{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T06:12:21Z","timestamp":1788502341756,"version":"build-2803163510"},"reference-count":48,"publisher":"Oxford University Press (OUP)","issue":"7","license":[{"start":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T00:00:00Z","timestamp":1786579200000},"content-version":"vor","delay-in-days":15,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000274","name":"British Heart Foundation","doi-asserted-by":"publisher","award":["PG\/17\/50\/32903"],"award-info":[{"award-number":["PG\/17\/50\/32903"]}],"id":[{"id":"10.13039\/501100000274","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","award":["EP\/T517963\/1"],"award-info":[{"award-number":["EP\/T517963\/1"]}],"id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,7,29]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aims<\/jats:title>\n                    <jats:p>Hypertension is a major risk factor for cardiovascular diseases. This study proposes a novel hypertension community-based screening framework based on intra-subject awake\u2013sleep differences in photoplethysmography (PPG) indices, using machine learning. We hypothesized that normotensive individuals exhibit greater PPG variation between awake and sleep states than unmanaged hypertensive individuals.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and results<\/jats:title>\n                    <jats:p>The Aurora-BP dataset (n = 180; 138 normotensive, 42 hypertensive) was used for model development, with 18 subjects reserved for internal testing. External validation was performed using the independent CUHK-BP dataset (n = 26; 11 normotensive, 15 hypertensive). Twenty PPG-based indices were extracted, and subject-level P-values from Mann\u2013Whitney U-tests comparing awake and sleep periods were used as model features. Discretized P-values served as inputs for four machine learning models. The support vector machine (SVM) achieved the highest performance, with 81.1 \u00b1 8.4% accuracy and 82.8 \u00b1 8.1% F1-score on the internal test set using all indices. On the external test set, the SVM using only temporal indices achieved 84.6% accuracy and 86.7% F1 score. Temporal indices, especially those linked to the dicrotic notch, showed strong generalizability across datasets.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The study demonstrates the feasibility of awake\u2013sleep PPG analysis for hypertension screening, highlighting the potential of wearable PPG devices for ambulatory monitoring.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ehjdh\/ztag131","type":"journal-article","created":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T11:45:34Z","timestamp":1786535134000},"source":"Crossref","is-referenced-by-count":0,"title":["Hypertension screening via awake\u2013sleep differences in photoplethysmogram signals"],"prefix":"10.1093","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0761-4323","authenticated-orcid":false,"given":"Jingyuan","family":"Hong","sequence":"first","affiliation":[{"name":"School of Imaging Sciences and Biomedical Engineering, King's College London, St Thomas' Hospital , London SE1 7EH ,","place":["UK"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manasi","family":"Nandi","sequence":"additional","affiliation":[{"name":"School of Cancer and Pharmaceutical Science, King\u2019s College London , London ,","place":["UK"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yali","family":"Zheng","sequence":"additional","affiliation":[{"name":"College of Health Science and Environmental Engineering, Shenzhen Technology University , Shenzhen ,","place":["China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3742-5259","authenticated-orcid":false,"given":"Jordi","family":"Alastruey","sequence":"additional","affiliation":[{"name":"School of Imaging Sciences and Biomedical Engineering, King's College London, St Thomas' Hospital , London SE1 7EH ,","place":["UK"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,8,13]]},"reference":[{"key":"2026090401261109000_ztag131-B1","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1038\/s41581-019-0244-2","article-title":"The global epidemiology of hypertension","volume":"16","author":"Mills","year":"2020","journal-title":"Nat Rev Nephrol"},{"key":"2026090401261109000_ztag131-B2","doi-asserted-by":"crossref","first-page":"3912","DOI":"10.1093\/eurheartj\/ehae178","article-title":"2024 ESC guidelines for the management of elevated blood pressure and hypertension: developed by the task force on the management of elevated blood pressure and hypertension of the European Society of Cardiology (ESC) and endorsed by the European Society of Endocrinology (ESE) and the European Stroke Organisation (ESO)","volume":"45","author":"McEvoy","year":"2024","journal-title":"Eur Heart J"},{"key":"2026090401261109000_ztag131-B3","author":"NICE guideline"},{"key":"2026090401261109000_ztag131-B4","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2023.1103216","article-title":"Home blood pressure measurement for hypertension management in the real world: do not just measure, but share with your physician","volume":"10","author":"Rhee","year":"2023","journal-title":"Front Cardiovasc Med"},{"key":"2026090401261109000_ztag131-B5","doi-asserted-by":"crossref","first-page":"6149","DOI":"10.1038\/s41598-023-33205-z","article-title":"Method-comparison study between a watch-like sensor and a cuff-based device for 24-h ambulatory blood pressure monitoring","volume":"13","author":"Proen\u00e7a","year":"2023","journal-title":"Sci Rep"},{"key":"2026090401261109000_ztag131-B6","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pmed.1002389","article-title":"Self-monitoring of blood pressure in hypertension: a systematic review and individual patient data meta-analysis","volume":"14","author":"Tucker","year":"2017","journal-title":"PLoS Med"},{"key":"2026090401261109000_ztag131-B7","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1109\/JPROC.2022.3149785","article-title":"Wearable photoplethysmography for cardiovascular monitoring","volume":"110","author":"Charlton","year":"2022","journal-title":"Proc IEEE Inst Electr Electron Eng"},{"key":"2026090401261109000_ztag131-B8","doi-asserted-by":"crossref","first-page":"1600","DOI":"10.1136\/heartjnl-2021-320417","article-title":"Smartphone detection of atrial fibrillation using photoplethysmography: a systematic review and meta-analysis","volume":"108","author":"Gill","year":"2022","journal-title":"Heart"},{"key":"2026090401261109000_ztag131-B9","doi-asserted-by":"crossref","first-page":"300002","DOI":"10.20517\/chatmed.2023.23","article-title":"Validation of deep learning models for cuffless blood pressure estimation on a large benchmarking dataset","volume":"3","author":"Huang","year":"2024","journal-title":"Connect Health Telemed"},{"key":"2026090401261109000_ztag131-B10","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1038\/s41598-022-27170-2","article-title":"Features from the photoplethysmogram and the electrocardiogram for estimating changes in blood pressure","volume":"13","author":"Finnegan","year":"2023","journal-title":"Sci Rep"},{"key":"2026090401261109000_ztag131-B11","doi-asserted-by":"crossref","DOI":"10.1016\/j.bspc.2020.102242","article-title":"Remote estimation of pulse wave features related to arterial stiffness and blood pressure using a camera","volume":"64","author":"Djeldjli","year":"2021","journal-title":"Biomed Signal Process Control"},{"key":"2026090401261109000_ztag131-B12","doi-asserted-by":"crossref","first-page":"111001","DOI":"10.1088\/1361-6579\/acead2","article-title":"The 2023 wearable photoplethysmography roadmap","volume":"44","author":"Charlton","year":"2023","journal-title":"Physiol Meas"},{"key":"2026090401261109000_ztag131-B13","doi-asserted-by":"crossref","DOI":"10.1016\/j.bea.2024.100123","article-title":"Investigating the impact of contact pressure on photoplethysmograms","volume":"7","author":"Sirki\u00e4","year":"2024","journal-title":"Biomed Eng Adv"},{"key":"2026090401261109000_ztag131-B14","doi-asserted-by":"crossref","first-page":"126","DOI":"10.3390\/bios11040126","article-title":"Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring","volume":"11","author":"Fine","year":"2021","journal-title":"Biosensors (Basel)"},{"key":"2026090401261109000_ztag131-B15","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1038\/s41746-019-0136-7","article-title":"The use of photoplethysmography for assessing hypertension","volume":"2","author":"Elgendi","year":"2019","journal-title":"NPJ Digit Med"},{"key":"2026090401261109000_ztag131-B16","doi-asserted-by":"crossref","first-page":"2219","DOI":"10.1109\/JBHI.2022.3181328","article-title":"KD-informer: a cuff-less continuous blood pressure waveform estimation approach based on single photoplethysmography","volume":"27","author":"Ma","year":"2023","journal-title":"IEEE J Biomed Health Inform"},{"key":"2026090401261109000_ztag131-B17","doi-asserted-by":"crossref","first-page":"3918","DOI":"10.1109\/JBHI.2023.3324319","article-title":"PPG-based continuous BP waveform estimation using polarized attention-guided conditional adversarial learning model","volume":"29","author":"Ma","year":"2025","journal-title":"IEEE J Biomed Health Inform"},{"key":"2026090401261109000_ztag131-B18","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.1161\/HYPERTENSIONAHA.114.03882","article-title":"Ambulatory blood pressure monitoring is ready to replace clinic blood pressure in the diagnosis of hypertension","volume":"64","author":"Head","year":"2014","journal-title":"Hypertension"},{"key":"2026090401261109000_ztag131-B19","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1152\/japplphysiol.00661.2009","article-title":"Pressed for time: the circadian clock and hypertension","volume":"107","author":"Rudic","year":"2009","journal-title":"J Appl Physiol (Bethesda Md 1985)"},{"key":"2026090401261109000_ztag131-B20","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1038\/hr.2012.26","article-title":"Nocturnal blood pressure and cardiovascular disease: a review of recent advances","volume":"35","author":"Yano","year":"2012","journal-title":"Hypertens Res"},{"key":"2026090401261109000_ztag131-B21","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1007\/s10916-016-0558-6","article-title":"Pulse arrival time based cuff-less and 24-h wearable blood pressure monitoring and its diagnostic value in hypertension","volume":"40","author":"Zheng","year":"2016","journal-title":"J Med Syst"},{"key":"2026090401261109000_ztag131-B22","doi-asserted-by":"crossref","DOI":"10.1016\/j.compbiomed.2021.104861","article-title":"Characterization of the vascular system using overnight wearable-based pulse arrival time and ambulatory blood pressure: a pilot study","volume":"137","author":"Hong","year":"2021","journal-title":"Comput Biol Med"},{"key":"2026090401261109000_ztag131-B23","doi-asserted-by":"crossref","first-page":"65","DOI":"10.3390\/diagnostics8030065","article-title":"Hypertension assessment via ECG and PPG signals: an evaluation using MIMIC database","volume":"8","author":"Liang","year":"2018","journal-title":"Diagnostics"},{"key":"2026090401261109000_ztag131-B24","author":"Ghosh"},{"key":"2026090401261109000_ztag131-B25","article-title":"Causal inference for hypertension prediction with wearable electrocardiogram and photoplethysmogram signals: feasibility study","volume":"9","author":"Gong","year":"2025","journal-title":"JMIR Cardio"},{"key":"2026090401261109000_ztag131-B26","doi-asserted-by":"crossref","first-page":"H1290","DOI":"10.1152\/ajpheart.00454.2023","article-title":"Non-invasive haemodynamic indices of vascular ageing: an in silico assessment","volume":"325","author":"Hong","year":"2023","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"2026090401261109000_ztag131-B27","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1097\/HJH.0000000000002620","article-title":"Nocturnal hypertension: a common phenotype in a tertiary clinical setting associated with increased arterial stiffness and central blood pressure","volume":"39","author":"Nolde","year":"2021","journal-title":"J Hypertens"},{"key":"2026090401261109000_ztag131-B28","doi-asserted-by":"crossref","first-page":"2864","DOI":"10.1109\/JBHI.2022.3153259","article-title":"A comparison of wearable tonometry, photoplethysmography, and electrocardiography for cuffless measurement of blood pressure in an ambulatory setting","volume":"26","author":"Mieloszyk","year":"2022","journal-title":"IEEE J Biomed Health Inform"},{"key":"2026090401261109000_ztag131-B29","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.119.015062","article-title":"Association of sleep characteristics with nocturnal hypertension and nondipping blood pressure in the CARDIA study","volume":"9","author":"Thomas","year":"2020","journal-title":"J Am Heart Assoc"},{"key":"2026090401261109000_ztag131-B30","first-page":"e13","article-title":"2017 ACC\/AHA\/AAPA\/ABC\/ACPM\/AGS\/APhA\/ASH\/ASPC\/NMA\/PCNA guideline for the prevention, detection, evaluation, and management of high blood pressure in adults: a report of the American College of Cardiology\/American Heart Association task force on clinical practice guidelines","volume":"71","author":"Whelton","year":"2018","journal-title":"Hypertension"},{"key":"2026090401261109000_ztag131-B31","first-page":"64","article-title":"Update on the Hong Kong reference framework for hypertension care for adults in primary care settings\u2014review of evidence on the definition of high blood pressure and goal of therapy","volume":"25","author":"Lim","year":"2019","journal-title":"Hong Kong Med J"},{"key":"2026090401261109000_ztag131-B32","doi-asserted-by":"crossref","first-page":"054001","DOI":"10.1088\/1361-6579\/aabe6a","article-title":"Assessing mental stress from the photoplethysmogram: a numerical study","volume":"39","author":"Charlton","year":"2018","journal-title":"Physiol Meas"},{"key":"2026090401261109000_ztag131-B33","first-page":"424","article-title":"Mean blood pressure assessment during post-exercise: result from two different methods of calculation","volume":"15","author":"Sainas","year":"2016","journal-title":"J Sports Sci Med"},{"key":"2026090401261109000_ztag131-B34","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1161\/HYPERTENSIONAHA.108.124008","article-title":"Prevalence and factors associated with circadian blood pressure patterns in hypertensive patients","volume":"53","author":"de la Sierra","year":"2009","journal-title":"Hypertension"},{"key":"2026090401261109000_ztag131-B35","doi-asserted-by":"crossref","first-page":"8380","DOI":"10.3390\/app12168380","article-title":"Hypertension detection based on photoplethysmography signal morphology and machine learning techniques","volume":"12","author":"Evdochim","year":"2022","journal-title":"Appl Sci"},{"key":"2026090401261109000_ztag131-B36","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1093\/ehjdh\/ztac066","article-title":"Prediction of white-coat hypertension and white-coat uncontrolled hypertension using machine learning algorithm","volume":"3","author":"Shih","year":"2022","journal-title":"Eur Heart J Digit Health"},{"key":"2026090401261109000_ztag131-B37","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1613\/jair.953","article-title":"SMOTE: synthetic minority over-sampling technique","volume":"16","author":"Chawla","year":"2002","journal-title":"J Artif Intell Res"},{"key":"2026090401261109000_ztag131-B38","author":"Lundberg"},{"key":"2026090401261109000_ztag131-B39","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1161\/HYPERTENSIONAHA.111.189100","article-title":"Does blood pressure inevitably rise with age?","volume":"60","author":"Gurven","year":"2012","journal-title":"Hypertension"},{"key":"2026090401261109000_ztag131-B40","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1007\/s10916-018-0942-5","article-title":"Toward hypertension prediction based on PPG-derived HRV signals: a feasibility study","volume":"42","author":"Lan","year":"2018","journal-title":"J Med Syst"},{"key":"2026090401261109000_ztag131-B41","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1161\/CIRCRESAHA.121.318061","article-title":"Arterial stiffness and cardiovascular risk in hypertension","volume":"128","author":"Boutouyrie","year":"2021","journal-title":"Circ Res"},{"key":"2026090401261109000_ztag131-B42","doi-asserted-by":"crossref","first-page":"105479","DOI":"10.1016\/j.compbiomed.2022.105479","article-title":"A machine learning approach for hypertension detection based on photoplethysmography and clinical data","volume":"145","author":"Martinez-R\u00edos","year":"2022","journal-title":"Comput Biol Med"},{"key":"2026090401261109000_ztag131-B43","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/B978-0-44-462613-4.00008-8","volume-title":"Volatile Biomarkers","author":"Aksenov","year":"2013"},{"key":"2026090401261109000_ztag131-B44","doi-asserted-by":"crossref","first-page":"53","DOI":"10.4258\/hir.2017.23.1.53","article-title":"New aging index using signal features of both photoplethysmograms and acceleration plethysmograms","volume":"23","author":"Ahn","year":"2017","journal-title":"Healthc Inform Res"},{"key":"2026090401261109000_ztag131-B45","author":"Finnegan"},{"key":"2026090401261109000_ztag131-B46","doi-asserted-by":"crossref","first-page":"S48","DOI":"10.1038\/sj.npp.1300146","article-title":"Dynamics of heart rate and sleep stages in normals and patients with sleep apnea","volume":"28","author":"Penzel","year":"2003","journal-title":"Neuropsychopharmacology"},{"key":"2026090401261109000_ztag131-B47","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1152\/japplphysiol.00516.2010","article-title":"Effects of sleep on the cardiovascular and thermoregulatory systems: a possible role for hypocretins","volume":"109","author":"Schwimmer","year":"2010","journal-title":"J Appl Physiol"},{"key":"2026090401261109000_ztag131-B48","doi-asserted-by":"crossref","first-page":"3596","DOI":"10.1093\/eurheartj\/ehy486","article-title":"Elevated blood pressure and risk of aortic valve disease: a cohort analysis of 5.4 million UK adults","volume":"39","author":"Rahimi","year":"2018","journal-title":"Eur Heart J"}],"container-title":["European Heart Journal - Digital Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ehjdh\/advance-article-pdf\/doi\/10.1093\/ehjdh\/ztag131\/70632626\/ztag131.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ehjdh\/article-pdf\/7\/7\/ztag131\/70632626\/ztag131.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ehjdh\/article-pdf\/7\/7\/ztag131\/70632626\/ztag131.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T05:26:24Z","timestamp":1788499584000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ehjdh\/article\/doi\/10.1093\/ehjdh\/ztag131\/8760871"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,29]]},"references-count":48,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2026,7,29]]}},"URL":"https:\/\/doi.org\/10.1093\/ehjdh\/ztag131","relation":{},"ISSN":["2634-3916"],"issn-type":[{"value":"2634-3916","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,8]]},"published":{"date-parts":[[2026,7,29]]},"article-number":"ztag131"}}