{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T23:36:06Z","timestamp":1793144166512,"version":"4.5.0"},"reference-count":36,"publisher":"Oxford University Press (OUP)","issue":"Supplement_2","license":[{"start":{"date-parts":[[2020,12,1]],"date-time":"2020-12-01T00:00:00Z","timestamp":1606780800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"funder":[{"name":"Key Research and Development Program of Zhejiang","award":["2019C03012"],"award-info":[{"award-number":["2019C03012"]}]},{"name":"Natural Science for Youth Foundation","award":["81900345"],"award-info":[{"award-number":["81900345"]}]},{"name":"Major Project of the Science and Technology of Wenzhou","award":["ZS2017010"],"award-info":[{"award-number":["ZS2017010"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,12,26]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>It is well recognized that a high burden of right ventricular pacing results in deleterious clinical outcomes over the long term. His bundle pacing can achieve optimal ventricular synchronization; however, relatively high pacing thresholds, low R-wave amplitudes, and the long-term performance have been concerns. Recently, left ventricular (LV) septal endocardium pacing (LVSP) has demonstrated improved acute haemodynamics. Another novel technique of intraseptal left bundle branch pacing (LBBP) via transvenous approach has been adopted rapidly and has demonstrated its feasibility and effectiveness. This article reviews the clinical application and differences between LVSP and LBBP. Compared with LVSP, LBBP has strict criteria for left conduction system capture and lead location. In addition to LV septal capture it also stimulates the proximal left bundle branch, resulting in rapid and physiological LV activation. With a uniformity and standardization of the implant procedure and definitions, it may be possible to achieve widespread application of this form of physiological pacing.<\/jats:p>","DOI":"10.1093\/europace\/euaa297","type":"journal-article","created":{"date-parts":[[2020,12,9]],"date-time":"2020-12-09T22:30:33Z","timestamp":1607553033000},"page":"ii10-ii18","source":"Crossref","is-referenced-by-count":56,"title":["Novel left ventricular cardiac synchronization: left ventricular septal pacing or left bundle branch pacing?"],"prefix":"10.1093","volume":"22","author":[{"given":"Shengjie","family":"Wu","sequence":"first","affiliation":[{"name":"Department of Cardiology, The First Affiliated Hospital of Wenzhou Medical University, Nanbaixiang, Wenzhou 325000, PR China"},{"name":"The Key Lab of Cardiovascular Disease, Science and Technology of Wenzhou, Wenzhou, PR China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parikshit S","family":"Sharma","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Rush University Medical Center, Chicago, IL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weijian","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The First Affiliated Hospital of Wenzhou Medical University, Nanbaixiang, Wenzhou 325000, PR China"},{"name":"The Key Lab of Cardiovascular Disease, Science and Technology of Wenzhou, Wenzhou, PR China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2020,12,28]]},"reference":[{"key":"2020122812095437400_euaa297-B1","doi-asserted-by":"crossref","first-page":"3115","DOI":"10.1001\/jama.288.24.3115","article-title":"Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial","volume":"288","author":"Wilkoff","year":"2002","journal-title":"JAMA"},{"key":"2020122812095437400_euaa297-B2","first-page":"234","article-title":"In memoriam. Tribute to Ake Senning, pioneering cardiovascular surgeon","volume":"27","author":"Cooley","year":"2000","journal-title":"Tex Heart Inst J"},{"key":"2020122812095437400_euaa297-B3","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1016\/j.hrthm.2014.12.031","article-title":"Electrical dyssynchrony induced by biventricular pacing: implications for patient selection and therapy improvement","volume":"12","author":"Ploux","year":"2015","journal-title":"Heart Rhythm"},{"key":"2020122812095437400_euaa297-B4","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1111\/j.1540-8159.1998.tb01096.x","article-title":"Permanent left ventricular pacing with transvenous leads inserted into the coronary veins","volume":"21","author":"Daubert","year":"1998","journal-title":"Pacing Clin Electrophysiol"},{"key":"2020122812095437400_euaa297-B5","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1136\/heartjnl-2018-313415","article-title":"Long-term outcomes of His bundle pacing in patients with heart failure with left bundle branch block","volume":"105","author":"Huang","year":"2019","journal-title":"Heart"},{"key":"2020122812095437400_euaa297-B6","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.hrthm.2017.10.039","article-title":"Permanent His bundle pacing: recommendations from a Multicenter His Bundle Pacing Collaborative Working Group for standardization of definitions, implant measurements, and follow-up","volume":"15","author":"Vijayaraman","year":"2018","journal-title":"Heart Rhythm"},{"key":"2020122812095437400_euaa297-B7","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1161\/01.CIR.101.8.869","article-title":"Permanent, direct His-bundle pacing: a novel approach to cardiac pacing in patients with normal His-Purkinje activation","volume":"101","author":"Deshmukh","year":"2000","journal-title":"Circulation"},{"key":"2020122812095437400_euaa297-B8","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1093\/europace\/euy281","article-title":"Pacing parameters and success rates of permanent His-bundle pacing in patients with narrow QRS: a single-centre experience","volume":"21","author":"Su","year":"2019","journal-title":"Europace"},{"key":"2020122812095437400_euaa297-B9","doi-asserted-by":"crossref","first-page":"1736.e1731","DOI":"10.1016\/j.cjca.2017.09.013","article-title":"A novel pacing strategy with low and stable output: pacing the left bundle branch immediately beyond the conduction block","volume":"33","author":"Huang","year":"2017","journal-title":"Can J Cardiol"},{"key":"2020122812095437400_euaa297-B10","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1016\/S0735-1097(03)00091-3","article-title":"Left ventricular septal and apex pacing for optimal pump function in canine hearts","volume":"41","author":"Peschar","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"2020122812095437400_euaa297-B11","doi-asserted-by":"crossref","first-page":"2256","DOI":"10.1111\/j.1540-8159.1998.tb01163.x","article-title":"Optimization of ventricular function by improving the activation sequence during ventricular pacing","volume":"21","author":"Prinzen","year":"1998","journal-title":"Pacing Clin Electrophysiol"},{"key":"2020122812095437400_euaa297-B12","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1161\/CIRCEP.113.001110","article-title":"Development of a technique for left ventricular endocardial pacing via puncture of the interventricular septum","volume":"7","author":"Betts","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2020122812095437400_euaa297-B13","doi-asserted-by":"crossref","first-page":"2118","DOI":"10.1093\/eurheartj\/ehv723","article-title":"ALternate Site Cardiac ResYNChronization (ALSYNC): a prospective and multicentre study of left ventricular endocardial pacing for cardiac resynchronization therapy","volume":"37","author":"Morgan","year":"2016","journal-title":"Eur Heart J"},{"key":"2020122812095437400_euaa297-B14","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1053\/eupc.2002.0253","article-title":"Testing a new mechanism for left interventricular septal pacing: the transseptal route; a feasibility and safety study","volume":"4","author":"Grosfeld","year":"2002","journal-title":"Europace"},{"key":"2020122812095437400_euaa297-B15","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1161\/CIRCEP.109.882910","article-title":"Left ventricular septal and left ventricular apical pacing chronically maintain cardiac contractile coordination, pump function and efficiency","volume":"2","author":"Mills","year":"2009","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2020122812095437400_euaa297-B16","doi-asserted-by":"crossref","first-page":"e003344","DOI":"10.1161\/CIRCEP.115.003344","article-title":"Feasibility and acute hemodynamic effect of left ventricular septal pacing by transvenous approach through the interventricular septum","volume":"9","author":"Mafi-Rad","year":"2016","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2020122812095437400_euaa297-B17","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.jacc.2019.11.040","article-title":"Short-term hemodynamic and electrophysiological effects of cardiac resynchronization by left ventricular septal pacing","volume":"75","author":"Salden","year":"2020","journal-title":"J Am Coll Cardiol"},{"key":"2020122812095437400_euaa297-B18","doi-asserted-by":"crossref","first-page":"1791","DOI":"10.1016\/j.hrthm.2019.06.016","article-title":"A beginner's guide to permanent left bundle branch pacing","volume":"16","author":"Huang","year":"2019","journal-title":"Heart Rhythm"},{"key":"2020122812095437400_euaa297-B19","author":"Wj"},{"key":"2020122812095437400_euaa297-B20","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/j.jelectrocard.2017.03.004","article-title":"The normal variants in the left bundle branch system","volume":"50","author":"Elizari","year":"2017","journal-title":"J Electrocardiol"},{"key":"2020122812095437400_euaa297-B21","author":"Huang","year":"2019"},{"key":"2020122812095437400_euaa297-B22","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1016\/j.jacep.2020.04.011","article-title":"Cardiac resynchronization therapy in patients with nonischemic cardiomyopathy using left bundle branch pacing","volume":"6","author":"Huang","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2020122812095437400_euaa297-B23","doi-asserted-by":"crossref","DOI":"10.1016\/j.cjca.2020.04.037","article-title":"Left bundle branch pacing for cardiac resynchronization therapy: non-randomized on treatment comparison with His bundle pacing and biventricular pacing","author":"Wu","year":"2020","journal-title":"Can J Cardiol"},{"key":"2020122812095437400_euaa297-B24","first-page":"399","article-title":"Long-term benefits and feasibility of permanent left bundle branch pacing in patients with left bundle branch block","volume":"23","author":"Wu","year":"2019","journal-title":"Chin J Cardiac Arrhyth"},{"key":"2020122812095437400_euaa297-B25","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1093\/europace\/euz031","article-title":"Peri-left bundle branch pacing in a patient with right ventricular pacing-induced cardiomyopathy and atrioventricular infra-Hisian block","volume":"21","author":"Wu","year":"2019","journal-title":"Europace"},{"key":"2020122812095437400_euaa297-B26","doi-asserted-by":"crossref","first-page":"2319","DOI":"10.1016\/j.jacc.2018.02.048","article-title":"Clinical outcomes of His bundle pacing compared to right ventricular pacing","volume":"71","author":"Abdelrahman","year":"2018","journal-title":"J Am Coll Cardiol"},{"key":"2020122812095437400_euaa297-B27","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1111\/jce.14377","article-title":"Electrophysiological characteristics and clinical values of left bundle branch current of injury in left bundle branch pacing","volume":"31","author":"Su","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2020122812095437400_euaa297-B28","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1016\/j.hrthm.2019.05.011","article-title":"Prospective evaluation of feasibility, electrophysiologic and echocardiographic characteristics of left bundle branch area pacing","volume":"16","author":"Vijayaraman","year":"2019","journal-title":"Heart Rhythm"},{"key":"2020122812095437400_euaa297-B29","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1016\/j.jacep.2015.09.012","article-title":"Electrophysiologic insights into site of atrioventricular block","volume":"1","author":"Vijayaraman","year":"2015","journal-title":"JACC Clin Electrophysiol"},{"key":"2020122812095437400_euaa297-B30","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1016\/j.ccep.2018.05.016","article-title":"Pacing treatment of atrial fibrillation patients with heart failure: His bundle pacing combined with atrioventricular node ablation","volume":"10","author":"Huang","year":"2018","journal-title":"Card Electrophysiol Clin"},{"key":"2020122812095437400_euaa297-B31","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.116.005309","article-title":"Benefits of permanent His bundle pacing combined with atrioventricular node ablation in atrial fibrillation patients with heart failure with both preserved and reduced left ventricular ejection fraction","volume":"6","author":"Huang","year":"2017","journal-title":"J Am Heart Assoc"},{"key":"2020122812095437400_euaa297-B32","doi-asserted-by":"crossref","first-page":"e014253","DOI":"10.1161\/JAHA.119.014253","article-title":"Feasibility and efficacy of His bundle pacing or left bundle pacing combined with atrioventricular node ablation in patients with persistent atrial fibrillation and implantable cardioverter-defibrillator therapy","volume":"8","author":"Wang","year":"2019","journal-title":"J Am Heart Assoc"},{"key":"2020122812095437400_euaa297-B33","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1093\/europace\/euy293","article-title":"Non-invasive electrocardiographic imaging of His-bundle and peri-left bundle pacing in left bundle branch block","volume":"21","author":"Chan","year":"2019","journal-title":"Europace"},{"key":"2020122812095437400_euaa297-B34","doi-asserted-by":"crossref","first-page":"1694","DOI":"10.1093\/europace\/euz188","article-title":"Feasibility and cardiac synchrony of permanent left bundle branch pacing through the interventricular septum","volume":"21","author":"Hou","year":"2019","journal-title":"Europace"},{"key":"2020122812095437400_euaa297-B35","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1111\/jce.13956","article-title":"The characteristics of the electrocardiogram and the intracardiac electrogram in left bundle branch pacing","volume":"30","author":"Chen","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2020122812095437400_euaa297-B36","doi-asserted-by":"crossref","first-page":"1472","DOI":"10.1111\/jce.14463","article-title":"Short-term and intermediate-term performance and safety of left bundle branch pacing","volume":"31","author":"Guo","year":"2020","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["EP Europace"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/europace\/article-pdf\/22\/Supplement_2\/ii10\/35204058\/euaa297.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/europace\/article-pdf\/22\/Supplement_2\/ii10\/35204058\/euaa297.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T17:52:24Z","timestamp":1697305944000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/22\/Supplement_2\/ii10\/6054247"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12]]},"references-count":36,"journal-issue":{"issue":"Supplement_2","published-online":{"date-parts":[[2020,12,28]]},"published-print":{"date-parts":[[2020,12,26]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/euaa297","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2020,12]]},"published":{"date-parts":[[2020,12]]}}}