{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T11:49:56Z","timestamp":1753876196632,"version":"3.41.2"},"reference-count":10,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,2,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>The use of mechanical circulatory support (MCS) in acute myocardial infarction and cardiogenic shock (AMICS) complicated by biventricular failure is poorly discussed in the literature.<\/jats:p><\/jats:sec><jats:sec><jats:title>Case summary<\/jats:title><jats:p>We present successful treatment of a 52-year-old old man presenting with AMICS following cardiac arrest and prolonged CPR via a Bipella approach for biventricular support and restoration of haemodynamic stability.<\/jats:p><\/jats:sec><jats:sec><jats:title>Discussion<\/jats:title><jats:p>This case demonstrates the importance of understanding the role of MCS in the management of cardiogenic shock; the value of the cardiac power output and pulmonary artery pulsatility index as haemodynamic metrics to assess the cardiac function of a patient with cardiogenic shock; and the importance of a Bipella MCS approach in high inpatient morbidity and mortality AMICS with biventricular failure.<\/jats:p><\/jats:sec>","DOI":"10.1093\/ehjcr\/ytab040","type":"journal-article","created":{"date-parts":[[2021,2,12]],"date-time":"2021-02-12T19:36:19Z","timestamp":1613158579000},"source":"Crossref","is-referenced-by-count":4,"title":["Successful resuscitation of acute cardiogenic shock presenting as ventricular fibrillation via Bipella approach: a case report"],"prefix":"10.1093","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4393-7752","authenticated-orcid":false,"given":"Dominika M","family":"Zoltowska","sequence":"first","affiliation":[{"name":"UF Health Jacksonville, 655 West 8th Street 3rd Floor, Jacksonville, FL 32209, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yashwant","family":"Agrawal","sequence":"additional","affiliation":[{"name":"St. Joseph Mercy Oakland Hospital, 44405 Woodward Ave, Pontiac, MI 48341, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Yves R","family":"Nazroo","sequence":"additional","affiliation":[{"name":"St. Joseph Mercy Oakland Hospital, 44405 Woodward Ave, Pontiac, MI 48341, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8851-1619","authenticated-orcid":false,"given":"Kirit","family":"Patel","sequence":"additional","affiliation":[{"name":"St. Joseph Mercy Oakland Hospital, 44405 Woodward Ave, Pontiac, MI 48341, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2021,2,11]]},"reference":[{"key":"2021021106541560500_ytab040-B1","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.healun.2012.12.004","article-title":"Fifth INTERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients","volume":"32","author":"Kirklin","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"2021021106541560500_ytab040-B2","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1002\/ccd.28307","article-title":"Improved outcomes associated with the use of shock protocols: updates from the National Cardiogenic Shock Initiative","volume":"93","author":"Basir","year":"2019","journal-title":"Catheter Cardiovasc Interv"},{"key":"2021021106541560500_ytab040-B3","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1002\/ehf2.12274","article-title":"Full percutaneous biventricular support with two impella pumps: the Bi-Pella approach","volume":"5","author":"Pappalardo","year":"2018","journal-title":"ESC Heart Fail"},{"key":"2021021106541560500_ytab040-B4","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.jacc.2016.10.022","article-title":"Percutaneous mechanical circulatory support versus intra-aortic balloon pump in cardiogenic shock after acute myocardial infarction","volume":"69","author":"Ouweneel","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"2021021106541560500_ytab040-B5","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/s00059-016-4523-4","article-title":"ECMO in cardiac arrest and cardiogenic shock","volume":"42","author":"Napp","year":"2017","journal-title":"Herz"},{"key":"2021021106541560500_ytab040-B6","doi-asserted-by":"crossref","first-page":"e00495","DOI":"10.1161\/CIRCHEARTFAILURE.118.004905","article-title":"Venoarterial extracorporeal membrane oxygenation for cardiogenic shock and cardiac arrest","volume":"11","author":"Rao","year":"2018","journal-title":"Circ Heart Fail"},{"key":"2021021106541560500_ytab040-B7","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.jcrc.2017.10.011","article-title":"Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) for emergency cardiac support","volume":"44","author":"Sun","year":"2018","journal-title":"J Crit Care"},{"key":"2021021106541560500_ytab040-B8","doi-asserted-by":"crossref","first-page":"e006670","DOI":"10.1161\/JAHA.117.006670","article-title":"Acute biventricular mechanical circulatory support for cardiogenic shock","volume":"6","author":"Kuchibhotla","year":"2017","journal-title":"J Am Heart Assoc"},{"key":"2021021106541560500_ytab040-B9","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1002\/ccd.23309","article-title":"The pulmonary artery pulsatility index identifies severe right ventricular dysfunction in acute inferior myocardial infarction","volume":"80","author":"Korabathina","year":"2012","journal-title":"Catheter Cardiovasc Interv"},{"key":"2021021106541560500_ytab040-B10","doi-asserted-by":"crossref","first-page":"1549","DOI":"10.1016\/j.healun.2015.08.018","article-title":"Benefits of a novel percutaneous ventricular assist device for right heart failure: the prospective RECOVER RIGHT study of the Impella RP device","volume":"34","author":"Anderson","year":"2015","journal-title":"J Heart Lung Transplant"}],"container-title":["European Heart Journal - Case Reports"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ehjcr\/article-pdf\/5\/2\/ytab040\/36233931\/ytab040.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/ehjcr\/article-pdf\/5\/2\/ytab040\/36233931\/ytab040.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,21]],"date-time":"2023-10-21T03:40:32Z","timestamp":1697859632000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ehjcr\/article\/doi\/10.1093\/ehjcr\/ytab040\/6132784"}},"subtitle":[],"editor":[{"given":"Mohamed","family":"Farag","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Ying Xuan","family":"Gue","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Rami Riziq Yousef","family":"Abumuaileq","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Edwina","family":"McNaughton","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Kott","family":"Katharine","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2021,2,1]]},"references-count":10,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,2,4]]}},"URL":"https:\/\/doi.org\/10.1093\/ehjcr\/ytab040","relation":{},"ISSN":["2514-2119"],"issn-type":[{"type":"electronic","value":"2514-2119"}],"subject":[],"published-other":{"date-parts":[[2021,2,1]]},"published":{"date-parts":[[2021,2,1]]},"article-number":"ytab040"}}