{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T16:02:40Z","timestamp":1794326560942,"version":"4.9.0"},"reference-count":137,"publisher":"Oxford University Press (OUP)","issue":"5","license":[{"start":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T00:00:00Z","timestamp":1780012800000},"content-version":"vor","delay-in-days":28,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,5,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>With the rapid increase in percutaneous left heart interventions, transseptal access to the left atrium has become a widely used procedure. This technique is crucial for electrophysiological procedures, particularly for atrial fibrillation ablation, which is estimated to be performed in more than 250 000 patients per year worldwide, as well as for various structural heart interventions, like percutaneous mitral valve repair. Although transseptal puncture (TSP) is generally considered a simple technique, it is associated with a small risk of potentially life-threatening complications. To ensure a successful and safe procedure, a thorough understanding of TSPs\u2019 clinical use, and the anatomy of the interatrial septum\u2014including the fossa ovalis and its anatomical variants\u2014is critical. Since the first fluoroscopy-guided TSP, advancements in echocardiographic imaging have enhanced the precision of the puncture, allowing targeting of specific regions of the fossa ovalis and facilitating difficult procedures. While most TSPs are performed using a Brockenbrough needle and a (steerable) sheath, wide variation in technique exists, and alternative methods have been developed initially aiming for complex cases but now routinely used. Understanding potential complications\u2014such as cardiac tamponade, aortic puncture, and embolism\u2014is essential for prevention, early recognition, and effective management, ultimately improving patients\u2019 outcomes. Finally, understanding how to approach specific complex scenarios is crucial for procedural success.<\/jats:p>","DOI":"10.1093\/europace\/euag021","type":"journal-article","created":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T16:03:16Z","timestamp":1780070596000},"source":"Crossref","is-referenced-by-count":4,"title":["Transseptal puncture in cardiovascular interventions: a clinical consensus statement of the European Heart Rhythm Association, the Heart Failure Association, the European Association of Percutaneous Cardiovascular Interventions, the European Association of Cardiovascular Imaging of the ESC, and the Association for European Paediatric and Congenital Cardiology"],"prefix":"10.1093","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5826-6846","authenticated-orcid":false,"given":"Isabel","family":"Deisenhofer","sequence":"first","affiliation":[{"name":"Department of Electrophysiology, TUM University Hospital German Heart Center, Technical University of Munich (TUM) , Lazarettstr. 36, Munich D-80636 ,","place":["Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6701-7072","authenticated-orcid":false,"given":"Magdy","family":"Abdelhamid","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Faculty of Medicine, Cairo University , Cairo ,","place":["Egypt"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3855-1815","authenticated-orcid":false,"given":"Marianna","family":"Adamo","sequence":"additional","affiliation":[{"name":"Cardiology, ASST Spedali Civili and Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia , Brescia ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7208-5769","authenticated-orcid":false,"given":"Nina","family":"Ajmone Marsan","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Leiden University Medical Center , Leiden ,","place":["The Netherlands"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9092-4458","authenticated-orcid":false,"given":"Nicolas","family":"Amabile","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Institut Cardiovasculaire Paris Sud , Massy ,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caterina","family":"Bisceglia","sequence":"additional","affiliation":[{"name":"Department of Arrhythmology, San Raffaele Hospital , Milan ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4591-4220","authenticated-orcid":false,"given":"Lucas","family":"Boersma","sequence":"additional","affiliation":[{"name":"Department of Cardiology, St. Antonius Hospital, Nieuwegen and Department of Cardiology, Amsterdam University Medical Center , Amsterdam ,","place":["The Netherlands"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Belen Cid","family":"Alvarez","sequence":"additional","affiliation":[{"name":"Servicio de Cardiolog\u00eda, Hospital Cl\u00ednico de Santiago de Compostela , Santiago de Compostela, A Coru\u00f1a ,","place":["Spain"]},{"name":"Centro de Investigaci\u00f3n Biom\u00e9dica en Red de Enfermedades Cardiovasculares (CIBERCV), Instituto de Salud Carlos III , Madrid ,","place":["Spain"]},{"name":"Servicio de Cardiolog\u00eda, Hospital Cl\u00ednico Universitario de Santiago de Compostela, Instituto de Investigaci\u00f3n Sanitaria de Santiago de Compostela (IDIS) , Santiago de Compostela, A Coru\u00f1a ,","place":["Spain"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4311-2139","authenticated-orcid":false,"given":"Stefano","family":"Cornara","sequence":"additional","affiliation":[{"name":"Arrhythmia Unit, Division of Cardiology, Ospedale San Paolo , Savona ,","place":["Italy"]},{"name":"Cardiovascular Research Institute Maastricht (CARIM), Maastricht University , Maastricht ,","place":["The Netherlands"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9841-2737","authenticated-orcid":false,"given":"Victoria","family":"Delgado","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Imaging, ICor University Hospital Germans Trias I Pujol , Badalona ,","place":["Spain"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3490-090X","authenticated-orcid":false,"given":"Dhiraj","family":"Gupta","sequence":"additional","affiliation":[{"name":"Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital , Liverpool, UK"},{"name":"Department of Cardiology, Liverpool Heart & Chest Hospital NHS Foundation Trust , Liverpool ,","place":["UK"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3673-165X","authenticated-orcid":false,"given":"Ulrich","family":"Krause","sequence":"additional","affiliation":[{"name":"Department of Pediatric Cardiology, Intensive Care Medicine and Neonatology, Pediatric Heart Center, Georg-August-University Medical Center , G\u00f6ttingen ,","place":["Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3037-8704","authenticated-orcid":false,"given":"Philipp","family":"Sommer","sequence":"additional","affiliation":[{"name":"Department of Electrophysiology, Heart- and Diabetescenter NRW, Ruhr-University Bochum , Bad Oeynhausen ,","place":["Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2007-1928","authenticated-orcid":false,"given":"Stylianos","family":"Tzeis","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Mitera Hospital, Hygeia Group , Athens ,","place":["Greece"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0448-5143","authenticated-orcid":false,"given":"Dan","family":"Wichterle","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Department of Cardiovascular Medicine, First Faculty of Medicine, Charles University , Prague, Czechia"},{"name":"Department of Medicine, Department of Cardiovascular Medicine, First Faculty of Medicine, Charles University , Prague, Czechia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5878-6750","authenticated-orcid":false,"given":"Marta","family":"de Riva","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Heart-Lung Center, Leiden University Medical Center , Leiden ,","place":["The Netherlands"]},{"name":"Willem Einthoven Center of Arrhythmia Research and Management, Leiden University Medical Center , Leiden ,","place":["The Netherlands"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,5,29]]},"reference":[{"key":"2026053008212892700_euag021-B1","doi-asserted-by":"crossref","first-page":"3314","DOI":"10.1093\/eurheartj\/ehae176","article-title":"2024 ESC guidelines for the management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"45","author":"Van Gelder","year":"2024","journal-title":"Eur Heart J"},{"key":"2026053008212892700_euag021-B2","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euae043","article-title":"2024 European Heart Rhythm Association\/Heart Rhythm Society\/Asia Pacific Heart Rhythm Society\/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"26","author":"Tzeis","year":"2024","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B3","doi-asserted-by":"crossref","first-page":"3503","DOI":"10.1093\/eurheartj\/ehad194","article-title":"2023 ESC guidelines for the management of cardiomyopathies","volume":"44","author":"Arbelo","year":"2023","journal-title":"Eur Heart J"},{"key":"2026053008212892700_euag021-B4","doi-asserted-by":"crossref","first-page":"3997","DOI":"10.1093\/eurheartj\/ehac262","article-title":"2022 ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death","volume":"43","author":"Zeppenfeld","year":"2022","journal-title":"Eur Heart J"},{"key":"2026053008212892700_euag021-B5","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1002\/ejhf.3024","article-title":"2023 focused update of the 2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure: developed by the task force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC) with the special contribution of the Heart Failure Association (HFA) of the ESC","volume":"26","author":"Authors\/Task Force Members","year":"2024","journal-title":"Eur J Heart Fail"},{"key":"2026053008212892700_euag021-B6","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euae298","article-title":"Spotlight on the 2024 ESC\/EACTS management of atrial fibrillation guidelines: 10 novel key aspects","volume":"26","author":"Rienstra","year":"2024","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B7","doi-asserted-by":"crossref","first-page":"305","DOI":"10.2174\/1573403X13666170927122036","article-title":"Transseptal access to the left atrium: tips and tricks to keep it safe derived from single operator experience and review of the literature","volume":"13","author":"Manolis","year":"2017","journal-title":"Curr Cardiol Rev"},{"key":"2026053008212892700_euag021-B8","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1056\/NEJM199809033391003","article-title":"Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins","volume":"339","author":"Ha\u00efssaguerre","year":"1998","journal-title":"N Engl J Med"},{"key":"2026053008212892700_euag021-B9","doi-asserted-by":"crossref","first-page":"3812","DOI":"10.1093\/eurheartj\/ehz837","article-title":"The 2019 ESC guidelines for the management of patients with supraventricular tachycardia","volume":"40","author":"Calkins","year":"2019","journal-title":"Eur Heart J"},{"key":"2026053008212892700_euag021-B10","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.ijcard.2018.06.038","article-title":"Transseptal or retrograde approach for transcatheter ablation of left sided accessory pathways: a systematic review and meta-analysis","volume":"272","author":"Anselmino","year":"2018","journal-title":"Int J Cardiol"},{"key":"2026053008212892700_euag021-B11","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1007\/s10840-006-9043-3","article-title":"Feasibility of the transseptal approach for fast and unstable left ventricular tachycardia mapping and ablation with a non-contact mapping system","volume":"16","author":"Pratola","year":"2006","journal-title":"J Interv Card Electrophysiol"},{"key":"2026053008212892700_euag021-B12","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1007\/s10840-009-9464-x","article-title":"Transseptal versus transaortic approach for radiofrequency ablation in patients with cardioverter-defibrillator and electrical storm","volume":"28","author":"Pluta","year":"2010","journal-title":"J Interv Card Electrophysiol"},{"key":"2026053008212892700_euag021-B13","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1111\/j.1540-8167.2010.01859.x","article-title":"Ultra high-density multipolar mapping with double ventricular access: a novel technique for ablation of ventricular tachycardia","volume":"22","author":"Tung","year":"2011","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026053008212892700_euag021-B14","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1016\/j.jacep.2022.11.017","article-title":"First-in-human experience with ultra-low temperature cryoablation for monomorphic ventricular tachycardia","volume":"9","author":"De Potter","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"key":"2026053008212892700_euag021-B15","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1093\/europace\/euaa320","article-title":"Impact of access route to the left ventricle on asymptomatic periprocedural brain injury: the results of a randomized trial in patients undergoing catheter ablation of ventricular tachycardia","volume":"23","author":"Bori\u0161incov\u00e1","year":"2021","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B16","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.1111\/jce.15896","article-title":"Ventricular arrhythmias in patients with prior aortic valve intervention: characteristics, ablation and outcomes","volume":"34","author":"Khalil","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026053008212892700_euag021-B17","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.jacep.2018.08.008","article-title":"Electrophysiologic substrate, safety, procedural approaches, and outcomes of catheter ablation for ventricular tachycardia in patients after aortic valve replacement","volume":"5","author":"Liang","year":"2019","journal-title":"JACC Clin Electrophysiol"},{"key":"2026053008212892700_euag021-B18","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.1007\/s10840-024-01768-0","article-title":"Safety and hemodynamic implications of transseptal access for ventricular tachycardia ablation in patients with left ventricular assist devices","volume":"67","author":"Curtis","year":"2024","journal-title":"J Interv Card Electrophysiol"},{"key":"2026053008212892700_euag021-B19","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1093\/eurheartj\/ehab395","article-title":"2021 ESC\/EACTS guidelines for the management of valvular heart disease","volume":"43","author":"Vahanian","year":"2022","journal-title":"Eur Heart J"},{"key":"2026053008212892700_euag021-B20","doi-asserted-by":"crossref","first-page":"2307","DOI":"10.1056\/NEJMoa1806640","article-title":"Transcatheter mitral-valve repair in patients with heart failure","volume":"379","author":"Stone","year":"2018","journal-title":"N Engl J Med"},{"key":"2026053008212892700_euag021-B21","doi-asserted-by":"crossref","first-page":"116","DOI":"10.31083\/j.rcm2304116","article-title":"Transcatheter mitral valve repair for primary mitral regurgitation","volume":"23","author":"Attar","year":"2022","journal-title":"Rev Cardiovasc Med"},{"key":"2026053008212892700_euag021-B22","doi-asserted-by":"crossref","first-page":"e230","DOI":"10.4244\/EIJ-D-23-00700","article-title":"Evolving indications for transcatheter mitral edge-to-edge repair","volume":"20","author":"Shuvy","year":"2024","journal-title":"EuroIntervention"},{"key":"2026053008212892700_euag021-B23","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1016\/j.jacc.2017.07.714","article-title":"Transcatheter mitral valve replacement for degenerated bioprosthetic valves and failed annuloplasty rings","volume":"70","author":"Yoon","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"2026053008212892700_euag021-B24","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/j.jacep.2015.11.004","article-title":"Randomized comparison of continuous versus intermittent heparin infusion during catheter ablation of atrial fibrillation","volume":"2","author":"Kim","year":"2016","journal-title":"JACC Clin Electrophysiol"},{"key":"2026053008212892700_euag021-B25","doi-asserted-by":"crossref","first-page":"113","DOI":"10.21037\/acs-2020-mv-104","article-title":"A step-by-step guide to transseptal valve-in-valve transcatheter mitral valve replacement","volume":"10","author":"Harloff","year":"2021","journal-title":"Ann Cardiothorac Surg"},{"key":"2026053008212892700_euag021-B26","doi-asserted-by":"crossref","first-page":"2465","DOI":"10.1016\/j.jcin.2016.10.035","article-title":"Transseptal techniques for emerging structural heart interventions","volume":"9","author":"Alkhouli","year":"2016","journal-title":"JACC Cardiovasc Interv"},{"key":"2026053008212892700_euag021-B27","first-page":"756","article-title":"Utilization of TandemHeart in cardiogenic shock: insights from the THEME registry","volume":"101","author":"Megaly","year":"2023","journal-title":"Catheter Cardiovasc Interv"},{"key":"2026053008212892700_euag021-B28","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1161\/CIRCULATIONAHA.122.062371","article-title":"Unloading the left ventricle in venoarterial ECMO: in whom, when, and how?","volume":"147","author":"Ezad","year":"2023","journal-title":"Circulation"},{"key":"2026053008212892700_euag021-B29","first-page":"315","article-title":"Device-based percutaneous treatments to decompress the left atrium in heart failure with preserved ejection fraction","volume":"28","author":"Riccardi","year":"2023","journal-title":"Heart Fail Rev"},{"key":"2026053008212892700_euag021-B30","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1002\/ejhf.2869","article-title":"Safety, usability, and performance of a wireless left atrial pressure monitoring system in patients with heart failure: the VECTOR-HF trial","volume":"25","author":"D\u2019Amario","year":"2023","journal-title":"Eur J Heart Fail"},{"key":"2026053008212892700_euag021-B31","doi-asserted-by":"crossref","first-page":"1534","DOI":"10.1016\/j.amjcard.2018.02.045","article-title":"Feasibility of left atrial appendage occlusion for left atrial appendage thrombus in patients with persistent atrial fibrillation","volume":"121","author":"Lee","year":"2018","journal-title":"Am J Cardiol"},{"key":"2026053008212892700_euag021-B32","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1016\/j.jacep.2019.11.017","article-title":"Feasibility of left atrial appendage occlusion in left atrial appendage thrombus: a systematic review","volume":"6","author":"Sharma","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2026053008212892700_euag021-B33","doi-asserted-by":"publisher","DOI":"10.1136\/heartjnl-2020-318127","article-title":"Multimodality imaging anatomy of interatrial septum and mitral annulus","author":"Faletra","year":"2020","journal-title":"Heart"},{"key":"2026053008212892700_euag021-B34","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1186\/s43044-020-00109-6","article-title":"Characterization of the interatrial septum by high-field cardiac MRI: a comparison with multi-slice computed tomography","volume":"72","author":"Elagha","year":"2020","journal-title":"Egypt Heart J"},{"key":"2026053008212892700_euag021-B35","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.aanat.2016.01.009","article-title":"Anatomy of the true interatrial septum for transseptal access to the left atrium","volume":"205","author":"Klimek-Piotrowska","year":"2016","journal-title":"Annals of Anatomy\u2014Anatomischer Anzeiger"},{"key":"2026053008212892700_euag021-B36","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0025-6196(12)60336-X","article-title":"Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts","volume":"59","author":"Hagen","year":"1984","journal-title":"Mayo Clin Proc"},{"key":"2026053008212892700_euag021-B37","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1161\/CIRCULATIONAHA.106.627224","article-title":"Congenital heart disease in the general population: changing prevalence and age distribution","volume":"115","author":"Marelli","year":"2007","journal-title":"Circulation"},{"key":"2026053008212892700_euag021-B38","doi-asserted-by":"crossref","first-page":"e173","DOI":"10.4244\/EIJ-D-19-00442","article-title":"Transseptal puncture versus patent foramen ovale or atrial septal defect access for left atrial appendage closure","volume":"16","author":"Kleinecke","year":"2020","journal-title":"EuroIntervention"},{"key":"2026053008212892700_euag021-B39","doi-asserted-by":"crossref","first-page":"720","DOI":"10.4244\/EIJ-D-20-00454","article-title":"Transseptal puncture: procedural guidance, challenging situations and management of complications","volume":"17","author":"Russo","year":"2021","journal-title":"EuroIntervention"},{"key":"2026053008212892700_euag021-B40","first-page":"1138","article-title":"Understanding transcatheter edge-to-edge repair \u201cknobology\u201d: advanced catheter steering for different scenarios of transseptal puncture","volume":"103","author":"Russo","year":"2024","journal-title":"Catheter Cardiovasc Interv"},{"key":"2026053008212892700_euag021-B41","doi-asserted-by":"crossref","first-page":"497","DOI":"10.4244\/EIJV10I4A86","article-title":"Left atrial appendage closure for stroke prevention in non-valvular atrial fibrillation: rationale, devices in clinical development and insights into implantation techniques","volume":"10","author":"Bergmann","year":"2014","journal-title":"EuroIntervention"},{"key":"2026053008212892700_euag021-B42","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.echo.2019.01.009","article-title":"Revisiting anatomy of the interatrial septum and its adjoining atrioventricular junction using noninvasive imaging techniques","volume":"32","author":"Faletra","year":"2019","journal-title":"J Am Soc Echocardiogr"},{"key":"2026053008212892700_euag021-B43","doi-asserted-by":"crossref","first-page":"890","DOI":"10.1111\/j.1540-8167.2012.02381.x","article-title":"Venice Chart international consensus document on atrial fibrillation ablation: 2011 update","volume":"23","author":"Raviele","year":"2012","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026053008212892700_euag021-B44","doi-asserted-by":"crossref","first-page":"1665","DOI":"10.1016\/j.jacc.2011.09.085","article-title":"Patent foramen ovale: the known and the to be known","volume":"59","author":"Kutty","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"2026053008212892700_euag021-B45","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1007\/s10072-021-05330-y","article-title":"Relation between the size of patent foramen ovale and the volume of acute cerebral ischemic lesion in young patients with cryptogenic ischemic stroke","volume":"43","author":"Benvenuti","year":"2022","journal-title":"Neurol Sci"},{"key":"2026053008212892700_euag021-B46","doi-asserted-by":"crossref","first-page":"2785","DOI":"10.1161\/01.CIR.91.11.2785","article-title":"Atrial septal aneurysm in adult patients: a multicenter study using transthoracic and transesophageal echocardiography","volume":"91","author":"M\u00fcgge","year":"1995","journal-title":"Circulation"},{"key":"2026053008212892700_euag021-B47","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1016\/S0894-7317(97)70027-0","article-title":"Atrial septal aneurysm: a new classification in two hundred five adults","volume":"10","author":"Olivares-Reyes","year":"1997","journal-title":"J Am Soc Echocardiogr"},{"key":"2026053008212892700_euag021-B48","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.echo.2016.04.014","article-title":"Lipomatous atrial septal hypertrophy: a review of its anatomy, pathophysiology, multimodality imaging, and relevance to percutaneous interventions","volume":"29","author":"Laura","year":"2016","journal-title":"J Am Soc Echocardiogr"},{"key":"2026053008212892700_euag021-B49","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1016\/j.hrthm.2010.05.005","article-title":"Double atrial septum and transseptal puncture: an unusual obstacle to pulmonary vein isolation","volume":"8","author":"Harding","year":"2011","journal-title":"Heart Rhythm"},{"key":"2026053008212892700_euag021-B50","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1148\/radiographics.20.3.g00ma09639","article-title":"Spectrum of congenital anomalies of the inferior vena cava: cross-sectional imaging findings: (CME available in print version and on RSNA link)","volume":"20","author":"Bass","year":"2000","journal-title":"RadioGraphics"},{"key":"2026053008212892700_euag021-B51","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/j.crad.2011.08.006","article-title":"Congenital anomalies of the inferior vena cava","volume":"67","author":"Malaki","year":"2012","journal-title":"Clin Radiol"},{"key":"2026053008212892700_euag021-B52","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1161\/CIRCEP.110.960856","article-title":"Percutaneous transhepatic venous access for catheter ablation procedures in patients with interruption of the inferior vena cava","volume":"4","author":"Singh","year":"2011","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026053008212892700_euag021-B53","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1111\/pace.14452","article-title":"Result and technique consideration of radiofrequency catheter ablation of tachycardia in patients with dextrocardia","volume":"45","author":"Zhang","year":"2022","journal-title":"Pacing Clinical Electrophis"},{"key":"2026053008212892700_euag021-B54","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1111\/pace.14144","article-title":"Catheter ablation of atrial fibrillation in situs inversus dextrocardia: challenge, improved procedure, outcomes, and literature review","volume":"44","author":"Zhao","year":"2021","journal-title":"Pacing Clinical Electrophis"},{"key":"2026053008212892700_euag021-B55","doi-asserted-by":"crossref","first-page":"100188","DOI":"10.1016\/j.shj.2023.100188","article-title":"The added value of preprocedural cardiac computed tomography in planning left atrial appendage closure with the watchman FLX device","volume":"7","author":"Kassab","year":"2023","journal-title":"Struct Heart"},{"key":"2026053008212892700_euag021-B56","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1016\/j.jcin.2021.04.037","article-title":"Anatomic approach to transseptal puncture for structural heart interventions","volume":"14","author":"Simard","year":"2021","journal-title":"JACC Cardiovasc Interv"},{"key":"2026053008212892700_euag021-B57","doi-asserted-by":"crossref","first-page":"3257","DOI":"10.1053\/j.jvca.2021.12.025","article-title":"A sequential approach for echocardiographic guidance of transseptal puncture: the PITLOC protocol","volume":"36","author":"Katsiampoura","year":"2022","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"2026053008212892700_euag021-B58","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1016\/j.hrthm.2014.03.003","article-title":"Does periprocedural anticoagulation management of atrial fibrillation affect the prevalence of silent thromboembolic lesion detected by diffusion cerebral magnetic resonance imaging in patients undergoing radiofrequency atrial fibrillation ablation with open irrigated catheters? Results from a prospective multicenter study","volume":"11","author":"Di Biase","year":"2014","journal-title":"Heart Rhythm"},{"key":"2026053008212892700_euag021-B59","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.jacc.2023.08.017","article-title":"2023 ACC\/AHA\/ACCP\/HRS guideline for the diagnosis and management of atrial fibrillation: a report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines","volume":"83","author":"Writing Committee Members","year":"2024","journal-title":"J Am Coll Cardiol"},{"key":"2026053008212892700_euag021-B60","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.ahj.2024.02.015","article-title":"Strategy to optimize PeriproCeduraL AnticOagulation in structural transseptal interventions: design and rationale of the STOP CLOT trial","volume":"271","author":"Pr\u0119gowski","year":"2024","journal-title":"Am Heart J"},{"key":"2026053008212892700_euag021-B61","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1111\/jce.14294","article-title":"How to perform left atrial transseptal access and catheter ablation of atrial fibrillation from a superior approach","volume":"31","author":"Santangeli","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026053008212892700_euag021-B62","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.1111\/jce.13042","article-title":"Vascular complications during catheter ablation of cardiac arrhythmias: a comparison between vascular ultrasound guided access and conventional vascular access","volume":"27","author":"Sharma","year":"2016","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026053008212892700_euag021-B63","first-page":"850","article-title":"Ultrasound-guided cannulation of the femoral vein in electrophysiological procedures: a systematic review and meta-analysis","volume":"19","author":"Sobolev","year":"2017","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B64","doi-asserted-by":"crossref","first-page":"1500","DOI":"10.1093\/europace\/euad060","article-title":"Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath","volume":"25","author":"Kueffer","year":"2023","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B65","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1007\/s10840-010-9531-3","article-title":"Particle formation and risk of embolization during transseptal catheterization: comparison of standard transseptal needles and a new radiofrequency transseptal needle","volume":"30","author":"Feld","year":"2011","journal-title":"J Interv Card Electrophysiol"},{"key":"2026053008212892700_euag021-B66","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1007\/s10840-021-01086-9","article-title":"A standardized stepwise zero-fluoroscopy approach with transesophageal echocardiography guidance for atrial fibrillation ablation","volume":"64","author":"Falasconi","year":"2022","journal-title":"J Interv Card Electrophysiol"},{"key":"2026053008212892700_euag021-B67","doi-asserted-by":"crossref","first-page":"1642","DOI":"10.1016\/j.hrthm.2018.06.045","article-title":"Protamine to expedite vascular hemostasis after catheter ablation of atrial fibrillation: a randomized controlled trial","volume":"15","author":"Ghannam","year":"2018","journal-title":"Heart Rhythm"},{"key":"2026053008212892700_euag021-B68","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1177\/1474515119830297","article-title":"Nurse-performed venous sheath removal in patients undergoing radiofrequency catheter ablation for atrial fibrillation: a randomised study","volume":"18","author":"Rolantova","year":"2019","journal-title":"Eur J Cardiovasc Nurs"},{"key":"2026053008212892700_euag021-B69","doi-asserted-by":"crossref","first-page":"34","DOI":"10.31083\/j.rcm2301034","article-title":"Periprocedural outcomes of protamine administration after catheter ablation of atrial fibrillation","volume":"23","author":"Kewcharoen","year":"2022","journal-title":"Rev Cardiovasc Med"},{"key":"2026053008212892700_euag021-B70","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1093\/europace\/eux274","article-title":"2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"20","author":"Calkins","year":"2018","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B71","doi-asserted-by":"crossref","first-page":"euad349","DOI":"10.1093\/europace\/euad349","article-title":"Angioplasty guidewire-assisted vs. conventional transseptal puncture for left atrial appendage occlusion: a multicentre randomized controlled trial","volume":"25","author":"Hu","year":"2023","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B72","first-page":"113","article-title":"Electrosurgical energy in combination with a transseptal needle: a novel method for the creation of an atrial communication in hypoplastic left heart syndrome with intact atrial septum","volume":"73","author":"Gordon","year":"2009","journal-title":"Catheter Cardiovasc Interv"},{"key":"2026053008212892700_euag021-B73","doi-asserted-by":"crossref","first-page":"579","DOI":"10.4244\/EIJV8I5A89","article-title":"Transseptal access for MitraClip\u00ae procedures using surgical diathermy under echocardiographic guidance","volume":"8","author":"Maisano","year":"2012","journal-title":"EuroInterv"},{"key":"2026053008212892700_euag021-B74","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1161\/CIRCEP.111.968040","article-title":"Incidence of tissue coring during transseptal catheterization when using electrocautery and a standard transseptal needle","volume":"5","author":"Greenstein","year":"2012","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026053008212892700_euag021-B75","doi-asserted-by":"crossref","first-page":"1401","DOI":"10.1093\/europace\/eur155","article-title":"The use of a novel nitinol guidewire to facilitate transseptal puncture and left atrial catheterization for catheter ablation procedures","volume":"13","author":"Wadehra","year":"2011","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B76","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1016\/j.jacep.2022.10.017","article-title":"Randomized comparison of a radiofrequency wire versus a radiofrequency needle system for transseptal puncture","volume":"9","author":"Dewland","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"key":"2026053008212892700_euag021-B77","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1016\/0002-9149(59)90347-9","article-title":"Transseptal left atrial puncture; new technique for the measurement of left atrial pressure in man","volume":"3","author":"Ross","year":"1959","journal-title":"Am J Cardiol"},{"key":"2026053008212892700_euag021-B78","doi-asserted-by":"crossref","first-page":"2278","DOI":"10.1161\/CIRCULATIONAHA.117.031343","article-title":"Use of intracardiac echocardiography in interventional cardiology: working with the anatomy rather than fighting it","volume":"137","author":"Enriquez","year":"2018","journal-title":"Circulation"},{"key":"2026053008212892700_euag021-B79","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1016\/j.jcin.2020.03.015","article-title":"3-Dimensional transseptal puncture based on electrographic characteristics of fossa ovalis: a fluoroscopy-free and echocardiography-free method","volume":"13","author":"Yu","year":"2020","journal-title":"JACC Cardiovasc Interv"},{"key":"2026053008212892700_euag021-B80","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1016\/j.hlc.2016.01.018","article-title":"Electroanatomic mapping and transoesophageal echocardiography for near zero fluoroscopy during complex left atrial ablation","volume":"25","author":"Raju","year":"2016","journal-title":"Heart Lung Circ"},{"key":"2026053008212892700_euag021-B81","doi-asserted-by":"crossref","first-page":"3270","DOI":"10.1111\/jce.15272","article-title":"A reliable fossa ovalis impedance mapping for safer transseptal puncture: a new vision beyond voltage","volume":"32","author":"Pentimalli","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026053008212892700_euag021-B82","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euae098","article-title":"Optimizing transseptal puncture guided by three-dimensional mapping: the role of a unipolar electrogram in a needle tip","volume":"26","author":"Chen","year":"2024","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B83","doi-asserted-by":"crossref","first-page":"2023","DOI":"10.1093\/europace\/euw432","article-title":"Safety of fluoroscopy-guided transseptal approach for ablation of left-sided arrhythmias","volume":"19","author":"Matoshvili","year":"2017","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B84","doi-asserted-by":"crossref","first-page":"3292","DOI":"10.1053\/j.jvca.2022.02.015","article-title":"Complications of transesophageal echocardiography: a review of injuries, risk factors, and management","volume":"36","author":"Patel","year":"2022","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"2026053008212892700_euag021-B85","doi-asserted-by":"crossref","first-page":"2133","DOI":"10.1016\/j.jcin.2018.06.056","article-title":"Intracardiac echocardiography in structural heart disease interventions","volume":"11","author":"Alkhouli","year":"2018","journal-title":"JACC Cardiovasc Interv"},{"key":"2026053008212892700_euag021-B86","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euad086","article-title":"Safety and efficacy of intracardiac echocardiography-guided zero-fluoroscopic cryoballoon ablation for atrial fibrillation: a prospective randomized controlled trial","volume":"25","author":"Ahn","year":"2023","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B87","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1007\/s11886-017-0902-6","article-title":"Intracardiac echocardiography for structural heart and electrophysiological interventions","volume":"19","author":"Basman","year":"2017","journal-title":"Curr Cardiol Rep"},{"key":"2026053008212892700_euag021-B88","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1007\/s10840-020-00844-5","article-title":"Does the use of intracardiac echocardiography during atrial fibrillation catheter ablation improve outcomes and cost? A nationwide 14-year analysis from 2001 to 2014","volume":"61","author":"Isath","year":"2021","journal-title":"J Interv Card Electrophysiol"},{"key":"2026053008212892700_euag021-B89","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1093\/europace\/euaa034","article-title":"3D mapping for the identification of the fossa ovalis in left atrial ablation procedures: a pilot study of a first step towards an electroanatomic-guided transseptal puncture","volume":"22","author":"Eichenlaub","year":"2020","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B90","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.1093\/europace\/euac262","article-title":"Feasibility and safety of a three-dimensional anatomic map\u2013guided transseptal puncture for left-sided catheter ablation procedures","volume":"25","author":"Bohnen","year":"2023","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B91","first-page":"135","article-title":"[On the histological structure of the fossa ovalis of the heart]","volume":"112","author":"Voigt","year":"1963","journal-title":"Anat Anz"},{"key":"2026053008212892700_euag021-B92","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1093\/europace\/euaa063","article-title":"Searching for fossa ovalis using 3D electroanatomic mapping: look before the jump","volume":"22","author":"Guo","year":"2020","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B93","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/pace.13541","article-title":"A novel technique for performing transseptal puncture guided by a non-fluoroscopic 3D mapping system","volume":"42","author":"Sawhney","year":"2019","journal-title":"Pacing Clin Electrophysiol"},{"key":"2026053008212892700_euag021-B94","first-page":"1333","article-title":"Zero-fluoroscopy cardiac ablation: technology is moving forward in complex procedures-A novel workflow for atrial fibrillation","volume":"10","author":"Bertini","year":"2021","journal-title":"Biology (Basel)"},{"key":"2026053008212892700_euag021-B95","doi-asserted-by":"crossref","first-page":"1106","DOI":"10.1093\/europace\/euz042","article-title":"Inadvertent transseptal puncture into the aortic root: the narrow edge between luck and catastrophe in interventional cardiology","volume":"21","author":"Chen","year":"2019","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B96","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1016\/j.jacc.2005.10.046","article-title":"Trans-septal catheterization in the electrophysiology laboratory","volume":"47","author":"De Ponti","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"2026053008212892700_euag021-B97","doi-asserted-by":"crossref","first-page":"5352","DOI":"10.1016\/j.ijcard.2013.08.004","article-title":"Complications of transseptal catheterization for different cardiac procedures","volume":"168","author":"Katritsis","year":"2013","journal-title":"Int J Cardiol"},{"key":"2026053008212892700_euag021-B98","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.ijcard.2017.02.009","article-title":"Transseptal puncture\u2014review of anatomy, techniques, complications and challenges","volume":"233","author":"O\u2019Brien","year":"2017","journal-title":"Int J Cardiol"},{"key":"2026053008212892700_euag021-B99","doi-asserted-by":"crossref","first-page":"1944","DOI":"10.1093\/europace\/euy131","article-title":"Cardiac tamponade in catheter ablation of atrial fibrillation: German-wide analysis of 21 141 procedures in the Helio s a trial f ibrillation ablation r e gist r y (SAFER)","volume":"20","author":"Bollmann","year":"2018","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B100","doi-asserted-by":"crossref","first-page":"1725","DOI":"10.4244\/EIJ-D-18-00961","article-title":"Incidence and in-hospital safety outcomes of patients undergoing percutaneous mitral valve edge-to-edge repair using MitraClip: five-year German national patient sample including 13,575 implants","volume":"14","author":"Von Bardeleben","year":"2019","journal-title":"EuroIntervention"},{"key":"2026053008212892700_euag021-B101","doi-asserted-by":"crossref","first-page":"1747","DOI":"10.1111\/jce.15590","article-title":"Transseptal puncture for left atrial ablation: risk factors for cardiac tamponade and a proposed causative classification system","volume":"33","author":"Maclean","year":"2022","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026053008212892700_euag021-B102","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.jacep.2020.01.011","article-title":"Predictors of cardiac perforation with catheter ablation of atrial fibrillation","volume":"6","author":"Friedman","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2026053008212892700_euag021-B103","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.ijcard.2022.01.011","article-title":"Transseptal puncture: review of anatomy, techniques, complications and challenges, a critical view","volume":"351","author":"Almendarez","year":"2022","journal-title":"Int J Cardiol"},{"key":"2026053008212892700_euag021-B104","doi-asserted-by":"crossref","first-page":"984251","DOI":"10.3389\/fcvm.2022.984251","article-title":"Direct autotransfusion in the management of acute pericardial tamponade during catheter ablation for atrial fibrillation: an imperfect but practical method","volume":"9","author":"Zhao","year":"2022","journal-title":"Front Cardiovasc Med"},{"key":"2026053008212892700_euag021-B105","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1007\/s11886-023-01858-x","article-title":"When and how to use reversal agents for direct oral anticoagulants?","volume":"25","author":"G\u00f3mez-Outes","year":"2023","journal-title":"Curr Cardiol Rep"},{"key":"2026053008212892700_euag021-B106","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1111\/jce.14332","article-title":"Early versus delayed removal of the pericardial drain in patients with cardiac tamponade complicating radiofrequency ablation of atrial fibrillation","volume":"31","author":"Zhao","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026053008212892700_euag021-B107","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/j.jacep.2016.09.016","article-title":"Management of tamponade complicating catheter ablation for atrial fibrillation","volume":"3","author":"Pedersen","year":"2017","journal-title":"JACC Clin Electrophysiol"},{"key":"2026053008212892700_euag021-B108","first-page":"447","article-title":"Incidence and management of inadvertent puncture and sheath placement in the aorta during attempted transseptal puncture","volume":"19","author":"Wasmer","year":"2017","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B109","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1093\/eurheartj\/ehaa612","article-title":"2020 ESC guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"42","author":"Hindricks","year":"2021","journal-title":"Eur Heart J"},{"key":"2026053008212892700_euag021-B110","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1007\/s10840-019-00608-w","article-title":"Transseptal puncture performed with the new needle-free \u2018SafeSept\u2019 guidewire: a multicentre experience","volume":"59","author":"Chow","year":"2020","journal-title":"J Interv Card Electrophysiol"},{"key":"2026053008212892700_euag021-B111","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.hrcr.2015.12.003","article-title":"Successful interventional management of catastrophic coronary arterial air embolism during atrial fibrillation ablation","volume":"2","author":"Ahmad","year":"2016","journal-title":"HeartRhythm Case Rep"},{"key":"2026053008212892700_euag021-B112","first-page":"e003545","article-title":"Iatrogenic atrial septal defect","volume":"9","author":"Alkhouli","year":"2016","journal-title":"Circ: Cardiovascular Interventions"},{"key":"2026053008212892700_euag021-B113","doi-asserted-by":"crossref","first-page":"e001732","DOI":"10.1136\/openhrt-2021-001732","article-title":"Prevalence of iatrogenic atrial septal defects (iASD) after mitral valve (MV) transcatheter edge-to-edge repair (TEER) in the long-term follow-up","volume":"8","author":"Paukovitsch","year":"2021","journal-title":"Open Heart"},{"key":"2026053008212892700_euag021-B114","doi-asserted-by":"crossref","first-page":"362.e1","DOI":"10.1016\/j.ahj.2006.04.034","article-title":"Persistence of iatrogenic atrial septal defect after pulmonary vein isolation\u2014an underestimated risk?","volume":"152","author":"Hammerstingl","year":"2006","journal-title":"Am Heart J"},{"key":"2026053008212892700_euag021-B115","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1007\/s10840-018-0352-0","article-title":"High rate of persistent iatrogenic atrial septal defect after single transseptal puncture for cryoballoon pulmonary vein isolation","volume":"52","author":"Linhart","year":"2018","journal-title":"J Interv Card Electrophysiol"},{"key":"2026053008212892700_euag021-B116","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1161\/CIRCULATIONAHA.120.051989","article-title":"Closure of iatrogenic atrial septal defect after transcatheter mitral valve repair: the randomized MITHRAS trial","volume":"143","author":"Lurz","year":"2021","journal-title":"Circulation"},{"key":"2026053008212892700_euag021-B117","doi-asserted-by":"crossref","first-page":"760","DOI":"10.1016\/j.hrcr.2022.08.008","article-title":"Refractory hypoxemia from intracardiac shunting following ventricular tachycardia ablation in a patient with a left ventricular assist device","volume":"8","author":"Oates","year":"2022","journal-title":"HeartRhythm Case Rep"},{"key":"2026053008212892700_euag021-B118","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1093\/eurheartj\/ehaa1027","article-title":"A right-to-left atrial shunt via an iatrogenic atrial septal defect after atrial fibrillation ablation induced by a percutaneous left ventricular assist device","volume":"43","author":"Tamura","year":"2022","journal-title":"Eur Heart J"},{"key":"2026053008212892700_euag021-B119","doi-asserted-by":"crossref","first-page":"2328","DOI":"10.1111\/jce.14616","article-title":"Safety and efficacy of catheter ablation for atrial fibrillation in patients with percutaneous atrial septal closure device: Electrophysiology Collaborative Consortium for Meta-analysis\u2014ELECTRAM Investigators","volume":"31","author":"Garg","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026053008212892700_euag021-B120","doi-asserted-by":"crossref","first-page":"ytad139","DOI":"10.1093\/ehjcr\/ytad139","article-title":"Single puncture approach guided by transesophageal echocardiography for atrial fibrillation ablation in a patient with prior percutaneous septal closure: case report","volume":"7","author":"Oliveira","year":"2023","journal-title":"European Heart Journal\u2014Case Reports"},{"key":"2026053008212892700_euag021-B121","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1016\/j.hrthm.2013.11.011","article-title":"Safety and feasibility of transseptal puncture for atrial fibrillation ablation in patients with atrial septal defect closure devices","volume":"11","author":"Li","year":"2014","journal-title":"Heart Rhythm"},{"key":"2026053008212892700_euag021-B122","doi-asserted-by":"crossref","first-page":"1112","DOI":"10.4244\/EIJ-D-21-00340","article-title":"Transseptal puncture in patients with septal occluder devices during catheter ablation of atrial fibrillation","volume":"17","author":"Guo","year":"2022","journal-title":"EuroIntervention"},{"key":"2026053008212892700_euag021-B123","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1093\/europace\/eum070","article-title":"One-puncture, double-transseptal catheterization manoeuvre in the catheter ablation of atrial fibrillation","volume":"9","author":"Yamada","year":"2007","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B124","doi-asserted-by":"crossref","first-page":"671","DOI":"10.5603\/CJ.a2020.0037","article-title":"Impact of single versus double transseptal puncture on outcome and complications in pulmonary vein isolation procedures","volume":"28","author":"Stauber","year":"2021","journal-title":"Cardiol J"},{"key":"2026053008212892700_euag021-B125","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1007\/s00246-020-02530-9","article-title":"Safety of transseptal puncture for access to the left atrium in infants and children","volume":"42","author":"M\u00fcller","year":"2021","journal-title":"Pediatr Cardiol"},{"key":"2026053008212892700_euag021-B126","first-page":"198","article-title":"Transseptal left heart catheterisation in infants, children, and young adults","volume":"17","author":"Ali Khan","year":"1989","journal-title":"Cathet Cardiovasc Diagn"},{"key":"2026053008212892700_euag021-B127","doi-asserted-by":"crossref","first-page":"1581","DOI":"10.1093\/europace\/euv383","article-title":"Feasibility and safety of transseptal puncture procedures for radiofrequency catheter ablation in small children weighing below 30 kg: single-centre experience","volume":"18","author":"Yoshida","year":"2016","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B128","first-page":"434","article-title":"18-year experience with transseptal procedures through baffles, conduits, and other intra-atrial patches","volume":"50","author":"El-Said","year":"2000","journal-title":"Catheter Cardiovasc Interv"},{"key":"2026053008212892700_euag021-B129","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1111\/j.1540-8183.2001.tb00345.x","article-title":"Intervention in the critically ill neonate and infant with hypoplastic left heart syndrome and intact atrial septum","volume":"14","author":"Cheatham","year":"2001","journal-title":"J Interv Cardiol"},{"key":"2026053008212892700_euag021-B130","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1093\/europace\/eut237","article-title":"The use of an integrated electroanatomic mapping system and intracardiac echocardiography to reduce radiation exposure in children and young adults undergoing ablation of supraventricular tachycardia","volume":"16","author":"Mah","year":"2014","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B131","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1016\/j.ijcard.2016.08.220","article-title":"Atrial septal aneurysm: prevalence and covariates in adults","volume":"223","author":"Yetkin","year":"2016","journal-title":"Int J Cardiol"},{"key":"2026053008212892700_euag021-B132","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.echo.2011.01.022","article-title":"Imaging the atrial septum using real-time three-dimensional transesophageal echocardiography: technical tips, normal anatomy, and its role in transseptal puncture","volume":"24","author":"Faletra","year":"2011","journal-title":"J Am Soc Echocardiogr"},{"key":"2026053008212892700_euag021-B133","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1016\/j.jacep.2019.10.019","article-title":"Radiofrequency-assisted transseptal access for atrial fibrillation ablation via a superior approach","volume":"6","author":"Liang","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2026053008212892700_euag021-B134","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euae243","article-title":"2024 updated European Heart Rhythm Association core curriculum for physicians and allied professionals: a statement of the European Heart Rhythm Association of the European Society of Cardiology","volume":"26","author":"Trines","year":"2024","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B135","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euae037","article-title":"Utilization of and perceived need for simulators in clinical electrophysiology: results from an EHRA physician survey","volume":"26","author":"Tjong","year":"2024","journal-title":"Europace"},{"key":"2026053008212892700_euag021-B136","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.jacc.2011.02.063","article-title":"Superiority of simulator-based training compared with conventional training methodologies in the performance of transseptal catheterization","volume":"58","author":"De Ponti","year":"2011","journal-title":"J Am Coll Cardiol"},{"key":"2026053008212892700_euag021-B137","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1111\/pace.12030","article-title":"Use of intracardiac echocardiography during atrial fibrillation ablation","volume":"36","author":"Ruisi","year":"2013","journal-title":"Pacing Clin Electrophysiol"}],"container-title":["Europace"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/europace\/article-pdf\/28\/5\/euag021\/68430227\/euag021.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/europace\/article-pdf\/28\/5\/euag021\/68430227\/euag021.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T12:21:50Z","timestamp":1780143710000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/doi\/10.1093\/europace\/euag021\/8697897"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":137,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5,6]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/euag021","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,5]]},"published":{"date-parts":[[2026,5]]},"article-number":"euag021"}}