{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:19:38Z","timestamp":1787008778589,"version":"build-2736575974"},"reference-count":29,"publisher":"Oxford University Press (OUP)","issue":"10","license":[{"start":{"date-parts":[[2024,10,7]],"date-time":"2024-10-07T00:00:00Z","timestamp":1728259200000},"content-version":"vor","delay-in-days":6,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100009647","name":"Ministry of Health","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100009647","id-type":"DOI","asserted-by":"publisher"}]},{"name":"NHH","award":["00023884"],"award-info":[{"award-number":["00023884"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,10,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aims<\/jats:title>\n                    <jats:p>We report our single-centre experience of mid-term to long-term retrieval and reimplantation of a tine-based leadless pacemaker [Micra transcatheter pacing system (TPS)]. The TPS is a clinically effective alternative to transvenous single-chamber ventricular pacemakers. Whereas it is currently recommended to abandon the TPS at the end of device life, catheter-based retrieval may be favourable in specific scenarios.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and results<\/jats:title>\n                    <jats:p>We report on nine consecutive patients with the implanted TPS who subsequently underwent transcatheter retrieval attempts. The retrieval system consists of the original TPS delivery catheter and an off-the-shelf single-loop 7\u2005mm snare. The procedure was guided by fluoroscopy and intracardiac echocardiography. After an implantation duration of 3.1 \u00b1 2.8 years (range 0.4\u20139.0), the overall retrieval success rate was 88.9% (8 of 9 patients). The mean procedure time was 89 \u00b1 16\u2005min, and the fluoroscopy time was 18.0 \u00b1 6.6\u2005min. No procedure-related adverse device events occurred. In the one unsuccessful retrieval, intracardiac echocardiography revealed that the TPS was partially embedded in the ventricular tissue surrounding the leadless pacemaker body in the right ventricle. After retrieval, three patients were reimplanted with a new TPS device. All implantations were successful without complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>A series of transvenous late retrievals of implanted TPS devices demonstrated safety and feasibility, followed by elective replacement with a new leadless pacing device or conventional transvenous pacing system. This provides a viable end-of-life management alternative to simple abandonment of this leadless pacemaker.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/europace\/euae256","type":"journal-article","created":{"date-parts":[[2024,9,30]],"date-time":"2024-09-30T23:20:16Z","timestamp":1727738416000},"source":"Crossref","is-referenced-by-count":17,"title":["Transcatheter non-acute retrieval of the tine-based leadless ventricular pacemaker"],"prefix":"10.1093","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1620-3924","authenticated-orcid":false,"given":"Moritoshi","family":"Funasako","sequence":"first","affiliation":[{"name":"Cardiology Department, Na Homolce Hospital , Roentgenova 37\/2, 15030 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9103-5406","authenticated-orcid":false,"given":"Pavel","family":"H\u00e1la","sequence":"additional","affiliation":[{"name":"Cardiology Department, Na Homolce Hospital , Roentgenova 37\/2, 15030 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marek","family":"Janotka","sequence":"additional","affiliation":[{"name":"Cardiology Department, Na Homolce Hospital , Roentgenova 37\/2, 15030 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"\u0160orf","sequence":"additional","affiliation":[{"name":"Medtronic , Minneapolis, MN ,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucie","family":"Machov\u00e1","sequence":"additional","affiliation":[{"name":"Cardiology Department, Na Homolce Hospital , Roentgenova 37\/2, 15030 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Petr\u016f","sequence":"additional","affiliation":[{"name":"Cardiology Department, Na Homolce Hospital , Roentgenova 37\/2, 15030 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Milan","family":"Chovanec","sequence":"additional","affiliation":[{"name":"Cardiology Department, Na Homolce Hospital , Roentgenova 37\/2, 15030 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"\u0160koda","sequence":"additional","affiliation":[{"name":"Cardiology Department, Na Homolce Hospital , Roentgenova 37\/2, 15030 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0713-7408","authenticated-orcid":false,"given":"Lucie","family":"\u0160ediv\u00e1","sequence":"additional","affiliation":[{"name":"Cardiology Department, Na Homolce Hospital , Roentgenova 37\/2, 15030 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaroslav","family":"\u0160imon","sequence":"additional","affiliation":[{"name":"Cardiology Department, Na Homolce Hospital , Roentgenova 37\/2, 15030 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Libor","family":"Dujka","sequence":"additional","affiliation":[{"name":"Cardiology Department, Na Homolce Hospital , Roentgenova 37\/2, 15030 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5638-4993","authenticated-orcid":false,"given":"Vivek Y","family":"Reddy","sequence":"additional","affiliation":[{"name":"Cardiology Department, Na Homolce Hospital , Roentgenova 37\/2, 15030 Prague ,","place":["Czech Republic"]},{"name":"Department of Cardiology, Icahn School of Medicine at Mount Sinai , New York, NY ,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4334-8165","authenticated-orcid":false,"given":"Petr","family":"Neu\u017eil","sequence":"additional","affiliation":[{"name":"Cardiology Department, Na Homolce Hospital , Roentgenova 37\/2, 15030 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2024,10,7]]},"reference":[{"key":"2024102513062133500_euae256-B1","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euad202","article-title":"Cardiac pacing and lead devices management: 25 years of research at EP Europace journal","volume":"25","author":"Defaye","year":"2023","journal-title":"Europace"},{"key":"2024102513062133500_euae256-B2","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1093\/europace\/euad016","article-title":"Two-year outcomes of leadless vs. transvenous single-chamber ventricular pacemaker in high-risk subgroups","volume":"25","author":"Boveda","year":"2023","journal-title":"Europace"},{"key":"2024102513062133500_euae256-B3","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1056\/NEJMoa1511643","article-title":"A leadless intracardiac transcatheter pacing system","volume":"374","author":"Reynolds","year":"2016","journal-title":"N Engl J Med"},{"key":"2024102513062133500_euae256-B4","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1056\/NEJMoa1507192","article-title":"Percutaneous implantation of an entirely intracardiac leadless pacemaker","volume":"373","author":"Reddy","year":"2015","journal-title":"N Engl J Med"},{"key":"2024102513062133500_euae256-B5","doi-asserted-by":"crossref","first-page":"1375","DOI":"10.1016\/j.hrthm.2017.05.017","article-title":"A leadless pacemaker in the real-world setting: the Micra transcatheter pacing system post-approval registry","volume":"14","author":"Roberts","year":"2017","journal-title":"Heart Rhythm"},{"key":"2024102513062133500_euae256-B6","doi-asserted-by":"crossref","first-page":"e004626","DOI":"10.1161\/CIRCEP.116.004626","article-title":"Retrieval of the leadless cardiac pacemaker: a multicenter experience","volume":"9","author":"Reddy","year":"2016","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2024102513062133500_euae256-B7","doi-asserted-by":"crossref","first-page":"1756","DOI":"10.1016\/j.hrthm.2017.07.004","article-title":"A worldwide experience of the management of battery failures and chronic device retrieval of the Nanostim leadless pacemaker","volume":"14","author":"Lakkireddy","year":"2017","journal-title":"Heart Rhythm"},{"key":"2024102513062133500_euae256-B8","doi-asserted-by":"crossref","first-page":"2249","DOI":"10.1016\/j.jaccas.2020.09.019","article-title":"Successful retrieval of a 4-year-old micra transcatheter pacemaker system in a patient with leadless biventricular pacing therapy","volume":"2","author":"Minami","year":"2020","journal-title":"JACC Case Rep"},{"key":"2024102513062133500_euae256-B9","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1002\/joa3.12814","article-title":"Retrieval of an infectious leadless pacemaker with vegetation","volume":"39","author":"Morita","year":"2023","journal-title":"J Arrhythmia"},{"key":"2024102513062133500_euae256-B10","first-page":"8326020","article-title":"A rare case of persistent bacteremia: leadless Micra pacemaker endocarditis","volume":"2023","author":"Patel","year":"2023","journal-title":"Case Rep Cardiol"},{"key":"2024102513062133500_euae256-B11","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1002\/joa3.12119","article-title":"Successful percutaneous retrieval of a Micra transcatheter pacing system at 8 weeks after implantation","volume":"34","author":"Nozoe","year":"2018","journal-title":"J Arrhythm"},{"key":"2024102513062133500_euae256-B12","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1093\/ehjcr\/ytz113","article-title":"Percutaneous extraction of a leadless Micra after dislocation: a case report","volume":"13","author":"Fichtner","year":"2019","journal-title":"Eur Heart J Case Rep"},{"key":"2024102513062133500_euae256-B13","doi-asserted-by":"crossref","first-page":"1801","DOI":"10.1016\/j.hrthm.2017.07.015","article-title":"To retrieve, or not to retrieve: system revisions with the Micra transcatheter pacemaker","volume":"14","author":"Grubman","year":"2017","journal-title":"Heart Rhythm"},{"key":"2024102513062133500_euae256-B14","author":"Sheldon"},{"key":"2024102513062133500_euae256-B15","doi-asserted-by":"crossref","first-page":"ehac544.486","DOI":"10.1093\/eurheartj\/ehac544.486","article-title":"Real-world long-term battery longevity of leadless pacemakers","volume":"43","author":"Breeman","year":"2022","journal-title":"Eur Heart J"},{"key":"2024102513062133500_euae256-B16","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1111\/pace.14714","article-title":"Percutaneous extraction of a Micra AV transcatheter pacing system due to a rare sudden battery failure after 19 months from implantation: a first experience worldwide","volume":"47","author":"Santobuono","year":"2024","journal-title":"Pacing Clin Electrophysiol"},{"key":"2024102513062133500_euae256-B17","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.hrcr.2015.10.001","article-title":"Extraction of a Micra transcatheter pacing system: first-in-human experience","volume":"2","author":"Karim","year":"2016","journal-title":"HeartRhythm Case Rep"},{"key":"2024102513062133500_euae256-B18","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1111\/pace.13622","article-title":"First-in-human retrieval of chronically implanted Micra transcatheter pacing system","volume":"42","author":"Curnis","year":"2019","journal-title":"Pacing Clin Electrophysiol"},{"key":"2024102513062133500_euae256-B19","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1111\/jce.14946","article-title":"Elective replacement of a 4-year-old leadless pacemaker: new approach for end-of-life management","volume":"32","author":"De Filippo","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2024102513062133500_euae256-B20","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.hrcr.2023.04.004","article-title":"Extraction of a 5-year-old leadless pacemaker using a competing manufacturer\u2019s removal tool","volume":"9","author":"Callahan","year":"2023","journal-title":"HeartRhythm Case Rep"},{"key":"2024102513062133500_euae256-B21","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1016\/j.hrthm.2022.12.002","article-title":"Outcomes of leadless pacemaker implantation following transvenous lead extraction in high-volume referral centers: real-world data from a large international registry","volume":"20","author":"Mitacchione","year":"2023","journal-title":"Heart Rhythm"},{"key":"2024102513062133500_euae256-B22","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.jacep.2016.02.014","article-title":"MICRA leadless pacemaker on autopsy","volume":"2","author":"Vamos","year":"2016","journal-title":"JACC Clin Electrophysiol"},{"key":"2024102513062133500_euae256-B23","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1007\/s00392-015-0929-x","article-title":"Complete encapsulation of a leadless cardiac pacemaker","volume":"105","author":"Kypta","year":"2015","journal-title":"Clin Res Cardiol"},{"key":"2024102513062133500_euae256-B24","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.ccep.2023.10.015","article-title":"Micra extraction out to 4.5 years","volume":"16","author":"Gabrah","year":"2024","journal-title":"Card Electrophysiol Clin"},{"key":"2024102513062133500_euae256-B25","doi-asserted-by":"crossref","first-page":"4562","DOI":"10.19102\/icrm.2021.120606","article-title":"Tips and tricks for safe retrieval of tine-based leadless pacemakers","volume":"12","author":"Afzal","year":"2021","journal-title":"J Innov Cardiac Rhythm Manage"},{"key":"2024102513062133500_euae256-B26","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1016\/j.hrcr.2019.05.002","article-title":"Extraction of a 4-year-old leadless pacemaker with a tine-based fixation","volume":"5","author":"Kiani","year":"2019","journal-title":"HeartRhythm Case Rep"},{"key":"2024102513062133500_euae256-B27","doi-asserted-by":"crossref","first-page":"1706","DOI":"10.1111\/jce.16339","article-title":"Extraction of a 6-year-old leadless pacemaker (MICRA transcatheter pacing system) using commercially available removal tools: a case report","volume":"35","author":"Chmielewska-Michalak","year":"2024","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2024102513062133500_euae256-B28","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.hrcr.2023.10.007","article-title":"Retrieval and replacement feasibility of 7-year-old implanted leadless pacemaker with tines fixation","volume":"10","author":"Neuzil","year":"2024","journal-title":"HeartRhythm Case Rep"},{"key":"2024102513062133500_euae256-B29","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/j.hrcr.2023.01.012","article-title":"Retrieval and replacement of a helix-fixation leadless pacemaker at 9 years post-implant","volume":"9","author":"Neuzil","year":"2023","journal-title":"HeartRhythm Case Rep"}],"container-title":["Europace"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/europace\/advance-article-pdf\/doi\/10.1093\/europace\/euae256\/59633878\/euae256.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/europace\/advance-article-pdf\/doi\/10.1093\/europace\/euae256\/60088094\/euae256.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/europace\/advance-article-pdf\/doi\/10.1093\/europace\/euae256\/60088094\/euae256.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,25]],"date-time":"2024-10-25T09:14:24Z","timestamp":1729847664000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/doi\/10.1093\/europace\/euae256\/7815054"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":29,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2024,10,3]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/euae256","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,10]]},"published":{"date-parts":[[2024,10]]},"article-number":"euae256"}}