{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T16:39:33Z","timestamp":1782319173215,"version":"3.54.5"},"reference-count":30,"publisher":"Oxford University Press (OUP)","issue":"3","license":[{"start":{"date-parts":[[2025,1,20]],"date-time":"2025-01-20T00:00:00Z","timestamp":1737331200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"funder":[{"name":"Selcuk University Scientific Research Projects Coordination","award":["24401140"],"award-info":[{"award-number":["24401140"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Objectives<\/jats:title>\n                  <jats:p>Due to the increasing use of cone-beam CT (CBCT) in dentistry and considering the effects of radiation on radiosensitive organs, the aim of this study was to investigate the effect of shielding on absorbed dose of eyes, thyroid, and breasts in scans conducted with different parameters using 2 different fields of view (FOV).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>Dose measurements were calculated on a tissue-equivalent female phantom by repeating each scanning parameter 3 times and placing at least 2 thermoluminescent dosimeters (TLD) on each organ, with the averages then taken. The same CBCT scans were performed in 2 different FOV with shielding including thyroid collar, radiation safety glasses, and lead apron and without shielding. The differences between them were analysed statistically. Descriptive statistics and the Wilcoxon test were used for data analysis.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>The difference between measurements with and without shielding was statistically significant for all scans (P\u2009&amp;lt;\u2009.001). The dose reduction associated with the use of shielding ranged from 26.81% to 52.95%. The dose related to the FOV has shown a significant increase, ranging from 8.30% to 623.54%, due to both the variation in the area affected by the primary beam on the organs and changes in the amount of radiation.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>There are significant differences in the absorbed dose depending on shielding and FOV usage. Therefore, the CBCT imaging protocol should be optimized by the operator, and special attention should be paid to the use of thyroid collars and radiation safety glasses, considering their effects on image quality.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/dmfr\/twaf007","type":"journal-article","created":{"date-parts":[[2025,1,20]],"date-time":"2025-01-20T18:27:28Z","timestamp":1737397648000},"page":"231-238","source":"Crossref","is-referenced-by-count":6,"title":["Investigation of the effect of thyroid collar, radiation safety glasses, and lead apron on radiation dose in cone beam CT"],"prefix":"10.1093","volume":"54","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8043-288X","authenticated-orcid":false,"given":"Derya","family":"\u0130\u00e7\u00f6z","sequence":"first","affiliation":[{"name":"Faculty of Dentistry, Department of Oral and Maxillofacial Radiology, Selcuk University , Konya 42130,","place":["Turkey"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6773-3132","authenticated-orcid":false,"given":"Osman Vefa","family":"G\u00fcl","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Department of Radiation Oncology, Selcuk University , Konya 42130,","place":["Turkey"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2025,1,20]]},"reference":[{"key":"2025030423235321000_twaf007-B1","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1016\/j.cden.2018.03.002","article-title":"Cone beam computed tomography","volume":"62","author":"Nasseh","year":"2018","journal-title":"Dent Clin North Am"},{"key":"2025030423235321000_twaf007-B2","doi-asserted-by":"publisher","first-page":"179","DOI":"10.5624\/isd.2019.49.3.179","article-title":"New evolution of cone-beam computed tomography in dentistry: combining digital technologies","volume":"49","author":"Jain","year":"2019","journal-title":"Imaging Sci Dent."},{"key":"2025030423235321000_twaf007-B3","doi-asserted-by":"publisher","first-page":"263","DOI":"10.5624\/isd.2015.45.4.263","article-title":"Cone-beam computed tomography: time to move from ALARA to ALADA","volume":"45","author":"Jaju","year":"2015","journal-title":"Imaging Sci Dent."},{"key":"2025030423235321000_twaf007-B4","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.oooo.2019.11.012","article-title":"Dose reduction in head and neck organs through shielding and application of different scanning parameters in cone beam computed tomography: an effective dose study using an adult male anthropomorphic phantom","volume":"130","author":"Attaia","year":"2020","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol."},{"key":"2025030423235321000_twaf007-B5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s13244-014-0379-4","article-title":"Dentomaxillofacial imaging with panoramic views and cone beam CT","volume":"6","author":"Suomalainen","year":"2015","journal-title":"Insights Imaging."},{"key":"2025030423235321000_twaf007-B6","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1097\/HP.0000000000001138","article-title":"Trends in estimated thyroid, salivary gland, brain, and eye lens doses from intraoral dental radiography over seven decades (1940 to 2009)","volume":"118","author":"Fontana","year":"2020","journal-title":"Health Phys."},{"key":"2025030423235321000_twaf007-B7","doi-asserted-by":"publisher","first-page":"447","DOI":"10.3109\/02841861003705778","article-title":"Dental X-rays and the risk of thyroid cancer: a case-control study","volume":"49","author":"Memon","year":"2010","journal-title":"Acta Oncol."},{"key":"2025030423235321000_twaf007-B8","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1186\/1471-2407-12-157","article-title":"Cancer and non-cancer brain and eye effects of chronic low-dose ionizing radiation exposure","volume":"12","author":"Picano","year":"2012","journal-title":"BMC Cancer."},{"key":"2025030423235321000_twaf007-B9","doi-asserted-by":"publisher","first-page":"1675","DOI":"10.1093\/annonc\/mdt016","article-title":"Dental diagnostic X-ray exposure and risk of benign and malignant brain tumors","volume":"24","author":"Lin","year":"2013","journal-title":"Ann Oncol."},{"key":"2025030423235321000_twaf007-B10","doi-asserted-by":"publisher","first-page":"151","DOI":"10.14219\/jada.archive.1990.0026","article-title":"Brain and salivary gland tumors related to prior dental radiography: implications for current practice","volume":"120","author":"Preston-Martin","year":"1990","journal-title":"J Am Dent Assoc."},{"key":"2025030423235321000_twaf007-B11","doi-asserted-by":"publisher","first-page":"e2018017","DOI":"10.5620\/eht.e2018017","article-title":"Health effects from exposure to dental diagnostic X-ray","volume":"33","author":"Hwang","year":"2018","journal-title":"Environ Health Toxicol."},{"key":"2025030423235321000_twaf007-B12","doi-asserted-by":"publisher","first-page":"826","DOI":"10.1016\/j.adaj.2023.06.015","article-title":"Patient shielding during dentomaxillofacial radiography: recommendations from the American Academy of Oral and Maxillofacial Radiology","volume":"154","author":"Benavides","year":"2023","journal-title":"J Am Dent Assoc."},{"key":"2025030423235321000_twaf007-B13","doi-asserted-by":"publisher","first-page":"153","DOI":"10.18502\/fbt.v6i3.1699","article-title":"Shielding in dental radiography: is it applied properly?","volume":"6","author":"Vahid","year":"2019","journal-title":"FBT"},{"key":"2025030423235321000_twaf007-B14","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1186\/s13244-021-01085-4","article-title":"European consensus on patient contact shielding","volume":"12","author":"Hiles","year":"2021","journal-title":"Insights Imaging"},{"key":"2025030423235321000_twaf007-B15","doi-asserted-by":"publisher","first-page":"20150095","DOI":"10.1259\/dmfr.20150095","article-title":"Radiation exposure to foetus and breasts from dental X-ray examinations: effect of lead shields","volume":"45","author":"Kelaranta","year":"2016","journal-title":"Dentomaxillofac Radiol."},{"key":"2025030423235321000_twaf007-B16","doi-asserted-by":"publisher","first-page":"20120260","DOI":"10.1259\/dmfr.20120260","article-title":"Effect of leaded glasses and thyroid shielding on cone beam CT radiation dose in an adult female phantom","volume":"42","author":"Goren","year":"2013","journal-title":"Dentomaxillofac Radiol."},{"key":"2025030423235321000_twaf007-B17","doi-asserted-by":"publisher","first-page":"1314","DOI":"10.1089\/thy.2024.0274","article-title":"Reflections on the American Academy of Oral and Maxillofacial Radiology and the American Dental Association Guidelines for patient shielding during dentomaxillofacial radiography","volume":"34","author":"Schneider","year":"2024","journal-title":"Thyroid"},{"key":"2025030423235321000_twaf007-B18","doi-asserted-by":"publisher","first-page":"20190014","DOI":"10.1259\/dmfr.20190014","article-title":"Thyroid shielding in cone beam computed tomography: recommendations towards appropriate use","volume":"48","author":"Pauwels","year":"2019","journal-title":"Dentomaxillofac Radiol."},{"key":"2025030423235321000_twaf007-B19","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1097\/HP.0000000000000676","article-title":"Influence of a commercial lead apron on patient skin dose delivered during oral and maxillofacial examinations under cone beam computed tomography (CBCT)","volume":"113","author":"Schulze","year":"2017","journal-title":"Health Phys."},{"key":"2025030423235321000_twaf007-B20","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1093\/rpd\/ncw275","article-title":"Influence of lead apron shielding on absorbed doses from cone-beam computed tomography","volume":"175","author":"Rottke","year":"2017","journal-title":"Radiat Prot Dosimetry"},{"key":"2025030423235321000_twaf007-B21","doi-asserted-by":"publisher","first-page":"20210316","DOI":"10.1259\/dmfr.20210316","article-title":"Effect of field of view (FOV) positioning and shielding on radiation dose in paediatric CBCT","volume":"51","author":"Vogiatzi","year":"2022","journal-title":"Dentomaxillofac Radiol."},{"key":"2025030423235321000_twaf007-B22","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/j.ejrad.2005.05.011","article-title":"Dose reduction in maxillofacial imaging using low dose cone beam CT","volume":"56","author":"Tsiklakis","year":"2005","journal-title":"Eur J Radiol."},{"key":"2025030423235321000_twaf007-B23","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1186\/s12903-018-0592-5","article-title":"Estimated radiation risk of cancer from dental cone-beam computed tomography imaging in orthodontics patients","volume":"18","author":"Yeh","year":"2018","journal-title":"BMC Oral Health."},{"key":"2025030423235321000_twaf007-B24","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1016\/j.tripleo.2011.04.041","article-title":"Significant reduction in dental cone beam computed tomography (CBCT) eye dose through the use of leaded glasses","volume":"112","author":"Prins","year":"2011","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod."},{"key":"2025030423235321000_twaf007-B25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2012.02.001","article-title":"ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs\u2014threshold doses for tissue reactions in a radiation protection context","volume":"41","author":"Stewart","year":"2012","journal-title":"Ann ICRP."},{"key":"2025030423235321000_twaf007-B26","author":"Bethesda","year":"1989"},{"key":"2025030423235321000_twaf007-B27","first-page":"1","article-title":"The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103","volume":"37","year":"2007","journal-title":"Ann ICRP"},{"key":"2025030423235321000_twaf007-B28","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/j.ejrad.2010.11.028","article-title":"Effective dose range for dental cone beam computed tomography scanners","volume":"81","author":"Pauwels","year":"2012","journal-title":"Eur J Radiol."},{"key":"2025030423235321000_twaf007-B29","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.61872\/sdj-2014-11-01","article-title":"SADMFR guidelines for the use of cone-beam computed tomography\/digital volume tomography","volume":"124","author":"Dula","year":"2014","journal-title":"Swiss Dent J."},{"key":"2025030423235321000_twaf007-B30","doi-asserted-by":"crossref","DOI":"10.1002\/suco.202400519","article-title":"A comprehensive review of radiation shielding concrete: properties, design, evaluation, and applications","author":"Barbhuiya","year":"2024","journal-title":"Struct Concr"}],"container-title":["Dentomaxillofacial Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/dmfr\/advance-article-pdf\/doi\/10.1093\/dmfr\/twaf007\/61520715\/twaf007.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/dmfr\/article-pdf\/54\/3\/231\/61520715\/twaf007.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/dmfr\/article-pdf\/54\/3\/231\/61520715\/twaf007.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,4]],"date-time":"2025-03-04T23:23:59Z","timestamp":1741130639000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/dmfr\/article\/54\/3\/231\/7964719"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,20]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,3,1]]}},"URL":"https:\/\/doi.org\/10.1093\/dmfr\/twaf007","relation":{},"ISSN":["0250-832X","1476-542X"],"issn-type":[{"value":"0250-832X","type":"print"},{"value":"1476-542X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2025,3]]},"published":{"date-parts":[[2025,1,20]]}}}