{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,18]],"date-time":"2026-02-18T04:14:24Z","timestamp":1771388064669,"version":"3.50.1"},"reference-count":75,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2020,11,28]],"date-time":"2020-11-28T00:00:00Z","timestamp":1606521600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,4,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>In chronic systolic heart failure and conduction system disease, cardiac resynchronization therapy (CRT) is the only known non-pharmacologic heart failure therapy that improves cardiac function, functional capacity, and survival while decreasing cardiac workload and hospitalization rates. While conventional bi-ventricular pacing has been shown to benefit patients with heart failure and conduction system disease, there are limitations to its therapeutic success, resulting in widely variable clinical response. Limitations of conventional CRT evolve around myocardial scar, fibrosis, and inability to effectively simulate diseased tissue. Studies have shown endocardial stimulation in closer proximity to the specialized conduction system is more effective when compared with epicardial stimulation. Several observational and acute haemodynamic studies have demonstrated improved electrical resynchronization and echocardiographic response with conduction system pacing (CSP). Our objective is to provide a systematic review of the evolution of CRT, and an introduction to CSP as an intriguing, though experimental physiologic alternative to conventional CRT.<\/jats:p>","DOI":"10.1093\/europace\/euaa264","type":"journal-article","created":{"date-parts":[[2020,11,22]],"date-time":"2020-11-22T20:07:07Z","timestamp":1606075627000},"page":"496-510","source":"Crossref","is-referenced-by-count":38,"title":["The evolution of cardiac resynchronization therapy and an introduction to conduction system pacing: a conceptual review"],"prefix":"10.1093","volume":"23","author":[{"given":"Bengt","family":"Herweg","sequence":"first","affiliation":[{"name":"Division of Cardiovascular Sciences, University of South Florida Morsani College of Medicine, South Tampa Center, 2 Tampa General Circle, Tampa, FL 33606, USA"},{"name":"Tampa General Hospital, USF Health South Tampa Center, 1 Tampa General Circle, Tampa, FL 33606, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Allan","family":"Welter-Frost","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Sciences, University of South Florida Morsani College of Medicine, South Tampa Center, 2 Tampa General Circle, Tampa, FL 33606, USA"},{"name":"Tampa General Hospital, USF Health South Tampa Center, 1 Tampa General Circle, Tampa, FL 33606, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2230-100X","authenticated-orcid":false,"given":"Pugazhendhi","family":"Vijayaraman","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Geisinger Commonwealth School of Medicine, Geisinger Heart Institute, MC 36-10, 1000 E Mountain Blvd, Wilkes-Barre, PA 18711, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2020,11,28]]},"reference":[{"key":"2021040708593110800_euaa264-B1","author":"Mower","year":"1990"},{"key":"2021040708593110800_euaa264-B2","doi-asserted-by":"crossref","first-page":"1974","DOI":"10.1111\/j.1540-8159.1994.tb03783.x","article-title":"Four chamber pacing in dilated cardiomyopathy","volume":"17","author":"Cazeau","year":"1994","journal-title":"Pacing Clin Electrophysiol"},{"key":"2021040708593110800_euaa264-B3","doi-asserted-by":"crossref","first-page":"2026","DOI":"10.1016\/S0735-1097(02)01895-8","article-title":"Long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay","volume":"39","author":"Auricchio","year":"2002","journal-title":"J Am Coll Cardiol"},{"key":"2021040708593110800_euaa264-B4","doi-asserted-by":"crossref","first-page":"2592","DOI":"10.1093\/eurheartj\/eht160","article-title":"Long-term impact of cardiac resynchronization therapy in mild heart failure: 5-year results from the REsynchronization reVErses Remodeling in Systolic left vEntricular dysfunction (REVERSE) study","volume":"34","author":"Linde","year":"2013","journal-title":"Eur Heart J"},{"key":"2021040708593110800_euaa264-B5","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1056\/NEJMoa0906431","article-title":"Cardiac-resynchronization therapy for the prevention of heart-failure events","volume":"361","author":"Moss","year":"2009","journal-title":"N Engl J Med"},{"key":"2021040708593110800_euaa264-B6","doi-asserted-by":"crossref","first-page":"2385","DOI":"10.1056\/NEJMoa1009540","article-title":"Cardiac-resynchronization therapy for mild-to-moderate heart failure","volume":"363","author":"Tang","year":"2010","journal-title":"N Engl J Med"},{"key":"2021040708593110800_euaa264-B7","doi-asserted-by":"crossref","first-page":"435","DOI":"10.2143\/AC.58.5.2005310","article-title":"Anodal capture with second-generation biventricular cardioverter-defibrillator","volume":"58","author":"Herweg","year":"2003","journal-title":"Acta Cardiol"},{"key":"2021040708593110800_euaa264-B8","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1111\/j.1540-8159.2006.00466.x","article-title":"Anodal capture in cardiac resynchronization therapy implications for device programming","volume":"29","author":"Tamborero","year":"2006","journal-title":"Pacing Clin Electrophysiol"},{"key":"2021040708593110800_euaa264-B9","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1111\/j.1540-8159.2006.00404.x","article-title":"Latency during left ventricular pacing from the lateral cardiac veins: a cause of ineffectual biventricular pacing","volume":"29","author":"Herweg","year":"2006","journal-title":"Pacing Clin Electrophysiol"},{"key":"2021040708593110800_euaa264-B10","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.1111\/j.1540-8159.2010.02882.x","article-title":"Site-specific differences in latency intervals during biventricular pacing: impact on paced QRS morphology and echo-optimized V-V interval","volume":"33","author":"Herweg","year":"2010","journal-title":"Pacing Clin Electrophysiol"},{"key":"2021040708593110800_euaa264-B11","doi-asserted-by":"crossref","first-page":"476","DOI":"10.5603\/CJ.2011.0002","article-title":"Usefulness of the 12-lead electrocardiogram in the follow-up of patients with cardiac resynchronization devices. Part I","volume":"18","author":"Barold","year":"2011","journal-title":"Cardiol J"},{"key":"2021040708593110800_euaa264-B12","doi-asserted-by":"crossref","first-page":"2305","DOI":"10.1016\/j.jacc.2005.02.098","article-title":"The hemodynamic effect of intrinsic conduction during left ventricular pacing as compared to biventricular pacing","volume":"46","author":"van Gelder","year":"2005","journal-title":"J Am Coll Cardiol"},{"key":"2021040708593110800_euaa264-B13","doi-asserted-by":"crossref","first-page":"944","DOI":"10.1016\/j.ahj.2010.02.034","article-title":"Rationale and design of a randomized clinical trial to assess the safety and efficacy of frequent optimization of cardiac resynchronization therapy: the Frequent Optimization Study Using the QuickOpt Method (FREEDOM) trial","volume":"159","author":"Abraham","year":"2010","journal-title":"Am Heart J"},{"key":"2021040708593110800_euaa264-B14","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1111\/j.1540-8159.2009.02581.x","article-title":"SmartDelay determined AV optimization: a comparison of AV delay methods used in cardiac resynchronization therapy (SMART-AV): rationale and design","volume":"33","author":"Stein","year":"2010","journal-title":"Pacing Clin Electrophysiol"},{"key":"2021040708593110800_euaa264-B15","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1016\/j.ahj.2012.02.007","article-title":"A novel algorithm for individualized cardiac resynchronization therapy: rationale and design of the adaptive cardiac resynchronization therapy trial","volume":"163","author":"Krum","year":"2012","journal-title":"Am Heart J"},{"key":"2021040708593110800_euaa264-B16","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.117.007489","article-title":"Programming cardiac resynchronization therapy for electrical synchrony: reaching beyond left-bundle-branch block and left ventricular activation delay","volume":"7","author":"Varma","year":"2018","journal-title":"J Am Heart Assoc"},{"key":"2021040708593110800_euaa264-B17","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.1016\/j.hrthm.2019.01.020","article-title":"Dynamic programming of atrioventricular delay improves electrical synchrony in a multicenter cardiac resynchronization therapy study","volume":"16","author":"Thibault","year":"2019","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B18","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1016\/j.hrthm.2013.07.007","article-title":"Clinical outcomes with synchronized left ventricular pacing: analysis of the adaptive CRT trial","volume":"10","author":"Birnie","year":"2013","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B19","doi-asserted-by":"crossref","first-page":"1807","DOI":"10.1016\/j.hrthm.2012.07.009","article-title":"Investigation of a novel algorithm for synchronized left-ventricular pacing and ambulatory optimization of cardiac resynchronization therapy: results of the adaptive CRT trial","volume":"9","author":"Martin","year":"2012","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B20","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1016\/j.hrthm.2019.05.012","article-title":"Adaptive cardiac resynchronization therapy is associated with decreased risk of incident atrial fibrillation compared to standard biventricular pacing: a real-world analysis of 37,450 patients followed by remote monitoring","volume":"16","author":"Hsu","year":"2019","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B21","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.1016\/j.jacc.2007.11.074","article-title":"A randomized comparison of triple-site versus dual-site ventricular stimulation in patients with congestive heart failure","volume":"51","author":"Leclercq","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"2021040708593110800_euaa264-B22","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.ijcard.2007.12.009","article-title":"Mid-term outcomes of triple-site vs. conventional cardiac resynchronization therapy: a preliminary study","volume":"133","author":"Lenarczyk","year":"2009","journal-title":"Int J Cardiol"},{"key":"2021040708593110800_euaa264-B23","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1093\/eurjhf\/hfs004","article-title":"A randomized double-blind crossover trial of triventricular versus biventricular pacing in heart failure","volume":"14","author":"Rogers","year":"2012","journal-title":"Eur J Heart Fail"},{"key":"2021040708593110800_euaa264-B24","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1016\/j.jacep.2016.05.015","article-title":"Long-term results of triventricular versus biventricular pacing in heart failure: a propensity-matched comparison","volume":"2","author":"Providencia","year":"2016","journal-title":"JACC Clin Electrophysiol"},{"key":"2021040708593110800_euaa264-B25","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1093\/europace\/euu290","article-title":"Hospitalization rates and associated cost analysis of cardiac resynchronization therapy with an implantable defibrillator and quadripolar vs. bipolar left ventricular leads: a comparative effectiveness study","volume":"17","author":"Forleo","year":"2015","journal-title":"Europace"},{"key":"2021040708593110800_euaa264-B26","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/j.jacep.2016.02.007","article-title":"Reduced mortality associated with quadripolar compared to bipolar left ventricular leads in cardiac resynchronization therapy","volume":"2","author":"Turakhia","year":"2016","journal-title":"JACC Clin Electrophysiol"},{"key":"2021040708593110800_euaa264-B27","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1093\/europace\/eur240","article-title":"Beneficial effects of right ventricular non-apical vs. apical pacing: a systematic review and meta-analysis of randomized-controlled trials","volume":"14","author":"Shimony","year":"2012","journal-title":"Europace"},{"key":"2021040708593110800_euaa264-B28","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1186\/1532-429X-13-29","article-title":"Cardiac resynchronization therapy guided by late gadolinium-enhancement cardiovascular magnetic resonance","volume":"13","author":"Leyva","year":"2011","journal-title":"J Cardiovasc Magn Reson"},{"key":"2021040708593110800_euaa264-B29","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1016\/j.hrthm.2013.11.023","article-title":"Multipoint left ventricular pacing improves acute hemodynamic response assessed with pressure-volume loops in cardiac resynchronization therapy patients","volume":"11","author":"Pappone","year":"2014","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B30","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/j.hrthm.2015.01.034","article-title":"Multipoint pacing by a left ventricular quadripolar lead improves the acute hemodynamic response to CRT compared with conventional biventricular pacing at any site","volume":"12","author":"Zanon","year":"2015","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B31","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1016\/j.hrthm.2015.02.008","article-title":"Improving cardiac resynchronization therapy response with multipoint left ventricular pacing: twelve-month follow-up study","volume":"12","author":"Pappone","year":"2015","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B32","doi-asserted-by":"crossref","first-page":"1644","DOI":"10.1016\/j.hrthm.2016.05.015","article-title":"Optimization of left ventricular pacing site plus multipoint pacing improves remodeling and clinical response to cardiac resynchronization therapy at 1 year","volume":"13","author":"Zanon","year":"2016","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B33","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1007\/s00392-019-01499-7","article-title":"Multipoint left ventricular pacing with large anatomical separation improves reverse remodeling and response to cardiac resynchronization therapy in responders and non-responders to conventional biventricular pacing","volume":"109","author":"Schiedat","year":"2020","journal-title":"Clin Res Cardiol"},{"key":"2021040708593110800_euaa264-B34","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1111\/jce.14433","article-title":"Clinical and economic impact of multipoint left ventricular pacing: a comparative analysis from the Italian registry on multipoint pacing in cardiac resynchronization therapy (IRON-MPP)","volume":"31","author":"Forleo","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2021040708593110800_euaa264-B35","doi-asserted-by":"crossref","first-page":"2979","DOI":"10.1093\/eurheartj\/ehz109","article-title":"Cardiac resynchronization therapy non-responder to responder conversion rate in the more response to cardiac resynchronization therapy with MultiPoint Pacing (MORE-CRT MPP) study: results from Phase I","volume":"40","author":"Leclercq","year":"2019","journal-title":"Eur Heart J"},{"key":"2021040708593110800_euaa264-B36","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1016\/j.jacep.2017.06.022","article-title":"Safety and efficacy of multipoint pacing in cardiac resynchronization therapy: the multipoint pacing trial","volume":"3","author":"Niazi","year":"2017","journal-title":"JACC Clin Electrophysiol"},{"key":"2021040708593110800_euaa264-B37","doi-asserted-by":"crossref","first-page":"e0154024","DOI":"10.1371\/journal.pone.0154024","article-title":"In heart failure patients with left-bundle-branch block single lead multispot left ventricular pacing does not improve acute hemodynamic response to conventional biventricular pacing. A multicenter prospective, interventional, non-randomized study","volume":"11","author":"Sterli\u0144ski","year":"2016","journal-title":"PLoS One"},{"key":"2021040708593110800_euaa264-B38","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.1093\/europace\/eux209","article-title":"Estimation of the effects of multipoint pacing on battery longevity in routine clinical practice","volume":"20","author":"Akerstrom","year":"2018","journal-title":"Europace"},{"key":"2021040708593110800_euaa264-B39","doi-asserted-by":"crossref","first-page":"2128","DOI":"10.1111\/j.1540-8159.1998.tb01133.x","article-title":"Endocardial biventricular pacing","volume":"21","author":"Jais","year":"1998","journal-title":"Pacing Clin Electrophysiol"},{"key":"2021040708593110800_euaa264-B40","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1161\/CIRCEP.108.846022","article-title":"Left ventricular endocardial pacing improves resynchronization therapy in canine left bundle-branch hearts","volume":"2","author":"van Deursen","year":"2009","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2021040708593110800_euaa264-B41","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.jacc.2009.08.045","article-title":"Optimizing hemodynamics in heart failure patients by systematic screening of left ventricular pacing sites: the lateral left ventricular wall and the coronary sinus are rarely the best sites","volume":"55","author":"Derval","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"2021040708593110800_euaa264-B42","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1016\/j.jacc.2010.04.038","article-title":"Left ventricular endocardial stimulation for severe heart failure","volume":"56","author":"Bordachar","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"2021040708593110800_euaa264-B43","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.hrthm.2014.01.031","article-title":"Mid-term follow up of thromboembolic complications in left ventricular endocardial cardiac resynchronization therapy","volume":"11","author":"Rademakers","year":"2014","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B44","doi-asserted-by":"crossref","first-page":"2118","DOI":"10.1093\/eurheartj\/ehv723","article-title":"ALternate Site Cardiac ResYNChronization (ALSYNC): a prospective and multicentre study of left ventricular endocardial pacing for cardiac resynchronization therapy","volume":"37","author":"Morgan","year":"2016","journal-title":"Eur Heart J"},{"key":"2021040708593110800_euaa264-B45","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.ahj.2019.04.002","article-title":"Design and rationale for the Stimulation Of the Left Ventricular Endocardium for Cardiac Resynchronization Therapy in non-responders and previously untreatable patients (SOLVE-CRT) trial","volume":"217","author":"Singh","year":"2019","journal-title":"Am Heart J"},{"key":"2021040708593110800_euaa264-B46","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1161\/CIRCEP.109.882910","article-title":"Left ventricular septal and left ventricular apical pacing chronically maintain cardiac contractile coordination, pump function and efficiency","volume":"2","author":"Mills","year":"2009","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2021040708593110800_euaa264-B47","doi-asserted-by":"crossref","first-page":"e003344","DOI":"10.1161\/CIRCEP.115.003344","article-title":"Feasibility and acute hemodynamic effect of left ventricular septal pacing by transvenous approach through the interventricular septum","volume":"9","author":"Mafi-Rad","year":"2016","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2021040708593110800_euaa264-B48","doi-asserted-by":"crossref","first-page":"1548","DOI":"10.1016\/j.hrthm.2015.03.048","article-title":"His-bundle pacing versus biventricular pacing in cardiac resynchronization therapy patients: a crossover design comparison","volume":"12","author":"Lustgarten","year":"2015","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B49","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1016\/j.hrthm.2017.04.003","article-title":"Permanent His-bundle pacing for cardiac resynchronization therapy: initial feasibility study in lieu of left ventricular lead","volume":"14","author":"Ajijola","year":"2017","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B50","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/j.hrthm.2017.10.014","article-title":"Permanent His-bundle pacing as an alternative to biventricular pacing for cardiac resynchronization therapy: a multicenter experience","volume":"15","author":"Sharma","year":"2018","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B51","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1136\/heartjnl-2018-313415","article-title":"Long-term outcomes of His-bundle-pacing in patients with heart failure with left-bundle-branch block","volume":"105","author":"Huang","year":"2019","journal-title":"Heart"},{"key":"2021040708593110800_euaa264-B52","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.jacc.2019.04.026","article-title":"His corrective pacing or biventricular pacing for cardiac resynchronization in heart failure","volume":"74","author":"Upadhyay","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"2021040708593110800_euaa264-B53","doi-asserted-by":"crossref","first-page":"1736.e1731","DOI":"10.1016\/j.cjca.2017.09.013","article-title":"A novel pacing strategy with low and stable output: pacing the left-bundle-branch immediately beyond the conduction block","volume":"33","author":"Huang","year":"2017","journal-title":"Can J Cardiol"},{"key":"2021040708593110800_euaa264-B54","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1016\/j.hrthm.2019.05.011","article-title":"Prospective evaluation of feasibility and electrophysiologic and echocardiographic characteristics of left-bundle-branch area pacing","volume":"16","author":"Vijayaraman","year":"2019","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B55","doi-asserted-by":"crossref","first-page":"3039","DOI":"10.1016\/j.jacc.2019.10.039","article-title":"Left-bundle-branch pacing: JACC review topic of the week","volume":"74","author":"Zhang","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"2021040708593110800_euaa264-B56","doi-asserted-by":"crossref","first-page":"1694","DOI":"10.1093\/europace\/euz188","article-title":"Feasibility and cardiac synchrony of permanent left-bundle-branch pacing through the interventricular septum","volume":"21","author":"Hou","year":"2019","journal-title":"Europace"},{"key":"2021040708593110800_euaa264-B57","doi-asserted-by":"crossref","first-page":"3112","DOI":"10.1016\/j.jacc.2018.09.073","article-title":"His resynchronization versus biventricular pacing in patients with heart failure and left-bundle-branch block","volume":"72","author":"Arnold","year":"2018","journal-title":"J Am Coll Cardiol"},{"key":"2021040708593110800_euaa264-B58","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.jacc.2019.11.040","article-title":"Short-term hemodynamic and electrophysiological effects of cardiac resynchronization by left ventricular septal pacing","volume":"75","author":"Salden","year":"2020","journal-title":"J Am Coll Cardiol"},{"key":"2021040708593110800_euaa264-B59","doi-asserted-by":"crossref","first-page":"e006613","DOI":"10.1161\/CIRCEP.118.006613","article-title":"Permanent his-bundle-pacing for cardiac resynchronization therapy in patients with heart failure and right bundle branch block","volume":"11","author":"Sharma","year":"2018","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2021040708593110800_euaa264-B60","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1111\/pace.12997","article-title":"Utilization of permanent his-bundle pacing for management of proarrhythmia related to biventricular pacing","volume":"40","author":"Sofi","year":"2017","journal-title":"Pacing Clin Electrophysiol"},{"key":"2021040708593110800_euaa264-B61","first-page":"A16112","article-title":"Could cardiac re-synchronization via his-bundle-pacing reduce arrhythmic risk?","volume":"136","author":"Logue","year":"2018","journal-title":"Circulation"},{"key":"2021040708593110800_euaa264-B62","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1161\/01.CIR.57.3.473","article-title":"Normalization of bundle branch block patterns by distal His-bundle-pacing. Clinical and experimental evidence of longitudinal dissociation in the pathologic His-bundle","volume":"57","author":"El-Sherif","year":"1978","journal-title":"Circulation"},{"key":"2021040708593110800_euaa264-B63","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1093\/europace\/eus228","article-title":"Ventricular resynchronization therapy by direct His-bundle pacing using an internal cardioverter defibrillator","volume":"15","author":"Barba-Pichardo","year":"2013","journal-title":"Europace"},{"key":"2021040708593110800_euaa264-B64","doi-asserted-by":"crossref","first-page":"3547","DOI":"10.1093\/eurheartj\/eht290","article-title":"An individual patient meta-analysis of five randomized trials assessing the effects of cardiac resynchronization therapy on morbidity and mortality in patients with symptomatic heart failure","volume":"34","author":"Cleland","year":"2013","journal-title":"Eur Heart J"},{"key":"2021040708593110800_euaa264-B65","doi-asserted-by":"crossref","first-page":"e014253","DOI":"10.1161\/JAHA.119.014253","article-title":"Feasibility and efficacy of His-bundle-pacing or left bundle pacing combined with atrioventricular node ablation in patients with persistent atrial fibrillation and implantable cardioverter-defibrillator therapy","volume":"8","author":"Wang","year":"2019","journal-title":"J Am Heart Assoc"},{"key":"2021040708593110800_euaa264-B66","author":"Vijayaraman","year":"2020;:10.1016\/..2020.08.015"},{"key":"2021040708593110800_euaa264-B67","doi-asserted-by":"crossref","first-page":"e006934","DOI":"10.1161\/CIRCEP.118.006934","article-title":"His-optimized cardiac resynchronization therapy to maximize electrical resynchronization: a feasibility study","volume":"12","author":"Vijayaraman","year":"2019","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2021040708593110800_euaa264-B68","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/j.jacep.2016.01.010","article-title":"A possible role for pacing the left ventricular septum in cardiac resynchronization therapy","volume":"2","author":"Rademakers","year":"2016","journal-title":"JACC Clin Electrophysiol"},{"key":"2021040708593110800_euaa264-B69","doi-asserted-by":"crossref","first-page":"1984","DOI":"10.1111\/jce.14064","article-title":"His-bundle-pacing, learning curve, procedure characteristics, safety, and feasibility: insights from a large international observational study","volume":"30","author":"Keene","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2021040708593110800_euaa264-B70","doi-asserted-by":"crossref","first-page":"1791","DOI":"10.1016\/j.hrthm.2019.06.016","article-title":"A beginner\u2019s guide to permanent left-bundle-branch pacing","volume":"16","author":"Huang","year":"2019","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B71","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1016\/j.jacep.2020.04.011","article-title":"Cardiac Resynchronization Therapy in Patients With Nonischemic Cardiomyopathy Using Left Bundle Branch Pacing","volume":"6","author":"Huang","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2021040708593110800_euaa264-B72","article-title":"Left-bundle-branch pacing for cardiac resynchronization therapy: non-randomized on treatment comparison with His-bundle-pacing and biventricular pacing","author":"Wu","year":"2020","journal-title":"Can J Cardiol"},{"key":"2021040708593110800_euaa264-B73","doi-asserted-by":"crossref","first-page":"e006801","DOI":"10.1161\/CIRCEP.118.006801","article-title":"Direct visualization of the His-bundle-pacing lead placement by 3-dimensional electroanatomic mapping: technique, anatomy, and practical considerations","volume":"12","author":"Orlov","year":"2019","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2021040708593110800_euaa264-B74","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1016\/j.hrthm.2019.06.005","article-title":"Extraction of the permanent His-bundle-pacing lead: safety outcomes and feasibility of reimplantation","volume":"16","author":"Vijayaraman","year":"2019","journal-title":"Heart Rhythm"},{"key":"2021040708593110800_euaa264-B75","doi-asserted-by":"crossref","first-page":"e147","DOI":"10.1016\/j.jacc.2013.05.019","article-title":"ACCF\/AHA guideline for the management of heart failure: a report of the American College of Cardiology Foundation\/American Heart Association Task Force on Practice Guidelines","volume":"62","author":"Yancy","year":"2013","journal-title":"J Am Coll Cardiol"}],"container-title":["EP Europace"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/europace\/article-pdf\/23\/4\/496\/36916586\/euaa264.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/europace\/article-pdf\/23\/4\/496\/36916586\/euaa264.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T09:00:37Z","timestamp":1617786037000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/23\/4\/496\/6008995"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11,28]]},"references-count":75,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020,11,28]]},"published-print":{"date-parts":[[2021,4,6]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/euaa264","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2021,4,1]]},"published":{"date-parts":[[2020,11,28]]}}}