{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T09:07:59Z","timestamp":1788858479390,"version":"build-2803163510"},"reference-count":20,"publisher":"Oxford University Press (OUP)","issue":"8","license":[{"start":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T00:00:00Z","timestamp":1787270400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Institute of Cardiology in Warsaw, Poland","award":["4.57\/VI\/24"],"award-info":[{"award-number":["4.57\/VI\/24"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,9,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aims<\/jats:title>\n                    <jats:p>To develop an artificial intelligence (AI)-driven approach that analyses continuous-wave (CW) Doppler spectra from the aortic valve (AV) to detect reduced (\u226440%) left ventricular ejection fraction (LVEF) without requiring dedicated two-dimensional left ventricular imaging or ECG-gated volumetric analysis for model inference. Current AI solutions for LVEF assessment rely on 2D imaging and ECG signals, limiting utility when data quality is poor.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and results<\/jats:title>\n                    <jats:p>This retrospective study analysed 4231 aortic CW Doppler recordings from 3988 examinations (3580 patients). Preprocessing yielded 13 359 single-peak images. A CoAtNet-2 neural network was developed using patient-level training and validation cohorts and evaluated on an independent held-out test cohort. The network generated predictions for each single-peak image, and these probabilities were then averaged per examination. Maximum AV blood flow velocity and average CW Doppler pixel intensity were measured. LVEF \u226440% occurred in 20.8% of examinations, associating with lower maximum AV velocity and higher average pixel intensity. In the independent test cohort (782 examinations), the model achieved 85.2% accuracy, 79.0% sensitivity, 86.7% specificity, an AUC of 0.906, an NPV of 94.3%, and a PPV of 59.9%, with robust performance across subgroups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This proof-of-concept study demonstrates the feasibility of using AI to analyse CW Doppler spectra for rapid, non-invasive identification of reduced LVEF without requiring dedicated two-dimensional left ventricular imaging or ECG-gated volumetric analysis for model inference. By leveraging underutilized echocardiographic Doppler data, this signal-based approach may serve as an adjunctive screening or rule-out tool, particularly when standard imaging or ECG-gated analysis is limited or delayed.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ehjdh\/ztag137","type":"journal-article","created":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T11:50:50Z","timestamp":1787226650000},"source":"Crossref","is-referenced-by-count":0,"title":["Artificial intelligence analysis of continuous wave Doppler spectra to detect reduced left ventricular ejection fraction"],"prefix":"10.1093","volume":"7","author":[{"given":"Edyta","family":"Kaczmarska-Dyrda","sequence":"first","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-3438-0692","authenticated-orcid":false,"given":"Karol A","family":"Sadowski","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9359-4527","authenticated-orcid":false,"given":"Damian","family":"Wal\u0105g","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Malwina","family":"Gonet","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piotr","family":"Trochimiuk","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piotr","family":"Stankiewicz","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karolina","family":"Kryczka","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacek","family":"Kwieci\u0144ski","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piotr","family":"Rudzi\u0144ski","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacek","family":"K\u0105dziela","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-9050-2273","authenticated-orcid":false,"given":"Micha\u0142","family":"Kania","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gary S","family":"Mintz","sequence":"additional","affiliation":[{"name":"Cardiovascular Research Foundation , New York ,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8278-136X","authenticated-orcid":false,"given":"Zofia","family":"Dzieli\u0144ska","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcin","family":"Demkow","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hubert","family":"\u0141azarczyk","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1657-8096","authenticated-orcid":false,"given":"\u0141ukasz","family":"Kali\u0144czuk","sequence":"additional","affiliation":[{"name":"National Institute of Cardiology , Alpejska 42, 04\u2013628, Warsaw ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,8,21]]},"reference":[{"key":"2026090804164818700_ztag137-B1","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1093\/eurheartj\/ehaa587","article-title":"Assessing left ventricular systolic function: from ejection fraction to strain analysis","volume":"42","author":"Halliday","year":"2021","journal-title":"Eur Heart J"},{"key":"2026090804164818700_ztag137-B2","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.1002\/ejhf.2576","article-title":"Left ventricular ejection fraction as the primary heart failure phenotyping parameter","volume":"24","author":"Lund","year":"2022","journal-title":"Eur J Heart Fail"},{"key":"2026090804164818700_ztag137-B3","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1016\/j.echo.2011.05.004","article-title":"Clinical validation of a novel speckle-tracking-based ejection fraction assessment method","volume":"24","author":"Szulik","year":"2011","journal-title":"J Am Soc Echocardiogr"},{"key":"2026090804164818700_ztag137-B4"},{"key":"2026090804164818700_ztag137-B5","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1016\/j.echo.2023.10.012","article-title":"The pixel variation score: an echocardiographic index to assess temporal variation of mitral regurgitant flow","volume":"37","author":"Verbeke","year":"2024","journal-title":"J Am Soc Echocardiogr"},{"key":"2026090804164818700_ztag137-B6","doi-asserted-by":"crossref","first-page":"904","DOI":"10.1136\/heartjnl-2019-316157","article-title":"Average pixel intensity method for prediction of outcome in secondary mitral regurgitation","volume":"106","author":"Kamoen","year":"2020","journal-title":"Heart"},{"key":"2026090804164818700_ztag137-B7","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1093\/ejechocard\/jen174","article-title":"European association of echocardiography recommendations for standardization of performance, digital storage and reporting of echocardiographic studies","volume":"9","author":"Evangelista","year":"2008","journal-title":"Eur J Echocardiogr"},{"key":"2026090804164818700_ztag137-B8","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1038\/nmeth.2089","article-title":"NIH image to ImageJ: 25 years of image analysis","volume":"9","author":"Schneider","year":"2012","journal-title":"Nat Methods"},{"key":"2026090804164818700_ztag137-B9","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCIMAGING.119.009303","article-title":"Automated echocardiographic quantification of left ventricular ejection fraction without volume measurements using a machine learning algorithm mimicking a human expert","volume":"12","author":"Asch","year":"2019","journal-title":"Circ Cardiovasc Imaging"},{"key":"2026090804164818700_ztag137-B10","doi-asserted-by":"crossref","first-page":"e012293","DOI":"10.1161\/CIRCIMAGING.120.012293","article-title":"Deep learning-based automated echocardiographic quantification of left ventricular ejection fraction: a point-of-care solution","volume":"14","author":"Asch","year":"2021","journal-title":"Circ Cardiovasc Imaging"},{"key":"2026090804164818700_ztag137-B11","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1053\/j.jvca.2024.01.005","article-title":"Pragmatic evaluation of a deep-learning algorithm to automate ejection fraction on hand-held, point-of-care echocardiography in a cardiac surgical operating room","volume":"38","author":"MacKay","year":"2024","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"2026090804164818700_ztag137-B12","doi-asserted-by":"crossref","first-page":"e007988","DOI":"10.1161\/CIRCEP.119.007988","article-title":"Assessing and mitigating bias in medical artificial intelligence: the effects of race and ethnicity on a deep learning model for ECG analysis","volume":"13","author":"Noseworthy","year":"2020","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026090804164818700_ztag137-B13","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/0002-8703(87)90016-0","article-title":"Relationship between age, body size, gender, and blood pressure and Doppler flow measurements in the aorta and pulmonary artery","volume":"113","author":"Gardin","year":"1987","journal-title":"Am Heart J"},{"key":"2026090804164818700_ztag137-B14","doi-asserted-by":"crossref","first-page":"51","DOI":"10.4244\/EIJ-D-20-00648","article-title":"Deep learning for prediction of fractional flow reserve from resting coronary pressure curves","volume":"17","author":"Zimmermann","year":"2021","journal-title":"EuroIntervention"},{"key":"2026090804164818700_ztag137-B15","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1161\/01.CIR.74.2.323","article-title":"Noninvasive evaluation of left ventricular performance based on peak aortic blood acceleration measured with a continuous-wave Doppler velocity meter","volume":"74","author":"Sabbah","year":"1986","journal-title":"Circulation"},{"key":"2026090804164818700_ztag137-B16","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.1378\/chest.103.4.1064","article-title":"Doppler-derived aortic maximal acceleration. A reliable index of left ventricular systolic function","volume":"103","author":"DuBourg","year":"1993","journal-title":"Chest"},{"key":"2026090804164818700_ztag137-B17","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1097\/RTI.0000000000000525","article-title":"Myocardial cut-off sign is a sensitive and specific cardiac computed tomography and magnetic resonance imaging sign to distinguish left ventricular pseudoaneurysms from true aneurysms","volume":"37","author":"Ballard","year":"2022","journal-title":"J Thorac Imaging"},{"key":"2026090804164818700_ztag137-B18","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/j.jcmg.2023.09.011","article-title":"Echocardiography-based deep learning model to differentiate constrictive pericarditis and restrictive cardiomyopathy","volume":"17","author":"Chao","year":"2024","journal-title":"JACC Cardiovasc Imaging"},{"key":"2026090804164818700_ztag137-B19","doi-asserted-by":"crossref","first-page":"1918","DOI":"10.1016\/j.jcmg.2021.04.018","article-title":"Artificial intelligence for automatic measurement of left ventricular strain in echocardiography","volume":"14","author":"Salte","year":"2021","journal-title":"JACC Cardiovasc Imaging"},{"key":"2026090804164818700_ztag137-B20","doi-asserted-by":"crossref","first-page":"2158","DOI":"10.1111\/echo.14541","article-title":"Quantitative analysis of spectral Doppler clicks in assessment of aortic stenosis","volume":"36","author":"White","year":"2019","journal-title":"Echocardiography"}],"container-title":["European Heart Journal - Digital Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ehjdh\/advance-article-pdf\/doi\/10.1093\/ehjdh\/ztag137\/70750030\/ztag137.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ehjdh\/article-pdf\/7\/8\/ztag137\/70750030\/ztag137.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ehjdh\/article-pdf\/7\/8\/ztag137\/70750030\/ztag137.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T08:16:53Z","timestamp":1788855413000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ehjdh\/article\/doi\/10.1093\/ehjdh\/ztag137\/8767673"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,21]]},"references-count":20,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,9,4]]}},"URL":"https:\/\/doi.org\/10.1093\/ehjdh\/ztag137","relation":{},"ISSN":["2634-3916"],"issn-type":[{"value":"2634-3916","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,10]]},"published":{"date-parts":[[2026,8,21]]},"article-number":"ztag137"}}