{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:18:20Z","timestamp":1787008700182,"version":"build-2736575974"},"reference-count":16,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2019,4,29]],"date-time":"2019-04-29T00:00:00Z","timestamp":1556496000000},"content-version":"vor","delay-in-days":1,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"name":"Sergio S\u00e1enz"},{"name":"Heart Failure and Heart Transplantation Program"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Left ventricular assist devices (LVAD) are increasingly used in patients with advanced heart failure, many of whom have been or will be implanted with an implantable cardioverter defibrillator (ICD). Interaction between both devices is a matter of concern. Subcutaneous ICD (S-ICD) obtains its signals through subcutaneous vectors, which poses special challenges with regards to adequate performance following LVAD implantation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case summary<\/jats:title>\n                    <jats:p>We describe the case of a 24-year-old man implanted with an S-ICD because of idiopathic dilated cardiomyopathy, severe biventricular dysfunction, and self-limiting sustained ventricular tachycardias. After the implantation of a HeartMate 3\u2122 (Left Ventricular Assist System, Abbott) several months later, the S-ICD became useless because of inappropriate sensing due to electromagnetic interference and attenuation of QRS voltage.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>We reviewed the reported cases in PubMed about the concomitant use of S-ICD and LVAD. Seven case reports about the performance of S-ICD in patients with an LVAD were identified, with discordant results. From these articles, we analyse the potential causes for these differing results. Pump location and operating rates in LVAD, as well as changes in the subcutaneous-electrocardiogram detected by the S-ICD after LVAD implantation are related to sensing disturbances when used in the same patient.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ehjcr\/ytz057","type":"journal-article","created":{"date-parts":[[2019,4,29]],"date-time":"2019-04-29T06:16:22Z","timestamp":1556518582000},"source":"Crossref","is-referenced-by-count":12,"title":["Subcutaneous implantable cardioverter defibrillators in patients with left ventricular assist devices: case report and comprehensive review"],"prefix":"10.1093","volume":"3","author":[{"given":"Mar\u00eda","family":"L\u00f3pez-Gil","sequence":"first","affiliation":[{"name":"Cardiac Electrophysiology & Arrhythmia Unit, Cardiology Department, 12 de Octubre University Hospital, Avda de C\u00f3rdoba s\/n, Madrid, Spain"},{"name":"I+12 Investigation Institute, 12 de Octubre University Hospital, Avda de C\u00f3rdoba s\/n, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6674-7543","authenticated-orcid":false,"given":"Adolfo","family":"Fontenla","sequence":"additional","affiliation":[{"name":"Cardiac Electrophysiology & Arrhythmia Unit, Cardiology Department, 12 de Octubre University Hospital, Avda de C\u00f3rdoba s\/n, Madrid, Spain"},{"name":"I+12 Investigation Institute, 12 de Octubre University Hospital, Avda de C\u00f3rdoba s\/n, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5401-8324","authenticated-orcid":false,"given":"Juan F","family":"Delgado","sequence":"additional","affiliation":[{"name":"I+12 Investigation Institute, 12 de Octubre University Hospital, Avda de C\u00f3rdoba s\/n, Madrid, Spain"},{"name":"Heart Failure and Heart Transplantation Program, Cardiology Department, 12 de Octubre University Hospital, Avda de C\u00f3rdoba s\/n, Madrid, Spain"},{"name":"Facultad de Medicina, Universidad Complutense, Avda. de S\u00e9neca, 2 Madrid, Spain"},{"name":"CIBER CV, C\/ Melchor Fern\u00e1ndez Almagro 3, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Rodr\u00edguez-Mu\u00f1oz","sequence":"additional","affiliation":[{"name":"Cardiac Electrophysiology & Arrhythmia Unit, Cardiology Department, 12 de Octubre University Hospital, Avda de C\u00f3rdoba s\/n, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2019,4,28]]},"reference":[{"key":"2019091012152298500_ytz057-B1","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1016\/j.hrthm.2018.01.017","article-title":"Management of cardiac implantable electronic devices in the presence of left ventricular assist devices","volume":"15","author":"Parikh","year":"2018","journal-title":"Heart Rhythm"},{"key":"2019091012152298500_ytz057-B2","doi-asserted-by":"crossref","first-page":"1483","DOI":"10.1016\/j.jacc.2018.01.061","article-title":"Cardiac implantable electronic devices in patients with left ventricular assist systems","volume":"71","author":"Berg","year":"2018","journal-title":"J Am Coll Cardiol"},{"key":"2019091012152298500_ytz057-B3","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1056\/NEJMoa0909545","article-title":"An entirely subcutaneous implantable cardioverter\u2013defibrillator","volume":"363","author":"Bardy","year":"2010","journal-title":"N Engl J Med"},{"key":"2019091012152298500_ytz057-B4","doi-asserted-by":"crossref","first-page":"1499","DOI":"10.1016\/j.jacep.2017.08.017","article-title":"Long-term experience with the subcutaneous implantable cardioverter-defibrillator in teenagers and young adults","volume":"3","author":"Bettin","year":"2017","journal-title":"JACC Clin Electrophysiol"},{"key":"2019091012152298500_ytz057-B5","doi-asserted-by":"crossref","first-page":"e73","DOI":"10.1016\/j.hrthm.2017.10.036","article-title":"2017 AHA\/ACC\/HRS guideline for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death","volume":"15","author":"Al-Khatib","year":"2018","journal-title":"Heart Rhythm"},{"key":"2019091012152298500_ytz057-B6","doi-asserted-by":"crossref","first-page":"e32","DOI":"10.1161\/CIRCEP.113.000240","article-title":"Left ventricular assist device in a patient with a concomitant subcutaneous implantable cardioverter defibrillator","volume":"6","author":"Saeed","year":"2013","journal-title":"Circ Arrhythmia Electrophysiol"},{"key":"2019091012152298500_ytz057-B7","doi-asserted-by":"crossref","first-page":"140","DOI":"10.14503\/THIJ-14-4166","article-title":"Subcutaneous implantable cardioverter-defibrillator implantation in a patient with a left ventricular assist device already in place","volume":"42","author":"Gupta","year":"2015","journal-title":"Tex Heart Inst J"},{"key":"2019091012152298500_ytz057-B8","doi-asserted-by":"crossref","first-page":"183","DOI":"10.14503\/THIJ-14-4795","article-title":"No electromagnetic interference occurred in a patient with a HeartMate II left ventricular assist system and a subcutaneous implantable cardioverter-defibrillator","volume":"43","author":"Raman","year":"2016","journal-title":"Tex Heart Inst J"},{"key":"2019091012152298500_ytz057-B9","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1161\/CIRCEP.116.004633","article-title":"Subcutaneous implantable cardioverter-defibrillator shocks after left ventricular assist device implantation","volume":"9","author":"Pfeffer","year":"2016","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2019091012152298500_ytz057-B10","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.jacep.2015.10.008","article-title":"Subcutaneous implantable cardioverter-defibrillator and left ventricular assist device: a safe and effective approach for refractory heart failure","volume":"2","author":"Migliore","year":"2016","journal-title":"JACC Clin Electrophysiol"},{"key":"2019091012152298500_ytz057-B11","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1111\/jce.13433","article-title":"Troubleshooting electromagnetic interference in a patient with centrifugal flow left ventricular assist device and subcutaneous implantable cardioverter defibrillator","volume":"29","author":"Ahmed","year":"2018","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2019091012152298500_ytz057-B12","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1111\/pace.13273","article-title":"Subcutaneous implantable cardioverter defibrillator (S-ICD) shocks in a patient with a left ventricular assist device","volume":"41","author":"Saini","year":"2018","journal-title":"Pacing Clin Electrophysiol"},{"key":"2019091012152298500_ytz057-B13","first-page":"772","article-title":"Implantable cardioverter-defibrillator use in patients with left ventricular assist devices: a systematic review and meta-analysis","volume":"4","author":"Vakil","year":"2016","journal-title":"Journal Am Coll Cardiol HF"},{"key":"2019091012152298500_ytz057-B14","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1111\/jce.13831","article-title":"Mechanisms and management of inappropriate therapy in subcutaneous implantable cardioverter defibrillators","volume":"30","author":"Karnik","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2019091012152298500_ytz057-B15","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1111\/anec.12181","article-title":"Characteristics of the electrocardiogram in patients with continuous-flow left ventricular assist devices","volume":"20","author":"Martinez","year":"2015","journal-title":"Ann Noninvasive Electrocardiol"},{"key":"2019091012152298500_ytz057-B16","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.jelectrocard.2018.11.002","article-title":"Electrocardiographic changes after implantation of a left ventricular assist device\u2014potential implications for subcutaneous defibrillator therapy","volume":"52","author":"Zormpas","year":"2019","journal-title":"J Electrocardiol"}],"container-title":["European Heart Journal - Case Reports"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ehjcr\/advance-article-pdf\/doi\/10.1093\/ehjcr\/ytz057\/28539569\/ytz057.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/ehjcr\/article-pdf\/3\/2\/ytz057\/28888553\/ytz057.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,10]],"date-time":"2019-09-10T13:12:26Z","timestamp":1568121146000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ehjcr\/article\/doi\/10.1093\/ehjcr\/ytz057\/5481191"}},"subtitle":[],"editor":[{"given":"Nikos","family":"Papageorgiou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]},{"given":"Konstantinos","family":"Iliodromitis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]},{"given":"Domenico","family":"D\u2019Amario","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]},{"given":"Anastasia","family":"Vamvakidou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]},{"given":"Christian Fielder","family":"Camm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2019,4,28]]},"references-count":16,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2019,4,28]]},"published-print":{"date-parts":[[2019,6,1]]}},"URL":"https:\/\/doi.org\/10.1093\/ehjcr\/ytz057","relation":{},"ISSN":["2514-2119"],"issn-type":[{"value":"2514-2119","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2019,6]]},"published":{"date-parts":[[2019,4,28]]},"article-number":"ytz057"}}