{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T23:56:02Z","timestamp":1793922962791,"version":"4.8.0"},"reference-count":71,"publisher":"Oxford University Press (OUP)","issue":"Supplement_G","license":[{"start":{"date-parts":[[2023,11,9]],"date-time":"2023-11-09T00:00:00Z","timestamp":1699488000000},"content-version":"vor","delay-in-days":8,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,11,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Pacing from the right ventricle is associated with an increased risk of development of congestive heart failure, increases in total and cardiac mortality, and a worsened quality of life. Conduction system pacing has become increasingly realized as an alternative to right ventricular apical pacing. Conduction system pacing from the His bundle and left bundle branch area has been shown to provide physiologic activation of the ventricle and may be an alternative to coronary sinus pacing. Conduction system pacing has been studied as an alternative for both bradycardia pacing and for heart failure pacing. In this review, we summarize the clinical results of conduction system pacing under a variety of different clinical settings. The anatomic targets of conduction system pacing are illustrated, and electrocardiographic correlates of pacing from different sites in the conduction system are defined. Ultimately, clinical trials comparing conduction system pacing with standard right ventricular apical pacing and cardiac resynchronization therapy pacing will help define its benefit and risks compared with existing techniques.<\/jats:p>","DOI":"10.1093\/eurheartjsupp\/suad114","type":"journal-article","created":{"date-parts":[[2023,11,10]],"date-time":"2023-11-10T23:47:59Z","timestamp":1699660079000},"page":"G4-G14","source":"Crossref","is-referenced-by-count":26,"title":["Conduction system pacing: overview, definitions, and nomenclature"],"prefix":"10.1093","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3318-6601","authenticated-orcid":false,"given":"Marek","family":"Jastrzebski","sequence":"first","affiliation":[{"name":"First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University, Medical College , Jakubowskiego 2, 30-688 Krakow , Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gopi","family":"Dandamudi","sequence":"additional","affiliation":[{"name":"Center for Cardiovascular Health, Virginia Mason Franciscan Heath , Seattle, WA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haran","family":"Burri","sequence":"additional","affiliation":[{"name":"Cardiac Pacing Unit, University Hospital of Geneva , Geneva , Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth A","family":"Ellenbogen","sequence":"additional","affiliation":[{"name":"Virginia Commonwealth University Medical Center , Richmond, VA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2023,11,9]]},"reference":[{"key":"2023111023465106800_suad114-B1","doi-asserted-by":"crossref","first-page":"2932","DOI":"10.1161\/01.CIR.0000072769.17295.B1","article-title":"Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction","volume":"107","author":"Sweeney","year":"2003","journal-title":"Circulation"},{"key":"2023111023465106800_suad114-B2","doi-asserted-by":"crossref","first-page":"3115","DOI":"10.1001\/jama.288.24.3115","article-title":"Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the dual chamber and VVI implantable defibrillator (DAVID) trial","volume":"288","author":"Wilkoff","year":"2002","journal-title":"JAMA"},{"key":"2023111023465106800_suad114-B3","doi-asserted-by":"crossref","first-page":"2319","DOI":"10.1016\/j.jacc.2018.02.048","article-title":"Clinical outcomes of His bundle pacing compared to right ventricular pacing","volume":"71","author":"Abdelrahman","year":"2018","journal-title":"J Am Coll Cardiol"},{"key":"2023111023465106800_suad114-B4","doi-asserted-by":"crossref","first-page":"1786","DOI":"10.1016\/j.hrthm.2017.08.009","article-title":"Incidence and predictors of late atrioventricular conduction recovery among patients requiring permanent pacemaker for complete heart block after cardiac surgery","volume":"14","author":"Kiehl","year":"2017","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B5","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1093\/eurheartj\/ehu304","article-title":"Effect of right ventricular pacing lead site on left ventricular function in patients with high-grade atrioventricular block: results of the protect-pace study","volume":"36","author":"Kaye","year":"2015","journal-title":"Eur Heart J"},{"key":"2023111023465106800_suad114-B6","doi-asserted-by":"crossref","first-page":"2140","DOI":"10.1056\/NEJMoa032423","article-title":"Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure","volume":"350","author":"Bristow","year":"2004","journal-title":"N Engl J Med"},{"key":"2023111023465106800_suad114-B7","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1056\/NEJMoa050496","article-title":"The effect of cardiac resynchronization on morbidity and mortality in heart failure","volume":"352","author":"Cleland","year":"2005","journal-title":"N Engl J Med"},{"key":"2023111023465106800_suad114-B8","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1111\/j.1540-8167.2007.00907.x","article-title":"Biventricular versus right ventricular pacing in patients with AV block (BLOCK HF): clinical study design and rationale","volume":"18","author":"Curtis","year":"2007","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2023111023465106800_suad114-B9","article-title":"Biventricular pacing for atrio-ventricular block to prevent cardiac desynchronization","author":"Blanc","year":"2014"},{"key":"2023111023465106800_suad114-B10","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1161\/01.CIR.57.3.473","article-title":"Normalization of bundle branch block patterns by distal His bundle pacing. Clinical and experimental evidence of longitudinal dissociation in the pathologic his bundle","volume":"57","author":"El-Sherif","year":"1978","journal-title":"Circulation"},{"key":"2023111023465106800_suad114-B11","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1161\/01.CIR.56.6.996","article-title":"Longitudinal dissociation in the His bundle. Bundle branch block due to asynchronous conduction within the His bundle in man","volume":"56","author":"Narula","year":"1977","journal-title":"Circulation"},{"key":"2023111023465106800_suad114-B12","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1161\/01.CIR.101.8.869","article-title":"Permanent, direct His-bundle pacing: a novel approach to cardiac pacing in patients with normal His-Purkinje activation","volume":"101","author":"Deshmukh","year":"2000","journal-title":"Circulation"},{"key":"2023111023465106800_suad114-B13","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1093\/europace\/euq038","article-title":"Permanent His-bundle pacing: seeking physiological ventricular pacing","volume":"12","author":"Barba-Pichardo","year":"2010","journal-title":"Europace"},{"key":"2023111023465106800_suad114-B14","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1007\/s10840-011-9565-1","article-title":"His and para-His pacing in AV block: feasibility and electrocardiographic findings","volume":"31","author":"Kronborg","year":"2011","journal-title":"J Interv Card Electrophysiol"},{"key":"2023111023465106800_suad114-B15","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.hrthm.2009.09.066","article-title":"Electrical resynchronization induced by direct His-bundle pacing","volume":"7","author":"Lustgarten","year":"2010","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B16","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/j.hrthm.2014.10.021","article-title":"Permanent His-bundle pacing is feasible, safe, and superior to right ventricular pacing in routine clinical practice","volume":"12","author":"Sharma","year":"2015","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B17","doi-asserted-by":"crossref","first-page":"1984","DOI":"10.1111\/jce.14064","article-title":"His bundle pacing, learning curve, procedure characteristics, safety, and feasibility: insights from a large international observational study","volume":"30","author":"Keene","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2023111023465106800_suad114-B18","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1093\/europace\/euab278","article-title":"Adopting permanent His bundle pacing: learning curves and medium-term outcomes","volume":"24","author":"de Leon","year":"2022","journal-title":"Europace"},{"key":"2023111023465106800_suad114-B19","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1053\/eupc.2002.0253","article-title":"Testing a new mechanism for left interventricular septal pacing: the transseptal route; a feasibility and safety study","volume":"4","author":"Grosfeld","year":"2002","journal-title":"Europace"},{"key":"2023111023465106800_suad114-B20","doi-asserted-by":"crossref","first-page":"e003344","DOI":"10.1161\/CIRCEP.115.003344","article-title":"Feasibility and acute hemodynamic effect of left ventricular septal pacing by transvenous approach through the interventricular septum","volume":"9","author":"Mafi-Rad","year":"2016","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2023111023465106800_suad114-B21","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1161\/CIRCEP.109.882910","article-title":"Left ventricular septal and left ventricular apical pacing chronically maintain cardiac contractile coordination, pump function and efficiency","volume":"2","author":"Mills","year":"2009","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2023111023465106800_suad114-B22","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1016\/S0735-1097(03)00091-3","article-title":"Left ventricular septal and apex pacing for optimal pump function in canine hearts","volume":"41","author":"Peschar","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"2023111023465106800_suad114-B23","doi-asserted-by":"crossref","first-page":"1736.e1","DOI":"10.1016\/j.cjca.2017.09.013","article-title":"A novel pacing strategy with low and stable output: pacing the left bundle branch immediately beyond the conduction block","volume":"33","author":"Huang","year":"2017","journal-title":"Can J Cardiol"},{"key":"2023111023465106800_suad114-B24","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1093\/europace\/euac201","article-title":"Conduction system pacing in everyday clinical practice: EHRA physician survey","volume":"25","author":"Kircanski","year":"2023","journal-title":"Europace"},{"key":"2023111023465106800_suad114-B25","doi-asserted-by":"crossref","first-page":"euad019","DOI":"10.1093\/europace\/euad019","article-title":"Conduction system pacing, a European survey: insights from clinical practice","volume":"25","author":"Keene","year":"2023","journal-title":"Europace"},{"key":"2023111023465106800_suad114-B26","doi-asserted-by":"crossref","first-page":"4161","DOI":"10.1093\/eurheartj\/ehac445","article-title":"Left bundle branch area pacing outcomes: the multicentre European MELOS study","volume":"43","author":"Jastrzebski","year":"2022","journal-title":"Eur Heart J"},{"key":"2023111023465106800_suad114-B27","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1016\/j.jacep.2020.07.004","article-title":"Initial experience, safety, and feasibility of left bundle branch area pacing: a multicenter prospective study","volume":"6","author":"Padala","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2023111023465106800_suad114-B28","doi-asserted-by":"crossref","first-page":"e009261","DOI":"10.1161\/CIRCEP.120.009261","article-title":"Long-term safety and feasibility of left bundle branch pacing in a large single-center study","volume":"14","author":"Su","year":"2021","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2023111023465106800_suad114-B29","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.hrthm.2021.08.033","article-title":"Clinical outcomes of left bundle branch area pacing compared to right ventricular pacing: results from the Geisinger-Rush Conduction System Pacing Registry","volume":"19","author":"Sharma","year":"2021","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B30","doi-asserted-by":"crossref","first-page":"2123","DOI":"10.1056\/NEJMoa0907555","article-title":"Biventricular pacing in patients with bradycardia and normal ejection fraction","volume":"361","author":"Yu","year":"2009","journal-title":"N Engl J Med"},{"key":"2023111023465106800_suad114-B31","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1002\/ejhf.2736","article-title":"Effects of haemodynamically atrio-ventricular optimized His bundle pacing on heart failure symptoms and exercise capacity: the His optimized pacing evaluated for heart failure (HOPE-HF) randomized, double-blind, cross-over trial","volume":"25","author":"Whinnett","year":"2023","journal-title":"Eur J Heart Fail"},{"key":"2023111023465106800_suad114-B32","doi-asserted-by":"crossref","first-page":"1948","DOI":"10.1016\/j.hrthm.2022.07.009","article-title":"His-bundle pacing vs biventricular pacing following atrioventricular nodal ablation in patients with atrial fibrillation and reduced ejection fraction: a multicenter, randomized, crossover study\u2014the ALTERNATIVE-AF trial","volume":"19","author":"Huang","year":"2022","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B33","doi-asserted-by":"crossref","first-page":"1697","DOI":"10.1016\/S0735-1097(03)00338-3","article-title":"The Australian intervention randomized control of rate in atrial fibrillation trial (AIRCRAFT)","volume":"41","author":"Weerasooriya","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"2023111023465106800_suad114-B34","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1023\/A:1009795330454","article-title":"The Ablate and Pace Trial: a prospective study of catheter ablation of the AV conduction system and permanent pacemaker implantation for treatment of atrial fibrillation. APT investigators","volume":"2","author":"Kay","year":"1998","journal-title":"J Interv Card Electrophysiol"},{"key":"2023111023465106800_suad114-B35","doi-asserted-by":"crossref","first-page":"953","DOI":"10.1161\/01.CIR.98.10.953","article-title":"Assessment of atrioventricular junction ablation and VVIR pacemaker versus pharmacological treatment in patients with heart failure and chronic atrial fibrillation: a randomized, controlled study","volume":"98","author":"Brignole","year":"1998","journal-title":"Circulation"},{"key":"2023111023465106800_suad114-B36","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.jacc.2019.04.026","article-title":"His corrective pacing or biventricular pacing for cardiac resynchronization in heart failure","volume":"74","author":"Upadhyay","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"2023111023465106800_suad114-B37","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1016\/j.hrthm.2019.05.009","article-title":"On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: a secondary analysis of the His-SYNC Pilot Trial","volume":"16","author":"Upadhyay","year":"2019","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B38","doi-asserted-by":"crossref","first-page":"1422","DOI":"10.1016\/j.jacep.2021.04.003","article-title":"A randomized trial of His pacing versus biventricular pacing in symptomatic HF patients with left bundle branch block (His-alternative)","volume":"7","author":"Vinther","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"key":"2023111023465106800_suad114-B39","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/j.jacc.2023.05.006","article-title":"Comparison of left bundle branch area pacing and biventricular pacing in candidates for resynchronization therapy","volume":"82","author":"Vijayaraman","year":"2023","journal-title":"J Am Coll Cardiol"},{"key":"2023111023465106800_suad114-B40","doi-asserted-by":"crossref","first-page":"1718","DOI":"10.1111\/jce.15976","article-title":"Clinical outcomes of conduction system pacing versus biventricular pacing for cardiac resynchronization therapy: a systematic review and meta-analysis","volume":"34","author":"Kim","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2023111023465106800_suad114-B41","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/j.hrthm.2017.10.014","article-title":"Permanent His-bundle pacing as an alternative to biventricular pacing for cardiac resynchronization therapy: a multicenter experience","volume":"15","author":"Sharma","year":"2018","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B42","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1093\/europace\/euab232","article-title":"2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy","volume":"24","author":"Glikson","year":"2022","journal-title":"Europace"},{"key":"2023111023465106800_suad114-B43","doi-asserted-by":"crossref","first-page":"e17","DOI":"10.1016\/j.hrthm.2023.03.1538","article-title":"2023 HRS\/APHRS\/LAHRS guideline on cardiac physiologic pacing for the avoidance and mitigation of heart failure","volume":"20","author":"Chung","year":"2023","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B44","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1016\/j.jacep.2020.11.029","article-title":"His-optimized cardiac resynchronization therapy with ventricular fusion pacing for electrical resynchronization in heart failure","volume":"7","author":"Zweerink","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"key":"2023111023465106800_suad114-B45","doi-asserted-by":"crossref","first-page":"1272","DOI":"10.1016\/j.hrthm.2022.04.024","article-title":"Rescue left bundle branch area pacing in coronary venous lead failure or nonresponse to biventricular pacing: results from international LBBAP collaborative study group","volume":"19","author":"Vijayaraman","year":"2022","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B46","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1093\/europace\/euad043","article-title":"EHRA clinical consensus statement on conduction system pacing implantation: endorsed by the Asia Pacific Heart Rhythm Society (APHRS), Canadian Heart Rhythm Society (CHRS), and Latin American Heart Rhythm Society (LAHRS)","volume":"25","author":"Burri","year":"2023","journal-title":"Europace"},{"key":"2023111023465106800_suad114-B47","article-title":"Implant, assessment and management of conduction system pacing","author":"Huang","year":"2023","journal-title":"Eur Heart J"},{"key":"2023111023465106800_suad114-B48","doi-asserted-by":"crossref","first-page":"181","DOI":"10.15420\/aer.2021.32","article-title":"The atrioventricular conduction axis and its implications for permanent pacing","volume":"10","author":"Cabrera","year":"2021","journal-title":"Arrhythm Electrophysiol Rev"},{"key":"2023111023465106800_suad114-B49","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1016\/j.jacep.2019.12.004","article-title":"Variable arrangement of the atrioventricular conduction axis within the triangle of Koch: implications for permanent His bundle pacing","volume":"6","author":"Cabrera","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2023111023465106800_suad114-B50","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1016\/j.jacep.2020.03.005","article-title":"Electrocardiographic analysis for His bundle pacing at implantation and follow-up","volume":"6","author":"Burri","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2023111023465106800_suad114-B51","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.jacep.2020.07.026","article-title":"Imaging-based localization of his bundle pacing electrodes: results from the prospective IMAGE-HBP study","volume":"7","author":"Vijayaraman","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"key":"2023111023465106800_suad114-B52","doi-asserted-by":"crossref","first-page":"85","DOI":"10.15420\/aer.2021.16","article-title":"Troubleshooting programming of conduction system pacing","volume":"10","author":"Bakelants","year":"2021","journal-title":"Arrhythm Electrophysiol Rev"},{"key":"2023111023465106800_suad114-B53","doi-asserted-by":"crossref","first-page":"e006816","DOI":"10.1161\/CIRCEP.118.006816","article-title":"Device programming for His bundle pacing","volume":"12","author":"Burri","year":"2019","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2023111023465106800_suad114-B54","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.jelectrocard.2016.07.011","article-title":"Functional aspects of His bundle physiology and pathophysiology: clinical implications","volume":"50","author":"Scherlag","year":"2017","journal-title":"J Electrocardiol"},{"key":"2023111023465106800_suad114-B55","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1161\/01.CIR.53.4.609","article-title":"Anatomical configuration of the His bundle and bundle branches in the human heart","volume":"53","author":"Massing","year":"1976","journal-title":"Circulation"},{"key":"2023111023465106800_suad114-B56","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1007\/s00276-004-0302-7","article-title":"A macroscopic anatomical investigation of atrioventricular bundle locational variation relative to the membranous part of the ventricular septum in elderly human hearts","volume":"27","author":"Kawashima","year":"2007","journal-title":"Surg Radiol Anat"},{"key":"2023111023465106800_suad114-B57","doi-asserted-by":"crossref","first-page":"2237","DOI":"10.1016\/j.hrthm.2016.08.005","article-title":"Synchronous ventricular pacing with direct capture of the atrioventricular conduction system: functional anatomy, terminology, and challenges","volume":"13","author":"Mulpuru","year":"2016","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B58","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/j.hrcr.2018.06.003","article-title":"The influence of His bundle pacing on tricuspid valve functioning using three-dimensional echocardiography","volume":"4","author":"Hasumi","year":"2018","journal-title":"HeartRhythm Case Rep"},{"key":"2023111023465106800_suad114-B59","doi-asserted-by":"crossref","first-page":"e006897","DOI":"10.1161\/CIRCEP.118.006897","article-title":"Anatomical considerations for His bundle pacing","volume":"12","author":"Nagarajan","year":"2019","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2023111023465106800_suad114-B60","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/j.hrcr.2023.03.005","article-title":"Proximal and distal right bundle branch pacing: insights into conduction system physiology","volume":"9","author":"Burri","year":"2023","journal-title":"HeartRhythm Case Rep"},{"key":"2023111023465106800_suad114-B61","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1016\/j.hrthm.2023.01.017","article-title":"Right bundle branch pacing: criteria, characteristics, and outcomes","volume":"20","author":"Jastrzebski","year":"2023","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B62","doi-asserted-by":"crossref","first-page":"1244","DOI":"10.1111\/jce.15493","article-title":"Computed tomography imaging-identified location and electrocardiographic characteristics of left bundle branch area pacing in bradycardia patients","volume":"33","author":"Chen","year":"2022","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2023111023465106800_suad114-B63","doi-asserted-by":"crossref","first-page":"1857","DOI":"10.1093\/europace\/euz275","article-title":"Electrocardiographic characterization of non-selective His-bundle pacing: validation of novel diagnostic criteria","volume":"21","author":"Jastrzebski","year":"2019","journal-title":"Europace"},{"key":"2023111023465106800_suad114-B64","doi-asserted-by":"crossref","first-page":"3010","DOI":"10.1111\/jce.15233","article-title":"Novel approach to diagnosis of His bundle capture using individualized left ventricular lateral wall activation time as reference","volume":"32","author":"Jastrzebski","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2023111023465106800_suad114-B65","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1016\/j.hrthm.2021.02.021","article-title":"Physiology-based electrocardiographic criteria for left bundle branch capture","volume":"18","author":"Jastrzebski","year":"2021","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B66","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.jacc.2019.11.040","article-title":"Short-term hemodynamic and electrophysiological effects of cardiac resynchronization by left ventricular septal pacing","volume":"75","author":"Salden","year":"2020","journal-title":"J Am Coll Cardiol"},{"key":"2023111023465106800_suad114-B67","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.hrthm.2021.07.057","article-title":"Left bundle branch-optimized cardiac resynchronization therapy (LOT-CRT): results from an international LBBAP collaborative study group","volume":"19","author":"Jastrzebski","year":"2022","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B68","doi-asserted-by":"crossref","first-page":"2027","DOI":"10.1016\/j.hrthm.2022.07.029","article-title":"Masked right bundle branch conduction delay pattern during left bundle branch pacing","volume":"19","author":"Vijayaraman","year":"2022","journal-title":"Heart Rhythm"},{"key":"2023111023465106800_suad114-B69","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.ipej.2023.07.001","article-title":"Left ventricular septal pacing\u2014can we trust the ECG?","volume":"23","author":"Curila","year":"2023","journal-title":"Indian Pacing Electrophysiol J"},{"key":"2023111023465106800_suad114-B70","doi-asserted-by":"crossref","first-page":"e006934","DOI":"10.1161\/CIRCEP.118.006934","article-title":"His-optimized cardiac resynchronization therapy to maximize electrical resynchronization: a feasibility study","volume":"12","author":"Vijayaraman","year":"2019","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2023111023465106800_suad114-B71","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/j.ccep.2021.12.006","article-title":"His-optimized and left bundle branch-optimized cardiac resynchronization therapy: in control of fusion pacing","volume":"14","author":"Zweerink","year":"2022","journal-title":"Card Electrophysiol Clin"}],"container-title":["European Heart Journal Supplements"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/eurheartjsupp\/article-pdf\/25\/Supplement_G\/G4\/53135420\/suad114.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/eurheartjsupp\/article-pdf\/25\/Supplement_G\/G4\/53135420\/suad114.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,10]],"date-time":"2023-11-10T23:48:20Z","timestamp":1699660100000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/eurheartjsupp\/article\/25\/Supplement_G\/G4\/7394451"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11]]},"references-count":71,"journal-issue":{"issue":"Supplement_G","published-online":{"date-parts":[[2023,11,9]]},"published-print":{"date-parts":[[2023,11,9]]}},"URL":"https:\/\/doi.org\/10.1093\/eurheartjsupp\/suad114","relation":{},"ISSN":["1520-765X","1554-2815"],"issn-type":[{"value":"1520-765X","type":"print"},{"value":"1554-2815","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2023,11]]},"published":{"date-parts":[[2023,11]]}}}