{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T00:08:23Z","timestamp":1789344503049,"version":"build-2803163510"},"reference-count":49,"publisher":"Oxford University Press (OUP)","issue":"5","license":[{"start":{"date-parts":[[2023,5,1]],"date-time":"2023-05-01T00:00:00Z","timestamp":1682899200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,5,19]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Aims<\/jats:title>\n                  <jats:p>Pulmonary vein (PV) antrum isolation proved to be effective for treating persistent atrial fibrillation (PeAF). We sought to investigate the results of a personalized approach aimed at adapting the ablation index (AI) to the local left atrial wall thickness (LAWT) in a cohort of consecutive patients with PeAF.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods and results<\/jats:title>\n                  <jats:p>Consecutive patients referred for PeAF first ablation were prospectively enrolled. The LAWT three-dimensional maps were obtained from pre-procedure multidetector computed tomography and integrated into the navigation system. Ablation index was titrated according to the local LAWT, and the ablation line was personalized to avoid the thickest regions while encircling the PV antrum. A total of 121 patients (69.4% male, age 64.5 \u00b1 9.5 years) were included. Procedure time was 57\u2005min (IQR 50\u201367), fluoroscopy time was 43\u2005s (IQR 20\u201371), and radiofrequency (RF) time was 16.5\u2005min (IQR 14.3\u201318.4). The median AI tailored to the local LAWT was 387 (IQR 360\u2013410) for the anterior wall and 335 (IQR 300\u2013375) for the posterior wall. First-pass PV antrum isolation was obtained in 103 (85%) of the right PVs and 103 (85%) of the left PVs. Median LAWT values were higher for PVs without first-pass isolation as compared to the whole cohort (P = 0.02 for left PVs and P = 0.03 for right PVs). Recurrence-free survival was 79% at 12 month follow-up.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>In this prospective study, LAWT-guided PV antrum isolation for PeAF was effective and efficient, requiring low procedure, fluoroscopy, and RF time. A randomized trial comparing the LAWT-guided ablation with the standard of practice is in progress (ClinicalTrials.gov, NCT05396534).<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/europace\/euad118","type":"journal-article","created":{"date-parts":[[2023,5,1]],"date-time":"2023-05-01T14:14:55Z","timestamp":1682950495000},"source":"Crossref","is-referenced-by-count":32,"title":["Personalized pulmonary vein antrum isolation guided by left atrial wall thickness for persistent atrial fibrillation"],"prefix":"10.1093","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7128-9911","authenticated-orcid":false,"given":"Giulio","family":"Falasconi","sequence":"first","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"},{"name":"Campus Cl\u00ednic, University of Barcelona, C\/Villarroel 170 , 08024 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diego","family":"Penela","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1394-6260","authenticated-orcid":false,"given":"David","family":"Soto-Iglesias","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0306-7764","authenticated-orcid":false,"given":"Pietro","family":"Francia","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"},{"name":"Cardiology, Department of Clinical and Molecular Medicine, St. Andrea Hospital, Sapienza University, Via di Grottarossa 1035 , 00189 Rome , Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheryl","family":"Teres","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9475-1507","authenticated-orcid":false,"given":"Andrea","family":"Saglietto","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"},{"name":"Department of Medical Sciences, University of Turin, Corso Dogliotti 14 , 10126 Turin , Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9187-1773","authenticated-orcid":false,"given":"Beatriz","family":"Jauregui","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8317-561X","authenticated-orcid":false,"given":"Daniel","family":"Viveros","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"},{"name":"Campus Cl\u00ednic, University of Barcelona, C\/Villarroel 170 , 08024 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aldo","family":"Bellido","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0318-5349","authenticated-orcid":false,"given":"Jose","family":"Alderete","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"},{"name":"Campus Cl\u00ednic, University of Barcelona, C\/Villarroel 170 , 08024 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia","family":"Meca-Santamaria","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6157-058X","authenticated-orcid":false,"given":"Paula","family":"Franco","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlo","family":"Gaspardone","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7792-0890","authenticated-orcid":false,"given":"Rodolfo","family":"San Antonio","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3524-6612","authenticated-orcid":false,"given":"Marina","family":"Huguet","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5125-6132","authenticated-orcid":false,"given":"\u00d3scar","family":"C\u00e1mara","sequence":"additional","affiliation":[{"name":"Department of Information and Communication Technologies, Pompeu Fabra University, C\/T\u00e0nger 122-140 , 08018 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8043-6055","authenticated-orcid":false,"given":"Jos\u00e9-Tom\u00e1s","family":"Ortiz-P\u00e9rez","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9927-1190","authenticated-orcid":false,"given":"Julio","family":"Mart\u00ed-Almor","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5418-383X","authenticated-orcid":false,"given":"Antonio","family":"Berruezo","sequence":"additional","affiliation":[{"name":"Arrhythmia Department, Heart Institute, Teknon Medical Centre, C\/Vilana 12 , 08022 Barcelona , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2023,5,1]]},"reference":[{"key":"2023053015323050600_euad118-B1","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1093\/europace\/euac237","article-title":"Global burden of atrial fibrillation\/atrial flutter and its attributable risk factors from 1990 to 2019","volume":"25","author":"Dong","year":"2023","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B2","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1093\/europace\/euaa279","article-title":"Dynamic risk assessment to improve quality of care in patients with atrial fibrillation: the 7th AFNET\/EHRA consensus conference","volume":"23","author":"Fabritz","year":"2021","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B3","doi-asserted-by":"crossref","first-page":"2004","DOI":"10.1093\/europace\/euac136","article-title":"The challenge of managing multimorbid atrial fibrillation: a pan-European European heart rhythm association (EHRA) member survey of current management practices and clinical priorities","volume":"24","author":"Lee","year":"2022","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B4","doi-asserted-by":"crossref","first-page":"1903","DOI":"10.1093\/europace\/euab113","article-title":"Prognostic markers of all-cause mortality in patients with atrial fibrillation: data from the prospective long-term registry of the German atrial fibrillation NETwork (AFNET)","volume":"23","author":"Nabauer","year":"2021","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B5","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1093\/europace\/euaa253","article-title":"Quality indicators for the care and outcomes of adults with atrial fibrillation","volume":"23","author":"Arbelo","year":"2021","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B6","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1093\/europace\/euaa415","article-title":"Relationship between procedural volume and complication rates for catheter ablation of atrial fibrillation: a systematic review and meta-analysis","volume":"23","author":"Tonchev","year":"2021","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B7","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1093\/europace\/euac236","article-title":"Patient selection, peri-procedural management, and ablation techniques for catheter ablation of atrial fibrillation: an EHRA survey","volume":"25","author":"Iliodromitis","year":"2022","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B8","doi-asserted-by":"crossref","first-page":"1751","DOI":"10.1093\/europace\/euab213","article-title":"Long-term outcome of catheter ablation for atrial fibrillation in patients with severe left atrial enlargement and reduced left ventricular ejection fraction","volume":"23","author":"Demarchi","year":"2021","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B9","doi-asserted-by":"crossref","first-page":"e275","DOI":"10.1016\/j.hrthm.2017.05.012","article-title":"2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"14","author":"Calkins","year":"2017","journal-title":"Heart Rhythm"},{"key":"2023053015323050600_euad118-B10","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1016\/j.hrthm.2017.01.003","article-title":"Revisiting pulmonary vein isolation alone for persistent atrial fibrillation: A systematic review and meta-analysis","volume":"14","author":"Voskoboinik","year":"2017","journal-title":"Heart Rhythm"},{"key":"2023053015323050600_euad118-B11","doi-asserted-by":"crossref","first-page":"1812","DOI":"10.1056\/NEJMoa1408288","article-title":"Approaches to catheter ablation for persistent atrial fibrillation","volume":"372","author":"Verma","year":"2015","journal-title":"N Engl J Med"},{"key":"2023053015323050600_euad118-B12","doi-asserted-by":"crossref","first-page":"2296","DOI":"10.1001\/jama.2022.8831","article-title":"Effect of MRI-guided fibrosis ablation vs conventional catheter ablation on atrial arrhythmia recurrence in patients with persistent atrial fibrillation: the DECAAF II randomized clinical trial","volume":"327","author":"Marrouche","year":"2022","journal-title":"JAMA"},{"key":"2023053015323050600_euad118-B13","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1093\/europace\/euab279","article-title":"Radiofrequency ablation to achieve durable pulmonary vein isolation","volume":"24","author":"Mulder","year":"2022","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B14","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.118.006576","article-title":"Use of ablation Index-guided ablation results in high rates of durable pulmonary vein isolation and freedom from arrhythmia in persistent atrial fibrillation patients: the PRAISE study results","volume":"11","author":"Hussein","year":"2018","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2023053015323050600_euad118-B15","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1016\/j.hroo.2021.10.012","article-title":"Continuous and discontinuous radiofrequency energy delivery on the atrial free wall: lesion transmurality, width, and biophysical characteristics","volume":"2","author":"Friedman","year":"2021","journal-title":"Heart Rhythm O2"},{"key":"2023053015323050600_euad118-B16","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1016\/j.jacep.2020.04.024","article-title":"Persistent atrial fibrillation ablation with contact force-sensing catheter: the prospective multicenter PRECEPT trial","volume":"6","author":"Mansour","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2023053015323050600_euad118-B17","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.jacep.2017.06.023","article-title":"Evaluation of a strategy aiming to enclose the pulmonary veins with contiguous and optimized radiofrequency lesions in paroxysmal atrial fibrillation: A pilot study","volume":"4","author":"Taghji","year":"2018","journal-title":"JACC Clin Electrophysiol"},{"key":"2023053015323050600_euad118-B18","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1093\/europace\/euab216","article-title":"Personalized paroxysmal atrial fibrillation ablation by tailoring ablation index to the left atrial wall thickness: the \u2018ablate by-LAW\u2019 single-centre study-a pilot study","volume":"24","author":"Teres","year":"2022","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B19","first-page":"373","article-title":"ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): the task force for the diagnosis and management of atrial fibrillation of the European society of cardiology (ESC) developed with the special contribution of the European heart rhythm association (EHRA) of the ESC","volume":"2021","author":"Hindricks","year":"2020","journal-title":"Eur Heart J"},{"key":"2023053015323050600_euad118-B20","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1111\/pace.14222","article-title":"Left atrial wall thickness of the pulmonary vein reconnection sites during atrial fibrillation redo procedures","volume":"44","author":"Teres","year":"2021","journal-title":"Pacing Clin Electrophysiol"},{"key":"2023053015323050600_euad118-B21","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-023-01472-5","article-title":"Reproducibility analysis of the computerized tomography angiography-derived left atrial wall thickness maps","author":"Valles-Colomer","year":"2023","journal-title":"J Interv Card Electrophysiol"},{"key":"2023053015323050600_euad118-B22","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1007\/s10840-022-01302-0","article-title":"Relationship between the posterior atrial wall and the esophagus: esophageal position and temperature measurement during atrial fibrillation ablation (AWESOME-AF). A randomized controlled trial","volume":"65","author":"Teres","year":"2022","journal-title":"J Interv Card Electrophysiol"},{"key":"2023053015323050600_euad118-B23","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1016\/j.jacep.2019.06.011","article-title":"High-frequency, low tidal volume ventilation to improve catheter stability during atrial fibrillation ablation","volume":"5","author":"Gabriels","year":"2019","journal-title":"JACC Clin Electrophysiol"},{"key":"2023053015323050600_euad118-B24","doi-asserted-by":"crossref","first-page":"2039","DOI":"10.1093\/europace\/euab154","article-title":"Worldwide sedation strategies for atrial fibrillation ablation: current status and evolution over the last decade","volume":"23","author":"Garcia","year":"2021","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B25","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1007\/s10840-021-01086-9","article-title":"A standardized stepwise zero-fluoroscopy approach with transesophageal echocardiography guidance for atrial fibrillation ablation","volume":"64","author":"Falasconi","year":"2022","journal-title":"J Interv Card Electrophysiol"},{"key":"2023053015323050600_euad118-B26","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.hrthm.2016.12.008","article-title":"Contact-force guided single-catheter approach for pulmonary vein isolation: feasibility, outcomes, and cost-effectiveness","volume":"14","author":"Pambrun","year":"2017","journal-title":"Heart Rhythm"},{"key":"2023053015323050600_euad118-B27","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1111\/j.1540-8167.2008.01182.x","article-title":"The important role of pulmonary vein carina ablation as an adjunct to circumferential pulmonary vein isolation","volume":"19","author":"Udyavar","year":"2008","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2023053015323050600_euad118-B28","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1093\/europace\/eum191","article-title":"Outcome parameters for trials in atrial fibrillation: recommendations from a consensus conference organized by the German atrial fibrillation competence NETwork and the European Heart Rhythm Association","volume":"9","author":"Kirchhof","year":"2007","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B29","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euab257","article-title":"Atrial fibrillation progression and the importance of early treatment for improving clinical outcomes","volume":"24","author":"Gunawardene","year":"2022","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B30","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.116.004867","article-title":"Determinants of acute and late pulmonary vein reconnection in contact force-guided pulmonary vein isolation: identifying the weakest link in the ablation chain","volume":"10","author":"El Haddad","year":"2017","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2023053015323050600_euad118-B31","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1093\/europace\/euv073","article-title":"Three-dimensional atrial wall thickness maps to inform catheter ablation procedures for atrial fibrillation","volume":"18","author":"Bishop","year":"2016","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B32","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1093\/eurheartj\/ehm606","article-title":"The architecture of the left lateral atrial wall: a particular anatomic region with implications for ablation of atrial fibrillation","volume":"29","author":"Cabrera","year":"2008","journal-title":"Eur Heart J"},{"key":"2023053015323050600_euad118-B33","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1016\/j.jacep.2022.06.007","article-title":"Composite Index tagging for PVI in paroxysmal AF: a prospective, multicenter postapproval study","volume":"8","author":"Di Biase","year":"2022","journal-title":"JACC Clin Electrophysiol"},{"key":"2023053015323050600_euad118-B34","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1093\/eurheartj\/ehm027","article-title":"Pre-procedural predictors of atrial fibrillation recurrence after circumferential pulmonary vein ablation","volume":"28","author":"Berruezo","year":"2007","journal-title":"Eur Heart J"},{"key":"2023053015323050600_euad118-B35","doi-asserted-by":"crossref","first-page":"1984","DOI":"10.1016\/j.ijcard.2012.05.008","article-title":"Which are the most reliable predictors of recurrence of atrial fibrillation after transcatheter ablation?: a meta-analysis","volume":"167","author":"D'Ascenzo","year":"2013","journal-title":"Int J Cardiol"},{"key":"2023053015323050600_euad118-B36","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1093\/europace\/euq434","article-title":"Predictors of recurrence following radiofrequency ablation for persistent atrial fibrillation","volume":"13","author":"McCready","year":"2011","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B37","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1016\/j.hrthm.2015.12.029","article-title":"Influence of underlying substrate on atrial tachyarrhythmias after pulmonary vein isolation","volume":"13","author":"Masuda","year":"2016","journal-title":"Heart Rhythm"},{"key":"2023053015323050600_euad118-B38","doi-asserted-by":"crossref","DOI":"10.1056\/EVIDoa2200141","article-title":"Low-voltage myocardium-guided ablation trial of persistent atrial fibrillation","volume":"1","author":"Huo","year":"2022","journal-title":"NEJM Evidence"},{"key":"2023053015323050600_euad118-B39","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.115.002962","article-title":"Ablation of persistent atrial fibrillation targeting low-voltage areas with selective activation characteristics","volume":"9","author":"Jadidi","year":"2016","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2023053015323050600_euad118-B40","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1111\/jce.12660","article-title":"Relation between left atrial wall thickness in patients with atrial fibrillation and intracardiac electrogram characteristics and ATP-provoked dormant pulmonary vein conduction","volume":"26","author":"Takahashi","year":"2015","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2023053015323050600_euad118-B41","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1007\/s10840-006-9052-2","article-title":"Variation in left atrial transmural wall thickness at sites commonly targeted for ablation of atrial fibrillation","volume":"17","author":"Hall","year":"2006","journal-title":"J Interv Card Electrophysiol"},{"key":"2023053015323050600_euad118-B42","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.ijcard.2009.10.032","article-title":"Left atrial wall thickness in paroxysmal atrial fibrillation by multislice-CT is initial marker of structural remodeling and predictor of transition from paroxysmal to chronic form","volume":"148","author":"Nakamura","year":"2011","journal-title":"Int J Cardiol"},{"key":"2023053015323050600_euad118-B43","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1111\/jce.13065","article-title":"Effect of left atrial wall thickness on radiofrequency ablation success","volume":"27","author":"Inoue","year":"2016","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2023053015323050600_euad118-B44","article-title":"Impact of local left atrial wall thickness on the incidence of acute pulmonary vein reconnection after ablation index-guided atrial fibrillation ablation","volume":"29","author":"Mulder","year":"2020","journal-title":"Int J Cardiol Heart Vasc"},{"key":"2023053015323050600_euad118-B45","doi-asserted-by":"crossref","first-page":"1899","DOI":"10.1093\/europace\/euac098","article-title":"Evidence-based insights on ideal blanking period duration following atrial fibrillation catheter ablation","volume":"24","author":"Saglietto","year":"2022","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B46","doi-asserted-by":"crossref","first-page":"1684","DOI":"10.1093\/europace\/euac131","article-title":"The blanking period after atrial fibrillation ablation: an European Heart Rhythm Association survey on contemporary definition and management","volume":"24","author":"Bordignon","year":"2022","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B47","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1093\/europace\/euac144","article-title":"Searching for atrial fibrillation: looking harder, looking longer, and in increasingly sophisticated ways. An EHRA position paper","volume":"25","author":"Kalarus","year":"2023","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B48","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1093\/europace\/euac038","article-title":"How to use digital devices to detect and manage arrhythmias: an EHRA practical guide","volume":"24","author":"Svennberg","year":"2022","journal-title":"Europace"},{"key":"2023053015323050600_euad118-B49","doi-asserted-by":"crossref","first-page":"1106","DOI":"10.1093\/europace\/euab064","article-title":"Current perspectives on wearable rhythm recordings for clinical decision-making: the wEHRAbles 2 survey","volume":"23","author":"Manninger","year":"2021","journal-title":"Europace"}],"container-title":["Europace"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/europace\/article-pdf\/25\/5\/euad118\/50487577\/euad118.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/europace\/article-pdf\/25\/5\/euad118\/50487577\/euad118.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,30]],"date-time":"2023-05-30T15:33:23Z","timestamp":1685460803000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/doi\/10.1093\/europace\/euad118\/7147533"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,1]]},"references-count":49,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,5,19]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/euad118","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2023,5]]},"published":{"date-parts":[[2023,5,1]]},"article-number":"euad118"}}