{"key":"2026011801562233200_uaaf056-B3","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1186\/s13244-019-0770-2","article-title":"Complications of central venous port systems: a pictorial review","volume":"10","author":"Machat","year":"2019","journal-title":"Insights Imaging"},{"key":"2026011801562233200_uaaf056-B4","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1186\/s12885-016-2791-2","article-title":"Internal jugular vein versus subclavian vein as the percutaneous insertion site for totally implantable venous access devices: a meta-analysis of comparative studies","volume":"16","author":"Wu","year":"2016","journal-title":"BMC Cancer"},{"key":"2026011801562233200_uaaf056-B5","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1148\/radiology.177.2.2217768","article-title":"Pinch-off syndrome: a complication of implantable subclavian venous access devices","volume":"177","author":"Hinke","year":"1990","journal-title":"Radiology"},{"key":"2026011801562233200_uaaf056-B6","doi-asserted-by":"publisher","first-page":"e27485","DOI":"10.7759\/cureus.27485","article-title":"Complications of totally implantable central venous catheters (ports) inserted via the internal jugular vein under ultrasound and fluoroscopy guidance in adult oncology patients: a single-center experience","volume":"14","author":"Kartsouni","year":"2022","journal-title":"Cureus"},{"key":"2026011801562233200_uaaf056-B7","doi-asserted-by":"publisher","first-page":"103","DOI":"10.2484\/rcr.v1i3.41","article-title":"Wandering catheter through pulmonary vasculature","volume":"1","author":"Lee","year":"2006","journal-title":"Radiol Case Rep"},{"key":"2026011801562233200_uaaf056-B8","doi-asserted-by":"publisher","first-page":"970","DOI":"10.1056\/NEJM199309233291319","article-title":"14-year follow-up of central embolization by a guidewire","volume":"329","author":"Reynen","year":"1993","journal-title":"N Engl J Med"},{"key":"2026011801562233200_uaaf056-B9","doi-asserted-by":"publisher","first-page":"1209","DOI":"10.1378\/chest.117.4.1209","article-title":"Retrieval of an IV catheter fragment from the pulmonary artery 11 years after embolization","volume":"117","author":"Thanigaraj","year":"2000","journal-title":"Chest"},{"key":"2026011801562233200_uaaf056-B10","doi-asserted-by":"publisher","DOI":"10.1136\/bcr-2019-233779","article-title":"Pinch-off syndrome: a rare and serious complication of central venous catheters","volume":"13","author":"Hadid","year":"2020","journal-title":"BMJ Case Rep"}],"container-title":["BJR|Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/bjrcr\/advance-article-pdf\/doi\/10.1093\/bjrcr\/uaaf056\/66138056\/uaaf056.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjrcr\/article-pdf\/12\/1\/uaaf056\/66138056\/uaaf056.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjrcr\/article-pdf\/12\/1\/uaaf056\/66138056\/uaaf056.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T06:56:30Z","timestamp":1768719390000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjrcr\/article\/doi\/10.1093\/bjrcr\/uaaf056\/8405648"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,27]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1,15]]}},"URL":"https:\/\/doi.org\/10.1093\/bjrcr\/uaaf056","relation":{},"ISSN":["2055-7159"],"issn-type":[{"value":"2055-7159","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,1]]},"published":{"date-parts":[[2025,12,27]]},"article-number":"uaaf056"}}