{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:18:18Z","timestamp":1787008698609,"version":"build-2736575974"},"reference-count":9,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2019,12,17]],"date-time":"2019-12-17T00:00:00Z","timestamp":1576540800000},"content-version":"vor","delay-in-days":16,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100009780","name":"Region Sk\u00e5ne","doi-asserted-by":"crossref","award":["46780"],"award-info":[{"award-number":["46780"]}],"id":[{"id":"10.13039\/501100009780","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,12,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background\u2003<\/jats:title>\n                    <jats:p>Magnetic resonance imaging (MRI) is increasingly becoming the imaging modality of choice for many clinical disorders due to superior image quality and absence of radiation. However, access to MRI remains limited for most patients with cardiac implantable electronic devices due to potential safety concerns. In line with guidelines, there is no absolute contraindication to perform MRI, but warrants careful risk-benefit assessment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case summary\u2003<\/jats:title>\n                    <jats:p>A 59-year-old man was admitted with a 5-day history of central chest pain and few week\u2019s history of general malaise, dry cough, and breathlessness. Electrocardiogram confirmed complete atrioventricular block (CAVB). A slight increase in cardiac enzyme was noted. Coronary angiogram revealed atheromatous changes, but no obstructive coronary lesion. A temporary transvenous pacemaker was inserted. Transthoracic echocardiogram confirmed a dilated left ventricle with severely reduced left ventricular function. To facilitate diagnosis (hence prognosis), management and mobilization, investigation with cardiovascular magnetic resonance (CMR) was warranted but contraindicated by the temporary transvenous pacemaker. An active fixation pacemaker lead was therefore placed in the right ventricle via percutaneous puncture of the right subclavian vein and connected to a pulse generator, both secured to the skin with sutures and adhesive medical dressing. Appropriate device programming and close patient monitoring ensured that CMR could be performed without any adverse effects. A diagnosis of acute myocarditis was confirmed. Regular device interrogation during an extended 3-week period with temporary pacing ruled out any device failure. As there was no resolution of CAVB, the patient received a dual-chamber pacemaker.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion\u2003<\/jats:title>\n                    <jats:p>Cardiovascular magnetic resonance was feasible and safely performed on a patient with a temporary permanent external pacemaker system using a standard screw-in pacing lead and a regular pulse generator fixed to the skin. Although more studies are needed for generalizability, CMR may be used in highly selected patients with a temporary pacemaker.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ehjcr\/ytz228","type":"journal-article","created":{"date-parts":[[2019,12,17]],"date-time":"2019-12-17T09:07:31Z","timestamp":1576573651000},"page":"1-4","source":"Crossref","is-referenced-by-count":8,"title":["Cardiac magnetic resonance imaging in a patient with temporary external pacemaker: a case report"],"prefix":"10.1093","volume":"3","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5186-0252","authenticated-orcid":false,"given":"Uzma","family":"Chaudhry","sequence":"first","affiliation":[{"name":"Department of Cardiology, Clinical Sciences, Lund University, Arrhythmia Clinic, Sk\u00e5ne University Hospital, Getingev\u00e4gen, Lund S-221 85, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1945-9594","authenticated-orcid":false,"given":"Jonas","family":"Svensson","sequence":"first","affiliation":[{"name":"Medical Radiation Physics, Department of Translational Medicine, Lund University, J Waldenstr\u00f6ms gata 35, Malm\u00f6 S-205 02, Sweden"},{"name":"Department of Medical Imaging and Physiology, Sk\u00e5ne University Hospital, Getingev\u00e4gen, Lund S-221 85, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6237-9082","authenticated-orcid":false,"given":"Henrik","family":"Mos\u00e9n","sequence":"first","affiliation":[{"name":"Department of Clinical Physiology, Clinical Sciences, Lund University, Sk\u00e5ne University Hospital, Getingev\u00e4gen, Lund S-221 85, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2485-6044","authenticated-orcid":false,"given":"David","family":"M\u00f6rtsell","sequence":"first","affiliation":[{"name":"Department of Cardiology, Clinical Sciences, Lund University, Arrhythmia Clinic, Sk\u00e5ne University Hospital, Getingev\u00e4gen, Lund S-221 85, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2019,12,17]]},"reference":[{"key":"2020021802000595000_ytz228-B1","doi-asserted-by":"crossref","first-page":"e503","DOI":"10.1016\/j.hrthm.2017.09.001","article-title":"2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction","volume":"14","author":"Kusumoto","year":"2017","journal-title":"Heart Rhythm"},{"key":"2020021802000595000_ytz228-B2","doi-asserted-by":"crossref","first-page":"2878","DOI":"10.1161\/CIRCULATIONAHA.107.187256","article-title":"Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance","volume":"116","author":"Levine","year":"2007","journal-title":"Circulation"},{"key":"2020021802000595000_ytz228-B3","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1111\/j.1540-8159.2005.50024.x","article-title":"Current clinical issues for MRI scanning of pacemaker and defibrillator patients","volume":"28","author":"Kalin","year":"2005","journal-title":"Pacing Clin Electrophysiol"},{"key":"2020021802000595000_ytz228-B4","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1093\/europace\/eut206","article-title":"2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA)","volume":"15","author":"Brignole","year":"2013","journal-title":"Europace"},{"key":"2020021802000595000_ytz228-B5","first-page":"115","article-title":"MRI-conditional pacemakers: current perspectives","volume":"7","author":"Ferreira","year":"2014","journal-title":"Med Devices (Auckl)"},{"key":"2020021802000595000_ytz228-B6","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1161\/CIRCULATIONAHA.105.607655","article-title":"Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla","volume":"114","author":"Nazarian","year":"2006","journal-title":"Circulation"},{"key":"2020021802000595000_ytz228-B7","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1016\/j.hrcr.2016.01.012","article-title":"Emergent use of an MRI-conditional external pacemaker in a patient with sinus arrest facilitating diagnosis of a temporal lobe neoplasm","volume":"2","author":"McGuinn","year":"2016","journal-title":"HeartRhythm Case Rep"},{"key":"2020021802000595000_ytz228-B8","doi-asserted-by":"crossref","first-page":"2555","DOI":"10.1056\/NEJMoa1604267","article-title":"Safety of magnetic resonance imaging in patients with cardiac devices","volume":"377","author":"Nazarian","year":"2017","journal-title":"N Engl J Med"},{"key":"2020021802000595000_ytz228-B9","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1093\/europace\/eut045","article-title":"Utility and safety of temporary pacing using active fixation leads and externalized re-usable permanent pacemakers after lead extraction","volume":"15","author":"Kawata","year":"2013","journal-title":"Europace"}],"container-title":["European Heart Journal - Case Reports"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ehjcr\/article-pdf\/3\/4\/1\/32501510\/ytz228.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/ehjcr\/article-pdf\/3\/4\/1\/32501510\/ytz228.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,2,18]],"date-time":"2020-02-18T02:00:16Z","timestamp":1581991216000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ehjcr\/article\/3\/4\/1\/5679809"}},"subtitle":[],"editor":[{"given":"Jonathan M","family":"Behar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]},{"given":"Peter Henry","family":"Waddingham","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]},{"given":"Rafael","family":"Vidal-Perez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]},{"given":"Mohammed Majid","family":"Akhtar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]},{"given":"Vassilios Parisis","family":"Memtsas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2019,12,1]]},"references-count":9,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2019,12,17]]},"published-print":{"date-parts":[[2019,12,1]]}},"URL":"https:\/\/doi.org\/10.1093\/ehjcr\/ytz228","relation":{},"ISSN":["2514-2119"],"issn-type":[{"value":"2514-2119","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2019,12]]},"published":{"date-parts":[[2019,12,1]]}}}