{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,13]],"date-time":"2026-04-13T19:10:03Z","timestamp":1776107403476,"version":"3.50.1"},"reference-count":30,"publisher":"Oxford University Press (OUP)","issue":"Supplement_C","license":[{"start":{"date-parts":[[2023,4,26]],"date-time":"2023-04-26T00:00:00Z","timestamp":1682467200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,4,26]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Cardiac resynchronization therapy (CRT) via biventricular pacing (BVP) is a well-established therapy for patients with heart failure with reduced ejection fraction and left bundle branch block, who remain symptomatic despite optimal medical therapy. Despite the long-standing clinical evidence, as well as the familiarity of cardiac electrophysiologists with the implantation technique, CRT via BVP cannot be achieved or may result ineffective in up to one-third of the patients. Therefore, new alternative techniques, such as conduction system pacing and left ventricular pacing, are emerging as potential alternatives to this technique, not only in case of BVP failure, but also as a stand-alone first choice due to several potential advantages over traditional CRT. Specifically, due to its procedural characteristics, left bundle branch area pacing appears to be the most convincing technique, showing comparable efficacy outcomes when compared with traditional CRT, not increasing short-term device-related complications, as well as improving procedural times. However, transvenous leads remain a major limitation of all these pacing modalities. To overcome this limit, a leadless left ventricular endocardial pacing has been developed as an additional tool to achieve a left endocardial activation, although being still associated with non-negligible pitfalls, limiting its current use in clinical practice. This article focuses on the current state and latest progresses in cardiac resynchronization therapy.<\/jats:p>","DOI":"10.1093\/eurheartjsupp\/suad046","type":"journal-article","created":{"date-parts":[[2023,4,26]],"date-time":"2023-04-26T17:41:18Z","timestamp":1682530878000},"page":"C227-C233","source":"Crossref","is-referenced-by-count":10,"title":["Cardiac resynchronization therapy: present and future"],"prefix":"10.1093","volume":"25","author":[{"given":"Marco","family":"Schiavone","sequence":"first","affiliation":[{"name":"Cardiology Unit, Luigi Sacco University Hospital , Via G.B. Grassi 74, Milan 20157 , Italy"},{"name":"Department of Systems Medicine, University of Rome Tor Vergata , Rome , Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roberto","family":"Arosio","sequence":"additional","affiliation":[{"name":"Cardiology Unit, Luigi Sacco University Hospital , Via G.B. Grassi 74, Milan 20157 , Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simone","family":"Valenza","sequence":"additional","affiliation":[{"name":"Cardiology Unit, Luigi Sacco University Hospital , Via G.B. Grassi 74, Milan 20157 , Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Diego","family":"Ruggiero","sequence":"additional","affiliation":[{"name":"Cardiology Unit, Luigi Sacco University Hospital , Via G.B. Grassi 74, Milan 20157 , Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gianfranco","family":"Mitacchione","sequence":"additional","affiliation":[{"name":"Cardiology Unit, Luigi Sacco University Hospital , Via G.B. Grassi 74, Milan 20157 , Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leonida","family":"Lombardi","sequence":"additional","affiliation":[{"name":"Cardiology Unit, Luigi Sacco University Hospital , Via G.B. Grassi 74, Milan 20157 , Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maurizio","family":"Viecca","sequence":"additional","affiliation":[{"name":"Cardiology Unit, Luigi Sacco University Hospital , Via G.B. Grassi 74, Milan 20157 , Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanni Battista","family":"Forleo","sequence":"additional","affiliation":[{"name":"Cardiology Unit, Luigi Sacco University Hospital , Via G.B. Grassi 74, Milan 20157 , Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2023,4,26]]},"reference":[{"key":"2023042617375241700_suad046-B1","doi-asserted-by":"crossref","first-page":"3599","DOI":"10.1093\/eurheartj\/ehab368","article-title":"2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure","volume":"42","author":"McDonagh","year":"2021","journal-title":"Eur Heart J"},{"key":"2023042617375241700_suad046-B2","doi-asserted-by":"crossref","first-page":"1834","DOI":"10.1016\/j.jacc.2008.08.027","article-title":"Randomized trial of cardiac resynchronization in mildly symptomatic heart failure patients and in asymptomatic patients with left ventricular dysfunction and previous heart failure symptoms","volume":"52","author":"Linde","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"2023042617375241700_suad046-B3","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1016\/j.jacc.2008.10.032","article-title":"Long-Term prognosis after cardiac resynchronization therapy is related to the extent of left ventricular reverse remodeling at midterm follow-up","volume":"53","author":"Ypenburg","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"2023042617375241700_suad046-B4","doi-asserted-by":"crossref","first-page":"1456","DOI":"10.1136\/heartjnl-2014-306811","article-title":"Cardiac resynchronisation therapy is not associated with a reduction in mortality or heart failure hospitalisation in patients with non-left bundle branch block QRS morphology: meta-analysis of randomised controlled trials","volume":"101","author":"Cunnington","year":"2015","journal-title":"Heart"},{"key":"2023042617375241700_suad046-B5","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.120.008991","article-title":"Cardiac resynchronization therapy with or without defibrillation in patients with nonischemic cardiomyopathy: a systematic review and meta-analysis","volume":"14","author":"Patel","year":"2021","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2023042617375241700_suad046-B6","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1111\/pace.12883","article-title":"The effect of chronic kidney disease on mortality with cardiac resynchronization therapy","volume":"39","author":"Daly","year":"2016","journal-title":"PACE\u2014Pacing Clin Electrophysiol"},{"key":"2023042617375241700_suad046-B7","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1016\/j.cardfail.2019.07.005","article-title":"Response to cardiac resynchronization therapy across chronic kidney disease stages","volume":"25","author":"Maaten","year":"2019","journal-title":"J Card Fail"},{"key":"2023042617375241700_suad046-B8","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1067\/mhj.2000.110570","article-title":"A pilot experience with permanent biventricular pacing to treat advanced heart failure","volume":"140","author":"Leclercq","year":"2000","journal-title":"Am Heart J"},{"key":"2023042617375241700_suad046-B9","doi-asserted-by":"crossref","first-page":"2885","DOI":"10.1111\/jce.14254","article-title":"Impact of multipoint pacing on projected battery longevity in cardiac resynchronization therapy. An IRON-MPP study sub-analysis","volume":"30","author":"Forleo","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2023042617375241700_suad046-B10","doi-asserted-by":"crossref","first-page":"e007026","DOI":"10.1161\/JAHA.117.007026","article-title":"Cardiac resynchronization therapy using quadripolar versus non-quadripolar left ventricular leads programmed to biventricular pacing with single-site left ventricular pacing: impact on survival and heart failure hospitalization","volume":"6","author":"Leyva","year":"2017","journal-title":"J Am Heart Assoc"},{"key":"2023042617375241700_suad046-B11","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1093\/europace\/eun245","article-title":"Primary failure of cardiac resynchronization therapy: what are the causes and is it worth considering a second attempt? A single-centre experience","volume":"10","author":"Fatemi","year":"2008","journal-title":"Europace"},{"key":"2023042617375241700_suad046-B12","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.ijcard.2022.09.026","article-title":"Peri-procedural and mid-term follow-up age-related differences in leadless pacemaker implantation: insights from a multicenter European registry","volume":"371","author":"Gulletta","year":"2023","journal-title":"Int J Cardiol"},{"key":"2023042617375241700_suad046-B13","doi-asserted-by":"crossref","first-page":"2050","DOI":"10.1016\/j.hrthm.2021.07.008","article-title":"Long term complications in patients implanted with subcutaneous implantable defibrillators real-world data from the extended ELISIR experience","volume":"18","author":"Gasperetti","year":"2021","journal-title":"Hear Rhythm"},{"key":"2023042617375241700_suad046-B14","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1016\/j.jacc.2010.04.038","article-title":"Left ventricular endocardial stimulation for severe heart failure","volume":"56","author":"Bordachar","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"2023042617375241700_suad046-B15","doi-asserted-by":"crossref","first-page":"2118","DOI":"10.1093\/eurheartj\/ehv723","article-title":"ALternate site cardiac ResYNChronization (ALSYNC): a prospective and multicentre study of left ventricular endocardial pacing for cardiac resynchronization therapy","volume":"37","author":"Morgan","year":"2016","journal-title":"Eur Heart J"},{"key":"2023042617375241700_suad046-B16","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1093\/europace\/euw381","article-title":"Endocardial left ventricular pacing for cardiac resynchronization: systematic review and meta-analysis","volume":"20","author":"Gamble","year":"2018","journal-title":"Europace"},{"key":"2023042617375241700_suad046-B17","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1016\/j.hrthm.2020.03.002","article-title":"Real-world experience of leadless left ventricular endocardial cardiac resynchronization therapy: a multicenter international registry of the WiSE-CRT pacing system","volume":"17","author":"Sieniewicz","year":"2020","journal-title":"Hear Rhythm"},{"key":"2023042617375241700_suad046-B18","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.ccep.2021.12.010","article-title":"Physiology of left ventricular septal pacing and left bundle branch pacing","volume":"14","author":"Rijks","year":"2022","journal-title":"Card Electrophysiol Clin"},{"key":"2023042617375241700_suad046-B19","doi-asserted-by":"crossref","first-page":"e003344","DOI":"10.1161\/CIRCEP.115.003344","article-title":"Feasibility and acute hemodynamic effect of left ventricular septal pacing by transvenous approach through the interventricular septum","volume":"9","author":"Mafi-Rad","year":"2016","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2023042617375241700_suad046-B20","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.jacc.2019.11.040","article-title":"Short-term hemodynamic and electrophysiological effects of cardiac resynchronization by left ventricular septal pacing","volume":"75","author":"Salden","year":"2020","journal-title":"J Am Coll Cardiol"},{"key":"2023042617375241700_suad046-B21","doi-asserted-by":"crossref","first-page":"1548","DOI":"10.1016\/j.hrthm.2015.03.048","article-title":"His-bundle pacing versus biventricular pacing in cardiac resynchronization therapy patients: a crossover design comparison","volume":"12","author":"Lustgarten","year":"2015","journal-title":"Hear Rhythm"},{"key":"2023042617375241700_suad046-B22","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1016\/j.hrthm.2019.05.009","article-title":"On-treatment comparison between corrective his bundle pacing and biventricular pacing for cardiac resynchronization: a secondary analysis of the His-SYNC pilot trial","volume":"16","author":"Upadhyay","year":"2019","journal-title":"Hear Rhythm"},{"key":"2023042617375241700_suad046-B23","doi-asserted-by":"crossref","first-page":"1422","DOI":"10.1016\/j.jacep.2021.04.003","article-title":"A randomized trial of his pacing versus biventricular pacing in symptomatic HF patients with left bundle branch block (His-alternative)","volume":"7","author":"Vinther","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"key":"2023042617375241700_suad046-B24","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/j.jacc.2022.07.019","article-title":"Randomized trial of left bundle branch vs biventricular pacing for cardiac resynchronization therapy","volume":"80","author":"Wang","year":"2022","journal-title":"J Am Coll Cardiol"},{"key":"2023042617375241700_suad046-B25","doi-asserted-by":"crossref","first-page":"1431","DOI":"10.1016\/j.jacep.2022.08.001","article-title":"Conduction system pacing vs biventricular pacing in heart failure and wide QRS patients","volume":"8","author":"Pujol-Lopez","year":"2022","journal-title":"JACC Clin Electrophysiol"},{"key":"2023042617375241700_suad046-B26","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1161\/01.CIR.41.1.77","article-title":"Pervenous pacing of the specialized conducting system in man. His bundle and A-V nodal stimulation","volume":"41","author":"Narula","year":"1970","journal-title":"Circulation"},{"key":"2023042617375241700_suad046-B27","author":"Deshmukh","year":"2000"},{"key":"2023042617375241700_suad046-B28","doi-asserted-by":"crossref","first-page":"1272","DOI":"10.1016\/j.hrthm.2022.04.024","article-title":"Rescue left bundle branch area pacing in coronary venous lead failure or nonresponse to biventricular pacing: results from International LBBAP Collaborative Study Group","volume":"19","author":"Vijayaraman","year":"2022","journal-title":"Hear Rhythm"},{"key":"2023042617375241700_suad046-B29","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1016\/j.hrthm.2021.04.025","article-title":"Left bundle branch pacing compared to left ventricular septal myocardial pacing increases interventricular dyssynchrony but accelerates left ventricular lateral wall depolarization","volume":"18","author":"Curila","year":"2021","journal-title":"Hear Rhythm"},{"key":"2023042617375241700_suad046-B30","doi-asserted-by":"crossref","first-page":"669301","DOI":"10.3389\/fcvm.2021.669301","article-title":"Left bundle branch area pacing vs. Biventricular pacing for cardiac resynchronization therapy: a meta-analysis","volume":"8","author":"Liu","year":"2021","journal-title":"Front Cardiovasc Med"}],"container-title":["European Heart Journal Supplements"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/eurheartjsupp\/article-pdf\/25\/Supplement_C\/C227\/50100165\/suad046.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/eurheartjsupp\/article-pdf\/25\/Supplement_C\/C227\/50100165\/suad046.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,26]],"date-time":"2023-04-26T17:41:41Z","timestamp":1682530901000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/eurheartjsupp\/article\/25\/Supplement_C\/C227\/7143264"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,26]]},"references-count":30,"journal-issue":{"issue":"Supplement_C","published-online":{"date-parts":[[2023,4,26]]},"published-print":{"date-parts":[[2023,4,26]]}},"URL":"https:\/\/doi.org\/10.1093\/eurheartjsupp\/suad046","relation":{},"ISSN":["1520-765X","1554-2815"],"issn-type":[{"value":"1520-765X","type":"print"},{"value":"1554-2815","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2023,5,1]]},"published":{"date-parts":[[2023,4,26]]}}}