{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:18:34Z","timestamp":1787008714160,"version":"build-2736575974"},"reference-count":25,"publisher":"Oxford University Press (OUP)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2015,9,1]]},"DOI":"10.1093\/ejcts\/ezu449","type":"journal-article","created":{"date-parts":[[2014,11,25]],"date-time":"2014-11-25T22:46:56Z","timestamp":1416955616000},"page":"363-369","source":"Crossref","is-referenced-by-count":13,"title":["Do transvalvular pacemaker leads influence functional outcome after tricuspid ring annuloplasty?"],"prefix":"10.1093","volume":"48","author":[{"given":"Thomas","family":"Ratschiller","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, German Heart Center Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Guenther","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, German Heart Center Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Knappich","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, German Heart Center Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ralf","family":"Guenzinger","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, German Heart Center Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victoria","family":"Kehl","sequence":"additional","affiliation":[{"name":"Institute of Medical Statistics and Epidemiology, Technische Universit\u00e4t M\u00fcnchen, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernhard","family":"Voss","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, German Heart Center Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruediger","family":"Lange","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, German Heart Center Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2014,11,25]]},"reference":[{"key":"key\n\t\t\t\t2018102605303349100_EZU449C1","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1161\/CIRCULATIONAHA.106.611889","article-title":"Geometric determinants of functional tricuspid regurgitation: insights from 3-dimensional echocardiography","volume":"114","author":"Ton-Nu","year":"2006","journal-title":"Circulation"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C2","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1016\/j.jtcvs.2003.11.019","article-title":"Tricuspid valve repair: durability and risk factors for failure","volume":"127","author":"McCarthy","year":"2004","journal-title":"J Thorac Cardiovasc Surg"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C3","doi-asserted-by":"crossref","first-page":"1672","DOI":"10.1016\/j.jacc.2005.02.037","article-title":"Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads","volume":"45","author":"Lin","year":"2005","journal-title":"J Am Coll Cardiol"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C4","first-page":"523","article-title":"Tricuspid valve replacement in the presence of an endocardial pacemaker electrode","volume":"13","author":"Aris","year":"2004","journal-title":"J Heart Valve Dis"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C5","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1111\/j.1540-8159.2000.tb00821.x","article-title":"Long-term outcome of patients with multiple (\u22653) noninfected transvenous leads: a clinical and echocardiographic study","volume":"23","author":"De Cock","year":"2000","journal-title":"Pacing Clin Electrophysiol"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C6","doi-asserted-by":"crossref","first-page":"S135","DOI":"10.1111\/j.1540-8159.2008.02269.x","article-title":"Tricuspid incompetence following permanent pacemaker implantation","volume":"32","author":"Klutstein","year":"2009","journal-title":"Pacing Clin Electrophysiol"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C7","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.echo.2007.05.022","article-title":"The effect of transvenous pacemaker and implantable cardioverter defibrillator lead placement on tricuspid valve function: an observational study","volume":"21","author":"Kim","year":"2008","journal-title":"J Am Soc Echocardiogr"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C8","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1093\/ejechocard\/jeq018","article-title":"Right ventricular pacing increases tricuspid regurgitation grade regardless of the mechanical interference to the valve by the electrode","volume":"11","author":"Vaturi","year":"2010","journal-title":"Eur J Echocardiogr"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C9","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1177\/000331979504600509","article-title":"Effect of the number of ventricular leads on right ventricular hemodynamics in patients with permanent pacemaker","volume":"46","author":"Postaci","year":"1995","journal-title":"Angiology"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C10","first-page":"489","article-title":"Clinical outcome after isolated tricuspid valve replacement: 20-year experience","volume":"16","author":"Do","year":"2000","journal-title":"Can J Cardiol"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C11","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1016\/S0735-1097(02)02926-1","article-title":"Development and validation of a simple risk score to predict the need for permanent pacing after cardiac valve surgery","volume":"41","author":"Koplan","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C12","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.ejcts.2007.12.055","article-title":"Guidelines for reporting mortality and morbidity after cardiac valve interventions","volume":"33","author":"Akins","year":"2008","journal-title":"Eur J Cardiothorac Surg"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C13","doi-asserted-by":"crossref","first-page":"I577","DOI":"10.1161\/CIRCULATIONAHA.105.001263","article-title":"Tricuspid valve repair with an annuloplasty ring results in improved long-term outcomes","volume":"114","author":"Tang","year":"2006","journal-title":"Circulation"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C14","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1016\/j.jtcvs.2010.02.046","article-title":"Surgical management of secondary tricuspid valve regurgitation: annulus, commissure, or leaflet procedure?","volume":"139","author":"Navia","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C15","doi-asserted-by":"crossref","first-page":"1236","DOI":"10.1016\/j.echo.2007.03.006","article-title":"Echocardiographic follow-up of tricuspid annuloplasty with a new three-dimensional ring in patients with functional tricuspid regurgitation","volume":"20","author":"Fukuda","year":"2007","journal-title":"J Am Soc Echocardiogr"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C16","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1111\/j.1540-8191.2012.01443.x","article-title":"Mid-term results of tricuspid annuloplasty with a three-dimensional remodelling ring","volume":"27","author":"De Bonis","year":"2012","journal-title":"J Card Surg"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C17","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1016\/j.athoracsur.2013.04.100","article-title":"Transvalvular pacemaker leads increase the recurrence of regurgitation after tricuspid valve repair","volume":"96","author":"Mazine","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C18","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1161\/01.CIR.0000156449.49998.51","article-title":"Tricuspid valve tethering predicts residual tricuspid regurgitation after tricuspid annuloplasty","volume":"111","author":"Fukuda","year":"2005","journal-title":"Circulation"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C19","doi-asserted-by":"crossref","first-page":"2069","DOI":"10.1016\/j.athoracsur.2004.06.067","article-title":"Tricuspid valve repair: an old disease, a modern experience","volume":"78","author":"Bernal","year":"2004","journal-title":"Ann Thorac Surg"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C20","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.ejcts.2008.05.006","article-title":"Tricuspid valve surgery: a thirty-year assessment of early and late outcome","volume":"34","author":"Guenther","year":"2008","journal-title":"Eur J Cardiothorac Surg"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C21","doi-asserted-by":"crossref","first-page":"993","DOI":"10.1093\/ejcts\/ezs515","article-title":"Increased risk of acute kidney injury in patients undergoing tricuspid valve surgery","volume":"43","author":"Englberger","year":"2013","journal-title":"Eur J Cardiothorac Surg"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C22","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1016\/j.ejcts.2010.08.051","article-title":"Tricuspid valve repair in the presence of a permanent ventricular pacemaker lead","volume":"39","author":"Pfannmueller","year":"2011","journal-title":"Eur J Cardiothorac Surg"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C23","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1016\/j.jtcvs.2004.12.044","article-title":"Reoperations after tricuspid valve repair","volume":"130","author":"JM Bernal","year":"2005","journal-title":"J Thorac Cardiovasc Surg"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C24","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1016\/j.jtcvs.2011.06.019","article-title":"Increased risk of dehiscence after tricuspid valve repair with rigid annuloplasty rings","volume":"143","author":"Pfannmuller","year":"2012","journal-title":"J Thorac Cardiovasc Surg"},{"key":"key\n\t\t\t\t2018102605303349100_EZU449C25","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1161\/CIRCULATIONAHA.106.678664","article-title":"Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators: Results of a large prospective study","volume":"116","author":"Klug","year":"2007","journal-title":"Circulation."}],"container-title":["European Journal of Cardio-Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/ejcts\/article-pdf\/48\/3\/363\/26177484\/ezu449.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,17]],"date-time":"2019-08-17T16:44:15Z","timestamp":1566060255000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ejcts\/article\/48\/3\/363\/384501"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,11,25]]},"references-count":25,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2014,11,25]]},"published-print":{"date-parts":[[2015,9,1]]}},"URL":"https:\/\/doi.org\/10.1093\/ejcts\/ezu449","relation":{},"ISSN":["1873-734X","1010-7940"],"issn-type":[{"value":"1873-734X","type":"electronic"},{"value":"1010-7940","type":"print"}],"subject":[],"published-other":{"date-parts":[[2015,9]]},"published":{"date-parts":[[2014,11,25]]}}}