{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T16:27:13Z","timestamp":1786724833888,"version":"build-2736575974"},"reference-count":10,"publisher":"Oxford University Press (OUP)","issue":"7","license":[{"start":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T00:00:00Z","timestamp":1782950400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,7,29]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aims<\/jats:title>\n                    <jats:p>Continuous positive airway pressure (CPAP) telemonitoring provides daily respiratory metrics, including Cheyne\u2013Stokes breathing percentage (CSB%), which may reflect ventilatory\u2013circulatory instability. However, inter-individual variability limits the clinical applicability of fixed thresholds. We developed a time-structured detection architecture using CPAP telemonitoring time-series data and evaluated its ability to identify temporal patterns preceding cardiovascular and cerebrovascular events.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and results<\/jats:title>\n                    <jats:p>In this retrospective observational study, 1265 patients with obstructive sleep apnoea undergoing CPAP telemonitoring were analysed. Daily CSB% values were smoothed using a 3-day moving average and evaluated relative to individualized dynamic baselines. The detection framework consisted of two complementary components: identification of sustained deviation from baseline and detection of abrupt pre-event surges. Central apnoea predominance, assessed using the central apnoea index, was incorporated as a hierarchical escalation layer. Among 25 adjudicated cardiovascular and cerebrovascular events in 20 patients (heart failure 11, atrial fibrillation 7, cerebrovascular accident 7), the architecture detected 23 events (92.0%) within the predefined D\u221228 window. Median lead time was 12.0 days (IQR 2.8\u201324.0). False-positive alerts were concentrated within a subset of individuals. Hierarchical filtering reduced alerts by 94.9% relative to the baseline signal layer while preserving event enrichment. Distinct temporal phenotypes, including trajectory-dominant and spike-dominant patterns, were observed across disease categories, consistent with disease-specific pre-event dynamics.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>CPAP-derived CSB% may function as a time-structured digital biomarker reflecting evolving ventilatory\u2013circulatory instability. A trajectory-based detection architecture may enable early identification of cardiovascular instability while maintaining operational feasibility in large-scale telemonitoring environments.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ehjdh\/ztag108","type":"journal-article","created":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T16:19:48Z","timestamp":1782922788000},"source":"Crossref","is-referenced-by-count":0,"title":["Time-structured detection of pre-event cardiovascular instability using CPAP-derived Cheyne\u2013Stokes breathing"],"prefix":"10.1093","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-8633-6768","authenticated-orcid":false,"given":"Kimimasa","family":"Saito","sequence":"first","affiliation":[{"name":"Saito Naika Kokyukika, Mie Sleep Clinic , 446 Sogo, Obata-cho, Ise-shi, Mie 519-0502 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoko","family":"Takamatsu","sequence":"additional","affiliation":[{"name":"Saito Naika Kokyukika, Mie Sleep Clinic , 446 Sogo, Obata-cho, Ise-shi, Mie 519-0502 ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,7,2]]},"reference":[{"key":"2026081410524009900_ztag108-B1","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1111\/resp.14192","article-title":"CPAP telemonitoring can track cheyne\u2013stokes respiration and detect serious cardiac events: the AlertApn\u00e9e study","volume":"27","author":"Prigent","year":"2022","journal-title":"Respirology"},{"key":"2026081410524009900_ztag108-B2","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1186\/s12931-025-03109-9","article-title":"Incident cheyne\u2013stokes respiration occurring in CPAP-treated patients and cardiovascular risk","volume":"26","author":"Prigent","year":"2025","journal-title":"Respir Res"},{"key":"2026081410524009900_ztag108-B3","doi-asserted-by":"crossref","first-page":"431","DOI":"10.5664\/jcsm.10346","article-title":"High nocturnal periodic breathing reported by PAP adherence data predicts decompensation of heart failure","volume":"19","author":"Ullah","year":"2023","journal-title":"J Clin Sleep Med"},{"key":"2026081410524009900_ztag108-B4","article-title":"Transition from chronic compensated to acute decompensated heart failure: insights from continuous haemodynamic monitoring","volume":"9","author":"Zile","year":"2016","journal-title":"Circ Heart Fail"},{"key":"2026081410524009900_ztag108-B5","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1164\/rccm.201103-0577OC","article-title":"Loop gain as a means to predict positive airway pressure suppression of cheyne\u2013stokes respiration in patients with heart failure","volume":"184","author":"Sands","year":"2011","journal-title":"Am J Respir Crit Care Med"},{"key":"2026081410524009900_ztag108-B6","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1111\/resp.12927","article-title":"Pathogenesis of central and complex sleep apnoea","volume":"22","author":"Orr","year":"2017","journal-title":"Respirology"},{"key":"2026081410524009900_ztag108-B7","doi-asserted-by":"crossref","DOI":"10.1093\/sleepadvances\/zpag042","article-title":"Cheyne\u2013stokes respiration detected via CPAP devices as a digital biomarker for heart failure in obstructive sleep apnoea: a systematic review","volume":"7","author":"Mutombe","year":"2026","journal-title":"Sleep Adv"},{"key":"2026081410524009900_ztag108-B8","doi-asserted-by":"crossref","first-page":"790331","DOI":"10.3389\/fcvm.2022.790331","article-title":"Cheyne\u2013stokes breathing as a predictive indicator of heart failure in patients with obstructive sleep apnea: a retrospective study using CPAP remote monitoring data","volume":"9","author":"Saito","year":"2022","journal-title":"Front Cardiovasc Med"},{"key":"2026081410524009900_ztag108-B9","doi-asserted-by":"crossref","first-page":"1181","DOI":"10.1007\/s11325-021-02510-0","article-title":"Periodic breathing in patients with stable obstructive sleep apnea on long-term continuous positive airway pressure treatment: a retrospective study using CPAP remote monitoring data","volume":"26","author":"Saito","year":"2022","journal-title":"Sleep Breath"},{"key":"2026081410524009900_ztag108-B10","first-page":"115","article-title":"Atrial remodeling and atrial fibrillation: mechanisms and implications","volume":"102","author":"Nattel","year":"2008","journal-title":"Circ Res"}],"container-title":["European Heart Journal - Digital Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ehjdh\/advance-article-pdf\/doi\/10.1093\/ehjdh\/ztag108\/68684650\/ztag108.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ehjdh\/article-pdf\/7\/7\/ztag108\/68684650\/ztag108.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ehjdh\/article-pdf\/7\/7\/ztag108\/68684650\/ztag108.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T15:28:47Z","timestamp":1786721327000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ehjdh\/article\/doi\/10.1093\/ehjdh\/ztag108\/8723832"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,2]]},"references-count":10,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2026,7,29]]}},"URL":"https:\/\/doi.org\/10.1093\/ehjdh\/ztag108","relation":{},"ISSN":["2634-3916"],"issn-type":[{"value":"2634-3916","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,8]]},"published":{"date-parts":[[2026,7,2]]},"article-number":"ztag108"}}