{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T11:51:14Z","timestamp":1753876274003,"version":"3.41.2"},"reference-count":6,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2022,2,11]],"date-time":"2022-02-11T00:00:00Z","timestamp":1644537600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,7,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Transplantation of donation after circulatory death (DCD) donor hearts is gaining acceptance. However, DCD heart selection has been understandably cautious. We report a case of reconditioning a DCD heart using thoraco-abdominal normothermic regional perfusion in a 46-year-old donor who suffered irreversible brain injury following emergency type-A aortic dissection repair. The DCD heart was procured with cold preservation and directly transplanted into a 63-year-old male who was bridged to transplant with extracorporeal life support. The recipient required a brief period of mechanical circulatory support post-transplant but made a good recovery. To our knowledge, this is the first report of successful heart transplantation from such an extended criteria DCD donor.<\/jats:p>","DOI":"10.1093\/ejcts\/ezac083","type":"journal-article","created":{"date-parts":[[2022,1,28]],"date-time":"2022-01-28T12:08:51Z","timestamp":1643371731000},"source":"Crossref","is-referenced-by-count":1,"title":["Heart transplantation from an extended criteria donation after circulatory death donor"],"prefix":"10.1093","volume":"62","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3586-9414","authenticated-orcid":false,"given":"Ismail","family":"Vokshi","sequence":"first","affiliation":[{"name":"Transplant Unit, Royal Papworth Hospital , Cambridge, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3201-6344","authenticated-orcid":false,"given":"Stephen","family":"Large","sequence":"additional","affiliation":[{"name":"Transplant Unit, Royal Papworth Hospital , Cambridge, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9144-5376","authenticated-orcid":false,"given":"Marius","family":"Berman","sequence":"additional","affiliation":[{"name":"Transplant Unit, Royal Papworth Hospital , Cambridge, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steven","family":"Tsui","sequence":"additional","affiliation":[{"name":"Transplant Unit, Royal Papworth Hospital , Cambridge, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2022,2,11]]},"reference":[{"key":"2022072905400519600_ezac083-B1","doi-asserted-by":"crossref","first-page":"2846","DOI":"10.1111\/ajt.12927","article-title":"In situ normothermic regional perfusion for controlled donation after circulatory death\u2014the United Kingdom experience","volume":"14","author":"Oniscu","year":"2014","journal-title":"Am J Transplant"},{"key":"2022072905400519600_ezac083-B2","doi-asserted-by":"crossref","first-page":"1744","DOI":"10.1111\/ajt.12782","article-title":"Increasing the tolerance of DCD hearts to warm ischemia by pharmacological postconditioning","volume":"14","author":"Iyer","year":"2014","journal-title":"Am J Transplant"},{"key":"2022072905400519600_ezac083-B3","doi-asserted-by":"crossref","first-page":"1443","DOI":"10.1016\/j.healun.2016.07.004","article-title":"Functional assessment and transplantation of the donor heart after circulatory death","volume":"35","author":"Messer","year":"2016","journal-title":"J Heart Lung Transplant"},{"key":"2022072905400519600_ezac083-B4","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1136\/hrt.2003.024307","article-title":"Acute type A aortic dissection in a cardiac allograft recipient: case report and review of the literature","volume":"90","author":"Schellemans","year":"2004","journal-title":"Heart"},{"key":"2022072905400519600_ezac083-B5","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.1016\/j.healun.2020.10.001","article-title":"A 5-year single-center early experience of heart transplantation from donation after circulatory-determined death donors","volume":"39","author":"Messer","year":"2020","journal-title":"J Heart Lung Transplant"},{"key":"2022072905400519600_ezac083-B6","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1016\/j.healun.2018.03.017","article-title":"Human heart transplantation from donation after circulatory-determined death donors using normothermic regional perfusion and cold storage","volume":"37","author":"Messer","year":"2018","journal-title":"J Heart Lung Transplant"}],"container-title":["European Journal of Cardio-Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ejcts\/article-pdf\/62\/2\/ezac083\/45180272\/ezac083.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ejcts\/article-pdf\/62\/2\/ezac083\/45180272\/ezac083.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,29]],"date-time":"2022-07-29T05:40:30Z","timestamp":1659073230000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ejcts\/article\/doi\/10.1093\/ejcts\/ezac083\/6527000"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,11]]},"references-count":6,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022,7,11]]}},"URL":"https:\/\/doi.org\/10.1093\/ejcts\/ezac083","relation":{},"ISSN":["1010-7940","1873-734X"],"issn-type":[{"type":"print","value":"1010-7940"},{"type":"electronic","value":"1873-734X"}],"subject":[],"published-other":{"date-parts":[[2022,8,1]]},"published":{"date-parts":[[2022,2,11]]},"article-number":"ezac083"}}