{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T09:15:59Z","timestamp":1788513359367,"version":"build-2803163510"},"reference-count":53,"publisher":"Oxford University Press (OUP)","issue":"9","license":[{"start":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T00:00:00Z","timestamp":1786492800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004955","name":"\u00d6sterreichische Forschungsf\u00f6rderungsgesellschaft","doi-asserted-by":"publisher","award":["56872670"],"award-info":[{"award-number":["56872670"]}],"id":[{"id":"10.13039\/501100004955","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,9,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Ambulatory blood pressure (BP) and pulse wave characteristics (PWCs) are stronger predictors of mortality than conventional pre-\/post-dialytic BP in hemodialysis. While BP is recommended to be managed primarily by reducing fluid overload (FO), associations of FO with interdialytic BP\/PWCs remain unknown.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Bioimpedance-derived FO and interdialytic 44-h BP\/PWCs were analyzed at baseline and follow-up of a quality improvement project involving targeted fluid management. Trended cosinor linear mixed-effects models assessed intra-patient associations of post-dialysis FO with interdialytic BP\/PWCs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>We analyzed 120 visits (77\/43 at baseline\/follow-up) from 80 patients (70% male; mean age 68 \u00b1 14 years; median dialysis vintage 38 [18\u201364] months). Post-dialysis FO decreased in baseline hypervolemic patients from 2.7 \u00b1 1.3 L to 0.9 \u00b1 1.7 L. Every 1 L increase in post-dialysis FO at the patient level was associated with increased peripheral BP (systolic: 4.54 mmHg, P\u00a0&amp;lt;\u00a00.001; diastolic: 2.55\u00a0mmHg, P\u00a0&amp;lt; 0.001), peripheral resistance (0.03 s*mmHg\/mL, P\u00a0=\u00a00.011), augmentation index (1.38%, P\u00a0=\u00a00.007), wave amplitudes (forward: 0.56\u00a0mmHg, P\u00a0=\u00a00.025; backward: 0.61\u00a0mmHg, P\u00a0=\u00a00.027), reservoir pressure peak (3.83\u00a0mmHg, P\u00a0&amp;lt;\u00a00.001), and pulse wave velocity (0.12\u00a0m\/s, P\u00a0=\u00a00.007). Higher FO was associated with decreased interdialytic slopes of all BPs, peripheral resistance, backward wave amplitude, reservoir peak pressure, and pulse wave velocity. FO interacted with circadian rhythms of stroke volume, peripheral resistance, forward wave amplitude, and excess pressure peak.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>We showed that FO in hemodialysis is associated with increased interdialytic BP and PWCs on a patient level, and that FO blunts interdialytic BP\/PWC trends. We further establish that physiological BP\/PWC patterns may be associated with euvolemic fluid status, hence making the case for tailoring target weight using bioimpedance spectroscopy.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ckj\/sfag273","type":"journal-article","created":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T11:37:46Z","timestamp":1786448266000},"source":"Crossref","is-referenced-by-count":0,"title":["Fluid overload modifies ambulatory blood pressure and pulse wave characteristics in hemodialysis patients undergoing targeted fluid management"],"prefix":"10.1093","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2223-2067","authenticated-orcid":false,"given":"Sebastian","family":"Mussnig","sequence":"first","affiliation":[{"name":"Department of Medicine III, Division for Nephrology and Dialysis, Medical University of Vienna , Vienna ,","place":["Austria"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7970-7022","authenticated-orcid":false,"given":"Luis","family":"Naar","sequence":"additional","affiliation":[{"name":"Department of Medicine III, Division for Nephrology and Dialysis, Medical University of Vienna , Vienna ,","place":["Austria"]},{"name":"Center for Public Health, Department of Epidemiology, Medical University of Vienna , Vienna ,","place":["Austria"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6216-9635","authenticated-orcid":false,"given":"Marieta","family":"Theodorakopoulou","sequence":"additional","affiliation":[{"name":"Department of Medicine III, Division for Nephrology and Dialysis, Medical University of Vienna , Vienna ,","place":["Austria"]},{"name":"First Department of Nephrology, Hippokration Hospital, Aristotle University of Thessaloniki , Thessaloniki ,","place":["Greece"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-0377-7061","authenticated-orcid":false,"given":"Janosch","family":"Niknam\u00a0Saeidi","sequence":"additional","affiliation":[{"name":"Department of Medicine III, Division for Nephrology and Dialysis, Medical University of Vienna , Vienna ,","place":["Austria"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1907-825X","authenticated-orcid":false,"given":"Joachim","family":"Beige","sequence":"additional","affiliation":[{"name":"Kuratorium for Dialysis and Transplantation e.V. (KfH) , Neu-Isenburg ,","place":["Germany"]},{"name":"Medical Clinic 2, Martin-Luther-University Halle\/Wittenberg , Halle ,","place":["Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4744-4106","authenticated-orcid":false,"given":"David","family":"Keane","sequence":"additional","affiliation":[{"name":"CURAM, Center for Research in Medical Devices, University of Galway , Galway ,","place":["Ireland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0124-1012","authenticated-orcid":false,"given":"Daniel","family":"Schneditz","sequence":"additional","affiliation":[{"name":"Otto Loewi Research Center for Vascular Biology, Immunology and Inflammation, Division of Physiology & Pathophysiology, Medical University of Graz , Graz ,","place":["Austria"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9174-4018","authenticated-orcid":false,"given":"Pantelis","family":"Sarafidis","sequence":"additional","affiliation":[{"name":"First Department of Nephrology, Hippokration Hospital, Aristotle University of Thessaloniki , Thessaloniki ,","place":["Greece"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5599-9689","authenticated-orcid":false,"given":"Siegfried","family":"Wassertheurer","sequence":"additional","affiliation":[{"name":"Medical Signal Analysis, Center for Health & Bioresources, AIT Austrian Institute of Technology GmbH , Vienna ,","place":["Austria"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5612-5481","authenticated-orcid":false,"given":"Christopher C","family":"Mayer","sequence":"additional","affiliation":[{"name":"Medical Signal Analysis, Center for Health & Bioresources, AIT Austrian Institute of Technology GmbH , Vienna ,","place":["Austria"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8047-2395","authenticated-orcid":false,"given":"Manfred","family":"Hecking","sequence":"additional","affiliation":[{"name":"Department of Medicine III, Division for Nephrology and Dialysis, Medical University of Vienna , Vienna ,","place":["Austria"]},{"name":"Kuratorium for Dialysis and Transplantation e.V. (KfH) , Neu-Isenburg ,","place":["Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,8,12]]},"reference":[{"key":"2026090404411530800_bib1","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1016\/S0272-6386(99)70188-5","article-title":"Predialysis blood pressure and mortality risk in a national sample of maintenance hemodialysis patients","volume":"33","author":"Port","year":"1999","journal-title":"Am J Kidney Dis"},{"key":"2026090404411530800_bib2","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1038\/ki.2012.136","article-title":"Blood pressure levels and mortality risk among hemodialysis patients in the Dialysis Outcomes and Practice Patterns Study","volume":"82","author":"Robinson","year":"2012","journal-title":"Kidney Int"},{"key":"2026090404411530800_bib3","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1161\/HYPERTENSIONAHA.114.04334","article-title":"Blood pressure and risk of all-cause mortality in advanced chronic kidney disease and hemodialysis: the chronic renal insufficiency cohort study","volume":"65","author":"Bansal","year":"2015","journal-title":"Hypertension"},{"key":"2026090404411530800_bib4","doi-asserted-by":"publisher","first-page":"389","DOI":"10.2215\/CJN.01891105","article-title":"Pre- and postdialysis blood pressures are imprecise estimates of interdialytic ambulatory blood pressure","volume":"1","author":"Agarwal","year":"2006","journal-title":"Clin J Am Soc Nephrol"},{"key":"2026090404411530800_bib5","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1159\/000068038","article-title":"Profile of interdialytic blood pressure in hemodialysis patients","volume":"23","author":"Santos","year":"2003","journal-title":"Am J Nephrol"},{"key":"2026090404411530800_bib6","doi-asserted-by":"publisher","first-page":"2517","DOI":"10.1097\/HJH.0000000000001478","article-title":"Blood pressure variability is increasing from the first to the second day of the interdialytic interval in hemodialysis patients","volume":"35","author":"Karpetas","year":"2017","journal-title":"J Hypertens"},{"key":"2026090404411530800_bib7","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1053\/j.ajkd.2009.03.018","article-title":"Chronobiology of arterial hypertension in hemodialysis patients: implications for home blood pressure monitoring","volume":"54","author":"Agarwal","year":"2009","journal-title":"Am J Kidney Dis"},{"key":"2026090404411530800_bib8","doi-asserted-by":"publisher","first-page":"762","DOI":"10.1161\/HYPERTENSIONAHA.109.144899","article-title":"Blood pressure and mortality among hemodialysis patients","volume":"55","author":"Agarwal","year":"2010","journal-title":"Hypertension"},{"key":"2026090404411530800_bib9","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1093\/ndt\/gfy247","article-title":"The association of interdialytic blood pressure variability with cardiovascular events and all-cause mortality in haemodialysis patients","volume":"34","author":"Sarafidis","year":"2019","journal-title":"Nephrol Dial Transplant"},{"key":"2026090404411530800_bib10","doi-asserted-by":"publisher","first-page":"2485","DOI":"10.1046\/j.1523-1755.2000.00107.x","article-title":"Nocturnal blood pressure and 24-hour pulse pressure are potent indicators of mortality in hemodialysis patients","volume":"57","author":"Amar","year":"2000","journal-title":"Kidney Int"},{"key":"2026090404411530800_bib11","doi-asserted-by":"publisher","first-page":"1294","DOI":"10.1111\/j.1523-1755.2005.00527.x","article-title":"Prognostic value of 24-hour ambulatory blood pressure monitoring and of night\/day ratio in nondiabetic, cardiovascular events-free hemodialysis patients","volume":"68","author":"Tripepi","year":"2005","journal-title":"Kidney Int"},{"key":"2026090404411530800_bib12","doi-asserted-by":"publisher","first-page":"1231","DOI":"10.1161\/HYPERTENSIONAHA.120.15420","article-title":"Heart failure and atrial fibrillation modify the associations of nocturnal blood pressure dipping pattern with mortality in hemodialysis patients","volume":"76","author":"Mayer","year":"2020","journal-title":"Hypertension"},{"key":"2026090404411530800_bib13","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1161\/HYPERTENSIONAHA.117.09023","article-title":"Ambulatory pulse wave velocity is a stronger predictor of cardiovascular events and all-cause mortality than office and ambulatory blood pressure in hemodialysis patients","volume":"70","author":"Sarafidis","year":"2017","journal-title":"Hypertension"},{"key":"2026090404411530800_bib14","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1159\/000499532","article-title":"Comparison of 24-hour and office pulse wave velocity for prediction of mortality in hemodialysis patients","volume":"49","author":"Matschkal","year":"2019","journal-title":"Am J Nephrol"},{"key":"2026090404411530800_bib15","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1016\/j.kint.2020.01.046","article-title":"Blood pressure and volume management in dialysis: conclusions from a Kidney Disease: improving Global Outcomes (KDIGO) Controversies Conference","volume":"97","author":"Flythe","year":"2020","journal-title":"Kidney Int"},{"key":"2026090404411530800_bib16","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1161\/HYPERTENSIONAHA.108.125674","article-title":"Dry-weight reduction in hypertensive hemodialysis patients (DRIP): a randomized, controlled trial","volume":"53","author":"Agarwal","year":"2009","journal-title":"Hypertension"},{"key":"2026090404411530800_bib17","doi-asserted-by":"publisher","first-page":"1505","DOI":"10.1016\/j.kint.2019.02.018","article-title":"The effect of dry-weight reduction guided by lung ultrasound on ambulatory blood pressure in hemodialysis patients: a randomized controlled trial","volume":"95","author":"Loutradis","year":"2019","journal-title":"Kidney Int"},{"key":"2026090404411530800_bib18","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.1007\/s40620-020-00745-w","article-title":"Excess volume removal following lung ultrasound evaluation decreases central blood pressure and pulse wave velocity in hemodialysis patients: a LUST sub-study","volume":"33","author":"Loutradis","year":"2020","journal-title":"J Nephrol"},{"key":"2026090404411530800_bib19","doi-asserted-by":"publisher","first-page":"2046","DOI":"10.1093\/ndt\/gfv090","article-title":"Ambulatory aortic blood pressure, wave reflections and pulse wave velocity are elevated during the third in comparison to the second interdialytic day of the long interval in chronic haemodialysis patients","volume":"30","author":"Koutroumbas","year":"2015","journal-title":"Nephro. Dial Transplant"},{"key":"2026090404411530800_bib20","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1161\/HYPERTENSIONAHA.107.091579","article-title":"Trended cosinor change model for analyzing hemodynamic rhythm patterns in hemodialysis patients","volume":"50","author":"Kelley","year":"2007","journal-title":"Hypertension"},{"key":"2026090404411530800_bib21","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1093\/ndt\/gfad206","article-title":"Bioimpedance-derived euvolemic weight varies in hemodialysis patients\u2014challenging the fixed target weight concept","volume":"39","author":"Waller","year":"2023","journal-title":"Nephrol Dial Transplant"},{"key":"2026090404411530800_bib22","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1063\/1.1750906","article-title":"Dispersion and absorption in dielectrics I. Alternating current characteristics","volume":"9","author":"Cole","year":"1941","journal-title":"J Chem Phys"},{"key":"2026090404411530800_bib23","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1088\/0967-3334\/27\/9\/012","article-title":"Body fluid volume determination via body composition spectroscopy in health and disease","volume":"27","author":"Moissl","year":"2006","journal-title":"Physiol Meas"},{"key":"2026090404411530800_bib24","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1093\/ajcn\/85.1.80","article-title":"A whole-body model to distinguish excess fluid from the hydration of major body tissues","volume":"85","author":"Chamney","year":"2007","journal-title":"Am J Clin Nutr"},{"key":"2026090404411530800_bib25","doi-asserted-by":"publisher","first-page":"4441","DOI":"10.1038\/s41598-018-21226-y","article-title":"Bioimpedance-defined overhydration predicts survival in end stage kidney failure (ESKF): systematic review and subgroup meta-analysis","volume":"8","author":"Tabinor","year":"2018","journal-title":"Sci Rep"},{"key":"2026090404411530800_bib26","doi-asserted-by":"publisher","first-page":"1832","DOI":"10.1093\/ndt\/gfy083","article-title":"Greater fluid overload and lower interdialytic weight gain are independently associated with mortality in a large international hemodialysis population","volume":"33","author":"Hecking","year":"2018","journal-title":"Nephrol Dial Transplant"},{"key":"2026090404411530800_bib27","doi-asserted-by":"publisher","first-page":"101217","DOI":"10.1016\/j.xkme.2025.101217","article-title":"Fluid management based on bioimpedance, blood volume, and patient reports: a quality improvement project in maintenance hemodialysis","volume":"8","author":"Mussnig","year":"2025","journal-title":"Kidney Med"},{"key":"2026090404411530800_bib28","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/s41687-026-01003-6","article-title":"Reduction of pruritus and depression using longitudinal patient-reported outcome measures in hemodialysis: a quality improvement project","volume":"10","author":"Naar","year":"2026","journal-title":"J Patient Rep Outcomes"},{"key":"2026090404411530800_bib29","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1097\/MBP.0b013e328338892f","article-title":"Validation of the mobil-O-Graph: 24 h-blood pressure measurement device","volume":"15","author":"Wei","year":"2010","journal-title":"Blood Press Monit"},{"key":"2026090404411530800_bib30","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1097\/MBP.0b013e328339be38","article-title":"Evaluation of the Mobil-O-Graph new generation ABPM device using the ESH criteria","volume":"15","author":"Franssen","year":"2010","journal-title":"Blood Press Monit"},{"key":"2026090404411530800_bib31","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1161\/HYPERTENSIONAHA.111.176313","article-title":"Validation of a brachial cuff-based method for estimating central systolic blood pressure","volume":"58","author":"Weber","year":"2011","journal-title":"Hypertension"},{"key":"2026090404411530800_bib32","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1097\/MBP.0b013e3283614168","article-title":"Oscillometric estimation of aortic pulse wave velocity: comparison with intra-aortic catheter measurements","volume":"18","author":"Hametner","year":"2013","journal-title":"Blood Press Monit"},{"key":"2026090404411530800_bib33","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.cmpb.2012.10.005","article-title":"Wave reflection quantification based on pressure waveforms alone\u2014methods, comparison, and clinical covariates","volume":"109","author":"Hametner","year":"2013","journal-title":"Comput Methods Programs Biomed"},{"key":"2026090404411530800_bib34","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/j.ijcard.2013.08.079","article-title":"Non-invasive 24 hour ambulatory monitoring of aortic wave reflection and arterial stiffness by a novel oscillometric device: the first feasibility and reproducibility study","volume":"169","author":"Papaioannou","year":"2013","journal-title":"Int J Cardiol"},{"key":"2026090404411530800_bib35","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1159\/000367791","article-title":"Evaluation of a novel brachial cuff-based oscillometric method for estimating central systolic pressure in hemodialysis patients","volume":"40","author":"Sarafidis","year":"2014","journal-title":"Am J Nephrol"},{"key":"2026090404411530800_bib36","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1161\/HYPERTENSIONAHA.112.194571","article-title":"Wave reflections, assessed with a novel method for pulse wave separation, are associated with end-organ damage and clinical outcomes","volume":"60","author":"Weber","year":"2012","journal-title":"Hypertension"},{"key":"2026090404411530800_bib37","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.ijcard.2013.11.039","article-title":"Reservoir and excess pressures predict cardiovascular events in high-risk patients","volume":"171","author":"Hametner","year":"2014","journal-title":"Int J Cardiol"},{"key":"2026090404411530800_bib38","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1093\/ajh\/hpz136","article-title":"Determinants of increased central excess pressure in dialysis: role of dialysis modality and arteriovenous fistula","volume":"33","author":"Par\u00e9","year":"2020","journal-title":"Am J Hypertens"},{"key":"2026090404411530800_bib39","doi-asserted-by":"publisher","first-page":"e0179938","DOI":"10.1371\/journal.pone.0179938","article-title":"Wave intensity of aortic root pressure as diagnostic marker of left ventricular systolic dysfunction","volume":"12","author":"Hametner","year":"2017","journal-title":"PLoS One"},{"key":"2026090404411530800_bib40","doi-asserted-by":"publisher","first-page":"sfae172","DOI":"10.1093\/ckj\/sfae172","article-title":"Measures of wave intensity as a non-invasive surrogate for cardiac function predicts mortality in haemodialysis patients","volume":"17","author":"Mayer","year":"2024","journal-title":"Clin Kidney J"},{"key":"2026090404411530800_bib41","doi-asserted-by":"publisher","first-page":"sfaf199","DOI":"10.1093\/ckj\/sfaf199","article-title":"Longitudinal patterns of fluid overload, blood volume and vascular refilling: a prospective study in patients on maintenance hemodialysis","volume":"18","author":"Mussnig","year":"2025","journal-title":"Clin Kidney J"},{"key":"2026090404411530800_bib42","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1038\/ki.1984.227","article-title":"Plasma volume recovery after ultrafiltration in patients with chronic renal failure","volume":"26","author":"Koomans","year":"1984","journal-title":"Kidney Int"},{"key":"2026090404411530800_bib43","doi-asserted-by":"publisher","first-page":"F303","DOI":"10.1152\/ajprenal.00575.2007","article-title":"Arterial stiffness and interdialytic weight gain influence ambulatory blood pressure patterns in hemodialysis patients","volume":"294","author":"Agarwal","year":"2008","journal-title":"Am J Physiol Renal Physiol"},{"key":"2026090404411530800_bib44","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1159\/000353104","article-title":"Significance of interdialytic weight gain versus chronic volume overload: consensus opinion","volume":"38","author":"Hecking","year":"2013","journal-title":"Am J Nephrol"},{"key":"2026090404411530800_bib45","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1159\/000170314","article-title":"Influence of the hydration state on blood pressure values in a group of patients on regular maintenance hemodialysis","volume":"15","author":"Dionisio","year":"1997","journal-title":"Blood Purif"},{"key":"2026090404411530800_bib46","first-page":"29","article-title":"Importance of volume factors in dialysis related hypertension","volume":"48","author":"Lins","year":"1997","journal-title":"Clin Nephrol"},{"key":"2026090404411530800_bib47","doi-asserted-by":"publisher","first-page":"1450","DOI":"10.1093\/ckj\/sfaa159","article-title":"The effects of extracellular volume and intradialytic peripheral resistance changes on ambulatory blood pressure in hemodialysis patients with and without recurrent intradialytic hypertension","volume":"14","author":"McAdams","year":"2021","journal-title":"Clin Kidney J"},{"key":"2026090404411530800_bib48","doi-asserted-by":"publisher","first-page":"e13292","DOI":"10.1111\/eci.13292","article-title":"Prevalence and control of hypertension among patients on haemodialysis","volume":"50","author":"Tsikliras","year":"2020","journal-title":"Eur J Clin Invest"},{"key":"2026090404411530800_bib49","doi-asserted-by":"publisher","first-page":"e0341843","DOI":"10.1371\/journal.pone.0341843","article-title":"Bioimpedance-assessed volume overload predicts interdialytic hypertension and disrupted circadian blood pressure rhythm in maintenance hemodialysis patients","volume":"21","author":"Wang","year":"2026","journal-title":"PLoS One"},{"key":"2026090404411530800_bib50","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1161\/HYPERTENSIONAHA.109.136366","article-title":"Volume-associated ambulatory blood pressure patterns in hemodialysis patients","volume":"54","author":"Agarwal","year":"2009","journal-title":"Hypertension"},{"key":"2026090404411530800_bib51","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1097\/MAT.0b013e318033cba7","article-title":"Fluid dynamics during hemodialysis in relationship to sodium gradient between dialysate and plasma","volume":"53","author":"Sarkar","year":"2007","journal-title":"ASAIO J"},{"key":"2026090404411530800_bib52","doi-asserted-by":"publisher","first-page":"e0209553","DOI":"10.1371\/journal.pone.0209553","article-title":"Model of fluid and solute shifts during hemodialysis with active transport of sodium and potassium","volume":"13","author":"Pietribiasi","year":"2018","journal-title":"PLoS One"},{"key":"2026090404411530800_bib53","doi-asserted-by":"publisher","first-page":"7188","DOI":"10.3390\/jcm14207188","article-title":"Linking intradialytic blood volume dynamics to extracellular fluid status: toward personalized fluid assessment in hemodialysis","volume":"14","author":"Russwurm","year":"2025","journal-title":"J Clin Med"}],"container-title":["Clinical Kidney Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ckj\/advance-article-pdf\/doi\/10.1093\/ckj\/sfag273\/70619148\/sfag273.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ckj\/article-pdf\/19\/9\/sfag273\/70619148\/sfag273.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ckj\/article-pdf\/19\/9\/sfag273\/70619148\/sfag273.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T08:41:23Z","timestamp":1788511283000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ckj\/article\/doi\/10.1093\/ckj\/sfag273\/8759702"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,12]]},"references-count":53,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026,9,1]]}},"URL":"https:\/\/doi.org\/10.1093\/ckj\/sfag273","relation":{},"ISSN":["2048-8505","2048-8513"],"issn-type":[{"value":"2048-8505","type":"print"},{"value":"2048-8513","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,9]]},"published":{"date-parts":[[2026,8,12]]},"article-number":"sfag273"}}