{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T19:00:10Z","timestamp":1778266810139,"version":"3.51.4"},"reference-count":5,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2022,7,11]],"date-time":"2022-07-11T00:00:00Z","timestamp":1657497600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,7,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>A 61-year-old male who underwent aortic valve replacement with an Inspiris Resilia\u00ae aortic bioprosthetic through an upper partial sternotomy due to severe aortic valve stenosis was presented 1\u2009year later to our hospital suffering from dyspnoea and chest pain. The transthoracic echocardiography demonstrated moderate haemodynamic structural valve deterioration with a mean gradient of 29\u2009mmHg and a valve area of 0.9 cm2. Due to relatively high-risk of reoperation, valve-in-valve transcatheter aortic valve replacement with Sapien 3\u00ae 29\u2009mm, followed by balloon valvuloplasty, was successfully performed. To the best of our knowledge, this is the first published case of valve-in-valve transcatheter aortic valve replacement into a degenerated Inspiris Resilia\u00ae aortic valve.<\/jats:p>","DOI":"10.1093\/ejcts\/ezac394","type":"journal-article","created":{"date-parts":[[2022,7,25]],"date-time":"2022-07-25T14:50:47Z","timestamp":1658760647000},"source":"Crossref","is-referenced-by-count":15,"title":["The first report of transcatheter aortic valve-in-valve implantation within the expandable Inspiris Resilia\u00ae bioprosthetic valve"],"prefix":"10.1093","volume":"62","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5794-223X","authenticated-orcid":false,"given":"Arash","family":"Mehdiani","sequence":"first","affiliation":[{"name":"Department of Cardiac Surgery, Heinrich Heine University Hospital , D\u00fcsseldorf, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8471-3582","authenticated-orcid":false,"given":"Agunda","family":"Chekhoeva","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Heinrich Heine University Hospital , D\u00fcsseldorf, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kathrin","family":"Klein","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Pneumology and Angiology, Heinrich Heine University Hospital , D\u00fcsseldorf, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8580-6369","authenticated-orcid":false,"given":"Artur","family":"Lichtenberg","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Heinrich Heine University Hospital , D\u00fcsseldorf, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2022,7,25]]},"reference":[{"key":"2022073012584316300_ezac394-B1","doi-asserted-by":"crossref","first-page":"2717","DOI":"10.1016\/j.jacc.2021.02.038","article-title":"Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research","volume":"77","author":"G\u00e9n\u00e9reux","year":"2021","journal-title":"J Am Coll Cardiol"},{"key":"2022073012584316300_ezac394-B2","doi-asserted-by":"crossref","first-page":"E598","DOI":"10.1532\/hsf.4189","article-title":"Early results after aortic valve replacement using last generation bioprosthetic aortic valve","volume":"24","author":"Useini","year":"2021","journal-title":"Heart Surg Forum"},{"key":"2022073012584316300_ezac394-B3","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1002\/ccd.30079","article-title":"Transcatheter pulmonary valve-in-valve implantation within the expandable Inspiris Resilia\u00ae bioprosthetic valve","volume":"99","author":"Batlivala","year":"2022","journal-title":"Catheter Cardiovasc Interv"},{"key":"2022073012584316300_ezac394-B4","doi-asserted-by":"crossref","first-page":"564","DOI":"10.21037\/acs-2021-tviv-25","article-title":"Bioprosthetic valve fracture: a practical guide","volume":"10","author":"Allen","year":"2021","journal-title":"Ann Cardiothorac Surg"},{"key":"2022073012584316300_ezac394-B5","doi-asserted-by":"crossref","first-page":"1317","DOI":"10.1016\/j.jtcvs.2019.01.073","article-title":"Bioprosthetic valve fracture: technical insights from a multicenter study","volume":"158","author":"Allen","year":"2019","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["European Journal of Cardio-Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ejcts\/advance-article-pdf\/doi\/10.1093\/ejcts\/ezac394\/45060132\/ezac394.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ejcts\/article-pdf\/62\/2\/ezac394\/45194436\/ezac394.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ejcts\/article-pdf\/62\/2\/ezac394\/45194436\/ezac394.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,30]],"date-time":"2022-07-30T12:59:02Z","timestamp":1659185942000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ejcts\/article\/doi\/10.1093\/ejcts\/ezac394\/6649681"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,11]]},"references-count":5,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022,7,11]]}},"URL":"https:\/\/doi.org\/10.1093\/ejcts\/ezac394","relation":{},"ISSN":["1873-734X"],"issn-type":[{"value":"1873-734X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2022,8,1]]},"published":{"date-parts":[[2022,7,11]]},"article-number":"ezac394"}}