{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T14:22:48Z","timestamp":1768314168075,"version":"3.49.0"},"reference-count":8,"publisher":"Oxford University Press (OUP)","issue":"5","license":[{"start":{"date-parts":[[2024,4,11]],"date-time":"2024-04-11T00:00:00Z","timestamp":1712793600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,5,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>When neither surgical valve replacement nor transcatheter aortic valve implantation is possible, performing an apico-aortic conduit remains a therapeutic option. This procedure has become rare and the rigid angled apical connectors usually used to facilitate ventricular anastomosis are no longer commercially available. We described the technique that we performed on a 60-year-old patient with readily available material.<\/jats:p>","DOI":"10.1093\/ejcts\/ezae160","type":"journal-article","created":{"date-parts":[[2024,4,11]],"date-time":"2024-04-11T19:44:39Z","timestamp":1712864679000},"source":"Crossref","is-referenced-by-count":1,"title":["Apico-aortic conduit: a readily available technical modification"],"prefix":"10.1093","volume":"65","author":[{"given":"Pauline","family":"Wantiez","sequence":"first","affiliation":[{"name":"Department of Thoracic, Cardiac and Vascular Surgery, University Hospital Pontchaillou , Rennes, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erwan","family":"Flecher","sequence":"additional","affiliation":[{"name":"Department of Thoracic, Cardiac and Vascular Surgery, University Hospital Pontchaillou , Rennes, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Fran\u00e7ois","family":"Heautot","sequence":"additional","affiliation":[{"name":"Department of Radiology, University Hospital Pontchaillou , Rennes, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0441-2956","authenticated-orcid":false,"given":"Geraldine","family":"Allain","sequence":"additional","affiliation":[{"name":"Department of Thoracic, Cardiac and Vascular Surgery, University Hospital Pontchaillou , Rennes, France"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2024,4,11]]},"reference":[{"key":"2024050702560452400_ezae160-B1","doi-asserted-by":"crossref","first-page":"1460","DOI":"10.1161\/CIRCULATIONAHA.108.790030","article-title":"Aortic valve bypass surgery: midterm clinical outcomes in a high-risk aortic stenosis population","volume":"118","author":"Gammie","year":"2008","journal-title":"Circulation"},{"key":"2024050702560452400_ezae160-B2","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.athoracsur.2010.03.046","article-title":"Early and midterm hemodynamics after aortic valve bypass (apicoaortic conduit) surgery","volume":"90","author":"Vliek","year":"2010","journal-title":"Ann Thorac Surg"},{"key":"2024050702560452400_ezae160-B3","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1053\/j.semtcvs.2012.01.006","article-title":"Apicoaortic conduit","volume":"24","author":"Filsoufi","year":"2012","journal-title":"Semin Thorac Cardiovasc Surg"},{"key":"2024050702560452400_ezae160-B4","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/S0003-4975(10)62226-6","article-title":"Apicoaortic valved conduits for complex left ventricular outflow obstruction: technical considerations and current status","volume":"38","author":"Brown","year":"1984","journal-title":"Ann Thorac Surg"},{"key":"2024050702560452400_ezae160-B5","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1007\/s11748-007-0111-0","article-title":"Apicoaortic bypass using a vascular graft with a bioprosthetic valve","volume":"55","author":"Fujii","year":"2007","journal-title":"Gen Thorac Cardiovasc Surg"},{"key":"2024050702560452400_ezae160-B6","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1510\/icvts.2009.213959","article-title":"Apico-aortic conduit for aortic stenosis with a porcelain aorta; technical modification for apical outflow","volume":"9","author":"Hirota","year":"2009","journal-title":"Interact CardioVasc Thorac Surg"},{"key":"2024050702560452400_ezae160-B7","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1016\/j.ejcts.2010.03.062","article-title":"Inverted graft insertion technique for apicoaortic bypass","volume":"38","author":"Nakamura","year":"2010","journal-title":"Eur J Cardiothorac Surg"},{"key":"2024050702560452400_ezae160-B8","doi-asserted-by":"crossref","first-page":"2153","DOI":"10.1111\/jocs.15473","article-title":"Aortic valve bypass for high-risk patients with symptomatic aortic stenosis: a case report","volume":"36","author":"Ye","year":"2021","journal-title":"J Card Surg"}],"container-title":["European Journal of Cardio-Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ejcts\/advance-article-pdf\/doi\/10.1093\/ejcts\/ezae160\/57218129\/ezae160.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ejcts\/article-pdf\/65\/5\/ezae160\/57421146\/ezae160.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ejcts\/article-pdf\/65\/5\/ezae160\/57421146\/ezae160.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,7]],"date-time":"2024-05-07T02:56:18Z","timestamp":1715050578000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ejcts\/article\/doi\/10.1093\/ejcts\/ezae160\/7644277"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,11]]},"references-count":8,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024,5,3]]}},"URL":"https:\/\/doi.org\/10.1093\/ejcts\/ezae160","relation":{},"ISSN":["1873-734X"],"issn-type":[{"value":"1873-734X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,5,1]]},"published":{"date-parts":[[2024,4,11]]},"article-number":"ezae160"}}