{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T01:25:57Z","timestamp":1777253157754,"version":"3.51.4"},"reference-count":11,"publisher":"Oxford University Press (OUP)","issue":"3","license":[{"start":{"date-parts":[[2020,4,5]],"date-time":"2020-04-05T00:00:00Z","timestamp":1586044800000},"content-version":"vor","delay-in-days":1,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Background<\/jats:title>\n                  <jats:p>Aortopulmonary window is a congenital heart disease requiring a surgical approach to achieve a complete correction.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Case summary<\/jats:title>\n                  <jats:p>We report on a case of a young female symptomatic adult patient with a significant aortopulmonary window. The patients refused surgical approach and since the defect was far enough from the pulmonary and aortic valve a percutaneous approach was proposed. The large aortopulmonary window was closed effectively with an Amplatzer Muscular Septal Occluder device (Abbott, Plymouth, MN, USA). At 1-year follow-up, the device was in a good position with no residual shunt.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Discussion<\/jats:title>\n                  <jats:p>Transcatheter closure of an aortopulmonary window is an effective and safe procedure in specific anatomic defects.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/ehjcr\/ytaa059","type":"journal-article","created":{"date-parts":[[2020,4,4]],"date-time":"2020-04-04T23:25:17Z","timestamp":1586042717000},"page":"1-4","source":"Crossref","is-referenced-by-count":10,"title":["Percutaneous closure of an aortopulmonary window in a young adult patient: a case report of transcatheter closure with an occluder device"],"prefix":"10.1093","volume":"4","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0583-5221","authenticated-orcid":false,"given":"Mario","family":"Giordano","sequence":"first","affiliation":[{"name":"Department of Congenital Cardiology and Cardiac Surgery, IRCCS Policlinico San Donato, San Donato Milanese, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1288-0108","authenticated-orcid":false,"given":"Gianfranco","family":"Butera","sequence":"first","affiliation":[{"name":"Department of Congenital Cardiology and Cardiac Surgery, IRCCS Policlinico San Donato, San Donato Milanese, Italy"},{"name":"King\u2019s College London, London, UK"},{"name":"Department of Paediatric Cardiology, Evelina Children\u2019s Hospital, London, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2020,4,4]]},"reference":[{"key":"2020062620235816500_ytaa059-B1","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1007\/s00246-002-0307-0","article-title":"Closure of aortopulmonary window with Amplatzer Duct Occluder device","volume":"24","author":"Atiq","year":"2003","journal-title":"Pediatr Cardiol"},{"key":"2020062620235816500_ytaa059-B2","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1136\/hrt.77.5.479","article-title":"Transcatheter umbrella closure of aorto-pulmonary window","volume":"77","author":"Tulloh","year":"1997","journal-title":"Heart"},{"key":"2020062620235816500_ytaa059-B3","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1111\/j.1747-0803.2006.00055.x","article-title":"Transcatheter closure of distal aortopulmonary window using Amplatzer device","volume":"1","author":"Sivakumar","year":"2006","journal-title":"Congenit Heart Dis"},{"key":"2020062620235816500_ytaa059-B4","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1007\/s00246-012-0325-5","article-title":"Closure of an aortopulmonary window using the Amplatzer Duct Occluder II","volume":"34","author":"Noonan","year":"2013","journal-title":"Pediatr Cardiol"},{"key":"2020062620235816500_ytaa059-B5","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1017\/S1047951116002134","article-title":"Percutaneous closure of an aortopulmonary window using Amplatzer Duct Occluder II: additional sizes: the first reported case","volume":"27","author":"Fiszer","year":"2017","journal-title":"Cardiol Young"},{"key":"2020062620235816500_ytaa059-B6","first-page":"11","article-title":"Transcatheter closure of symptomatic aortopulmonary window in an infant","volume":"10","author":"Pillekamp","year":"2008","journal-title":"Images Paediatr Cardiol"},{"key":"2020062620235816500_ytaa059-B7","doi-asserted-by":"crossref","first-page":"61","DOI":"10.5530\/jcdr.2017.2.14","article-title":"Transcatheter closure of a large aortopulmonary window with pulmonary arterial hypertension: lessons to be learnt","volume":"8","author":"Arora","year":"2017","journal-title":"J Cardiovasc Dis Res"},{"key":"2020062620235816500_ytaa059-B8","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1159\/000475706","article-title":"Transcatheter treatment of aortopulmonary window with a symmetrical membranous ventricular septal occluder","volume":"138","author":"Xu","year":"2017","journal-title":"Cardiology"},{"key":"2020062620235816500_ytaa059-B9","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1532\/hsf.1301","article-title":"Transcatheter treatment of large aortopulmonary window: a case report","volume":"18","author":"Chen","year":"2015","journal-title":"Heart Surg Forum"},{"key":"2020062620235816500_ytaa059-B10","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1002\/ccd.23505","article-title":"Over-the-wire-technique device implantation","volume":"80","author":"Butera","year":"2012","journal-title":"Catheter Cardiovasc Interv"},{"key":"2020062620235816500_ytaa059-B11","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1002\/ccd.26369","article-title":"Goose-neck snare-assisted transcatheter ASD closure: a safety procedure for large and complex ASDs","volume":"87","author":"Butera","year":"2016","journal-title":"Catheter Cardiovasc Interv"}],"container-title":["European Heart Journal - Case Reports"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ehjcr\/article-pdf\/4\/3\/1\/33434620\/ytaa059.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/ehjcr\/article-pdf\/4\/3\/1\/33434620\/ytaa059.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,27]],"date-time":"2020-06-27T08:02:12Z","timestamp":1593244932000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ehjcr\/article\/4\/3\/1\/5816045"}},"subtitle":[],"editor":[{"given":"Nikolaos","family":"Bonaros","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Esther","family":"Cambronero-Cortinas","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Arif","family":"Khan","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Cemil","family":"Izgi","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Carlos Minguito","family":"Carazo","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Ross","family":"Thomson","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2020,4,4]]},"references-count":11,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2020,4,4]]},"published-print":{"date-parts":[[2020,6,1]]}},"URL":"https:\/\/doi.org\/10.1093\/ehjcr\/ytaa059","relation":{},"ISSN":["2514-2119"],"issn-type":[{"value":"2514-2119","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2020,6]]},"published":{"date-parts":[[2020,4,4]]}}}