{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T19:56:45Z","timestamp":1789070205957,"version":"build-2803163510"},"reference-count":21,"publisher":"Oxford University Press (OUP)","issue":"9","license":[{"start":{"date-parts":[[2024,9,13]],"date-time":"2024-09-13T00:00:00Z","timestamp":1726185600000},"content-version":"vor","delay-in-days":14,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,8,30]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Aims<\/jats:title>\n                  <jats:p>In complete atrioventricular block (AVB) with underlying sinus rhythm, it is recommended to implant a dual-chamber pacemaker rather than a single-chamber pacemaker. However, no large-scale study has been able to demonstrate the superiority of this choice on hard clinical criteria such as morbimortality.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods and results<\/jats:title>\n                  <jats:p>This retrospective observational study included all patients who received a primary pacemaker implantation in the indication of complete AVB with underlying sinus rhythm in France, based on the national administrative database between January 2013 and December 2022. After propensity score matching, we obtained two groups containing 19 219 patients each. The incidence of all-cause mortality was 9.22%\/year for the dual-chamber pacemaker group, compared with 11.48%\/year for the single-chamber pacemaker group (hazard ratio (HR) 0.807, P &amp;lt; 0.0001]. Similarly, there was a lower incidence of cardiovascular mortality (HR 0.766, P &amp;lt; 0.0001), heart failure (HR 0.908, P &amp;lt; 0.0001), atrial fibrillation (HR 0.778, P &amp;lt; 0.0001), and ischaemic stroke (HR 0.873, P = 0.008) in the dual-chamber pacemaker group than in the single-chamber pacemaker group. Regarding re-interventions and complications, there were fewer upgrades (addition of atrial lead or left ventricular lead) in the dual-chamber group (HR 0.210, P &amp;lt; 0.0001), but more haematomas (HR 1.179, P = 0.006) and lead repositioning (HR 1.123, P = 0.04).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>In the indication of complete AVB with underlying sinus rhythm, our results are consistent with current recommendations to prefer implantation of a dual-chamber pacemaker rather than a single-chamber pacemaker for these patients. Implantation of a dual-chamber pacemaker is associated with a lower risk of mortality, heart failure, atrial fibrillation, and stroke during follow-up.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/europace\/euae238","type":"journal-article","created":{"date-parts":[[2024,9,14]],"date-time":"2024-09-14T08:14:35Z","timestamp":1726301675000},"source":"Crossref","is-referenced-by-count":5,"title":["Dual-chamber vs. single-chamber pacemaker in patients in sinus rhythm with an atrioventricular block: a nationwide cohort study"],"prefix":"10.1093","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6544-3916","authenticated-orcid":false,"given":"Alexandre","family":"Bodin","sequence":"first","affiliation":[{"name":"Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Facult\u00e9 de M\u00e9decine, Universit\u00e9 Fran\u00e7ois Rabelais , 37000 Tours ,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivann","family":"Texier","sequence":"additional","affiliation":[{"name":"Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Facult\u00e9 de M\u00e9decine, Universit\u00e9 Fran\u00e7ois Rabelais , 37000 Tours ,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3449-1800","authenticated-orcid":false,"given":"Arnaud","family":"Bisson","sequence":"additional","affiliation":[{"name":"Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Facult\u00e9 de M\u00e9decine, Universit\u00e9 Fran\u00e7ois Rabelais , 37000 Tours ,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bertrand","family":"Pierre","sequence":"additional","affiliation":[{"name":"Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Facult\u00e9 de M\u00e9decine, Universit\u00e9 Fran\u00e7ois Rabelais , 37000 Tours ,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0373-9591","authenticated-orcid":false,"given":"Julien","family":"Herbert","sequence":"additional","affiliation":[{"name":"Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Facult\u00e9 de M\u00e9decine, Universit\u00e9 Fran\u00e7ois Rabelais , 37000 Tours ,","place":["France"]},{"name":"Service d'Information M\u00e9dicale, D'\u00e9pid\u00e9miologie et d'\u00c9conomie de la Sant\u00e9, Centre Hospitalier Universitaire et EA7505, Facult\u00e9 de M\u00e9decine, Universit\u00e9 Fran\u00e7ois Rabelais , 37000 Tours ,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8803-7275","authenticated-orcid":false,"given":"Mathieu","family":"Jacobs","sequence":"additional","affiliation":[{"name":"Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Facult\u00e9 de M\u00e9decine, Universit\u00e9 Fran\u00e7ois Rabelais , 37000 Tours ,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6128-3214","authenticated-orcid":false,"given":"Mathieu","family":"Nasarre","sequence":"additional","affiliation":[{"name":"Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Facult\u00e9 de M\u00e9decine, Universit\u00e9 Fran\u00e7ois Rabelais , 37000 Tours ,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne","family":"Bernard","sequence":"additional","affiliation":[{"name":"Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Facult\u00e9 de M\u00e9decine, Universit\u00e9 Fran\u00e7ois Rabelais , 37000 Tours ,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9267-1658","authenticated-orcid":false,"given":"Laurent","family":"Fauchier","sequence":"additional","affiliation":[{"name":"Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Facult\u00e9 de M\u00e9decine, Universit\u00e9 Fran\u00e7ois Rabelais , 37000 Tours ,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2024,9,13]]},"reference":[{"key":"2024093009453889400_euae238-B1","doi-asserted-by":"crossref","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab364","article-title":"2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: developed by the task force on cardiac pacing and cardiac resynchronization therapy of the European Society of Cardiology (ESC) with the special contribution of the European Heart Rhythm Association (EHRA)","volume":"42","author":"Glikson","year":"2021","journal-title":"Eur Heart J"},{"key":"2024093009453889400_euae238-B2","doi-asserted-by":"crossref","first-page":"euad202","DOI":"10.1093\/europace\/euad202","article-title":"Cardiac pacing and lead devices management: 25 years of research at EP Europace journal","volume":"25","author":"Defaye","year":"2023","journal-title":"Europace"},{"key":"2024093009453889400_euae238-B3","doi-asserted-by":"crossref","first-page":"846","DOI":"10.1161\/01.CIR.65.5.846","article-title":"A comparison of the acute and long-term hemodynamic effects of ventricular inhibited and atrial synchronous ventricular inhibited pacing","volume":"65","author":"Kruse","year":"1982","journal-title":"Circulation"},{"key":"2024093009453889400_euae238-B4","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1136\/hrt.50.2.112","article-title":"Randomised controlled trial of physiological and ventricular pacing","volume":"50","author":"Perrins","year":"1983","journal-title":"Br Heart J"},{"key":"2024093009453889400_euae238-B5","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1136\/hrt.58.1.34","article-title":"A comparison of symptoms and intra-arterial ambulatory blood pressure during long term dual chamber atrioventricular synchronous (DDD) and ventricular demand (VVI) pacing","volume":"58","author":"Boon","year":"1987","journal-title":"Br Heart J"},{"key":"2024093009453889400_euae238-B6","doi-asserted-by":"crossref","first-page":"1961","DOI":"10.1046\/j.1460-9592.2003.00303.x","article-title":"Long-term complication rates in ventricular, single lead VDD, and dual chamber pacing","volume":"26","author":"Wiegand","year":"2003","journal-title":"Pacing Clin Electrophysiol"},{"key":"2024093009453889400_euae238-B7","doi-asserted-by":"crossref","first-page":"1854","DOI":"10.1056\/NEJMoa013040","article-title":"Ventricular pacing or dual-chamber pacing for sinus-node dysfunction","volume":"346","author":"Lamas","year":"2002","journal-title":"N Engl J Med"},{"key":"2024093009453889400_euae238-B8","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1056\/NEJMoa042283","article-title":"Single-chamber versus dual-chamber pacing for high-grade atrioventricular block","volume":"353","author":"Toff","year":"2005","journal-title":"N Engl J Med"},{"key":"2024093009453889400_euae238-B9","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1056\/NEJMra2308353","article-title":"Cardiac implantable electronic devices","volume":"390","author":"Al-Khatib","year":"2024","journal-title":"N Engl J Med"},{"key":"2024093009453889400_euae238-B10","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1056\/NEJM199804163381602","article-title":"Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing","volume":"338","author":"Lamas","year":"1998","journal-title":"N Engl J Med"},{"key":"2024093009453889400_euae238-B11","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1111\/j.1540-8159.2009.02636.x","article-title":"DDD versus VVIR pacing in patients, ages 70 and over, with complete heart block","volume":"33","author":"Ouali","year":"2010","journal-title":"Pacing Clin Electrophysiol"},{"key":"2024093009453889400_euae238-B12","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1056\/NEJM200005113421902","article-title":"Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. Canadian Trial of Physiologic Pacing Investigators","volume":"342","author":"Connolly","year":"2000","journal-title":"N Engl J Med"},{"key":"2024093009453889400_euae238-B13","doi-asserted-by":"crossref","first-page":"1014","DOI":"10.1016\/j.jclinepi.2010.11.015","article-title":"Hospital discharge data can be used for monitoring procedures and intensive care related to severe maternal morbidity","volume":"64","author":"Chantry","year":"2011","journal-title":"J Clin Epidemiol"},{"key":"2024093009453889400_euae238-B14","first-page":"419","article-title":"Improvement of the quality of medical databases: data-mining-based prediction of diagnostic codes from previous patient codes","volume":"210","author":"Djennaoui","year":"2015","journal-title":"Stud Health Technol Inform"},{"key":"2024093009453889400_euae238-B15","first-page":"475","article-title":"Estimating the prevalence of atrial fibrillation in a general population using validated electronic health data","volume":"5","author":"Norberg","year":"2013","journal-title":"Clin Epidemiol"},{"key":"2024093009453889400_euae238-B16","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1093\/europace\/eux123","article-title":"Five year trends (2008\u20132012) in cardiac implantable electrical device utilization in five European nations: a case study in cross-country comparisons using administrative databases","volume":"20","author":"Banks","year":"2018","journal-title":"Europace"},{"key":"2024093009453889400_euae238-B17","doi-asserted-by":"crossref","first-page":"2027","DOI":"10.1016\/j.hrthm.2021.06.1175","article-title":"Outcomes associated with pacemaker implantation following transcatheter aortic valve replacement: a nationwide cohort study","volume":"18","author":"Clementy","year":"2021","journal-title":"Heart Rhythm"},{"key":"2024093009453889400_euae238-B18","doi-asserted-by":"crossref","first-page":"e025339","DOI":"10.1161\/JAHA.122.025339","article-title":"Leadless or conventional transvenous ventricular permanent pacemakers: a nationwide matched control study","volume":"11","author":"Bodin","year":"2022","journal-title":"J Am Heart Assoc"},{"key":"2024093009453889400_euae238-B19","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1161\/CIRCULATIONAHA.106.678664","article-title":"Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators","volume":"116","author":"Klug","year":"2007","journal-title":"Circulation"},{"key":"2024093009453889400_euae238-B20","doi-asserted-by":"crossref","first-page":"euad065","DOI":"10.1093\/europace\/euad065","article-title":"Avoiding unnecessary ventricular pacing is associated with reduced incidence of heart failure hospitalizations and persistent atrial fibrillation in pacemaker patients","volume":"25","author":"Arnold","year":"2023","journal-title":"Europace"},{"key":"2024093009453889400_euae238-B21","doi-asserted-by":"crossref","first-page":"1585","DOI":"10.1056\/NEJMoa1210356","article-title":"Biventricular pacing for atrioventricular block and systolic dysfunction","volume":"368","author":"Curtis","year":"2013","journal-title":"N Engl J Med"}],"container-title":["Europace"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/europace\/advance-article-pdf\/doi\/10.1093\/europace\/euae238\/59112425\/euae238.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/europace\/article-pdf\/26\/9\/euae238\/59443942\/euae238.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/europace\/article-pdf\/26\/9\/euae238\/59443942\/euae238.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,30]],"date-time":"2024-09-30T09:46:40Z","timestamp":1727689600000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/doi\/10.1093\/europace\/euae238\/7756614"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,30]]},"references-count":21,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2024,8,30]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/euae238","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,9]]},"published":{"date-parts":[[2024,8,30]]},"article-number":"euae238"}}