{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T15:57:05Z","timestamp":1787500625636,"version":"build-2736575974"},"reference-count":24,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2023,6,21]],"date-time":"2023-06-21T00:00:00Z","timestamp":1687305600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p\/>\n                  <jats:sec>\n                    <jats:title>OBJECTIVES<\/jats:title>\n                    <jats:p>Core temperature monitoring is critical during cardiopulmonary bypass (CPB). In this prospective observational study, we investigated the performance of the transoesophageal echocardiography (TOE) probe for core (oesophageal) temperature monitoring during CPB.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>Thirty adult patients, 18\u201370\u2009years of either gender, undergoing cardiac surgery with CPB were enrolled. All patients received a reusable nasopharyngeal probe for monitoring core temperatures. In addition, the oesophageal temperatures were monitored with the TOE probe. The arterial outlet temperatures at the membrane oxygenator were also monitored and taken as the reference standard. Monitoring was performed every 5 min until 20\u2009min, and then at 30\u2009min during both the cooling and rewarming periods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>During cooling, the oesophageal and nasopharyngeal temperatures lagged behind the arterial outlet temperatures. However, the intra-class correlation of the oesophageal temperatures with the arterial outlet temperatures was better (range 0.58\u20130.74) than the correlation of the nasopharyngeal temperatures with the arterial outlet temperatures (range 0.46\u20130.62). During rewarming, the performance of the TOE probe was significantly superior to the nasopharyngeal probe. After 15 and 20\u2009min of rewarming, there was a difference of \u223c1\u00b0C between the oesophageal and nasopharyngeal temperatures. At 30\u2009min of rewarming, the oesophageal and the arterial outlet temperatures were similar, while the nasopharyngeal temperatures still lagged by 0.5\u00b0C. Bias was significantly less both during cooling and warming between the oesophageal temperatures and arterial outlet temperatures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>Performance of the TOE probe as an oesophageal temperature probe is superior to the nasopharyngeal probe during CPB.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical trial registration number<\/jats:title>\n                    <jats:p>CTRI no 2020\/10\/028228; ctri.nic.in.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/ejcts\/ezad242","type":"journal-article","created":{"date-parts":[[2023,6,20]],"date-time":"2023-06-20T17:58:00Z","timestamp":1687283880000},"source":"Crossref","is-referenced-by-count":2,"title":["Performance of the transoesophageal echocardiography probe as an oesophageal temperature monitor in patients undergoing cardiac surgery with cardiopulmonary bypass: a prospective observational study"],"prefix":"10.1093","volume":"64","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8097-0338","authenticated-orcid":false,"given":"Satyajeet","family":"Misra","sequence":"first","affiliation":[{"name":"Department of Anesthesiology & Critical Care, All India Institute of Medical Sciences (AIIMS) , Bhubaneswar, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prasanta Kumar","family":"Das","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology & Critical Care, All India Institute of Medical Sciences (AIIMS) , Bhubaneswar, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anand","family":"Srinivasan","sequence":"additional","affiliation":[{"name":"Department of Pharmacology, All India Institute of Medical Sciences (AIIMS) , Bhubaneswar, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2023,6,21]]},"reference":[{"key":"2023081218331258600_ezad242-B1","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1016\/j.athoracsur.2006.11.089","article-title":"Postcardiac surgical cognitive impairment in the aged using diffusion-weighted magnetic resonance imaging","volume":"83","author":"Cook","year":"2007","journal-title":"Ann Thorac Surg"},{"key":"2023081218331258600_ezad242-B2","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1067\/mtc.2001.111378","article-title":"Similar neurobehavioral outcome after valve or coronary artery operations despite differing carotid embolic counts","volume":"121","author":"Neville","year":"2001","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2023081218331258600_ezad242-B3","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1016\/S1010-7940(01)00649-2","article-title":"Stroke during coronary bypass surgery: principal role of cerebral macroemboli","volume":"19","author":"Borger","year":"2001","journal-title":"Eur J Cardiothorac Surg"},{"key":"2023081218331258600_ezad242-B4","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1051\/ject\/20023414","article-title":"A review of risk factors for adverse neurologic outcome after cardiac surgery","volume":"34","author":"Nussmeier","year":"2002","journal-title":"J Extra Corpor Technol"},{"key":"2023081218331258600_ezad242-B5","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1016\/S0003-4975(02)04370-9","article-title":"Stroke after cardiac surgery: a risk factor analysis of 16,184 consecutive adult patients","volume":"75","author":"Bucerius","year":"2003","journal-title":"Ann Thorac Surg"},{"key":"2023081218331258600_ezad242-B6","doi-asserted-by":"crossref","first-page":"1741","DOI":"10.1213\/ANE.0b013e3181c04fea","article-title":"A core review of temperature regimens and neuroprotection during cardiopulmonary bypass: does rewarming rate matter?","volume":"109","author":"Grigore","year":"2009","journal-title":"Anesth Analg"},{"key":"2023081218331258600_ezad242-B7","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1213\/01.ane.0000242535.02571.fa","article-title":"Temperature during cardiopulmonary bypass: the discrepancies between monitored sites","volume":"103","author":"Nussmeier","year":"2006","journal-title":"Anesth Analg"},{"key":"2023081218331258600_ezad242-B8","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.ejcts.2004.05.004","article-title":"Temperature monitoring during cardiopulmonary bypass\u2014do we undercool or overheat the brain?","volume":"26","author":"Kaukuntla","year":"2004","journal-title":"Eur J Cardiothorac Surg"},{"key":"2023081218331258600_ezad242-B9","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.athoracsur.2007.11.015","article-title":"Impact of intraoperative transoesophageal echocardiography on surgical decisions in 12,566 patients undergoing cardiac surgery","volume":"85","author":"Eltzschig","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"2023081218331258600_ezad242-B10","doi-asserted-by":"crossref","first-page":"380","DOI":"10.4103\/0972-5229.183902","article-title":"Hyperthermia and malfunction of transoesophageal echocardiography probe","volume":"20","author":"Choudhury","year":"2016","journal-title":"Indian J Crit Care Med"},{"key":"2023081218331258600_ezad242-B11","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1016\/S0003-4975(99)00360-4","article-title":"Influence of cardiopulmonary bypass perfusion temperature on neurologic and hematologic function after coronary artery bypass grafting","volume":"67","author":"Engelman","year":"1999","journal-title":"Ann Thorac Surg"},{"key":"2023081218331258600_ezad242-B12","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1053\/j.jvca.2014.07.026","article-title":"Neurologic injury and protection in adult cardiac and aortic surgery","volume":"29","author":"Seco","year":"2015","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"2023081218331258600_ezad242-B13","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1097\/00000542-200002000-00027","article-title":"Efficacy of two methods for reducing postbypass afterdrop","volume":"92","author":"Rajek","year":"2000","journal-title":"Anesthesiology"},{"key":"2023081218331258600_ezad242-B14","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1191\/0267659102pf536oa","article-title":"Should we rely on nasopharyngeal temperature during cardiopulmonary bypass?","volume":"17","author":"Johnson","year":"2002","journal-title":"Perfusion"},{"key":"2023081218331258600_ezad242-B15","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/S0952-8180(97)00009-3","article-title":"Continuous jugular venous versus nasopharyngeal temperature monitoring during hypothermic cardiopulmonary bypass for cardiac surgery","volume":"9","author":"Grocott","year":"1997","journal-title":"J Clin Anesth"},{"key":"2023081218331258600_ezad242-B16","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1097\/00000542-199502000-00004","article-title":"Do standard monitoring sites reflect true brain temperature when profound hypothermia is rapidly induced and reversed?","volume":"82","author":"Stone","year":"1995","journal-title":"Anesthesiology"},{"key":"2023081218331258600_ezad242-B17","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1053\/j.jvca.2003.10.030","article-title":"Massive epistaxis after nasopharyngeal temperature probe insertion after cardiac surgery","volume":"18","author":"Sinha","year":"2004","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"2023081218331258600_ezad242-B18","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1111\/j.1365-2044.2005.04112.x","article-title":"Cardiopulmonary bypass temperature and brain function","volume":"60","author":"Ali","year":"2005","journal-title":"Anaesthesia"},{"key":"2023081218331258600_ezad242-B19","doi-asserted-by":"crossref","first-page":"1559","DOI":"10.1016\/j.jtcvs.2006.11.031","article-title":"Reliability of temperatures measured at standard monitoring sites as an index of brain temperatures during deep hypothermic cardiopulmonary bypass conducted for thoracic aortic reconstruction","volume":"133","author":"Akata","year":"2007","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2023081218331258600_ezad242-B20","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1177\/0267659121995996","article-title":"Temperature management on cardiopulmonary bypass: is it standardised across Great Britain and Ireland?","volume":"37","author":"Browne","year":"2022","journal-title":"Perfusion"},{"key":"2023081218331258600_ezad242-B21","doi-asserted-by":"crossref","first-page":"735","DOI":"10.5603\/CJ.a2018.0115","article-title":"Comparison of temperature measurements in esophagus and urinary bladder in comatose patients after cardiac arrest undergoing mild therapeutic hypothermia","volume":"27","author":"Umi\u0144ska","year":"2020","journal-title":"Cardiol J"},{"key":"2023081218331258600_ezad242-B22","first-page":"163","article-title":"Consensus on hypothermia in aortic arch surgery","volume":"2","author":"Yan","year":"2013","journal-title":"Ann Cardiothorac Surg"},{"key":"2023081218331258600_ezad242-B23","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1177\/0267659111409095","article-title":"Temperature management and monitoring practices during adult cardiac surgery under cardiopulmonary bypass: results of a Canadian survey","volume":"26","author":"Belway","year":"2011","journal-title":"Perfusion"},{"key":"2023081218331258600_ezad242-B24","doi-asserted-by":"crossref","first-page":"50","DOI":"10.4103\/0972-5229.173692","article-title":"Transoesophageal echocardiography probe shutdown in a patient with hyperthermia","volume":"20","author":"Saluja","year":"2016","journal-title":"Indian J Crit Care Med"}],"container-title":["European Journal of Cardio-Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ejcts\/article-pdf\/64\/2\/ezad242\/51103977\/ezad242.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ejcts\/article-pdf\/64\/2\/ezad242\/51103977\/ezad242.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,12]],"date-time":"2023-08-12T14:33:32Z","timestamp":1691850812000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ejcts\/article\/doi\/10.1093\/ejcts\/ezad242\/7204424"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,21]]},"references-count":24,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023,8,1]]}},"URL":"https:\/\/doi.org\/10.1093\/ejcts\/ezad242","relation":{},"ISSN":["1873-734X"],"issn-type":[{"value":"1873-734X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2023,8,1]]},"published":{"date-parts":[[2023,6,21]]},"article-number":"ezad242"}}