{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T15:33:04Z","timestamp":1779377584581,"version":"3.53.1"},"reference-count":17,"publisher":"Oxford University Press (OUP)","issue":"7","license":[{"start":{"date-parts":[[2021,10,2]],"date-time":"2021-10-02T00:00:00Z","timestamp":1633132800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"funder":[{"DOI":"10.13039\/100015250","name":"National Institute for Health Research Bristol Biomedical Research Centre","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100015250","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000046","name":"Abbott","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000046","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,10,26]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Aim<\/jats:title>\n                  <jats:p>Implantable loop recorders (ILRs) are now routinely implanted for long-term cardiac monitoring in the clinical setting. The aim of this study was to examine the real-world performance of these devices focusing on the management changes made in response to ILR-recorded data.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods and results<\/jats:title>\n                  <jats:p>This was a single-centre, prospective observational study of consecutive patients undergoing ILR implantation. All patients who underwent implantation of a Medtronic Reveal LINQ device from September 2017 to June 2019 at Barts Heart Centre were included. Five hundred and one patients were included. Three hundred and two (60%) patients underwent ILR implantation for an indication of pre-syncope\/syncope, 96 (19%) for palpitations, 72 (14%) for atrial fibrillation (AF) detection with a history of cryptogenic stroke, and 31 (6%) for high risk of serious cardiac arrhythmia. The primary outcome of this study was that an ILR-derived diagnosis altered management in 110 patients (22%). Secondary outcomes concerned subgroup analyses by indication: in patients who presented with syncope\/pre-syncope, a change in management resulting from ILR data was positively associated with age [hazard ratio (HR) 1.04, 95% confidence interval 1.02\u20131.06; P\u00a0&amp;lt;\u00a00.001] and negatively associated with a normal electrocardiogram at baseline (HR 0.54 [0.31\u20130.93]; P\u00a0=\u00a00.03). Few patients (1\/57, 2%) aged &amp;lt;40\u00a0years in this group underwent device implantation, compared to 19\/62 patients (31%) aged 75 years and over (P\u00a0=\u00a00.0024). Out of 183 (12%) patients, 22 in the 40\u201374 age range had a device implanted. Among patients who underwent ILR insertion following cryptogenic stroke, 13\/72 (18%) had AF detected, leading to a decision to commence anticoagulation.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>These results inform the utility of ILR in the clinical setting. Diagnoses provided by ILR that lead to changes in management are rare in patients under age 40, particularly following syncope, pre-syncope, or palpitations. In older patients, new diagnoses are frequently made and trigger important changes in treatment.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/ehjqcco\/qcab071","type":"journal-article","created":{"date-parts":[[2021,9,30]],"date-time":"2021-09-30T19:27:51Z","timestamp":1633030071000},"page":"770-777","source":"Crossref","is-referenced-by-count":11,"title":["The utility of implantable loop recorders in patient management: an age- and indication-stratified study in the outpatient-implant era"],"prefix":"10.1093","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1914-4149","authenticated-orcid":false,"given":"Mihir M","family":"Sanghvi","sequence":"first","affiliation":[{"name":"Barts Heart Centre, St Bartholomew's Hospital , West Smithfield, London EC1A 7BE, UK"},{"name":"William Harvey Heart Centre, Queen Mary University of London, Charterhouse Square , London EC1A 6BQ, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel M","family":"Jones","sequence":"additional","affiliation":[{"name":"Barts Heart Centre, St Bartholomew's Hospital , West Smithfield, London EC1A 7BE, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeremy","family":"Kalindjian","sequence":"additional","affiliation":[{"name":"Barts Heart Centre, St Bartholomew's Hospital , West Smithfield, London EC1A 7BE, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4583-5453","authenticated-orcid":false,"given":"Christopher","family":"Monkhouse","sequence":"additional","affiliation":[{"name":"Barts Heart Centre, St Bartholomew's Hospital , West Smithfield, London EC1A 7BE, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rui","family":"Providencia","sequence":"additional","affiliation":[{"name":"Barts Heart Centre, St Bartholomew's Hospital , West Smithfield, London EC1A 7BE, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard J","family":"Schilling","sequence":"additional","affiliation":[{"name":"Barts Heart Centre, St Bartholomew's Hospital , West Smithfield, London EC1A 7BE, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikhil","family":"Ahluwalia","sequence":"additional","affiliation":[{"name":"Barts Heart Centre, St Bartholomew's Hospital , West Smithfield, London EC1A 7BE, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark J","family":"Earley","sequence":"additional","affiliation":[{"name":"Barts Heart Centre, St Bartholomew's Hospital , West Smithfield, London EC1A 7BE, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Malcolm","family":"Finlay","sequence":"additional","affiliation":[{"name":"Barts Heart Centre, St Bartholomew's Hospital , West Smithfield, London EC1A 7BE, UK"},{"name":"William Harvey Heart Centre, Queen Mary University of London, Charterhouse Square , London EC1A 6BQ, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2021,10,2]]},"reference":[{"key":"2022102617170764100_bib1","doi-asserted-by":"crossref","first-page":"1883","DOI":"10.1093\/eurheartj\/ehy037","article-title":"2018 ESC guidelines for the diagnosis and management of syncope","volume":"39","author":"Brignole","year":"2018","journal-title":"Eur Heart J"},{"key":"2022102617170764100_bib2","first-page":"e60","article-title":"2017 ACC\/AHA\/HRS Guideline for the Evaluation and Management of Patients With Syncope: A report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society","volume":"136","author":"Shen","year":"2017","journal-title":"Circulation"},{"key":"2022102617170764100_bib3","doi-asserted-by":"crossref","first-page":"2410","DOI":"10.1016\/j.jacc.2019.09.012","article-title":"ACC\/AHA\/HRS versus ESC guidelines for the diagnosis and management of syncope: JACC guideline comparison","volume":"74","author":"Goldberger","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"2022102617170764100_bib4","doi-asserted-by":"crossref","first-page":"2900","DOI":"10.1111\/jce.14206","article-title":"A nurse-led implantable loop recorder service is safe and cost effective","volume":"30","author":"Lim","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2022102617170764100_bib5","first-page":"e001037","article-title":"Cost-effectiveness of an insertable cardiac monitor in a high-risk population in the UK","volume":"6","author":"Rinciog","year":"2019","journal-title":"Open Heart Archives of Disease in Childhood"},{"key":"2022102617170764100_bib6","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/s42444-020-00013-9","article-title":"Accuracy of implantable loop recorders for detecting atrial tachyarrhythmias after atrial fibrillation catheter ablation","volume":"21","author":"Cho","year":"2020","journal-title":"Int J Arrhythmia"},{"key":"2022102617170764100_bib7","author":"R Core Team","year":"2017","journal-title":"R: A Language and Environment for Statistical Computing"},{"key":"2022102617170764100_bib8","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1007\/s10840-020-00815-w","article-title":"The diagnostic yield of implantable loop recorders stratified by indication: \u2018real-world\u2019 use in a large academic hospital","volume":"61","author":"Smith","year":"2020","journal-title":"J Interv Card Electrophysiol"},{"key":"2022102617170764100_bib9","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1007\/s41999-018-0128-1","article-title":"Diagnostic yield of the implantable loop recorder in octogenarians","volume":"10","author":"Lacunza-Ruiz","year":"2019","journal-title":"Eur Geriatr Med"},{"key":"2022102617170764100_bib10","doi-asserted-by":"crossref","first-page":"3707","DOI":"10.1007\/s10072-020-04963-9","article-title":"Prevalence and predictors of atrial fibrillation in patients with embolic stroke of undetermined source: a real-life single-center retrospective study","volume":"42","author":"Melis","year":"2021","journal-title":"Neurol Sci"},{"key":"2022102617170764100_bib11","doi-asserted-by":"crossref","DOI":"10.1097\/MEJ.0000000000000859","article-title":"Experience of a smartphone ambulatory ECG clinic for emergency department patients with palpitation: a single-centre cohort study","author":"Cullen","year":"2021","journal-title":"Eur J Emerg Med"},{"key":"2022102617170764100_bib12","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1016\/j.cger.2012.07.003","article-title":"Epidemiology of arrhythmias and conduction disorders in older adults","volume":"28","author":"Chow","year":"2012","journal-title":"Clin Geriatr Med"},{"key":"2022102617170764100_bib13","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1136\/pgmj.73.861.415","article-title":"Permanent cardiac pacing in elderly patients with recurrent falls, dizziness and syncope, and a hypersensitive cardioinhibitory reflex","volume":"73","author":"Crilley","year":"1997","journal-title":"Postgrad Med J"},{"key":"2022102617170764100_bib14","doi-asserted-by":"crossref","first-page":"e000177","DOI":"10.1136\/openhrt-2014-000177","article-title":"Trends in the incidence and prevalence of cardiac pacemaker insertions in an ageing population","volume":"1","author":"Bradshaw","year":"2014","journal-title":"Open Heart"},{"key":"2022102617170764100_bib15","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1111\/j.1540-8159.2011.03240.x","article-title":"Are elderly patients at increased risk of complications following pacemaker implantation? A meta-analysis of randomized trials","volume":"35","author":"Armaganijan","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"key":"2022102617170764100_bib16","doi-asserted-by":"crossref","first-page":"2169","DOI":"10.1001\/jama.2021.6470","article-title":"Effect of long-term continuous cardiac monitoring vs usual care on detection of atrial fibrillation in patients with stroke attributed to large- or small-vessel disease: the STROKE-AF randomized clinical trial","volume":"325","author":"Bernstein","year":"2021","journal-title":"JAMA"},{"key":"2022102617170764100_bib17","doi-asserted-by":"crossref","first-page":"2160","DOI":"10.1001\/jama.2021.6128","article-title":"Effect of implantable vs prolonged external electrocardiographic monitoring on atrial fibrillation detection in patients with ischemic stroke: the PER DIEM randomized clinical trial","volume":"325","author":"Buck","year":"2021","journal-title":"JAMA"}],"container-title":["European Heart Journal - Quality of Care and Clinical Outcomes"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ehjqcco\/advance-article-pdf\/doi\/10.1093\/ehjqcco\/qcab071\/41061322\/qcab071.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ehjqcco\/article-pdf\/8\/7\/770\/46648387\/qcab071.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ehjqcco\/article-pdf\/8\/7\/770\/46648387\/qcab071.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,26]],"date-time":"2022-10-26T17:17:38Z","timestamp":1666804658000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ehjqcco\/article\/8\/7\/770\/6380483"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,2]]},"references-count":17,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2021,10,2]]},"published-print":{"date-parts":[[2022,10,26]]}},"URL":"https:\/\/doi.org\/10.1093\/ehjqcco\/qcab071","relation":{},"ISSN":["2058-5225","2058-1742"],"issn-type":[{"value":"2058-5225","type":"print"},{"value":"2058-1742","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2022,11]]},"published":{"date-parts":[[2021,10,2]]}}}