{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T07:45:22Z","timestamp":1791359122798,"version":"4.3.1"},"reference-count":21,"publisher":"Oxford University Press (OUP)","issue":"5","license":[{"start":{"date-parts":[[2022,3,25]],"date-time":"2022-03-25T00:00:00Z","timestamp":1648166400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,10,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p\/>\n               <jats:sec>\n                  <jats:title>OBJECTIVES<\/jats:title>\n                  <jats:p>Transcatheter aortic valve-in-valve (ViV) procedures are increasingly performed for the treatment of degenerated surgical aortic valves with a high risk for a redo operation. For an optimal functional result, precise positioning of the transcatheter heart valve (THV) inside the SHV is crucial. The aim of this study was to systematically investigate the impact of implantation depth on the functional result after a ViV procedure in a standardized in vitro setting.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>METHODS<\/jats:title>\n                  <jats:p>A THV 23 mm (Evolut PRO) and 3 SHV 21 mm (Perimount Magna Ease, Trifecta and Hancock II) were used for hydrodynamic testing with a constant heartbeat 64\/min and a range of 55\u2013105 ml of stroke volume in 5 different positions of the THV. The following parameters were analysed: mean pressure gradient (MPG), effective orifice area (EOA), geometric orifice area, minimal internal diameter and pin-wheeling index.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>RESULTS<\/jats:title>\n                  <jats:p>MPG and EOA differed significantly regarding the position of the THV in the same SHV. The highest EOA and the lowest MPG were recorded for Evolut PRO with significance for both parameters in Hancock II at 4 vs 5 mm (P &amp;lt; 0.001), in Magna Ease at 2 mm (vs 3 mm and vs 6 mm, P &amp;lt; 0.001) and in Trifecta at 4 mm (vs 5 and 6 mm, P &amp;lt; 0.001). Leaflet coadaptation, minimal internal diameter and maximal geometric orifice area of the same TAV differ regarding the position of the TAV.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>CONCLUSIONS<\/jats:title>\n                  <jats:p>The optimal position for hydrodynamic performance of the THV as ViV differs among specific SHV models. The findings may be useful for planning a ViV procedure using the Evolut PRO THV.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/ejcts\/ezac158","type":"journal-article","created":{"date-parts":[[2022,2,24]],"date-time":"2022-02-24T20:12:44Z","timestamp":1645733564000},"source":"Crossref","is-referenced-by-count":7,"title":["Impact of different valve-in-valve positions on the hydrodynamic performance of the newest-generation self-expanding transcatheter heart valve"],"prefix":"10.1093","volume":"62","author":[{"given":"Najla","family":"Sadat","sequence":"first","affiliation":[{"name":"Department of Cardiac and Thoracic Vascular Surgery, University Medical Center Schleswig-Holstein , L\u00fcbeck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Denise","family":"Bruhn","sequence":"additional","affiliation":[{"name":"Department of Cardiac and Thoracic Vascular Surgery, University Medical Center Schleswig-Holstein , L\u00fcbeck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9331-6703","authenticated-orcid":false,"given":"Michael","family":"Scharfschwerdt","sequence":"additional","affiliation":[{"name":"Department of Cardiac and Thoracic Vascular Surgery, University Medical Center Schleswig-Holstein , L\u00fcbeck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tim","family":"Schaller","sequence":"additional","affiliation":[{"name":"Department of Cardiac and Thoracic Vascular Surgery, University Medical Center Schleswig-Holstein , L\u00fcbeck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anas","family":"Aboud","sequence":"additional","affiliation":[{"name":"Department of Cardiac and Thoracic Vascular Surgery, University Medical Center Schleswig-Holstein , L\u00fcbeck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Saisho","sequence":"additional","affiliation":[{"name":"Department of Cardiac and Thoracic Vascular Surgery, University Medical Center Schleswig-Holstein , L\u00fcbeck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6442-246X","authenticated-orcid":false,"given":"Ingo","family":"Eitel","sequence":"additional","affiliation":[{"name":"Department of Medicine II, Cardiology, Angiology and Intensive Care, University Medical Center Schleswig-Holstein , L\u00fcbeck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan","family":"Ensminger","sequence":"additional","affiliation":[{"name":"Department of Cardiac and Thoracic Vascular Surgery, University Medical Center Schleswig-Holstein , L\u00fcbeck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Buntaro","family":"Fujita","sequence":"additional","affiliation":[{"name":"Department of Cardiac and Thoracic Vascular Surgery, University Medical Center Schleswig-Holstein , L\u00fcbeck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2022,3,25]]},"reference":[{"key":"2022102811594991000_ezac158-B1","doi-asserted-by":"crossref","first-page":"2335","DOI":"10.1161\/CIRCULATIONAHA.112.104505","article-title":"Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: results from the global valve-in-valve registry","volume":"126","author":"Dvir","year":"2012","journal-title":"Circulation"},{"key":"2022102811594991000_ezac158-B2","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1001\/jama.2014.7246","article-title":"Transcatheter aortic valve implantation in failed bioprosthetic surgical valves","volume":"312","author":"Dvir","year":"2014","journal-title":"JAMA"},{"key":"2022102811594991000_ezac158-B3","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.cpcardiol.2013.10.001","article-title":"Transcatheter aortic valve-in-valve implantation for patients with degenerative surgical bioprosthetic valves","volume":"39","author":"Dvir","year":"2014","journal-title":"Curr Probl Cardiol"},{"key":"2022102811594991000_ezac158-B4","doi-asserted-by":"crossref","first-page":"s38","DOI":"10.1136\/heartjnl-2018-313517","article-title":"Transcatheter aortic valve replacement in failed surgical valves","volume":"105","author":"Simonato","year":"2019","journal-title":"Heart"},{"key":"2022102811594991000_ezac158-B5","doi-asserted-by":"crossref","first-page":"909","DOI":"10.4244\/EIJV12I7A149","article-title":"In vitro evaluation of implantation depth in valve-in-valve using different transcatheter heart valves","volume":"12","author":"Simonato","year":"2016","journal-title":"EuroIntervention"},{"key":"2022102811594991000_ezac158-B6","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1016\/j.jtcvs.2016.12.057","article-title":"Effect of transcatheter aortic valve size and position on valve-in-valve hemodynamics: an in vitro study","volume":"153","author":"Azadani","year":"2017","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2022102811594991000_ezac158-B7","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCINTERVENTIONS.115.003651","article-title":"Transcatheter replacement of failed bioprosthetic valves: large multicenter assessment of the effect of implantation depth on hemodynamics after aortic valve-in-valve","volume":"9","author":"Simonato","year":"2016","journal-title":"Circ Cardiovasc Interv"},{"key":"2022102811594991000_ezac158-B8","doi-asserted-by":"crossref","first-page":"U44","DOI":"10.4244\/EIJV10SUA7","article-title":"Valve-in-valve apps: why and how they were developed and how to use them","volume":"10","author":"Bapat","year":"2014","journal-title":"EuroIntervention"},{"key":"2022102811594991000_ezac158-B9","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1007\/s40119-017-0100-z","article-title":"From CoreValve to Evolut PRO: reviewing the journey of self-expanding transcatheter aortic valves","volume":"6","author":"Mahtta","year":"2017","journal-title":"Cardiol Ther"},{"key":"2022102811594991000_ezac158-B10","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1080\/17434440.2019.1557045","article-title":"The Evolut R and Evolut PRO transcatheter aortic valve systems","volume":"16","author":"Choudhury","year":"2019","journal-title":"Expert Rev Med Devices"},{"key":"2022102811594991000_ezac158-B11","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1097\/01.MAT.0000137038.03251.35","article-title":"The influence of a nonlinear resistance element upon in vitro aortic pressure tracings and aortic valve motions","volume":"50","author":"Scharfschwerdt","year":"2004","journal-title":"ASAIO j"},{"key":"2022102811594991000_ezac158-B12","volume-title":"Cardiovascular Implants\u2014Cardiac Valve Prostheses","author":"ISO. International Standard, ISO 5840:2015","year":"2015"},{"key":"2022102811594991000_ezac158-B13","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1093\/ejcts\/ezaa263","article-title":"Essential information on surgical heart valve characteristics for optimal valve prosthesis selection: expert consensus document from the European Association for Cardio-Thoracic Surgery (EACTS)\u2013The Society of Thoracic Surgeons (STS)\u2013American Association for Thoracic Surgery (AATS) Valve Labelling Task Force","volume":"59","author":"Durko","year":"2021","journal-title":"Eur J Cardiothorac Surg"},{"key":"2022102811594991000_ezac158-B14","doi-asserted-by":"crossref","first-page":"1618","DOI":"10.1016\/j.jcin.2016.05.030","article-title":"Valve type, size, and deployment location affect hemodynamics in an in vitro valve-in-valve model","volume":"9","author":"Midha","year":"2016","journal-title":"JACC Cardiovasc Interv"},{"key":"2022102811594991000_ezac158-B15","doi-asserted-by":"crossref","first-page":"1848","DOI":"10.1161\/CIRCULATIONAHA.109.924613","article-title":"Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves","volume":"121","author":"Webb","year":"2010","journal-title":"Circulation"},{"key":"2022102811594991000_ezac158-B16","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1007\/s10439-016-1738-8","article-title":"Transcatheter valve underexpansion limits leaflet durability: implications for valve-in-valve procedures","volume":"45","author":"Martin","year":"2017","journal-title":"Ann Biomed Eng"},{"key":"2022102811594991000_ezac158-B17","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCINTERVENTIONS.117.005216","article-title":"Bioprosthetic valve fracture improves the hemodynamic results of valve-in-valve transcatheter aortic valve replacement","volume":"10","author":"Chhatriwalla","year":"2017","journal-title":"Circ Cardiovasc Interv"},{"key":"2022102811594991000_ezac158-B18","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.jcin.2019.10.021","article-title":"Bioprosthetic valve leaflet displacement during valve-in-valve intervention: an ex vivo bench study","volume":"13","author":"Hensey","year":"2020","journal-title":"JACC Cardiovasc Interv"},{"key":"2022102811594991000_ezac158-B19","doi-asserted-by":"crossref","first-page":"1317","DOI":"10.1016\/j.jtcvs.2019.01.073","article-title":"Bioprosthetic valve fracture: technical insights from a multicenter study","volume":"158","author":"Allen","year":"2019","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2022102811594991000_ezac158-B20","doi-asserted-by":"crossref","first-page":"147","DOI":"10.15420\/icr.2019.08.R2","article-title":"Bioprosthetic aortic valve fracture during valve-in-valve transcatheter aortic valve implantation","volume":"14","author":"O'Donnell","year":"2019","journal-title":"Interv Cardiol"},{"key":"2022102811594991000_ezac158-B21","doi-asserted-by":"crossref","first-page":"541","DOI":"10.21037\/acs.2017.09.13","article-title":"Technical pitfalls and tips for the valve-in-valve procedure","volume":"6","author":"Bapat","year":"2017","journal-title":"Ann Cardiothorac Surg"}],"container-title":["European Journal of Cardio-Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ejcts\/article-pdf\/62\/5\/ezac158\/46668000\/ezac158.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ejcts\/article-pdf\/62\/5\/ezac158\/46668000\/ezac158.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,28]],"date-time":"2022-10-28T12:51:38Z","timestamp":1666961498000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ejcts\/article\/doi\/10.1093\/ejcts\/ezac158\/6554163"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,25]]},"references-count":21,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,10,4]]}},"URL":"https:\/\/doi.org\/10.1093\/ejcts\/ezac158","relation":{},"ISSN":["1010-7940","1873-734X"],"issn-type":[{"value":"1010-7940","type":"print"},{"value":"1873-734X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2022,11,1]]},"published":{"date-parts":[[2022,3,25]]},"article-number":"ezac158"}}