{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T23:11:13Z","timestamp":1795043473199,"version":"4.10.2"},"reference-count":26,"publisher":"Oxford University Press (OUP)","issue":"26","license":[{"start":{"date-parts":[[2021,8,26]],"date-time":"2021-08-26T00:00:00Z","timestamp":1629936000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000274","name":"British Heart Foundation","doi-asserted-by":"publisher","award":["FS\/16\/46\/32187"],"award-info":[{"award-number":["FS\/16\/46\/32187"]}],"id":[{"id":"10.13039\/501100000274","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000274","name":"British Heart Foundation","doi-asserted-by":"publisher","award":["HFHF_016"],"award-info":[{"award-number":["HFHF_016"]}],"id":[{"id":"10.13039\/501100000274","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012317","name":"NIHR Biomedical Research Centres at University College London Hospital","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100012317","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100019287","name":"Barts Health NHS Trusts","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100019287","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,7,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Aims<\/jats:title>\n                  <jats:p>Many cardiac pacemakers and defibrillators are not approved by regulators for magnetic resonance imaging (MRI). Even following generator exchange to an approved magnetic resonance (MR)-conditional model, many systems remain classified \u2018non-MR conditional\u2019 due to the leads. This classification makes patient access to MRI challenging, but there is no evidence of increased clinical risk. We compared the effect of MRI on non-MR conditional and MR-conditional pacemaker and defibrillator leads.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods and results<\/jats:title>\n                  <jats:p>Patients undergoing clinical 1.5T MRI with pacemakers and defibrillators in three centres over 5 years were included. Magnetic resonance imaging protocols were similar for MR-conditional and non-MR conditional systems. Devices were interrogated pre- and immediately post-scan, and at follow-up, and adverse clinical events recorded. Lead parameter changes peri-scan were stratified by MR-conditional labelling. A total of 1148 MRI examinations were performed in 970 patients (54% non-MR conditional systems, 39% defibrillators, 15% pacing-dependent) with 2268 leads. There were no lead-related adverse clinical events, and no clinically significant immediate or late lead parameter changes following MRI in either MR-conditional or non-MR conditional leads. Small reductions in atrial and right ventricular sensed amplitudes and impedances were similar between groups, with no difference in the proportion of leads with parameter changes greater than pre-defined thresholds (7.1%, 95% confidence interval: 6.1\u20138.3).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>There was no increased risk of MRI in patients with non-MR conditional pacemaker or defibrillator leads when following recommended protocols. Standardizing MR conditions for all leads would significantly improve access to MRI by enabling patients to be scanned in non-specialist centres, with no discernible incremental risk.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/eurheartj\/ehab350","type":"journal-article","created":{"date-parts":[[2021,5,28]],"date-time":"2021-05-28T19:51:17Z","timestamp":1622231477000},"page":"2469-2478","source":"Crossref","is-referenced-by-count":49,"title":["Evidence to support magnetic resonance conditional labelling of all pacemaker and defibrillator leads in patients with cardiac implantable electronic devices"],"prefix":"10.1093","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7532-7815","authenticated-orcid":false,"given":"Anish N","family":"Bhuva","sequence":"first","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust , London, EC1A 7BE , UK"},{"name":"Institute for Cardiovascular Science, University College London , London, WC1E 6HX , UK"},{"name":"Health Data Research UK, University College London , London , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Russell","family":"Moralee","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust , London, EC1A 7BE , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7578-2989","authenticated-orcid":false,"given":"Tamara","family":"Brunker","sequence":"additional","affiliation":[{"name":"Department of Radiology, Division of Cardiovascular Medicine, Perelman School of Medicine, University of Pennsylvania , Philadelphia, PA , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karen","family":"Lascelles","sequence":"additional","affiliation":[{"name":"Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust and National Heart and Lung Institute, Imperial College , London, SW3 6NP , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lizette","family":"Cash","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust , London, EC1A 7BE , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3433-8128","authenticated-orcid":false,"given":"Kush P","family":"Patel","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust , London, EC1A 7BE , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Lowe","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust , London, EC1A 7BE , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neha","family":"Sekhri","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust , London, EC1A 7BE , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Alpendurada","sequence":"additional","affiliation":[{"name":"Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust and National Heart and Lung Institute, Imperial College , London, SW3 6NP , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5523-1314","authenticated-orcid":false,"given":"Dudley J","family":"Pennell","sequence":"additional","affiliation":[{"name":"Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust and National Heart and Lung Institute, Imperial College , London, SW3 6NP , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0621-8241","authenticated-orcid":false,"given":"Richard","family":"Schilling","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust , London, EC1A 7BE , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pier D","family":"Lambiase","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust , London, EC1A 7BE , UK"},{"name":"Institute for Cardiovascular Science, University College London , London, WC1E 6HX , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony","family":"Chow","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust , London, EC1A 7BE , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8071-1491","authenticated-orcid":false,"given":"James C","family":"Moon","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust , London, EC1A 7BE , UK"},{"name":"Institute for Cardiovascular Science, University College London , London, WC1E 6HX , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harold","family":"Litt","sequence":"additional","affiliation":[{"name":"Department of Radiology, Division of Cardiovascular Medicine, Perelman School of Medicine, University of Pennsylvania , Philadelphia, PA , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A John","family":"Baksi","sequence":"additional","affiliation":[{"name":"Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust and National Heart and Lung Institute, Imperial College , London, SW3 6NP , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0245-7090","authenticated-orcid":false,"given":"Charlotte H","family":"Manisty","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust , London, EC1A 7BE , UK"},{"name":"Institute for Cardiovascular Science, University College London , London, WC1E 6HX , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2021,8,26]]},"reference":[{"key":"2022102513560582500_ehab350-B1","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.hrthm.2010.10.002","article-title":"Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment","volume":"8","author":"Wilkoff","year":"2011","journal-title":"Heart Rhythm"},{"key":"2022102513560582500_ehab350-B2","doi-asserted-by":"crossref","first-page":"2581","DOI":"10.1016\/j.jacc.2015.04.047","article-title":"Full-body MRI in patients with an implantable cardioverter-defibrillator","volume":"65","author":"Gold","year":"2015","journal-title":"J Am Coll Cardiol"},{"key":"2022102513560582500_ehab350-B3","doi-asserted-by":"crossref","first-page":"1378","DOI":"10.1007\/s00330-019-06449-5","article-title":"Making MRI available for patients with cardiac implantable electronic devices: growing need and barriers to change","volume":"30","author":"Bhuva","year":"2020","journal-title":"Eur Radiol"},{"key":"2022102513560582500_ehab350-B4","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1002\/jmri.24971","article-title":"Utilization and likelihood of radiologic diagnostic imaging in patients with implantable cardiac defibrillators","volume":"43","author":"Nazarian","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"2022102513560582500_ehab350-B5","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1093\/europace\/eux118","article-title":"Access to magnetic resonance imaging of patients with magnetic resonance-conditional pacemaker and implantable cardioverter defibrillator systems: results from the Really ProMRI study","volume":"20","author":"Celentano","year":"2018","journal-title":"Europace"},{"key":"2022102513560582500_ehab350-B6","doi-asserted-by":"crossref","first-page":"2555","DOI":"10.1056\/NEJMoa1604267","article-title":"Safety of magnetic resonance imaging in patients with cardiac devices","volume":"377","author":"Nazarian","year":"2017","journal-title":"N Engl J Med"},{"key":"2022102513560582500_ehab350-B7","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1056\/NEJMoa1603265","article-title":"Assessing the risks associated with MRI in patients with a pacemaker or defibrillator","volume":"376","author":"Russo","year":"2017","journal-title":"N Engl J Med"},{"key":"2022102513560582500_ehab350-B8","doi-asserted-by":"crossref","first-page":"e200086","DOI":"10.1148\/ryct.2020200086","article-title":"Safety and clinical impact of MRI in patients with non\u2013MRI-conditional cardiac devices","volume":"2","author":"Gupta","year":"2020","journal-title":"Radiol Cardiothorac Imaging"},{"key":"2022102513560582500_ehab350-B9","first-page":"425","article-title":"Provision of magnetic resonance imaging for patients with \u201cMR-conditional\u201d cardiac implantable electronic devices: n unmet clinical need","volume":"19","author":"Sabzevari","year":"2017","journal-title":"Europace"},{"key":"2022102513560582500_ehab350-B10","doi-asserted-by":"crossref","DOI":"10.1136\/openhrt-2021-001598","article-title":"Access to magnetic resonance imaging for patients with cardiac pacemakers and implantable cardioverter defibrillator","volume":"8","author":"Pieri","year":"2021","journal-title":"Open Heart"},{"key":"2022102513560582500_ehab350-B11","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1001\/jamacardio.2020.7572","article-title":"Magnetic resonance imaging in patients with cardiac implantable electronic devices with abandoned leads","volume":"6","author":"Schaller","year":"2021","journal-title":"JAMA Cardiol"},{"key":"2022102513560582500_ehab350-B12","doi-asserted-by":"crossref","first-page":"2995","DOI":"10.1093\/eurheartj\/ehx080","article-title":"The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) registry of transvenous lead extraction outcomes","volume":"38","author":"Bongiorni","year":"2017","journal-title":"Eur Heart J"},{"key":"2022102513560582500_ehab350-B13","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1161\/01.CIR.0000137121.28722.33","article-title":"Modern pacemaker and implantable cardioverter\/defibrillator systems can be magnetic resonance imaging safe","volume":"110","author":"Roguin","year":"2004","journal-title":"Circulation"},{"key":"2022102513560582500_ehab350-B14","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1093\/eurheartj\/ehi009","article-title":"In vivo heating of pacemaker leads during magnetic resonance imaging","volume":"26","author":"Luechinger","year":"2005","journal-title":"Eur Heart J"},{"key":"2022102513560582500_ehab350-B15","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/S0002-8703(97)70083-8","article-title":"Effects of magnetic resonance imaging on cardiac pacemakers and electrodes","volume":"134","author":"Achenbach","year":"1997","journal-title":"Am Heart J"},{"key":"2022102513560582500_ehab350-B16","doi-asserted-by":"crossref","first-page":"e251","DOI":"10.1111\/j.1540-8159.2011.03027.x","article-title":"High ventricular lead impedance of a DDD pacemaker after cranial magnetic resonance imaging","volume":"35","author":"Baser","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"key":"2022102513560582500_ehab350-B17","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1016\/j.hrthm.2018.02.019","article-title":"Magnetic resonance imaging safety in nonconditional pacemaker and defibrillator recipients: a meta-analysis and systematic review","volume":"15","author":"Shah","year":"2018","journal-title":"Heart Rhythm"},{"key":"2022102513560582500_ehab350-B18","doi-asserted-by":"crossref","first-page":"e97","DOI":"10.1016\/j.hrthm.2017.04.025","article-title":"2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices","volume":"14","author":"Indik","year":"2017","journal-title":"Heart Rhythm"},{"key":"2022102513560582500_ehab350-B19","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.ijcard.2019.01.005","article-title":"Clinical impact of cardiovascular magnetic resonance with optimized myocardial scar detection in patients with cardiac implantable devices","volume":"279","author":"Bhuva","year":"2019","journal-title":"Int J Cardiol"},{"key":"2022102513560582500_ehab350-B20","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/s40134-018-0301-9","article-title":"MR imaging of patients with cardiac implantable electronic devices (CIEDs): implementing a program and optimizing CMR","volume":"6","author":"Gulhane","year":"2018","journal-title":"Curr Radiol Rep"},{"key":"2022102513560582500_ehab350-B21","doi-asserted-by":"crossref","first-page":"1178","DOI":"10.1093\/ehjci\/jev305","article-title":"Clinical value of cardiovascular magnetic resonance in patients with MR-conditional pacemakers","volume":"17","author":"Raphael","year":"2016","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"2022102513560582500_ehab350-B22","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1016\/S0002-9149(98)00414-7","article-title":"Changes in pacing lead impedance over time predict lead failure","volume":"82","author":"Sharif","year":"1998","journal-title":"Am J Cardiol"},{"key":"2022102513560582500_ehab350-B23","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1016\/j.amjcard.2012.07.030","article-title":"Determining the risks of magnetic resonance imaging at 1.5 tesla for patients with pacemakers and implantable cardioverter defibrillators","volume":"110","author":"Cohen","year":"2012","journal-title":"Am J Cardiol"},{"key":"2022102513560582500_ehab350-B24","doi-asserted-by":"crossref","first-page":"e503","DOI":"10.1016\/j.hrthm.2017.09.001","article-title":"2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction","volume":"14","author":"Kusumoto","year":"2017","journal-title":"Heart Rhythm"},{"key":"2022102513560582500_ehab350-B25","doi-asserted-by":"crossref","first-page":"2495","DOI":"10.1056\/NEJMc1704179","article-title":"Risks of MRI in patients with a pacemaker or defibrillator","volume":"376","author":"Delfino","year":"2017","journal-title":"N Engl J Med"},{"key":"2022102513560582500_ehab350-B26","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1111\/pace.13713","article-title":"Premature battery depletion due to compromised low-voltage capacitor in a family of defibrillators","volume":"42","author":"Montgomery","year":"2019","journal-title":"Pacing Clin Electrophysiol"}],"container-title":["European Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/eurheartj\/article-pdf\/43\/26\/2469\/46625106\/ehab350.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/eurheartj\/article-pdf\/43\/26\/2469\/46625106\/ehab350.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,25]],"date-time":"2022-10-25T17:08:22Z","timestamp":1666717702000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/eurheartj\/article\/43\/26\/2469\/6357859"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,26]]},"references-count":26,"journal-issue":{"issue":"26","published-online":{"date-parts":[[2021,8,26]]},"published-print":{"date-parts":[[2022,7,7]]}},"URL":"https:\/\/doi.org\/10.1093\/eurheartj\/ehab350","relation":{},"ISSN":["0195-668X","1522-9645"],"issn-type":[{"value":"0195-668X","type":"print"},{"value":"1522-9645","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2022,7,7]]},"published":{"date-parts":[[2021,8,26]]}}}