{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T11:50:23Z","timestamp":1753876223450,"version":"3.41.2"},"reference-count":17,"publisher":"Oxford University Press (OUP)","issue":"11","license":[{"start":{"date-parts":[[2024,10,18]],"date-time":"2024-10-18T00:00:00Z","timestamp":1729209600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,11,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Background<\/jats:title>\n                  <jats:p>Pacemaker lead-induced tricuspid regurgitation is a common complication after cardiac implantable electronic device (CIED) implantation. Cardiac implantable electronic device lead removal is a challenge procedure.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Case summary<\/jats:title>\n                  <jats:p>A 72-year-old lady was admitted due to worsening heart failure. She had a history of permanent atrial fibrillation and had a permanent single-chamber pacemaker implanted 8 years ago due to complete heart block. Transthoracic echocardiography identified severe lead-related tricuspid regurgitation. The patient underwent successful lead extraction and received a new implantation of left bunch bundle area pacing. Transthoracic echocardiographic examination 2 days after the procedure showed a significant decrease of the tricuspid regurgitation. The patient also reported an improvement in heart failure symptoms.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Discussion<\/jats:title>\n                  <jats:p>Pacemaker lead-related tricuspid regurgitation introduces negative haemodynamic overload, carrying high risk for the development of heart failure and worse outcome. The present case shows a rapid relief of symptom and improvement of echocardiography findings, indicating the significance of mechanistic approach in the treatment of lead-related tricuspid mechanical interference.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/ehjcr\/ytae560","type":"journal-article","created":{"date-parts":[[2024,10,18]],"date-time":"2024-10-18T08:05:06Z","timestamp":1729238706000},"source":"Crossref","is-referenced-by-count":0,"title":["Pacemaker lead extraction saved a severe lead-induced tricuspid regurgitation: a case report"],"prefix":"10.1093","volume":"8","author":[{"given":"YuLiang","family":"Chai","sequence":"first","affiliation":[{"name":"Department of Cardiology, Jiangxi Provincial People\u2019s Hospital, The First Affiliated Hospital of Nanchang Medical College, No. 92, Aiguo Road, Nanchang City, Jiangxi Province 330006, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiang","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Jiangxi Provincial People\u2019s Hospital, The First Affiliated Hospital of Nanchang Medical College, No. 92, Aiguo Road, Nanchang City, Jiangxi Province 330006, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhiwen","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Jiangxi Provincial People\u2019s Hospital, The First Affiliated Hospital of Nanchang Medical College, No. 92, Aiguo Road, Nanchang City, Jiangxi Province 330006, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenjing","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Luoyang Central Hospital Affiliated to Zhengzhou University , 288 Zhongzhou Middle Road, Xi Gong Qu, Luo Yang City, He Nan Province 471000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuanqing","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Jiangxi Provincial People\u2019s Hospital, The First Affiliated Hospital of Nanchang Medical College, No. 92, Aiguo Road, Nanchang City, Jiangxi Province 330006, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2024,10,18]]},"reference":[{"key":"2024112719213312600_ytae560-B1","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.17219\/acem\/159531","article-title":"Lead-related tricuspid regurgitation and ventricle dysfunction: current management and future perspectives","volume":"32","author":"Chod\u00f3r-Rozwadowska","year":"2023","journal-title":"Adv Clin Exp Med"},{"key":"2024112719213312600_ytae560-B2","doi-asserted-by":"crossref","first-page":"2331","DOI":"10.1016\/j.jacc.2017.02.055","article-title":"Tricuspid valve dysfunction following pacemaker or cardioverter-defibrillator implantation","volume":"69","author":"Chang","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"2024112719213312600_ytae560-B3","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/j.cjca.2018.11.014","article-title":"Prospective study of tricuspid regurgitation associated with permanent leads after cardiac rhythm device implantation","volume":"35","author":"Van De Heyning","year":"2019","journal-title":"Can J Cardiol"},{"key":"2024112719213312600_ytae560-B4","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1093\/eurheartj\/ehad783","article-title":"Tricuspid valve disease and cardiac implantable electronic devices","volume":"45","author":"Andreas","year":"2024","journal-title":"Eur Heart J"},{"key":"2024112719213312600_ytae560-B5","doi-asserted-by":"crossref","first-page":"1672","DOI":"10.1016\/j.jacc.2005.02.037","article-title":"Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads","volume":"45","author":"Lin","year":"2005","journal-title":"J Am Coll Cardiol"},{"key":"2024112719213312600_ytae560-B6","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1136\/heartjnl-2013-304673","article-title":"Significant lead-induced tricuspid regurgitation is associated with poor prognosis at long-term follow-up","volume":"100","author":"Hoke","year":"2014","journal-title":"Heart"},{"key":"2024112719213312600_ytae560-B7","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1016\/j.echo.2022.08.004","article-title":"Tricuspid regurgitation related to cardiac implantable electronic devices: an integrative review","volume":"35","author":"Gelves-Meza","year":"2022","journal-title":"J Am Soc Echocardiog"},{"key":"2024112719213312600_ytae560-B8","doi-asserted-by":"crossref","first-page":"402","DOI":"10.5603\/CJ.2013.0099","article-title":"Lead dependent tricuspid dysfunction: analysis of the mechanism and management in patients referred for transvenous lead extraction","volume":"20","author":"Polewczyk","year":"2013","journal-title":"Cardiol J"},{"key":"2024112719213312600_ytae560-B9","doi-asserted-by":"crossref","first-page":"2058","DOI":"10.1016\/j.jcin.2023.04.018","article-title":"The impact and outcomes of right ventricular lead extraction in CIED-related tricuspid regurgitation","volume":"16","author":"Sorajja","year":"2023","journal-title":"JACC-Cardiovasc Inte"},{"key":"2024112719213312600_ytae560-B10","doi-asserted-by":"crossref","first-page":"2995","DOI":"10.1093\/eurheartj\/ehx080","article-title":"The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) registry of transvenous lead extraction outcomes","volume":"38","author":"Bongiorni","year":"2017","journal-title":"Eur Heart J"},{"key":"2024112719213312600_ytae560-B11","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/S0735-1097(22)01571-6","article-title":"Change in tricuspid regurgitation severity over time after transvenous pacemaker and defibrillator lead extraction","volume":"79","author":"Allard-Ratick","year":"2022","journal-title":"J Am Coll Cardiol"},{"key":"2024112719213312600_ytae560-B12","doi-asserted-by":"crossref","first-page":"1833","DOI":"10.1056\/NEJMoa2300525","article-title":"Transcatheter repair for patients with tricuspid regurgitation","volume":"388","author":"Sorajja","year":"2023","journal-title":"N Engl J Med"},{"key":"2024112719213312600_ytae560-B13","doi-asserted-by":"crossref","first-page":"1030997","DOI":"10.3389\/fcvm.2023.1030997","article-title":"Treatment of severe tricuspid regurgitation induced by permanent pacemaker lead: transcatheter tricuspid valve replacement with the guidance of 3-dimensional printing","volume":"10","author":"Mao","year":"2023","journal-title":"Front Cardiovasc Med"},{"key":"2024112719213312600_ytae560-B14","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1136\/heartjnl-2012-301627","article-title":"Long-term outcomes following infection of cardiac implantable electronic devices: a prospective matched cohort study","volume":"98","author":"Deharo","year":"2012","journal-title":"Heart"},{"key":"2024112719213312600_ytae560-B15","doi-asserted-by":"crossref","first-page":"e503","DOI":"10.1016\/j.hrthm.2017.09.001","article-title":"2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction","volume":"14","author":"Kusumoto","year":"2017","journal-title":"Heart Rhythm"},{"key":"2024112719213312600_ytae560-B16","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1093\/europace\/euy050","article-title":"2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS\/HRS\/LAHRS","volume":"20","author":"Bongiorni","year":"2018","journal-title":"Europace"},{"key":"2024112719213312600_ytae560-B17","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1093\/europace\/eus342","article-title":"Percutaneous pacemaker or implantable cardioverter-defibrillator lead removal in an attempt to improve symptomatic tricuspid regurgitation","volume":"15","author":"Nazmul","year":"2013","journal-title":"Europace"}],"container-title":["European Heart Journal - Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ehjcr\/advance-article-pdf\/doi\/10.1093\/ehjcr\/ytae560\/59844628\/ytae560.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ehjcr\/article-pdf\/8\/11\/ytae560\/60666145\/ytae560.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ehjcr\/article-pdf\/8\/11\/ytae560\/60666145\/ytae560.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,27]],"date-time":"2024-11-27T19:21:56Z","timestamp":1732735316000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ehjcr\/article\/doi\/10.1093\/ehjcr\/ytae560\/7825952"}},"subtitle":[],"editor":[{"given":"Christoph","family":"Sinning","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Piotr Nikodem","family":"Rudz\u00ednski","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Giulio","family":"Russo","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Ryaan","family":"El-Andari","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Marianna","family":"Garcia-Saldivia","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"Emmanouil","family":"Matzouranis","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2024,10,18]]},"references-count":17,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2024,11,1]]}},"URL":"https:\/\/doi.org\/10.1093\/ehjcr\/ytae560","relation":{},"ISSN":["2514-2119"],"issn-type":[{"type":"electronic","value":"2514-2119"}],"subject":[],"published-other":{"date-parts":[[2024,11]]},"published":{"date-parts":[[2024,10,18]]},"article-number":"ytae560"}}