{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T19:53:55Z","timestamp":1791402835870,"version":"4.3.3"},"reference-count":57,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2023,4,15]],"date-time":"2023-04-15T00:00:00Z","timestamp":1681516800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,4,15]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Conduction system pacing (CSP) has emerged as a more physiological alternative to right ventricular pacing and is also being used in selected cases for cardiac resynchronization therapy. His bundle pacing was first introduced over two decades ago and its use has risen over the last years with the advent of tools which have facilitated implantation. Left bundle branch area pacing is more recent but its adoption is growing fast due to a wider target area and excellent electrical parameters. Nevertheless, as with any intervention, proper technique is a prerequisite for safe and effective delivery of therapy. This document aims to standardize the procedure and to provide a framework for physicians who wish to start CSP implantation, or who wish to improve their technique. A synopsis is provided in this print edition of EP-Europace. The full document may be consulted online, and a \u2018Key Messages\u2019 App can be downloaded from the EHRA website.<\/jats:p>","DOI":"10.1093\/europace\/euad044","type":"journal-article","created":{"date-parts":[[2023,2,6]],"date-time":"2023-02-06T16:40:53Z","timestamp":1675701653000},"page":"1237-1248","source":"Crossref","is-referenced-by-count":131,"title":["EHRA clinical consensus statement on conduction system pacing implantation: executive summary. Endorsed by the Asia-Pacific Heart Rhythm Society (APHRS), Canadian Heart Rhythm Society (CHRS) and Latin-American Heart Rhythm Society (LAHRS)"],"prefix":"10.1093","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4393-5338","authenticated-orcid":false,"given":"Haran","family":"Burri","sequence":"first","affiliation":[{"name":"Cardiac Pacing Unit, University Hospital of Geneva , Geneva ,","place":["Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marek","family":"Jastrzebski","sequence":"additional","affiliation":[{"name":"First Department of Cardiology and Electrocardiology and Arterial Hypertension, Jagiellonian University , Krakow ,","place":["Poland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00d3scar","family":"Cano","sequence":"additional","affiliation":[{"name":"Hospital Universitario y Politecnico La Fe, ValenciamSpain and Centro de Investigaciones Biom\u00e9dicas en RED en Enfermedades Cardiovasculares (CIBERCV) , Madrid ,","place":["Spain"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karol","family":"\u010curila","sequence":"additional","affiliation":[{"name":"Cardiocenter, Third Faculty of Medicine, Charles University and University Hospital, Kralovske Vinohrady , Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"de Pooter","sequence":"additional","affiliation":[{"name":"Heart Centre, University Hospital Ghent , Ghent ,","place":["Belgium"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weijian","family":"Huang","sequence":"additional","affiliation":[{"name":"The First Affiliated Hospital of Wenzhou Medical University , Wenzhou ,","place":["China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carsten","family":"Israel","sequence":"additional","affiliation":[{"name":"Bethel-Clinic , Bielefeld ,","place":["Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacqueline","family":"Joza","sequence":"additional","affiliation":[{"name":"Department of Medicine, McGill University Health Center , Montreal ,","place":["Canada"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jorge","family":"Romero","sequence":"additional","affiliation":[{"name":"Brigham and Women's Hospital , Boston, Massachusetts ,","place":["United States of America"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"Vernooy","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center , Maastricht ,","place":["The Netherlands"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pugazhendhi","family":"Vijayaraman","sequence":"additional","affiliation":[{"name":"Geisinger Wyoming Valley Medical Center , Wilkes-Barre, PA ,","place":["United States of America"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zachary","family":"Whinnett","sequence":"additional","affiliation":[{"name":"National Heart and Lung institute, Imperial College London ,","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Zanon","sequence":"additional","affiliation":[{"name":"Arrhythmia and Electrophysiology Unit, Santa Maria della Misericordia General Hospital , Rovigo ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2023,4,15]]},"reference":[{"key":"2026080913404171200_euad044-B1","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1016\/j.hrthm.2021.04.015","article-title":"Contrast-enhanced image-guided lead deployment for left bundle branch pacing","volume":"18","author":"Liu","year":"2021","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2023.01.017","article-title":"Right bundle branch pacing: criteria, characteristics, and outcomes","author":"Jastrzebski","year":"2023","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B3","doi-asserted-by":"crossref","first-page":"4161","DOI":"10.1093\/eurheartj\/ehac445","article-title":"Left bundle branch area pacing outcomes: the multicentre European MELOS study","volume":"43","author":"Jastrzebski","year":"2022","journal-title":"Eur Heart J"},{"key":"2026080913404171200_euad044-B4","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1016\/j.hrthm.2022.01.018","article-title":"Electrophysiological characteristics of septal perforation during left bundle branch pacing","volume":"19","author":"Ponnusamy","year":"2022","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B5","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1016\/j.hrthm.2022.04.027","article-title":"Current of injury is an indicator of lead depth and performance during left bundle branch pacing lead implantation","volume":"19","author":"Shali","year":"2022","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B6","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1016\/j.jacep.2020.03.005","article-title":"Electrocardiographic analysis for his bundle pacing at implantation and follow-up","volume":"6","author":"Burri","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2026080913404171200_euad044-B7","doi-asserted-by":"crossref","first-page":"1857","DOI":"10.1093\/europace\/euz275","article-title":"Electrocardiographic characterization of non-selective his-bundle pacing: validation of novel diagnostic criteria","volume":"21","author":"Jastrzebski","year":"2019","journal-title":"Europace"},{"key":"2026080913404171200_euad044-B8","doi-asserted-by":"crossref","first-page":"1808","DOI":"10.1016\/j.hrthm.2019.06.001","article-title":"His bundle has a shorter chronaxie than does the adjacent ventricular myocardium: implications for pacemaker programming","volume":"16","author":"Jastrzebski","year":"2019","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B9","doi-asserted-by":"crossref","first-page":"e007052","DOI":"10.1161\/CIRCEP.118.007052","article-title":"Programmed his bundle pacing","volume":"12","author":"Jastrzebski","year":"2019","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026080913404171200_euad044-B10","doi-asserted-by":"crossref","first-page":"3010","DOI":"10.1111\/jce.15233","article-title":"Novel approach to diagnosis of his bundle capture using individualized left ventricular lateral wall activation time as reference","volume":"32","author":"Jastrz\u0119bski","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026080913404171200_euad044-B11","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1093\/europace\/euy281","article-title":"Pacing parameters and success rates of permanent his-bundle pacing in patients with narrow QRS: a single-centre experience","volume":"21","author":"Su","year":"2019","journal-title":"Europace"},{"key":"2026080913404171200_euad044-B12","doi-asserted-by":"crossref","first-page":"24","DOI":"10.15420\/aer.2016:34:2","article-title":"Electrophysiological testing for the investigation of bradycardias","volume":"6","author":"Katritsis","year":"2017","journal-title":"Arrhythm Electrophysiol Rev"},{"key":"2026080913404171200_euad044-B13","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1111\/pace.12571","article-title":"Acute his-bundle injury current during permanent his-bundle pacing predicts excellent pacing outcomes","volume":"38","author":"Vijayaraman","year":"2015","journal-title":"Pacing Clin Electrophysiol"},{"key":"2026080913404171200_euad044-B14","doi-asserted-by":"crossref","first-page":"e007415","DOI":"10.1161\/CIRCEP.119.007415","article-title":"Deep negative deflection in unipolar his-bundle electrogram as a predictor of excellent his-bundle pacing threshold postimplant","volume":"12","author":"Sato","year":"2019","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026080913404171200_euad044-B15","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1111\/jce.14834","article-title":"Nonselective versus selective his bundle pacing: an acute intrapatient speckle-tracking strain echocardiographic study","volume":"32","author":"Bednarek","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026080913404171200_euad044-B16","doi-asserted-by":"crossref","first-page":"1010","DOI":"10.1093\/europace\/eux120","article-title":"Comparison of the effects of selective and non-selective his bundle pacing on cardiac electrical and mechanical synchrony","volume":"20","author":"Zhang","year":"2018","journal-title":"Europace"},{"key":"2026080913404171200_euad044-B17","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1016\/j.hrthm.2019.11.016","article-title":"Both selective and nonselective his bundle, but not myocardial, pacing preserve ventricular electrical synchrony assessed by ultra-high-frequency ECG","volume":"17","author":"Curila","year":"2020","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B18","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1016\/j.jacep.2019.04.008","article-title":"Clinical outcomes of selective versus nonselective his bundle pacing","volume":"5","author":"Beer","year":"2019","journal-title":"JACC Clin Electrophysiol"},{"key":"2026080913404171200_euad044-B19","doi-asserted-by":"crossref","first-page":"e009261","DOI":"10.1161\/CIRCEP.120.009261","article-title":"Long-Term safety and feasibility of left bundle branch pacing in a large single-center study","volume":"14","author":"Su","year":"2021","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026080913404171200_euad044-B20","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1016\/j.jacep.2020.07.004","article-title":"Initial experience, safety, and feasibility of left bundle branch area pacing: A multicenter prospective study","volume":"6","author":"Padala","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2026080913404171200_euad044-B21","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1016\/j.jacep.2020.05.008","article-title":"Comparison of left bundle branch and his bundle pacing in bradycardia patients","volume":"6","author":"Hua","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2026080913404171200_euad044-B22","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1016\/j.hrthm.2019.05.011","article-title":"Prospective evaluation of feasibility and electrophysiologic and echocardiographic characteristics of left bundle branch area pacing","volume":"16","author":"Vijayaraman","year":"2019","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B23","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1111\/jce.14851","article-title":"Left bundle branch area pacing using stylet-driven pacing leads with a new delivery sheath: A comparison with lumen-less leads","volume":"32","author":"De Pooter","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026080913404171200_euad044-B24","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.jacep.2020.08.015","article-title":"Left bundle branch area pacing for cardiac resynchronization therapy: results from the international LBBAP collaborative study group","volume":"7","author":"Vijayaraman","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"key":"2026080913404171200_euad044-B25","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2022.01.018","article-title":"Electrophysiological characteristics of septal perforation during left bundle branch pacing","author":"Ponnusamy","year":"2022","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B26","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1111\/jce.15558","article-title":"Initial experience of left bundle branch area pacing using stylet-driven pacing leads: A multicenter study","volume":"33","author":"De Pooter","year":"2022","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026080913404171200_euad044-B27","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2022.06.003","article-title":"Predictors of loss of capture in left bundle branch pacing: a multicenter experience","volume":"19","author":"Tan","year":"2022","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B28","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1016\/j.hrcr.2020.05.010","article-title":"Aborted ST-elevation myocardial infarction-an unusual complication of left bundle branch pacing","volume":"6","author":"Ponnusamy","year":"2020","journal-title":"HeartRhythm Case Rep"},{"key":"2026080913404171200_euad044-B29","doi-asserted-by":"crossref","first-page":"ytab049","DOI":"10.1093\/ehjcr\/ytab049","article-title":"Visualization of a septal perforator branch vein and coronary sinus during left bundle pacing implant","volume":"5","author":"Molina-Lerma","year":"2021","journal-title":"Eur Heart J Case Rep"},{"key":"2026080913404171200_euad044-B30","doi-asserted-by":"crossref","first-page":"744079","DOI":"10.3389\/fcvm.2021.744079","article-title":"Case report: interventricular septal hematoma complicating left bundle branch pacing lead implantation","volume":"8","author":"Zheng","year":"2021","journal-title":"Front Cardiovasc Med"},{"key":"2026080913404171200_euad044-B31","doi-asserted-by":"crossref","first-page":"1464","DOI":"10.1111\/jce.15030","article-title":"Repositioning and extraction of stylet-driven pacing leads with extendable helix used for left bundle branch area pacing","volume":"32","author":"le Polain de Waroux","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026080913404171200_euad044-B32","doi-asserted-by":"crossref","first-page":"1550","DOI":"10.1111\/jce.15528","article-title":"Use of extendable helix leads for conduction system pacing: differences in lead handling and performance lead design impacts conduction system pacing","volume":"33","author":"Tan","year":"2022","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026080913404171200_euad044-B33","doi-asserted-by":"crossref","first-page":"645947","DOI":"10.3389\/fcvm.2021.645947","article-title":"Procedure-Related complications of left bundle branch pacing: A single-center experience","volume":"8","author":"Chen","year":"2021","journal-title":"Front Cardiovasc Med"},{"key":"2026080913404171200_euad044-B34","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1016\/j.hrcr.2020.06.008","article-title":"Late-onset interventricular septal perforation from left bundle branch pacing","volume":"6","author":"Ravi","year":"2020","journal-title":"HeartRhythm Case Rep"},{"key":"2026080913404171200_euad044-B35","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1016\/j.hrthm.2022.03.005","article-title":"Tricuspid regurgitation outcomes in left bundle branch area pacing and comparison with right ventricular septal pacing","volume":"19","author":"Li","year":"2022","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B36","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2022.10.027","article-title":"Distance between the lead-implanted site and tricuspid valve annulus in patients with left bundle branch pacing: effects on postoperative tricuspid regurgitation deterioration","volume":"20","author":"Hu","year":"2023","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B37","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.hrthm.2021.08.033","article-title":"Clinical outcomes of left bundle branch area pacing compared to right ventricular pacing: results from the geisinger-rush conduction system pacing registry","volume":"19","author":"Sharma","year":"2022","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B38","doi-asserted-by":"crossref","first-page":"2346","DOI":"10.1111\/jce.15155","article-title":"Late dislodgement of left bundle branch pacing lead and successful extraction","volume":"32","author":"Ponnusamy","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026080913404171200_euad044-B39","doi-asserted-by":"crossref","first-page":"e009677","DOI":"10.1161\/CIRCEP.120.009677","article-title":"Template beat: A novel marker for left bundle branch capture during physiological pacing","volume":"14","author":"Ponnusamy","year":"2021","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026080913404171200_euad044-B40","doi-asserted-by":"crossref","DOI":"10.1111\/jce.15597","article-title":"M-beat-A novel marker for selective left bundle branch capture","volume":"33","author":"Ponnusamy","year":"2022","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026080913404171200_euad044-B41","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1111\/jce.14377","article-title":"Electrophysiological characteristics and clinical values of left bundle branch current of injury in left bundle branch pacing","volume":"31","author":"Su","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026080913404171200_euad044-B42","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1093\/europace\/euab164","article-title":"The V6-V1 interpeak interval: a novel criterion for the diagnosis of left bundle branch capture","volume":"24","author":"Jastrz\u0119bski","year":"2022","journal-title":"Europace"},{"key":"2026080913404171200_euad044-B43","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1016\/j.hrthm.2021.02.021","article-title":"Physiology-based electrocardiographic criteria for left bundle branch capture","volume":"18","author":"Jastrz\u0119bski","year":"2021","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B44","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1111\/jce.14352","article-title":"Programmed deep septal stimulation: A novel maneuver for the diagnosis of left bundle branch capture during permanent pacing","volume":"31","author":"Jastrz\u0119bski","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026080913404171200_euad044-B45","first-page":"156","article-title":"Deep septal deployment of a thin, lumenless pacing lead: a translational cadaver simulation study","volume":"22","author":"Jastrzebski","year":"2020","journal-title":"Europace"},{"key":"2026080913404171200_euad044-B46","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1016\/j.hrthm.2021.04.025","article-title":"Left bundle branch pacing compared to left ventricular septal myocardial pacing increases interventricular dyssynchrony but accelerates left ventricular lateral wall depolarization","volume":"18","author":"Curila","year":"2021","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B47","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2021.787414","article-title":"Left ventricular myocardial septal pacing in close proximity to LBB does not prolong the duration of the left ventricular lateral wall depolarization compared to LBB pacing","volume":"8","author":"Curila","year":"2021","journal-title":"Front Cardiovasc Med"},{"key":"2026080913404171200_euad044-B48","doi-asserted-by":"crossref","DOI":"10.3390\/jcm10040822","article-title":"Comparing ventricular synchrony in left bundle branch and left ventricular septal pacing in pacemaker patients","volume":"10","author":"Heckman","year":"2021","journal-title":"J Clin Med"},{"key":"2026080913404171200_euad044-B49","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1093\/europace\/euac223","article-title":"Left bundle branch area pacing in patients with baseline narrow, left, or right bundle branch block QRS patterns: insights into electrocardiographic and echocardiographic features","volume":"25","author":"Mirolo","year":"2023","journal-title":"Europace"},{"key":"2026080913404171200_euad044-B50","doi-asserted-by":"crossref","first-page":"ii10","DOI":"10.1093\/europace\/euaa297","article-title":"Novel left ventricular cardiac synchronization: left ventricular septal pacing or left bundle branch pacing?","volume":"22","author":"Wu","year":"2020","journal-title":"Europace"},{"key":"2026080913404171200_euad044-B51","doi-asserted-by":"crossref","first-page":"1694","DOI":"10.1093\/europace\/euz188","article-title":"Feasibility and cardiac synchrony of permanent left bundle branch pacing through the interventricular septum","volume":"21","author":"Hou","year":"2019","journal-title":"Europace"},{"key":"2026080913404171200_euad044-B52","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1016\/j.hrthm.2019.06.005","article-title":"Extraction of the permanent his bundle pacing lead: safety outcomes and feasibility of reimplantation","volume":"16","author":"Vijayaraman","year":"2019","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B53","doi-asserted-by":"crossref","first-page":"1464","DOI":"10.1111\/pace.14227","article-title":"Extraction of a very old his bundle pacing lead: A safe and effective procedure?","volume":"44","author":"Migliore","year":"2021","journal-title":"Pacing Clin Electrophysiol"},{"key":"2026080913404171200_euad044-B54","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1016\/j.hrthm.2020.12.031","article-title":"Intermediate-term performance and safety of his-bundle pacing leads: A single-center experience","volume":"18","author":"Teigeler","year":"2021","journal-title":"Heart Rhythm"},{"key":"2026080913404171200_euad044-B55","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1093\/europace\/euaa344","article-title":"Cryoablation vs. Radiofrequency ablation of the atrioventricular node in patients with his-bundle pacing","volume":"23","author":"Zweerink","year":"2021","journal-title":"Europace"},{"key":"2026080913404171200_euad044-B56","doi-asserted-by":"crossref","first-page":"iv10","DOI":"10.1093\/europace\/eux263","article-title":"Atrioventricular node ablation and his bundle pacing","volume":"19","author":"Vijayaraman","year":"2017","journal-title":"Europace"},{"key":"2026080913404171200_euad044-B57","doi-asserted-by":"crossref","first-page":"ii19","DOI":"10.1093\/europace\/euaa306","article-title":"Long-term performance and risk factors analysis after permanent his-bundle pacing and atrioventricular node ablation in patients with atrial fibrillation and heart failure","volume":"22","author":"Su","year":"2020","journal-title":"Europace"}],"container-title":["Europace"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/europace\/article-pdf\/25\/4\/1237\/60920788\/euad044.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/europace\/article-pdf\/25\/4\/1237\/60920788\/euad044.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,9]],"date-time":"2026-08-09T17:40:52Z","timestamp":1786297252000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/25\/4\/1237\/7121194"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,15]]},"references-count":57,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,4,15]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/euad044","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2023,4,28]]},"published":{"date-parts":[[2023,4,15]]}}}