{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T18:07:53Z","timestamp":1791828473213,"version":"4.3.4"},"reference-count":26,"publisher":"Oxford University Press (OUP)","issue":"9","license":[{"start":{"date-parts":[[2023,8,12]],"date-time":"2023-08-12T00:00:00Z","timestamp":1691798400000},"content-version":"vor","delay-in-days":10,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,8,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aims<\/jats:title>\n                    <jats:p>Cardiac implantable electronic devices (CIED) are important tools for managing arrhythmias, improving hemodynamics, and preventing sudden cardiac death. Device-related infections (DRI) remain a significant complication of CIED and are associated with major adverse outcomes. We aimed to assess the trend in CIED implantations, and the burden and morbidity associated with DRI.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and results<\/jats:title>\n                    <jats:p>The 2011\u20132018 National Inpatient Sample database was searched for admissions for CIED implantation and DRI. A total of 1 604 173 admissions for CIED implantations and 71 007 (4.4%) admissions for DRI were reported. There was no significant change in annual admission rates for DRI (3.96\u20134.59%, P value for trend = 0.98). Those with DRI were more likely to be male (69.3 vs. 57%, P &amp;lt; 0.001) and have a Charlson comorbidity index score \u22653 (46.6 vs. 36.8%, P &amp;lt; 0.001). The prevalence of congestive heart failure (CHF) increased in those admitted with DRI over the observation period. Pulmonary embolism, deep vein thrombosis, and post-procedural hematoma were the most common complications in those with DRI (4.1, 3.6, and 2.90%, respectively). Annual in-hospital mortality for those with DRI ranged from 3.9 to 5.8% (mean 4.4%, P value for trend = 0.07). Multivariate analysis identified CHF [odds ratio (OR) = 1.67; 95% confidence interval (CI) = 1.35\u20132.07], end-stage renal disease (OR = 1.90; 95% CI = 1.46\u20132.48), coagulopathy (OR = 2.94; 95% CI = 2.40\u20133.61), and malnutrition (OR = 2.50; 95% CI = 1.99\u20133.15) as the predictors of in-hospital mortality for patients admitted with DRI.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Device-related infection is relatively common and continues to be associated with high morbidity and mortality. The prevalence of DRI has not changed significantly despite technical and technological advances in cardiac devices and their implantation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/europace\/euad208","type":"journal-article","created":{"date-parts":[[2023,8,10]],"date-time":"2023-08-10T17:01:03Z","timestamp":1691686863000},"source":"Crossref","is-referenced-by-count":30,"title":["Cardiac implantable electronic device implantation and device-related infection"],"prefix":"10.1093","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1245-9420","authenticated-orcid":false,"given":"Vivek","family":"Modi","sequence":"first","affiliation":[{"name":"Department of Cardiology, St. Luke\u2019s University Health Network, Heart and Vascular Center , 801 Ostrum Street, Bethlehem, PA 18015 , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7884-1692","authenticated-orcid":false,"given":"Kashyap","family":"Shah","sequence":"additional","affiliation":[{"name":"Department of Cardiology, St. Luke\u2019s University Health Network, Heart and Vascular Center , 801 Ostrum Street, Bethlehem, PA 18015 , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8361-0036","authenticated-orcid":false,"given":"Bruce","family":"Ferraro","sequence":"additional","affiliation":[{"name":"Department of Cardiology, St. Luke\u2019s University Health Network, Heart and Vascular Center , 801 Ostrum Street, Bethlehem, PA 18015 , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leyla","family":"Gasimli-Gamache","sequence":"additional","affiliation":[{"name":"Department of Cardiology, St. Luke\u2019s University Health Network, Heart and Vascular Center , 801 Ostrum Street, Bethlehem, PA 18015 , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3242-0539","authenticated-orcid":false,"given":"Sudip","family":"Nanda","sequence":"additional","affiliation":[{"name":"Department of Cardiology, St. Luke\u2019s University Health Network, Heart and Vascular Center , 801 Ostrum Street, Bethlehem, PA 18015 , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2955-7959","authenticated-orcid":false,"given":"Steven","family":"Stevens","sequence":"additional","affiliation":[{"name":"Department of Cardiology, St. Luke\u2019s University Health Network, Heart and Vascular Center , 801 Ostrum Street, Bethlehem, PA 18015 , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0447-2542","authenticated-orcid":false,"given":"Jamshid","family":"Shirani","sequence":"additional","affiliation":[{"name":"Department of Cardiology, St. Luke\u2019s University Health Network, Heart and Vascular Center , 801 Ostrum Street, Bethlehem, PA 18015 , USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2023,8,11]]},"reference":[{"key":"2023081210454455000_euad208-B1","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1111\/j.1540-8159.2009.02670.x","article-title":"Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1993\u20132006: implantation trends and patient profiles for pacemakers and ICDs","volume":"33","author":"Kurtz","year":"2010","journal-title":"Pacing Clin Electrophysiol"},{"key":"2023081210454455000_euad208-B2","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1016\/j.jacc.2012.07.017","article-title":"Trends in permanent pacemaker implantation in the United States from 1993 to 2009","volume":"60","author":"Greenspon","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"2023081210454455000_euad208-B3","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1111\/j.1540-8159.2011.03150.x","article-title":"The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009\u2014a World Society of Arrhythmia\u2019s Project: 2009 survey cardiac pacemakers and ICDS","volume":"34","author":"Mond","year":"2011","journal-title":"Pacing Clin Electrophysiol"},{"key":"2023081210454455000_euad208-B4","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1001\/jama.295.7.809","article-title":"Implantable cardioverter-defibrillators: expanding indications and technologies","volume":"295","author":"Goldberger","year":"2006","journal-title":"JAMA"},{"key":"2023081210454455000_euad208-B5","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.ijcard.2018.01.039","article-title":"Cardiac resynchronization therapy: how did consensus guidelines from Europe and the United States evolve in the last 15 years?","volume":"261","author":"Boriani","year":"2018","journal-title":"Int J Cardiol"},{"key":"2023081210454455000_euad208-B6","doi-asserted-by":"crossref","first-page":"e503","DOI":"10.1016\/j.hrthm.2017.09.001","article-title":"2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction","volume":"14","author":"Kusumoto","year":"2017","journal-title":"Heart Rhythm"},{"key":"2023081210454455000_euad208-B7","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1016\/j.jacc.2011.04.033","article-title":"16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States","volume":"58","author":"Greenspon","year":"2011","journal-title":"J Am Coll Cardiol"},{"key":"2023081210454455000_euad208-B8","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1016\/j.hrthm.2017.03.019","article-title":"Cardiac implantable electronic device infections: who is at greatest risk?","volume":"14","author":"Joy","year":"2017","journal-title":"Heart Rhythm"},{"key":"2023081210454455000_euad208-B9","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1093\/europace\/euz246","article-title":"European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections\u2014endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"22","author":"Blomstr\u00f6m-Lundqvist","year":"2020","journal-title":"Europace"},{"key":"2023081210454455000_euad208-B10","doi-asserted-by":"crossref","first-page":"1862","DOI":"10.1093\/eurheartj\/ehz316","article-title":"Incidence of device-related infection in 97 750 patients: clinical data from the complete Danish device-cohort (1982\u20132018)","volume":"40","author":"Olsen","year":"2019","journal-title":"Eur Heart J"},{"key":"2023081210454455000_euad208-B11","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.jacc.2008.02.032","article-title":"ACC\/AHA\/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities","volume":"51","author":"Epstein","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"2023081210454455000_euad208-B12"},{"key":"2023081210454455000_euad208-B13","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1016\/j.hrthm.2020.02.012","article-title":"Epidemiology of cardiac implantable electronic device infections in the United States: a population-based cohort study","volume":"17","author":"Rennert-May","year":"2020","journal-title":"Heart Rhythm"},{"key":"2023081210454455000_euad208-B14","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1056\/NEJMoa1511643","article-title":"A leadless intracardiac transcatheter pacing system","volume":"374","author":"Reynolds","year":"2016","journal-title":"N Engl J Med"},{"key":"2023081210454455000_euad208-B15","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.jacep.2021.06.006","article-title":"Trends in cardiovascular implantable electronic device insertion between 1988 and 2018 in Olmsted County","volume":"8","author":"Vaidya","year":"2022","journal-title":"JACC Clin Electrophysiol"},{"key":"2023081210454455000_euad208-B16","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1016\/j.jacc.2006.05.016","article-title":"Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003","volume":"48","author":"Voigt","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"2023081210454455000_euad208-B17","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.1016\/j.jacep.2019.06.016","article-title":"Trends of cardiovascular implantable electronic device infection in 3 decades","volume":"5","author":"Dai","year":"2019","journal-title":"JACC Clin Electrophysiol"},{"key":"2023081210454455000_euad208-B18","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1111\/j.1540-8159.2009.02569.x","article-title":"Continued rise in rates of cardiovascular implantable electronic device infections in the United States: temporal trends and causative insights","volume":"33","author":"Voigt","year":"2010","journal-title":"Pacing Clin Electrophysiol"},{"key":"2023081210454455000_euad208-B19","doi-asserted-by":"crossref","first-page":"1270","DOI":"10.1093\/europace\/euz137","article-title":"Clinical practice and implementation of guidelines for the prevention, diagnosis and management of cardiac implantable electronic device infections: results of a worldwide survey under the auspices of the European Heart Rhythm Association","volume":"21","author":"Traykov","year":"2019","journal-title":"Europace"},{"key":"2023081210454455000_euad208-B20","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1046\/j.1460-9592.2002.t01-1-00804.x","article-title":"Clinical study of the laser sheath for lead extraction: the total experience in the United States","volume":"25","author":"Byrd","year":"2002","journal-title":"Pacing Clin Electrophysiol"},{"key":"2023081210454455000_euad208-B21","doi-asserted-by":"crossref","first-page":"1821","DOI":"10.1001\/archinternmed.2011.441","article-title":"Mortality and cost associated with cardiovascular implantable electronic device infections","volume":"171","author":"Sohail","year":"2011","journal-title":"Arch Intern Med"},{"key":"2023081210454455000_euad208-B22","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1111\/pace.12518","article-title":"Increased long-term mortality in patients with cardiovascular implantable electronic device infections: long-term mortality with CIED infections","volume":"38","author":"Rizwan Sohail","year":"2015","journal-title":"Pacing Clin Electrophysiol"},{"key":"2023081210454455000_euad208-B23","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.1016\/j.amjcard.2012.01.360","article-title":"Effect of early diagnosis and treatment with percutaneous lead extraction on survival in patients with cardiac device infections","volume":"109","author":"Viganego","year":"2012","journal-title":"Am J Cardiol"},{"key":"2023081210454455000_euad208-B24","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1016\/j.amjcard.2012.11.052","article-title":"Predictors of mortality in patients with cardiovascular implantable electronic device infections","volume":"111","author":"Habib","year":"2013","journal-title":"Am J Cardiol"},{"key":"2023081210454455000_euad208-B25","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1111\/pace.13009","article-title":"Cardiac implantable electronic device-related infection and extraction trends in the U.S.: lead infection and extraction trends in the U.S","volume":"40","author":"Sridhar","year":"2017","journal-title":"Pacing Clin Electrophysiol"},{"key":"2023081210454455000_euad208-B26","doi-asserted-by":"crossref","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab364","article-title":"2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy","volume":"42","author":"Glikson","year":"2021","journal-title":"Eur Heart J"}],"container-title":["Europace"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/europace\/article-pdf\/25\/9\/euad208\/51101143\/euad208.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/europace\/article-pdf\/25\/9\/euad208\/51101143\/euad208.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,12]],"date-time":"2023-08-12T06:46:07Z","timestamp":1691822767000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/doi\/10.1093\/europace\/euad208\/7241599"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,2]]},"references-count":26,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2023,8,2]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/euad208","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2023,9]]},"published":{"date-parts":[[2023,8,2]]},"article-number":"euad208"}}