{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T11:51:03Z","timestamp":1753876263930,"version":"3.41.2"},"reference-count":16,"publisher":"Oxford University Press (OUP)","issue":"6","license":[{"start":{"date-parts":[[2025,5,21]],"date-time":"2025-05-21T00:00:00Z","timestamp":1747785600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100012550","name":"National Research, Development and Innovation Fund","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100012550","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000780","name":"European Union","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000780","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,6,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>OBJECTIVES<\/jats:title>\n                  <jats:p>Cardiogenic shock is still a major clinical challenge, despite the available devices. We developed a minimally invasive, transapical dual-lumened cannula, which can provide antegrade circulatory support and unloading for the left ventricle (LV). After using 3D printing technology, we wanted to test whether our prototypes are haemodynamically competent and implantable in an experimental large porcine model as a proof of concept study.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>METHODS<\/jats:title>\n                  <jats:p>We implanted our cannula prototypes to 7 healthy porcines via median sternotomy (n\u2009=\u20096) and via minimally invasive access (n\u2009=\u20091), transapically, under fluoroscopic control, off-pump. The cannulas were connected to a heart-lung machine, and we went from 2.5, to 3.5, 4, 4.5, 5 and 5.5\u2009l\/min flow with 15\u201315\u2009min intervals on each flow to ensure LV support. Different metabolic and haemodynamic parameters were continuously monitored.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>RESULTS<\/jats:title>\n                  <jats:p>Implantation time was 14\u2009\u00b1\u20095\u2009min. The cardiac output of the right ventricle elevated with the LV and roller pump performance from baseline of 4.81\u2009\u00b1\u20092.09 to 6.17\u2009\u00b1\u20091.02 l\/min at 5.5\u2009l\/min pump flow. Mean arterial pressure and central venous pressure changed from 68.9\u2009\u00b1\u20099.4 and 9.2\u2009\u00b1\u20092.4\u2009mmHg, to 72.8\u2009\u00b1\u200911.3 and 9.8\u2009\u00b1\u20093\u2009mmHg, respectively. Serum lactic acid and other metabolic parameters were not changed significantly.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>CONCLUSIONS<\/jats:title>\n                  <jats:p>We have successfully proved in a large animal study that our prototypes are implantable and can provide up to 5.5\u2009l\/min cardiac output. They could assist, then fully replace the function of the LV using a roller pump during our study. Further investigations are planned in the future using centrifugal pumps for longer-term support.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/ejcts\/ezaf173","type":"journal-article","created":{"date-parts":[[2025,5,21]],"date-time":"2025-05-21T21:39:20Z","timestamp":1747863560000},"source":"Crossref","is-referenced-by-count":0,"title":["Minimally invasive, transapical dual-lumened cannula for short-term left ventricular support in a clinically relevant large animal model"],"prefix":"10.1093","volume":"67","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3108-5065","authenticated-orcid":false,"given":"Marcell","family":"Sz\u00e9kely","sequence":"first","affiliation":[{"name":"Department of Cardiothoracic and Vascular Surgery, Central Hospital of Northern Pest - Military Hospital , Budapest,","place":["Hungary"]},{"name":"Heart and Vascular Center, Semmelweis University , Budapest,","place":["Hungary"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L\u00e1szl\u00f3","family":"Sz\u00e9kely","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic and Vascular Surgery, Central Hospital of Northern Pest - Military Hospital , Budapest,","place":["Hungary"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M\u00f3nika","family":"C. D\u00e9nes","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic and Vascular Surgery, Central Hospital of Northern Pest - Military Hospital , Budapest,","place":["Hungary"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tam\u00e1s","family":"Radovits","sequence":"additional","affiliation":[{"name":"Heart and Vascular Center, Semmelweis University , Budapest,","place":["Hungary"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6514-0723","authenticated-orcid":false,"given":"B\u00e9la","family":"Merkely","sequence":"additional","affiliation":[{"name":"Heart and Vascular Center, Semmelweis University , Budapest,","place":["Hungary"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Istv\u00e1n","family":"Harty\u00e1nszky","sequence":"additional","affiliation":[{"name":"Heart and Vascular Center, Semmelweis University , Budapest,","place":["Hungary"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2025,5,21]]},"reference":[{"key":"2025060601315238500_ezaf173-B1","doi-asserted-by":"crossref","first-page":"1222","DOI":"10.1097\/CCM.0000000000005919","article-title":"Advances in the management of cardiogenic shock","volume":"51","author":"Jentzer","year":"2023","journal-title":"Crit Care Med"},{"key":"2025060601315238500_ezaf173-B2","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1007\/s00392-017-1182-2","article-title":"Trends in mechanical circulatory support use and hospital mortality among patients with acute myocardial infarction and non-infarction related cardiogenic shock in the United States","volume":"107","author":"Shah","year":"2018","journal-title":"Clin Res Cardiol"},{"key":"2025060601315238500_ezaf173-B3","doi-asserted-by":"crossref","first-page":"829","DOI":"10.21037\/atm-20-2171","article-title":"Short-term mechanical circulatory support (intra-aortic balloon pump, Impella, extracorporeal membrane oxygenation, TandemHeart): a review","volume":"8","author":"Wong","year":"2020","journal-title":"Ann Transl Med"},{"key":"2025060601315238500_ezaf173-B4","first-page":"591","article-title":"Novel minimally invasive surgical approach using an external ventricular assist device and extracorporeal membrane oxygenation in refractory cardiogenic shock","volume":"51","author":"Takeda","year":"2017","journal-title":"Eur J Cardiothorac Surg"},{"key":"2025060601315238500_ezaf173-B5","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1186\/s12872-022-02826-z","article-title":"Minimally invasive apical cannulation and cannula design for short-term mechanical circulatory support devices","volume":"22","author":"Sz\u00e9kely","year":"2022","journal-title":"BMC Cardiovasc Disord"},{"key":"2025060601315238500_ezaf173-B6","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1093\/ejcts\/ezx189","article-title":"Minimally invasive CentriMag ventricular assist device support integrated with extracorporeal membrane oxygenation in cardiogenic shock patients: a comparison with conventional CentriMag biventricular support configuration","volume":"52","author":"Takeda","year":"2017","journal-title":"Eur J Cardiothorac Surg"},{"key":"2025060601315238500_ezaf173-B7","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1111\/aor.12422","article-title":"Minimally invasive ventricular assist device surgery","volume":"39","author":"Rojas","year":"2015","journal-title":"Artif Organs"},{"key":"2025060601315238500_ezaf173-B8","doi-asserted-by":"crossref","first-page":"848","DOI":"10.3390\/bioengineering11080848","article-title":"In vivo testing of a second-generation prototype accessory for single transapical left ventricular assist device implantation","volume":"11","author":"Meissner","year":"2024","journal-title":"Bioengineering (Basel)"},{"key":"2025060601315238500_ezaf173-B9","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1097\/MAT.0000000000002157","article-title":"Direct apical cannulation with protek duo rapid deployment cannula via mini thoracotomy for ambulatory venoarterial-extracorporeal membrane oxygenation","volume":"70","author":"Cappelli","year":"2024","journal-title":"ASAIO J"},{"key":"2025060601315238500_ezaf173-B10","first-page":"203","article-title":"Three-dimensional printing in adult cardiovascular medicine for surgical and transcatheter procedural planning, teaching and technological innovation","volume":"30","author":"Ferrari","year":"2020","journal-title":"Interact CardioVasc Thorac Surg"},{"key":"2025060601315238500_ezaf173-B11","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1161\/CIRCULATIONAHA.122.062949","article-title":"Extracorporeal membrane oxygenation in the therapy of cardiogenic shock: results of the ECMO-CS randomized clinical trial","volume":"147","author":"Ostadal","year":"2023","journal-title":"Circulation"},{"key":"2025060601315238500_ezaf173-B12","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1016\/j.athoracsur.2013.09.008","article-title":"Complications of extracorporeal membrane oxygenation for treatment of cardiogenic shock and cardiac arrest: a meta-analysis of 1,866 adult patients","volume":"97","author":"Cheng","year":"2014","journal-title":"Ann Thorac Surg"},{"key":"2025060601315238500_ezaf173-B13","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.pharmthera.2012.01.003","article-title":"Ventricular assist devices: pharmacological aspects of a mechanical therapy","volume":"134","author":"Wever-Pinzon","year":"2012","journal-title":"Pharmacol Ther"},{"key":"2025060601315238500_ezaf173-B14","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1002\/ejhf.668","article-title":"Concomitant implantation of Impella(\u00ae) on top of veno-arterial extracorporeal membrane oxygenation may improve survival of patients with cardiogenic shock","volume":"19","author":"Pappalardo","year":"2017","journal-title":"Eur J Heart Fail"},{"key":"2025060601315238500_ezaf173-B15","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.1056\/NEJMoa2312572","article-title":"Microaxial flow pump or standard care in infarct-related cardiogenic shock","volume":"390","author":"M\u00f8ller","year":"2024","journal-title":"N Engl J Med"},{"key":"2025060601315238500_ezaf173-B16","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1016\/j.athoracsur.2023.06.021","article-title":"Comparison of intraaortic balloon pump and impella 5.5 as heart transplant bridging strategies","volume":"116","author":"Iyengar","year":"2023","journal-title":"Ann Thorac Surg"}],"container-title":["European Journal of Cardio-Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ejcts\/advance-article-pdf\/doi\/10.1093\/ejcts\/ezaf173\/63266365\/ezaf173.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ejcts\/article-pdf\/67\/6\/ezaf173\/63266365\/ezaf173.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ejcts\/article-pdf\/67\/6\/ezaf173\/63266365\/ezaf173.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T05:32:03Z","timestamp":1749187923000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ejcts\/article\/doi\/10.1093\/ejcts\/ezaf173\/8140150"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,21]]},"references-count":16,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,6,3]]}},"URL":"https:\/\/doi.org\/10.1093\/ejcts\/ezaf173","relation":{},"ISSN":["1873-734X"],"issn-type":[{"type":"electronic","value":"1873-734X"}],"subject":[],"published-other":{"date-parts":[[2025,6]]},"published":{"date-parts":[[2025,5,21]]},"article-number":"ezaf173"}}