{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T11:49:28Z","timestamp":1753876168140,"version":"3.41.2"},"reference-count":27,"publisher":"Oxford University Press (OUP)","issue":"12","license":[{"start":{"date-parts":[[2024,9,30]],"date-time":"2024-09-30T00:00:00Z","timestamp":1727654400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"funder":[{"name":"Drug Regulatory Science Project of Gansu Provincial Drug Administration"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,11,28]]},"abstract":"<jats:title>Summary<\/jats:title>\n               <jats:p>Twenty-four-hour pH-impedance monitoring is an important diagnostic approach for gastroesophageal reflux disease (GERD). Reflux monitoring results cannot be synchronized with ambulatory motility imaging of the esophageal sphincter. We have designed a novel wired transmission pH-combined photographic catheter (WT-CPC) for the synchronous acquisition of reflux image and pH. Different patterns of reflux events were simulated to perform in a porcine gastroesophageal reflux model in vitro. The live porcine model of gastroesophageal reflux was established in three Bama pigs. Monitoring was conducted with the WT-CPC and pH-impedance catheter simultaneously. Measurements included the number and proportion of reflux events, as well as acid exposure time (AET). The detection rates of WT-CPC for distal and horizontal acid reflux events were significantly higher compared to those of pH-impedance catheters (100% vs. 14.29%, 100% vs. 57.14%, P\u2009&amp;lt;\u20090.05). There was no significant difference between the two methods in proximal acid reflux events (P\u2009=\u20090.217). Regarding mixed reflux events, WT-CPC exhibited higher detection rates for distal events than pH-impedance catheter (100% vs. 42.86%, P\u2009&amp;lt;\u20090.05). However, there was no significant difference between the two methods for proximal reflux events (P\u2009&amp;gt;\u20090.05). Both methods showed similar results for horizontal reflux events. A porcine gastroesophageal reflux model was successfully established and utilized for reflux monitoring. A total of 28 episodes of reflux were detected within 6.5\u00a0min. The detection rate achieved by WT-CPC for reflux events was significantly higher than that obtained by pH-impedance (100% vs. 78.57%, P\u2009=\u20090.023). The WT-CPC has demonstrated reflux monitoring capabilities in an isolated reflux organ model. It also showed good operability and performance in the porcine model. The WT-CPC holds promising potential to provide valuable diagnostic evidence for GERD.<\/jats:p>","DOI":"10.1093\/dote\/doae076","type":"journal-article","created":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T03:38:14Z","timestamp":1727753894000},"source":"Crossref","is-referenced-by-count":0,"title":["In vitro and in vivo evaluation of a novel wired transmission pH-combined photographic catheter for ambulatory gastroesophageal reflux monitoring (with videos)"],"prefix":"10.1093","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6106-265X","authenticated-orcid":false,"given":"Xiaoyu","family":"Hu","sequence":"first","affiliation":[{"name":"Department of Gastroenterology, Lanzhou University Second Hospital , Lanzhou, Gansu ,","place":["China"]},{"name":"Gansu Provincial Digestive Endoscopy Engineering Research Center , Lanzhou, Gansu ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bofu","family":"Tang","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Lanzhou University Second Hospital , Lanzhou, Gansu ,","place":["China"]},{"name":"Gansu Provincial Digestive Endoscopy Engineering Research Center , Lanzhou, Gansu ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yifan","family":"Zhang","sequence":"additional","affiliation":[{"name":"School of Information Science and Engineering, Lanzhou University , Lanzhou, Gansu ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinyong","family":"Hao","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Lanzhou University Second Hospital , Lanzhou, Gansu ,","place":["China"]},{"name":"Gansu Provincial Digestive Endoscopy Engineering Research Center , Lanzhou, Gansu ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9440-510X","authenticated-orcid":false,"given":"Jie","family":"Feng","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Lanzhou University Second Hospital , Lanzhou, Gansu ,","place":["China"]},{"name":"Gansu Provincial Digestive Endoscopy Engineering Research Center , Lanzhou, Gansu ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1196-9381","authenticated-orcid":false,"given":"Xiaojun","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology, Lanzhou University Second Hospital , Lanzhou, Gansu ,","place":["China"]},{"name":"Gansu Provincial Digestive Endoscopy Engineering Research Center , Lanzhou, Gansu ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2024,9,30]]},"reference":[{"key":"2024112912522789800_ref1","article-title":"Advances in the diagnosis and management of gastroesophageal reflux disease","volume":"371","author":"Katzka","year":"2020","journal-title":"BMJ"},{"key":"2024112912522789800_ref2","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1136\/gutjnl-2017-314722","article-title":"Modern diagnosis of GERD: the Lyon consensus","volume":"67","author":"Gyawali","year":"2018","journal-title":"Gut"},{"key":"2024112912522789800_ref3","doi-asserted-by":"crossref","first-page":"1314","DOI":"10.1016\/j.cgh.2020.03.057","article-title":"Untangling nonerosive reflux disease from functional heartburn","volume":"19","author":"Patel","year":"2021","journal-title":"Clin Gastroenterol Hepatol"},{"key":"2024112912522789800_ref4","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1136\/gutjnl-2020-321395","article-title":"Number of reflux episodes on pH-impedance monitoring associates with improved symptom outcome and treatment satisfaction in gastro-oesophageal reflux disease (GERD) patients with regurgitation","volume":"70","author":"Rogers","year":"2021","journal-title":"Gut"},{"key":"2024112912522789800_ref5","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.1136\/gutjnl-2020-322627","article-title":"Normal values and regional differences in oesophageal impedance-pH metrics: a consensus analysis of impedance-pH studies from around the world","volume":"70","author":"Sifrim","year":"2021","journal-title":"Gut"},{"key":"2024112912522789800_ref6","doi-asserted-by":"crossref","first-page":"1976","DOI":"10.1016\/j.cgh.2020.09.002","article-title":"Inter-reviewer variability in interpretation of pH-impedance studies: the Wingate consensus","volume":"19","author":"Gyawali","year":"2021","journal-title":"Clin Gastroenterol Hepatol"},{"key":"2024112912522789800_ref7","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1177\/01945998211006929","article-title":"Comparison between manual and automated analyses in multichannel intraluminal impedance: pH monitoring for laryngopharyngeal reflux","volume":"166","author":"Kang","year":"2022","journal-title":"Otolaryngology-Head and Neck Surgery"},{"key":"2024112912522789800_ref8","doi-asserted-by":"crossref","first-page":"2918","DOI":"10.1038\/ajg.2009.506","article-title":"Impact of measurement of esophageal acid exposure close to the gastroesophageal junction on diagnostic accuracy and event-symptom correlation: a prospective study using wireless dual pH monitoring","volume":"104","author":"Bansal","year":"2009","journal-title":"Official journal of the American College of Gastroenterology| ACG"},{"key":"2024112912522789800_ref9","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1016\/j.cgh.2014.08.029","article-title":"Parameters on esophageal pH-impedance monitoring that predict outcomes of patients with gastroesophageal reflux disease","volume":"13","author":"Patel","year":"2015","journal-title":"Clin Gastroenterol Hepatol"},{"key":"2024112912522789800_ref10","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1038\/ajg.2016.256","article-title":"Esophageal impedance monitoring: clinical pearls and pitfalls","volume":"111","author":"Ravi","year":"2016","journal-title":"Official journal of the American College of Gastroenterology| ACG"},{"key":"2024112912522789800_ref11","doi-asserted-by":"crossref","first-page":"1607","DOI":"10.1023\/B:DDAS.0000043372.98660.82","article-title":"Proximal sensor data from routine dual-sensor esophageal pH monitoring is often inaccurate","volume":"49","author":"McCollough","year":"2004","journal-title":"Dig Dis Sci"},{"key":"2024112912522789800_ref12","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1007\/s11604-021-01210-9","article-title":"Assessment of esophagogastric junction morphology by dynamic real-time MRI: comparison of imaging features to high-resolution manometry","volume":"40","author":"Biggemann","year":"2022","journal-title":"Jpn J Radiol"},{"key":"2024112912522789800_ref13","doi-asserted-by":"crossref","first-page":"109265","DOI":"10.1016\/j.ejrad.2020.109265","article-title":"Assessment of esophageal motility disorders by real-time MRI","volume":"132","author":"Biggemann","year":"2020","journal-title":"Eur J Radiol"},{"key":"2024112912522789800_ref14","doi-asserted-by":"crossref","first-page":"108856","DOI":"10.1016\/j.ejrad.2020.108856","article-title":"Real-time MRI for dynamic assessment of gastroesophageal reflux disease: comparison to pH-metry and impedance","volume":"125","author":"Hosseini","year":"2020","journal-title":"Eur J Radiol"},{"key":"2024112912522789800_ref15","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1111\/dote.12326","article-title":"Belching during gastroscopy and its association with gastroesophageal reflux disease","volume":"29","author":"Lee","year":"2016","journal-title":"Dis Esophagus"},{"key":"2024112912522789800_ref16","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.gassur.2005.09.005","article-title":"Gastroesophageal and pharyngeal reflux detection using impedance and 24-hour pH monitoring in asymptomatic subjects: defining the normal environment","volume":"10","author":"Oelschlager","year":"2006","journal-title":"J Gastrointest Surg"},{"key":"2024112912522789800_ref17","doi-asserted-by":"crossref","first-page":"e14671","DOI":"10.1111\/nmo.14671","article-title":"A perspective on the clinical relevance of weak or nonacid reflux","volume":"35","author":"Jodorkovsky","year":"2023","journal-title":"Neurogastroenterology & Motility"},{"key":"2024112912522789800_ref18","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1136\/gut.44.4.476","article-title":"The effect of hiatus hernia on gastro-oesophageal junction pressure","volume":"44","author":"Kahrilas","year":"1999","journal-title":"Gut"},{"key":"2024112912522789800_ref19","first-page":"1380","article-title":"Redefining gastroesophageal reflux (GER)","volume":"17","author":"Balaji","year":"2003","journal-title":"Surg Endosc Other Interv Tech"},{"key":"2024112912522789800_ref20","doi-asserted-by":"crossref","first-page":"2147","DOI":"10.1023\/B:DDAS.0000004518.98825.6c","article-title":"Esophagitis impairs esophageal smooth muscle reactivity in the rat model: an in vitro study","volume":"48","author":"Tugay","year":"2003","journal-title":"Dig Dis Sci"},{"key":"2024112912522789800_ref21","doi-asserted-by":"crossref","first-page":"621","DOI":"10.2214\/ajr.162.3.8109509","article-title":"Detection of gastroesophageal reflux: value of barium studies compared with 24-hr pH monitoring","volume":"162","author":"Thompson","year":"1994","journal-title":"AJR Am J Roentgenol"},{"key":"2024112912522789800_ref22","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1038\/ajg.2014.25","article-title":"Abnormal structure and function of the esophagogastric junction and proximal stomach in gastroesophageal reflux disease","volume":"109","author":"Curcic","year":"2014","journal-title":"Official journal of the American College of Gastroenterology| ACG"},{"key":"2024112912522789800_ref23","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1111\/nyas.14501","article-title":"Pathophysiology and treatment options for gastroesophageal reflux disease: looking beyond acid","volume":"1486","author":"Sharma","year":"2021","journal-title":"Ann N Y Acad Sci"},{"key":"2024112912522789800_ref24","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1016\/j.jcmgh.2018.10.017","article-title":"Gastroesophageal reflux induces protein adducts in the esophagus","volume":"7","author":"Gokulan","year":"2019","journal-title":"Cell Mol Gastroenterol Hepatol"},{"key":"2024112912522789800_ref25","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1007\/s00535-021-01815-x","article-title":"Potential roles of gastroesophageal reflux in patients with superficial esophageal squamous cell carcinoma without major causative risk factors","volume":"56","author":"Fukuchi","year":"2021","journal-title":"J Gastroenterol"},{"key":"2024112912522789800_ref26","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1111\/apt.16481","article-title":"Novel impedance-pH parameters are associated with proton pump inhibitor response in patients with inconclusive diagnosis of gastro-oesophageal reflux disease according to Lyon consensus","volume":"54","author":"Ribolsi","year":"2021","journal-title":"Aliment Pharmacol Ther"},{"key":"2024112912522789800_ref27","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1007\/978-3-031-39199-6_14","volume-title":"The SAGES Manual of Physiologic Evaluation of Foregut Diseases","author":"Chen","year":"2023"}],"container-title":["Diseases of the Esophagus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/dote\/article-pdf\/37\/12\/doae076\/60885187\/doae076.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/dote\/article-pdf\/37\/12\/doae076\/60885187\/doae076.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,29]],"date-time":"2024-11-29T12:53:05Z","timestamp":1732884785000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/dote\/article\/doi\/10.1093\/dote\/doae076\/7796695"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,30]]},"references-count":27,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,9,30]]},"published-print":{"date-parts":[[2024,11,28]]}},"URL":"https:\/\/doi.org\/10.1093\/dote\/doae076","relation":{},"ISSN":["1120-8694","1442-2050"],"issn-type":[{"type":"print","value":"1120-8694"},{"type":"electronic","value":"1442-2050"}],"subject":[],"published-other":{"date-parts":[[2024,12]]},"published":{"date-parts":[[2024,9,30]]},"article-number":"doae076"}}