{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:16:05Z","timestamp":1787008565280,"version":"build-2736575974"},"reference-count":44,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2021,11,19]],"date-time":"2021-11-19T00:00:00Z","timestamp":1637280000000},"content-version":"vor","delay-in-days":49,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,10,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>EEG source imaging is becoming widely used for the evaluation of medically refractory focal epilepsy. The validity of EEG source imaging has been established in several studies comparing source imaging to the surgical resection cavity and subsequent seizure freedom. We present a cohort of 87 patients and compare EEG source imaging of both ictal and interictal scalp EEG to the seizure onset zone on intracranial EEG. Concordance of EEG source imaging with intracranial EEG was determined on a sublobar level and was quantified by measuring the distance between the source imaging result and the centroid of the active seizure onset zone electrodes. The EEG source imaging results of a subgroup of 26 patients with high density 76-channel EEG were compared with the localization of three experienced epileptologists. Of 87 patients, 95% had at least one analysis concordant with intracranial EEG and 74% had complete concordance. There was a higher rate of complete concordance in temporal lobe epilepsy compared to extratemporal (89.3 and 62.8%, respectively, P = 0.015). Of the total 282 analyses performed on this cohort, higher concordance was also seen in temporal discharges (95%) compared to extratemporal (77%) (P = 0.0012), but no difference was seen comparing high-density EEG with standard (32-channel) EEG. Subgroup analysis of ictal waveforms showed greater concordance for ictal spiking, compared with rhythmic activity, paroxysmal fast activity, or obscured onset. Median distances from the dipole and maximum distributed source to a centroid of seizure onset zone electrodes were 30.0 and 32.5 mm, respectively, and the median distances from dipole and maximum distributed source to nearest seizure onset zone electrode were 22.8 and 21.7, respectively. There were significantly shorter distances in ictal spiking. There were shorter distances in patients with Engel Class 1 outcome from surgical resection compared to patients with worse outcomes. For the subgroup of 26 high-density EEG patients, EEG source localization had a significantly higher concordance (92% versus 65%), sensitivity (57% versus 35%) and positive predictive value (60% versus 36%) compared with epileptologist localization. Our study demonstrates good concordance between ictal and interictal source imaging and intracranial EEG. Temporal lobe discharges have higher concordance rates than extratemporal discharges. Importantly, this study shows that source imaging has greater agreement with intracranial EEG than visual review alone, supporting its role in surgical planning.<\/jats:p>","DOI":"10.1093\/braincomms\/fcab278","type":"journal-article","created":{"date-parts":[[2021,11,16]],"date-time":"2021-11-16T07:10:56Z","timestamp":1637046656000},"source":"Crossref","is-referenced-by-count":30,"title":["EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy"],"prefix":"10.1093","volume":"3","author":[{"given":"Benjamin C","family":"Cox","sequence":"first","affiliation":[{"name":"Department of Neurology, Mayo Clinic, Rochester, MN 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9168-4027","authenticated-orcid":false,"given":"Omar A","family":"Danoun","sequence":"additional","affiliation":[{"name":"Department of Neurology, Henry Ford Hospital, Detroit, MI 48202, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5310-5549","authenticated-orcid":false,"given":"Brian Nils","family":"Lundstrom","sequence":"additional","affiliation":[{"name":"Department of Neurology, Mayo Clinic, Rochester, MN 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Terrence D","family":"Lagerlund","sequence":"additional","affiliation":[{"name":"Department of Neurology, Mayo Clinic, Rochester, MN 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lily C","family":"Wong-Kisiel","sequence":"additional","affiliation":[{"name":"Department of Neurology, Mayo Clinic, Rochester, MN 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2392-8608","authenticated-orcid":false,"given":"Benjamin H","family":"Brinkmann","sequence":"additional","affiliation":[{"name":"Department of Neurology, Mayo Clinic, Rochester, MN 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2021,11,19]]},"reference":[{"key":"2021120506331276800_fcab278-B1","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.seizure.2016.05.018","article-title":"Correlation of invasive EEG and scalp EEG","volume":"41","author":"Ramantani","year":"2016","journal-title":"Seizure"},{"issue":"2","key":"2021120506331276800_fcab278-B2","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1097\/WNP.0b013e31803ece13","article-title":"Clinical application of dipole models in localization of epilpetiform activity","volume":"24","author":"Ebersole","year":"2007","journal-title":"J Clin Neurophysiol"},{"issue":"1","key":"2021120506331276800_fcab278-B3","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1007\/BF01128858","article-title":"Spike voltage topography and equivalent dipole localization in complex partial epilepsy","volume":"3","author":"Ebersole","year":"1990","journal-title":"Brain Topogr"},{"issue":"4","key":"2021120506331276800_fcab278-B4","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1097\/01.wnp.0000214588.94843.c2","article-title":"Electric source imaging in frontal lobe epilepsy","volume":"23","author":"Gavaret","year":"2006","journal-title":"J Clin Neurophysiol"},{"issue":"2","key":"2021120506331276800_fcab278-B5","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/0896-6974(94)90009-4","article-title":"Three-dimensional localization of interictal epileptiform activity with dipole analysis: Comparison with intracranial recordings and SPECT findings","volume":"7","author":"Lantz","year":"1994","journal-title":"J Epilepsy"},{"issue":"18","key":"2021120506331276800_fcab278-B6","doi-asserted-by":"crossref","first-page":"4007","DOI":"10.1097\/00001756-199812210-00004","article-title":"Dipole source localization of ictal epileptiform activity","volume":"9","author":"Mine","year":"1998","journal-title":"Neuroreport"},{"issue":"1","key":"2021120506331276800_fcab278-B7","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/S0987-7053(05)80405-8","article-title":"Brain source imaging of focal and multifocal epileptiform EEG activity","volume":"24","author":"Scherg","year":"1994","journal-title":"Neurophysiol Clin"},{"key":"2021120506331276800_fcab278-B8","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.nicl.2014.06.005","article-title":"Head model and electrical source imaging: A study of 38 epileptic patients","volume":"5","author":"Birot","year":"2014","journal-title":"Neuroimage Clin"},{"issue":"9","key":"2021120506331276800_fcab278-B9","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1038\/nrneurol.2012.150","article-title":"EEG source imaging in epilepsy \u2013 Practicalities and pitfalls","volume":"8","author":"Kaiboriboon","year":"2012","journal-title":"Nat Rev Neurol"},{"key":"2021120506331276800_fcab278-B10","first-page":"85","volume-title":"Handbook of clinical neurology","author":"Michel","year":"2019"},{"issue":"10","key":"2021120506331276800_fcab278-B11","doi-asserted-by":"crossref","first-page":"1726","DOI":"10.1016\/j.clinph.2010.04.002","article-title":"Clinical utility of distributed source modelling of interictal scalp EEG in focal epilepsy","volume":"121","author":"Plummer","year":"2010","journal-title":"Clin Neurophysiol"},{"issue":"2","key":"2021120506331276800_fcab278-B12","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1097\/WNP.0b013e31803ecdaf","article-title":"Cortical substrates of scalp EEG epileptiform discharges","volume":"24","author":"Tao","year":"2007","journal-title":"J Clin Neurophysiol"},{"key":"2021120506331276800_fcab278-B13","doi-asserted-by":"crossref","first-page":"108740","DOI":"10.1016\/j.jneumeth.2020.108740","article-title":"R.T. A systematic review of EEG source localization techniques and their applications on diagnosis of brain abnormalities","volume":"339","author":"Asadzadeh","year":"2020","journal-title":"J Neurosci Methods"},{"issue":"10","key":"2021120506331276800_fcab278-B14","doi-asserted-by":"crossref","first-page":"2887","DOI":"10.1093\/brain\/awr243","article-title":"Electroencephalographic source imaging: A prospective study of 152 operated epileptic patients","volume":"134","author":"Brodbeck","year":"2011","journal-title":"Brain"},{"issue":"6","key":"2021120506331276800_fcab278-B15","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1016\/j.clinph.2018.03.020","article-title":"Automatic ictal onset source localization in presurgical epilepsy evaluation","volume":"129","author":"Koren","year":"2018","journal-title":"Clin Neurophysiol"},{"issue":"9","key":"2021120506331276800_fcab278-B16","doi-asserted-by":"crossref","first-page":"1154","DOI":"10.1111\/ene.13676","article-title":"Ictal and interictal electric source imaging in pre-surgical evaluation: A prospective study","volume":"25","author":"Sharma","year":"2018","journal-title":"Eur J Neurol"},{"issue":"5","key":"2021120506331276800_fcab278-B17","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.clinph.2018.12.016","article-title":"Diagnostic accuracy of interictal source imaging in presurgical epilepsy evaluation: A systematic review from the E-PILEPSY consortium","volume":"130","author":"Mouthaan","year":"2019","journal-title":"Clin Neurophysiol"},{"issue":"2","key":"2021120506331276800_fcab278-B18","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1016\/j.neuroimage.2010.02.067","article-title":"Source localization of ictal epileptic activity investigated by high resolution EEG and validated by SEEG","volume":"51","author":"Koessler","year":"2010","journal-title":"Neuroimage"},{"key":"2021120506331276800_fcab278-B19","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/j.eplepsyres.2018.07.006","article-title":"EEG source imaging of epileptic activity at seizure onset","volume":"146","author":"Kuo","year":"2018","journal-title":"Epilepsy Res"},{"issue":"1","key":"2021120506331276800_fcab278-B20","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/S1388-2457(02)00337-1","article-title":"Epileptic source localization with high density EEG: How many electrodes are needed?","volume":"114","author":"Lantz","year":"2003","journal-title":"Clin Neurophysiol"},{"issue":"1","key":"2021120506331276800_fcab278-B21","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.clinph.2015.03.025","article-title":"Yield of MRI, high-density electric source imaging (HD-ESI), SPECT and PET in epilepsy surgery candidates","volume":"127","author":"Lascano","year":"2016","journal-title":"Clin Neurophysiol"},{"issue":"6","key":"2021120506331276800_fcab278-B22","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1111\/epi.13749","article-title":"Source localization of ictal epileptic activity based on high-density scalp EEG data","volume":"58","author":"Nemtsas","year":"2017","journal-title":"Epilepsia"},{"issue":"6","key":"2021120506331276800_fcab278-B23","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1016\/j.clinph.2010.10.043","article-title":"Interictal spike analysis of high density EEG in patients with partial epilepsy","volume":"122","author":"Wang","year":"2011","journal-title":"Clin Neurophysiol"},{"issue":"2","key":"2021120506331276800_fcab278-B24","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1111\/j.1528-1167.2007.01381.x","article-title":"EEG source localization in focal epilepsy: Where are we now?","volume":"49","author":"Plummer","year":"2008","journal-title":"Epilepsia"},{"key":"2021120506331276800_fcab278-B25","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.3389\/fneur.2019.01250","article-title":"Accuracy of interictal and Ictal electric and magnetic source imaging: A systematic review and meta-analysis","volume":"10","author":"Sharma","year":"2019","journal-title":"Front Neurol"},{"key":"2021120506331276800_fcab278-B26","first-page":"5","article-title":"Standardized low-resolution brain electromagnetic tomography (sLORETA): Technical details","volume":"24 (Suppl D","author":"Pascual-Marqui","year":"2002","journal-title":"Methods Find Exp Clin Pharmacol"},{"issue":"11","key":"2021120506331276800_fcab278-B27","doi-asserted-by":"crossref","first-page":"1342","DOI":"10.1109\/10.725331","article-title":"Recursive MUSIC: A framework for EEG and MEG source localization","volume":"45","author":"Mosher","year":"1998","journal-title":"IEEE Trans Biomed Eng"},{"key":"2021120506331276800_fcab278-B28","doi-asserted-by":"crossref","first-page":"2127","DOI":"10.1016\/j.clinph.2015.12.021","article-title":"Epileptiform discharge propagation: Analyzing spikes from the onset to the peak","volume":"127","author":"Maliia","year":"2016","journal-title":"Clin Neurophysiol"},{"issue":"10","key":"2021120506331276800_fcab278-B29","doi-asserted-by":"crossref","first-page":"1743","DOI":"10.1111\/epi.12339","article-title":"Source localization of rhythmic ictal EEG activity: A study of diagnostic accuracy following STARD criteria","volume":"54","author":"Beniczky","year":"2013","journal-title":"Epilepsia"},{"issue":"1","key":"2021120506331276800_fcab278-B30","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/S0013-4694(98)00117-5","article-title":"Frequency domain EEG source localization of ictal epileptiform activity in patients with partial complex epilepsy of temporal lobe origin","volume":"110","author":"Lantz","year":"1999","journal-title":"Clin Neurophysiol"},{"key":"2021120506331276800_fcab278-B31","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1111\/epi.12004","article-title":"Magnetic source imaging and ictal SP ECT in MRI-negative neocortical epilepsies: Additional value and comparison with intracranial EEG","volume":"54","author":"Schneider","year":"2013","journal-title":"Epilepsia"},{"issue":"6","key":"2021120506331276800_fcab278-B32","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1097\/WNP.0b013e318201ffc4","article-title":"Combining MEG and EEG source modeling in epilepsy evaluations","volume":"27","author":"Ebersole","year":"2010","journal-title":"J Clin Neurophysiol"},{"key":"2021120506331276800_fcab278-B33","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.3389\/fneur.2019.01263","article-title":"Epileptogenicity maps of intracerebral fast activities (60-100 Hz) at seizure onset in epilepsy surgery candidates","volume":"10","author":"Job","year":"2019","journal-title":"Front Neurol"},{"issue":"Pt 1","key":"2021120506331276800_fcab278-B34","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1093\/brain\/awt299","article-title":"Intracranial electroencephalographic seizure-onset patterns: Effect of underlying pathology","volume":"137","author":"Perucca","year":"2014","journal-title":"Brain"},{"issue":"12","key":"2021120506331276800_fcab278-B35","doi-asserted-by":"crossref","first-page":"1300","DOI":"10.1111\/j.1528-1157.1997.tb00068.x","article-title":"Relations between EEG seizure morphology, interhemispheric spread, and mesial temporal atrophy in bitemporal epilepsy","volume":"38","author":"Spanedda","year":"1997","journal-title":"Epilepsia"},{"key":"2021120506331276800_fcab278-B36","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1136\/jnnp-2013-305515","article-title":"Electric source imaging of interictal activity accurately localises the seizure onset zone","volume":"85","author":"M\u00e9gevand","year":"2014","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"2021120506331276800_fcab278-B37","first-page":"609","volume-title":"Surgical treatment of the epilepsies","author":"Engel","year":"1993"},{"issue":"1","key":"2021120506331276800_fcab278-B38","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1080\/00365510701666031","article-title":"McNemar chi2 test revisited: Comparing sensitivity and specificity of diagnostic examinations","volume":"68","author":"Trajman","year":"2008","journal-title":"Scand J Clin Lab Invest"},{"key":"2021120506331276800_fcab278-B39","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1080\/21646821.2018.1491173","article-title":"Use of subtemporal electrode chains and their contribution to presurgical evaluation","volume":"58","author":"Keller","year":"2018","journal-title":"Neurodiagn J"},{"issue":"1","key":"2021120506331276800_fcab278-B40","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/WNP.0000000000000019","article-title":"Beyond the double banana: Improved recognition of temporal lobe seizures in long-term EEG","volume":"31","author":"Rosenzweig","year":"2014","journal-title":"J Clin Neurophysiol"},{"issue":"10","key":"2021120506331276800_fcab278-B41","doi-asserted-by":"crossref","first-page":"2070","DOI":"10.1016\/j.clinph.2017.06.254","article-title":"The standardized EEG array of IFCN","volume":"128","author":"Seeck","year":"2017","journal-title":"Clin Neurophysiol"},{"issue":"Pt 5","key":"2021120506331276800_fcab278-B42","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.1093\/brain\/awh449","article-title":"Long-term seizure outcomes following epilepsy surgery: A systematic review and meta-analysis","volume":"128","author":"T\u00e9llez-Zenteno","year":"2005","journal-title":"Brain"},{"issue":"3","key":"2021120506331276800_fcab278-B43","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1016\/j.clinph.2014.05.038","article-title":"Effect of EEG electrode number on epileptic source localization in pediatric patients","volume":"126","author":"Sohrabpour","year":"2015","journal-title":"Clin Neurophysiol"},{"key":"2021120506331276800_fcab278-B44","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.seizure.2016.09.017","article-title":"Ictal EEG source imaging in presurgical evaluation: High agreement between analysis methods","volume":"43","author":"Beniczky","year":"2016","journal-title":"Seizure"}],"container-title":["Brain Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/braincomms\/article-pdf\/3\/4\/fcab278\/41468058\/fcab278.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/braincomms\/article-pdf\/3\/4\/fcab278\/41468058\/fcab278.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,12]],"date-time":"2023-11-12T13:28:02Z","timestamp":1699795682000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/braincomms\/article\/doi\/10.1093\/braincomms\/fcab278\/6432037"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,1]]},"references-count":44,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,10,1]]}},"URL":"https:\/\/doi.org\/10.1093\/braincomms\/fcab278","relation":{},"ISSN":["2632-1297"],"issn-type":[{"value":"2632-1297","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2021,10,1]]},"published":{"date-parts":[[2021,10,1]]},"article-number":"fcab278"}}