{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:51:54Z","timestamp":1790729514989,"version":"4.1.0"},"reference-count":196,"publisher":"Oxford University Press (OUP)","issue":"6","license":[{"start":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T00:00:00Z","timestamp":1775952000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,6,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Pulsed field ablation has emerged as a novel non-thermal treatment modality with a distinct safety profile for the interventional treatment of atrial fibrillation. By inducing irreversible electroporation, pulsed field ablation achieves myocardial ablation while preserving surrounding structures such as nerves, vasculature, and the oesophagus. This European Heart Rhythm Association of the European Society of Cardiology scientific statement, endorsed by major international societies, reviews the biophysics, technology, clinical evidence, workflow, safety, and training aspects of pulsed field ablation. Randomized trials demonstrate comparable efficacy to radiofrequency and cryoballoon ablation, with advantages in safety and efficiency. The statement provides practical advice for clinical implementation and operator training and identifies key gaps in evidence and priorities for future research and innovation.<\/jats:p>","DOI":"10.1093\/europace\/euag080","type":"journal-article","created":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T11:46:10Z","timestamp":1775821570000},"source":"Crossref","is-referenced-by-count":20,"title":["Pulsed field ablation for the interventional treatment of atrial fibrillation: a scientific statement of the European Heart Rhythm Association of the European Society of Cardiology, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society, and the Canadian Heart Rhythm Society"],"prefix":"10.1093","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2937-3711","authenticated-orcid":false,"given":"Michael","family":"K\u00fchne","sequence":"first","affiliation":[{"name":"Department of Cardiology, University Hospital Basel , Petersgraben 4, Basel 4031 ,","place":["Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9751-0557","authenticated-orcid":false,"given":"Patrick","family":"Badertscher","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Hospital Basel , Petersgraben 4, Basel 4031 ,","place":["Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8493-5123","authenticated-orcid":false,"given":"Jason G","family":"Andrade","sequence":"additional","affiliation":[{"name":"Department of Medicine, Vancouver General Hospital , Vancouver ,","place":["Canada"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6864-3999","authenticated-orcid":false,"given":"Ante","family":"Anic","sequence":"additional","affiliation":[{"name":"Department for Cardiovascular Diseases, University Hospital Centre Split , Split ,","place":["Croatia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2355-6015","authenticated-orcid":false,"given":"Julian","family":"Chun","sequence":"additional","affiliation":[{"name":"Cardioangiologisches Centrum Bethanien (CCB) Department of Cardiology, , Frankfurt am Main ,","place":["Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7737-421X","authenticated-orcid":false,"given":"Antonio","family":"Dello Russo","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, Marche University Hospital , Ancona ,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4700-7811","authenticated-orcid":false,"given":"Pierre","family":"Jais","sequence":"additional","affiliation":[{"name":"H\u00f4pital Cardiologique du Haut-L\u00e9v\u00e8que, CHU Bordeaux, LIRYC, Universit\u00e9 de Bordeaux , Bordeaux ,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1632-6182","authenticated-orcid":false,"given":"Josef","family":"Kautzner","sequence":"additional","affiliation":[{"name":"Institute for Clinical and Experimental Medicine (IKEM) Department of Cardiology, , Prague, Czechia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2377-1417","authenticated-orcid":false,"given":"Heiko","family":"Lehrmann","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Faculty of Medicine, University Heart Center Freiburg-Bad Krozingen, University Hospital Freiburg , Freiburg im Breisgau ,","place":["Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7755-3613","authenticated-orcid":false,"given":"Claire","family":"Martin","sequence":"additional","affiliation":[{"name":"Cardiology Department, Royal Papworth Hospital , Cambridge ,","place":["UK"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1737-1903","authenticated-orcid":false,"given":"Jose Luis","family":"Merino","sequence":"additional","affiliation":[{"name":"La Paz University Hospital Research Institute (IdiPAZ), Universidad Aut\u00f3noma de Madrid , Madrid ,","place":["Spain"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3506-9449","authenticated-orcid":false,"given":"Damijan","family":"Miklavcic","sequence":"additional","affiliation":[{"name":"Faculty of Electrical Engineering, University of Ljubljana , Ljubljana ,","place":["Slovenia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6601-944X","authenticated-orcid":false,"given":"Andrea","family":"Natale","sequence":"additional","affiliation":[{"name":"Texas Cardiac Arrhythmia Institute, St David\u2019s Medical Center , Austin ,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2075-8113","authenticated-orcid":false,"given":"Kars","family":"Neven","sequence":"additional","affiliation":[{"name":"Department of Electrophysiology, Alfried Krupp Hospital , Essen ,","place":["Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1825-8766","authenticated-orcid":false,"given":"Armando","family":"Perez-Silva","sequence":"additional","affiliation":[{"name":"Hospital Regional de Concepcion Department of Cardiology, , Concepcion ,","place":["Chile"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0772-2404","authenticated-orcid":false,"given":"Jonathan","family":"Piccini","sequence":"additional","affiliation":[{"name":"Duke Clinical Research Institute Department of Medicine, Division of Cardiology, , Durham ,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7197-8415","authenticated-orcid":false,"given":"Tobias","family":"Reichlin","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Inselspital Bern, University of Bern , Bern ,","place":["Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0303-1497","authenticated-orcid":false,"given":"Raphael","family":"Rosso","sequence":"additional","affiliation":[{"name":"Tel Aviv University, School of Medicine Tel Aviv Sourasky Medical Center, , Tel Aviv ,","place":["Israel"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1541-309X","authenticated-orcid":false,"given":"Martin","family":"Ruwald","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Copenhagen Heart Center , Copenhagen ,","place":["Denmark"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6327-0487","authenticated-orcid":false,"given":"Andrea","family":"Sarkozy","sequence":"additional","affiliation":[{"name":"Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Heart Rhythm Research Brussels, Postgraduate Program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, European Reference Networks Guard-Heart , Brussels ,","place":["Belgium"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5868-5493","authenticated-orcid":false,"given":"Daniel","family":"Scherr","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Internal Medicine, Medical University of Graz , Graz ,","place":["Austria"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1807-4860","authenticated-orcid":false,"given":"Arian","family":"Sultan","sequence":"additional","affiliation":[{"name":"St.Georg Heart Center Hamburg, Asklepios Clinic Hamburg , Hamburg ,","place":["Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8578-2328","authenticated-orcid":false,"given":"Hiroshi","family":"Tada","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui , Fukui ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2007-1928","authenticated-orcid":false,"given":"Stylianos","family":"Tzeis","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Mitera Hospital , Athens ,","place":["Greece"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1020-9727","authenticated-orcid":false,"given":"Atul","family":"Verma","sequence":"additional","affiliation":[{"name":"Department of Medicine, McGill University Health Center , Montreal ,","place":["Canada"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8254-2705","authenticated-orcid":false,"given":"Bradley","family":"Wilsmore","sequence":"additional","affiliation":[{"name":"Private Practice , Merewether, New South Wales ,","place":["Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8965-8495","authenticated-orcid":false,"given":"Helmut","family":"P\u00fcrerfellner","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Ordensklinikum Linz Elisabethinen , Linz ,","place":["Austria"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,4,12]]},"reference":[{"key":"2026092807170433300_euag080-B1","doi-asserted-by":"crossref","first-page":"e24","DOI":"10.15420\/aer.2025.37","article-title":"Complexity and perplexity of pulsed field ablation: an engineering perspective","volume":"14","author":"Kos","year":"2025","journal-title":"Arrhythm Electrophysiol Rev"},{"key":"2026092807170433300_euag080-B2","doi-asserted-by":"crossref","first-page":"euaf203","DOI":"10.1093\/europace\/euaf203","article-title":"Controversy: the blanking period after atrial fibrillation ablation is needed and should be maintained","volume":"27","author":"P\u00fcrerfellner","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B3","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1093\/europace\/eum007","article-title":"Internal atrial shock delivery by standard diagnostic electrophysiology catheters in goats: effects on atrial electrogram amplitude and tissue architecture","volume":"9","author":"Wijffels","year":"2007","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B4","doi-asserted-by":"crossref","first-page":"E162","DOI":"10.1532\/HSF98.20061202","article-title":"A novel nonthermal energy source for surgical epicardial atrial ablation: irreversible electroporation","volume":"10","author":"Lavee","year":"2007","journal-title":"Heart Surg Forum"},{"key":"2026092807170433300_euag080-B5","doi-asserted-by":"crossref","first-page":"2322","DOI":"10.1016\/j.hrthm.2025.02.017","article-title":"Dose-dependent ventricular lesion formation using a novel large-area pulsed field ablation catheter: a preclinical feasibility study","volume":"22","author":"Kueffer","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B6","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1146\/annurev-biophys-052118-115451","article-title":"Membrane electroporation and electropermeabilization: mechanisms and models","volume":"48","author":"Kotnik","year":"2019","journal-title":"Annu Rev Biophys"},{"key":"2026092807170433300_euag080-B7","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1016\/j.hroo.2024.11.025","article-title":"Intracardiac electrogram analysis may allow for prediction of lesion transmurality after pulsed field ablation of atria in a porcine model","volume":"6","author":"\u0160tublar","year":"2025","journal-title":"Heart Rhythm O2"},{"key":"2026092807170433300_euag080-B8","doi-asserted-by":"crossref","first-page":"e011131","DOI":"10.1161\/CIRCEP.122.011131","article-title":"Reversible and irreversible effects of electroporation on contractility and calcium homeostasis in isolated cardiac ventricular myocytes","volume":"15","author":"Chaigne","year":"2022","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B9","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1111\/j.1749-6632.1994.tb30444.x","article-title":"Effects of strong electrical shock on cardiac muscle tissue","volume":"720","author":"Tung","year":"1994","journal-title":"Ann N Y Acad Sci"},{"key":"2026092807170433300_euag080-B10","doi-asserted-by":"crossref","first-page":"ytac361","DOI":"10.1093\/ehjcr\/ytac361","article-title":"Catheter ablation induced phrenic nerve palsy by pulsed field ablation\u2014completely impossible? A case series","volume":"6","author":"Pansera","year":"2022","journal-title":"Eur Heart J Case Rep"},{"key":"2026092807170433300_euag080-B11","doi-asserted-by":"crossref","first-page":"e010127","DOI":"10.1161\/CIRCEP.121.010127","article-title":"Characterization of phrenic nerve response to pulsed field ablation","volume":"15","author":"Howard","year":"2022","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B12","doi-asserted-by":"crossref","first-page":"108588","DOI":"10.1016\/j.bioelechem.2023.108588","article-title":"Cellular excitability and ns-pulsed electric fields: potential involvement of lipid oxidation in the action potential activation","volume":"155","author":"Rems","year":"2024","journal-title":"Bioelectrochemistry"},{"key":"2026092807170433300_euag080-B13","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.jacep.2020.10.004","article-title":"Reversible atrioventricular conduction impairment following bipolar nanosecond electroporation of the interventricular septum","volume":"7","author":"van Zyl","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B14","doi-asserted-by":"crossref","first-page":"1682","DOI":"10.1016\/j.hrthm.2024.09.023","article-title":"Unexpected transient atrioventricular block and slow junctional rhythm using pulsed field ablation for slow pathway modification: excited or cautious for ablators","volume":"22","author":"Shen","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B15","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1007\/s10439-020-02462-8","article-title":"Dynamics of cell death after conventional IRE and H-FIRE treatments","volume":"48","author":"Mercadal","year":"2020","journal-title":"Ann Biomed Eng"},{"key":"2026092807170433300_euag080-B16","doi-asserted-by":"crossref","first-page":"1618","DOI":"10.1016\/j.jacep.2021.08.016","article-title":"Coronary spasm during pulsed field ablation of the mitral isthmus line","volume":"7","author":"Gunawardene","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B17","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1186\/s12984-018-0390-y","article-title":"Mechanisms of electrical vasoconstriction","volume":"15","author":"Brinton","year":"2018","journal-title":"J Neuroeng Rehabil"},{"key":"2026092807170433300_euag080-B18","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.jconrel.2018.02.032","article-title":"Increased permeability of blood vessels after reversible electroporation is facilitated by alterations in endothelial cell-to-cell junctions","volume":"276","author":"Markelc","year":"2018","journal-title":"J Control Release"},{"key":"2026092807170433300_euag080-B19","doi-asserted-by":"crossref","first-page":"32063","DOI":"10.1038\/s41598-024-83683-y","article-title":"Biophysics and electrophysiology of pulsed field ablation in normal and infarcted porcine cardiac ventricular tissue","volume":"14","author":"Miklav\u010di\u010d","year":"2024","journal-title":"Sci Rep"},{"key":"2026092807170433300_euag080-B20","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1111\/pace.15154","article-title":"Lesion formation in cardiac pulsed-field ablation: acute to chronic cellular level changes","volume":"49","author":"Garrott","year":"2026","journal-title":"Pacing Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B21","doi-asserted-by":"crossref","first-page":"e012723","DOI":"10.1161\/CIRCEP.123.012723","article-title":"Impact of contact force on pulsed field ablation outcomes using focal point catheter","volume":"17","author":"Younis","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B22","doi-asserted-by":"crossref","first-page":"euaf035","DOI":"10.1093\/europace\/euaf035","article-title":"Thermal side effects during pulsed field ablation: an analysis using computer modelling","volume":"27","author":"Mercado-Montoya","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B23","doi-asserted-by":"crossref","first-page":"e010086","DOI":"10.1161\/CIRCEP.121.010086","article-title":"Primer on pulsed electrical field ablation: understanding the benefits and limitations","volume":"14","author":"Verma","year":"2021","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B24","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1111\/jce.14980","article-title":"Safety and chronic lesion characterization of pulsed field ablation in a porcine model","volume":"32","author":"Stewart","year":"2021","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026092807170433300_euag080-B25","doi-asserted-by":"crossref","first-page":"euad257","DOI":"10.1093\/europace\/euad257","article-title":"Determinants of acute irreversible electroporation lesion characteristics after pulsed field ablation: the role of voltage, contact, and adipose interference","volume":"25","author":"Gasperetti","year":"2023","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B26","doi-asserted-by":"crossref","first-page":"euae220","DOI":"10.1093\/europace\/euae220","article-title":"Application repetition and electrode\u2013tissue contact result in deeper lesions using a pulsed-field ablation circular variable loop catheter","volume":"26","author":"Di Biase","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B27","first-page":"39","article-title":"Local changes in membrane potential intensify neutrophil oxidative burst","volume":"29","author":"Simcic","year":"1997","journal-title":"Physiol Chem Phys Med NMR"},{"key":"2026092807170433300_euag080-B28","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/j.abb.2007.12.009","article-title":"Nanosecond pulse electric field (nanopulse): a novel non-ligand agonist for platelet activation","volume":"471","author":"Zhang","year":"2008","journal-title":"Arch Biochem Biophys"},{"key":"2026092807170433300_euag080-B29","doi-asserted-by":"crossref","first-page":"1747","DOI":"10.1016\/j.jacep.2025.04.017","article-title":"NEMESIS-PFA: investigating collateral tissue injury associated with pulsed field ablation","volume":"11","author":"Lakkireddy","year":"2025","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B30","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1186\/s40001-025-02964-y","article-title":"A comparative analysis of postprocedural troponin levels and the impact of renal impairment in patients undergoing pulmonary vein isolation: pulsed field ablation vs. radiofrequency ablation","volume":"30","author":"Feickert","year":"2025","journal-title":"Eur J Med Res"},{"key":"2026092807170433300_euag080-B31","doi-asserted-by":"crossref","first-page":"e003684","DOI":"10.1136\/openhrt-2025-003684","article-title":"Intravascular haemolysis following pulsed field ablation pulmonary vein isolation for atrial fibrillation: a systematic review","volume":"12","author":"Koh","year":"2025","journal-title":"Open Heart"},{"key":"2026092807170433300_euag080-B32","first-page":"1688","article-title":"Cardiac biomarker temporal dynamics after radiofrequency and pulsed field catheter ablation of atrial fibrillation","volume":"6","author":"Casella","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B33","doi-asserted-by":"crossref","first-page":"329","DOI":"10.3390\/bioengineering12040329","article-title":"Pulsed field ablation: a review of preclinical and clinical studies","volume":"12","author":"Sullivan","year":"2025","journal-title":"Bioengineering (Basel)"},{"key":"2026092807170433300_euag080-B34","doi-asserted-by":"crossref","first-page":"1786","DOI":"10.1016\/j.jacep.2023.04.002","article-title":"A focal ablation catheter toggling between radiofrequency and pulsed field energy to treat atrial fibrillation","volume":"9","author":"Reddy","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B35","doi-asserted-by":"crossref","first-page":"e013143","DOI":"10.1161\/CIRCEP.124.013143","article-title":"Effect of sequential, colocalized radiofrequency and pulsed field ablation on cardiac lesion size and histology","volume":"18","author":"Verma","year":"2025","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B36","doi-asserted-by":"crossref","first-page":"euaf174","DOI":"10.1093\/europace\/euaf174","article-title":"Dual energy for pulmonary vein isolation using focal ablation technology integrated with a three-dimensional mapping system: smartfIRE 12-month results","volume":"27","author":"De Potter","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B37","doi-asserted-by":"crossref","first-page":"47497","DOI":"10.31083\/RCM47497","article-title":"Advent of pulsed field ablation for atrial fibrillation: state-of-the-art review","volume":"26","author":"Ha","year":"2025","journal-title":"Rev Cardiovasc Med"},{"key":"2026092807170433300_euag080-B38","doi-asserted-by":"crossref","first-page":"euaf294","DOI":"10.1093\/europace\/euaf294","article-title":"Pulsed field ablation for atrial fibrillation ablation: a European Heart Rhythm Association survey","volume":"27","author":"Bergonti","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B39","doi-asserted-by":"crossref","first-page":"2458","DOI":"10.1093\/eurheartj\/ehad250","article-title":"A worldwide survey on incidence, management, and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: the POTTER-AF study","volume":"44","author":"Tilz","year":"2023","journal-title":"Eur Heart J"},{"key":"2026092807170433300_euag080-B40","doi-asserted-by":"crossref","first-page":"euae038","DOI":"10.1093\/europace\/euae038","article-title":"Pulmonary vein narrowing after pulsed field versus thermal ablation","volume":"26","author":"Mansour","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B41","doi-asserted-by":"crossref","first-page":"1660","DOI":"10.1056\/NEJMoa2307291","article-title":"Pulsed field or conventional thermal ablation for paroxysmal atrial fibrillation","volume":"389","author":"Reddy","year":"2023","journal-title":"N Engl J Med"},{"key":"2026092807170433300_euag080-B42","doi-asserted-by":"crossref","first-page":"1497","DOI":"10.1056\/NEJMoa2502280","article-title":"Pulsed field or cryoballoon ablation for paroxysmal atrial fibrillation","volume":"392","author":"Reichlin","year":"2025","journal-title":"N Engl J Med"},{"key":"2026092807170433300_euag080-B43","first-page":"1664","article-title":"Pulsed field ablation for persistent atrial fibrillation: 1-year results of ADVANTAGE AF","volume":"85","author":"Reddy","year":"2025","journal-title":"J Am Coll Cardiol"},{"key":"2026092807170433300_euag080-B44","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1161\/CIRCULATIONAHA.125.074485","article-title":"Pulsed field ablation of persistent atrial fibrillation with continuous electrocardiographic monitoring follow-up: ADVANTAGE AF phase 2","volume":"152","author":"Reddy","year":"2025","journal-title":"Circulation"},{"key":"2026092807170433300_euag080-B45","doi-asserted-by":"crossref","first-page":"2303","DOI":"10.1038\/s41591-024-03022-6","article-title":"Dual-energy lattice-tip ablation system for persistent atrial fibrillation: a randomized trial","volume":"30","author":"Anter","year":"2024","journal-title":"Nat Med"},{"key":"2026092807170433300_euag080-B46","doi-asserted-by":"crossref","first-page":"euae043","DOI":"10.1093\/europace\/euae043","article-title":"2024 European Heart Rhythm Association\/Heart Rhythm Society\/Asia Pacific Heart Rhythm Society\/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"26","author":"Tzeis","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B47","doi-asserted-by":"crossref","first-page":"euaf012","DOI":"10.1093\/europace\/euaf012","article-title":"Repeat procedures after pulsed field ablation for atrial fibrillation: MANIFEST-REDO study","volume":"27","author":"Scherr","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B48","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1016\/j.jacep.2023.11.026","article-title":"Durability of pulmonary vein isolation using pulsed-field ablation: results from the multicenter EU-PORIA registry","volume":"10","author":"Kueffer","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B49","doi-asserted-by":"crossref","first-page":"euad335","DOI":"10.1093\/europace\/euad335","article-title":"Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review","volume":"25","author":"Serban","year":"2023","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B50","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1093\/europace\/euac211","article-title":"Findings from repeat ablation using high-density mapping after pulmonary vein isolation with pulsed field ablation","volume":"25","author":"Tohoku","year":"2023","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B51","doi-asserted-by":"crossref","first-page":"e014102","DOI":"10.1161\/CIRCEP.125.014102","article-title":"Lesion durability using a circular pulsed field ablation catheter and novel mapping-navigation system","volume":"18","author":"Verma","year":"2025","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B52","doi-asserted-by":"crossref","first-page":"euaf072","DOI":"10.1093\/europace\/euaf072","article-title":"Safety and effectiveness of the first balloon-in-basket pulsed field ablation system for the treatment of atrial fibrillation: VOLT CE mark study 6-month results","volume":"27","author":"Tilz","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B53","doi-asserted-by":"crossref","first-page":"e1214","DOI":"10.1016\/j.hrthm.2025.08.035","article-title":"Ablation in persistent atrial fibrillation: high long-term success with pulsed field ablation using a strict protocol","volume":"22","author":"Chorin","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B54","doi-asserted-by":"crossref","first-page":"euae160","DOI":"10.1093\/europace\/euae160","article-title":"Superior vena cava isolation using a pentaspline pulsed-field ablation catheter: feasibility and safety in patients undergoing atrial fibrillation catheter ablation","volume":"26","author":"Ollitrault","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B55","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1016\/j.jacep.2024.11.009","article-title":"Results of ICE-guided isolation of the superior vena cava with pulsed field ablation","volume":"11","author":"Pierucci","year":"2025","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B56","doi-asserted-by":"crossref","first-page":"euae039","DOI":"10.1093\/europace\/euae039","article-title":"Role of electroanatomical mapping\u2013guided superior vena cava isolation in paroxysmal atrial fibrillation patients without provoked superior vena cava triggers: a randomized controlled study","volume":"26","author":"Dong","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B57","doi-asserted-by":"crossref","first-page":"1625","DOI":"10.1007\/s10840-025-02079-8","article-title":"One-year outcomes of focal pulsed-field ablation for redo procedures in atrial fibrillation and atypical flutter","volume":"68","author":"Weyand","year":"2025","journal-title":"J Interv Card Electrophysiol"},{"key":"2026092807170433300_euag080-B58","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.hroo.2024.03.012","article-title":"Pulsed-field ablation for repeat procedures after failed prior thermal ablation for atrial fibrillation","volume":"5","author":"Maurhofer","year":"2024","journal-title":"Heart Rhythm O2"},{"key":"2026092807170433300_euag080-B59","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/j.jacc.2019.04.021","article-title":"Pulsed field ablation for pulmonary vein isolation in atrial fibrillation","volume":"74","author":"Reddy","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"2026092807170433300_euag080-B60","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1016\/j.jacep.2021.02.014","article-title":"Pulsed field ablation of paroxysmal atrial fibrillation: 1-year outcomes of IMPULSE, PEFCAT, and PEFCAT II","volume":"7","author":"Reddy","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B61","doi-asserted-by":"crossref","first-page":"euad222","DOI":"10.1093\/europace\/euad222","article-title":"Deep sedation protocol during atrial fibrillation ablation using a novel variable-loop biphasic pulsed field ablation catheter","volume":"25","author":"Grimaldi","year":"2023","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B62","doi-asserted-by":"crossref","first-page":"euad230","DOI":"10.1093\/europace\/euad230","article-title":"Sedation strategies for pulsed-field ablation of atrial fibrillation: focus on deep sedation with intravenous ketamine in spontaneous respiration","volume":"25","author":"Iacopino","year":"2023","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B63","doi-asserted-by":"crossref","first-page":"euae270","DOI":"10.1093\/europace\/euae270","article-title":"General anaesthesia and deep sedation for monopolar pulsed field ablation using a lattice-tip catheter combined with a novel three-dimensional mapping system","volume":"26","author":"Rillig","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B64","doi-asserted-by":"crossref","first-page":"e96","DOI":"10.1016\/j.hrthm.2025.09.033","article-title":"Patient-reported outcomes of deep sedation during pulsed field ablation for atrial fibrillation with a novel variable-loop catheter","volume":"23","author":"Sciacca","year":"2026","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B65","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1093\/europace\/euac050","article-title":"Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF)","volume":"24","author":"Ekanem","year":"2022","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B66","doi-asserted-by":"crossref","first-page":"2039","DOI":"10.1093\/europace\/euab154","article-title":"Worldwide sedation strategies for atrial fibrillation ablation: current status and evolution over the last decade","volume":"23","author":"Garcia","year":"2021","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B67","doi-asserted-by":"crossref","first-page":"euae301","DOI":"10.1093\/europace\/euae301","article-title":"Comparative analysis of anaesthesia modalities in pulmonary vein isolation: insights from a prospective multicentre registry","volume":"27","author":"Massalha","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B68","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1007\/s10840-025-02134-4","article-title":"Circular over-the-wire pulsed field ablation for atrial fibrillation: differences in outcomes between conscious sedation or general anesthesia","volume":"69","author":"Van der Graaf","year":"2025","journal-title":"J Interv Card Electrophysiol"},{"key":"2026092807170433300_euag080-B69","doi-asserted-by":"crossref","first-page":"e033210","DOI":"10.1161\/JAHA.123.033210","article-title":"Comparison of the feasibility and safety of a deep sedation protocol for pulmonary vein isolation with pulsed field ablation, cryoballoon ablation, and radiofrequency ablation","volume":"13","author":"Galuszka","year":"2024","journal-title":"J Am Heart Assoc"},{"key":"2026092807170433300_euag080-B70","doi-asserted-by":"crossref","first-page":"euaf287","DOI":"10.1093\/europace\/euaf287","article-title":"Characterization of sedation strategies in real-world use of pulsed field ablation sub-analysis of the EU-PORIA registry","author":"Chun","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B71","doi-asserted-by":"crossref","first-page":"e25","DOI":"10.15420\/aer.2025.28","article-title":"Anaesthesia for pulsed field ablation procedures","volume":"14","author":"Heeger","year":"2025","journal-title":"Arrhythm Electrophysiol Rev"},{"key":"2026092807170433300_euag080-B72","first-page":"e014386","article-title":"Preprocedural multimodality imaging in atrial fibrillation","volume":"15","author":"Quintana","year":"2022","journal-title":"Circ Cardiovasc Imaging"},{"key":"2026092807170433300_euag080-B73","doi-asserted-by":"crossref","first-page":"959186","DOI":"10.3389\/fcvm.2022.959186","article-title":"Initial experience with pulsed field ablation for atrial fibrillation","volume":"9","author":"Magni","year":"2022","journal-title":"Front Cardiovasc Med"},{"key":"2026092807170433300_euag080-B74","doi-asserted-by":"crossref","first-page":"euae075","DOI":"10.1093\/europace\/euae075","article-title":"Role of 3D electro-anatomical mapping on procedural characteristics and outcomes in pulsed-field ablation for atrial fibrillation","volume":"26","author":"Badertscher","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B75","doi-asserted-by":"crossref","first-page":"1374","DOI":"10.1002\/joa3.13180","article-title":"Investigating the role of electroanatomical mapping in single-shot pulsed field catheter ablation","volume":"40","author":"Kariki","year":"2024","journal-title":"J Arrhythmia"},{"key":"2026092807170433300_euag080-B76","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1016\/j.hrthm.2023.05.026","article-title":"Impact of a standardized pacing protocol on end point verification and first pass isolation using a multipolar pulsed-field ablation catheter for pulmonary vein isolation","volume":"20","author":"Badertscher","year":"2023","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B77","doi-asserted-by":"crossref","first-page":"1929","DOI":"10.1007\/s10840-022-01445-0","article-title":"Pulsed field ablation-based pulmonary vein isolation in atrial fibrillation patients with cardiac implantable electronic devices: practical approach and device interrogation (PFA in CIEDs)","volume":"66","author":"Chen","year":"2023","journal-title":"J Interv Card Electrophysiol"},{"key":"2026092807170433300_euag080-B78","first-page":"S1547-5271(25)02920-0","article-title":"Cardiac implantable electronic device software reset and damage after pulsed field ablation using a monopolar lattice-tip catheter","author":"Nair","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B79","first-page":"S1547-5271(25)03013-9","article-title":"Asynchronous pulse field ablation-induced ventricular fibrillation","author":"Goldar","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B80","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1056\/NEJMoa2408308","article-title":"Left atrial appendage closure after ablation for atrial fibrillation","volume":"392","author":"Wazni","year":"2025","journal-title":"N Engl J Med"},{"key":"2026092807170433300_euag080-B81","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.1161\/CIRCULATIONAHA.125.077469","article-title":"Short-term anticoagulation versus dual antiplatelet therapy for preventing device thrombosis following left atrial appendage closure: the ANDES randomized clinical trial","volume":"152","author":"Rod\u00e9s-Cabau","year":"2025","journal-title":"Circulation"},{"key":"2026092807170433300_euag080-B82","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/j.jacep.2024.09.025","article-title":"Safety and feasibility of pulsed-field ablation in patients with mechanical prosthetic valves","volume":"11","author":"Scacciavillani","year":"2025","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B83","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.1111\/jce.15893","article-title":"Ultrasound guidance for femoral venous access in patients undergoing pulmonary vein isolation: a quasi-randomized study","volume":"34","author":"Kupo","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026092807170433300_euag080-B84","doi-asserted-by":"crossref","first-page":"e011547","DOI":"10.1161\/CIRCEP.122.011547","article-title":"Bronchial safety after pulsed field ablation for paroxysmal atrial fibrillation","volume":"16","author":"F\u00fcting","year":"2023","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B85","doi-asserted-by":"crossref","first-page":"1500","DOI":"10.1093\/europace\/euad060","article-title":"Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the faradrive sheath","volume":"25","author":"Kueffer","year":"2023","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B86","doi-asserted-by":"crossref","first-page":"2393","DOI":"10.1111\/jce.16089","article-title":"Quantitative assessment of transient autonomic modulation after single-shot pulmonary vein isolation with pulsed-field ablation","volume":"34","author":"Del Monte","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026092807170433300_euag080-B87","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1016\/j.hrthm.2024.01.040","article-title":"Pulsed field ablation of the right superior pulmonary vein prevents vagal responses via anterior right ganglionated plexus modulation","volume":"21","author":"Del Monte","year":"2024","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B88","doi-asserted-by":"crossref","first-page":"e51","DOI":"10.1016\/j.hrthm.2025.01.022","article-title":"Clinical importance of tissue proximity indication during pulsed field ablation for atrial fibrillation: insights from initial experience","volume":"22","author":"Saito","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B89","doi-asserted-by":"crossref","first-page":"1375","DOI":"10.1016\/j.hrthm.2024.11.031","article-title":"Pulsed field ablation for atrial fibrillation with a novel simplified protocol: the PFA dose study","volume":"22","author":"Badertscher","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B90","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1001\/jamacardio.2025.3687","article-title":"Intracardiac vs transesophageal echocardiography in atrial fibrillation ablation: a randomized clinical trial","volume":"10","author":"Hu","year":"2025","journal-title":"JAMA Cardiol"},{"key":"2026092807170433300_euag080-B91","doi-asserted-by":"crossref","first-page":"2278","DOI":"10.1161\/CIRCULATIONAHA.117.031343","article-title":"Use of intracardiac echocardiography in interventional cardiology: working with the anatomy rather than fighting it","volume":"137","author":"Enriquez","year":"2018","journal-title":"Circulation"},{"key":"2026092807170433300_euag080-B92","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1111\/jce.14367","article-title":"The use of intracardiac echocardiography catheters in endocardial ablation of cardiac arrhythmia: meta-analysis of efficiency, effectiveness, and safety outcomes","volume":"31","author":"Goya","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026092807170433300_euag080-B93","doi-asserted-by":"crossref","first-page":"1244","DOI":"10.1016\/j.jacc.2019.11.067","article-title":"Role of intracardiac echocardiography for catheter ablation of atrial fibrillation: reduction of complications and mortality","volume":"75","author":"Ren","year":"2020","journal-title":"J Am Coll Cardiol"},{"key":"2026092807170433300_euag080-B94","doi-asserted-by":"crossref","first-page":"e875","DOI":"10.1016\/j.hrthm.2025.05.045","article-title":"Ensuring catheter-tissue contact with intracardiac echocardiography during pulsed-field ablation improves procedure outcome in patients with atrial fibrillation","volume":"22","author":"Mohanty","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B95","doi-asserted-by":"crossref","first-page":"1240","DOI":"10.1016\/j.hrthm.2024.03.1808","article-title":"Interference from lobe-and-disk left atrial appendage occluder affecting left superior pulmonary vein pulsed field ablation","volume":"21","author":"Audiat","year":"2024","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B96","doi-asserted-by":"crossref","first-page":"e013208","DOI":"10.1161\/CIRCEP.124.013208","article-title":"Lesion morphometry of the pentaspline pulsed field ablation catheter: understanding catheter pose, rotation, and dosing","volume":"17","author":"Watanabe","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B97","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1016\/j.jacep.2024.03.024","article-title":"Severe periprocedural complications after ablation for atrial fibrillation: an international collaborative individual patient data registry","volume":"10","author":"du Fay de Lavallaz","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B98","doi-asserted-by":"crossref","first-page":"euae180","DOI":"10.1093\/europace\/euae180","article-title":"Incidence of acute pericarditis after pulsed-field ablation for the treatment of atrial fibrillation","volume":"26","author":"Isenegger","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B99","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1161\/CIRCULATIONAHA.123.064959","article-title":"Safety and effectiveness of pulsed field ablation to treat atrial fibrillation: one-year outcomes from the MANIFEST-PF registry","volume":"148","author":"Turagam","year":"2023","journal-title":"Circulation"},{"key":"2026092807170433300_euag080-B100","doi-asserted-by":"crossref","first-page":"1422","DOI":"10.1161\/CIRCULATIONAHA.123.063988","article-title":"Pulsed field ablation for the treatment of atrial fibrillation: PULSED AF pivotal trial","volume":"147","author":"Verma","year":"2023","journal-title":"Circulation"},{"key":"2026092807170433300_euag080-B101","doi-asserted-by":"crossref","first-page":"1248","DOI":"10.1016\/j.hrthm.2024.04.046","article-title":"Acute kidney injury after catheter ablation of atrial fibrillation: comparison between different energy sources","volume":"21","author":"Jordan","year":"2024","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B102","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/j.jacep.2023.12.008","article-title":"Acute kidney injury resulting from hemoglobinuria after pulsed-field ablation in atrial fibrillation: is it preventable?","volume":"10","author":"Mohanty","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B103","doi-asserted-by":"crossref","first-page":"euad371","DOI":"10.1093\/europace\/euad371","article-title":"Severe acute kidney injury related to haemolysis after pulsed field ablation for atrial fibrillation","volume":"26","author":"Venier","year":"2023","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B104","doi-asserted-by":"crossref","first-page":"1808","DOI":"10.1161\/CIRCULATIONAHA.122.061497","article-title":"Coronary arterial spasm during pulsed field ablation to treat atrial fibrillation","volume":"146","author":"Reddy","year":"2022","journal-title":"Circulation"},{"key":"2026092807170433300_euag080-B105","doi-asserted-by":"crossref","first-page":"euae105","DOI":"10.1093\/europace\/euae105","article-title":"Venous vascular closure system vs. Figure-of-eight suture following atrial fibrillation ablation: the STYLE-AF study","volume":"26","author":"Tilz","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B106","doi-asserted-by":"crossref","first-page":"euae083","DOI":"10.1093\/europace\/euae083","article-title":"Same-day discharge after atrial fibrillation ablation under a nurse-coordinated standardized protocol","volume":"26","author":"Espinosa","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B107","doi-asserted-by":"crossref","first-page":"euaf270","DOI":"10.1093\/europace\/euaf270","article-title":"Procedural characteristics and clinical outcomes from same-day discharge after pulsed field ablation treatment for atrial fibrillation: an admIRE trial sub-analysis","volume":"27","author":"Di Biase","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B108","doi-asserted-by":"crossref","first-page":"euae200","DOI":"10.1093\/europace\/euae200","article-title":"Same-day discharge vs. overnight stay following catheter ablation for atrial fibrillation: a comprehensive review and meta-analysis by the European Heart Rhythm Association Health Economics Committee","volume":"26","author":"Zylla","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B109","first-page":"1527","article-title":"Pulsed field vs radiofrequency ablation for paroxysmal atrial fibrillation: the BEAT PAROX-AF trial","volume":"47","author":"Jais","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B110","doi-asserted-by":"crossref","first-page":"euaf179","DOI":"10.1093\/europace\/euaf179","article-title":"Pulsed-field ablation vs. thermal ablation for paroxysmal atrial fibrillation: a systematic review and meta-analysis of randomized controlled trials","volume":"27","author":"Badertscher","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B111","doi-asserted-by":"crossref","first-page":"e011780","DOI":"10.1161\/CIRCEP.122.011780","article-title":"Paroxysmal atrial fibrillation ablation using a novel Variable-loop biphasic pulsed field ablation catheter integrated with a 3-dimensional mapping system: 1-year outcomes of the multicenter inspIRE study","volume":"16","author":"Duytschaever","year":"2023","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B112","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1161\/CIRCULATIONAHA.124.070333","article-title":"Pulsed field ablation to treat paroxysmal atrial fibrillation: safety and effectiveness in the AdmIRE pivotal trial","volume":"150","author":"Reddy","year":"2024","journal-title":"Circulation"},{"key":"2026092807170433300_euag080-B113","doi-asserted-by":"crossref","first-page":"2524","DOI":"10.1016\/j.hrthm.2025.04.037","article-title":"Safety and effectiveness of a novel balloon-in-basket pulsed-field ablation catheter for the treatment of paroxysmal and persistent AF: volt-AF IDE trial acute results","volume":"22","author":"Lo","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B114","doi-asserted-by":"crossref","first-page":"e012732","DOI":"10.1161\/CIRCEP.124.012732","article-title":"Characterization and clinical significance of hemolysis after pulsed field ablation for atrial fibrillation: results of a multicenter analysis","volume":"17","author":"Popa","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B115","doi-asserted-by":"crossref","first-page":"euae251","DOI":"10.1093\/europace\/euae251","article-title":"Intravascular haemolysis and acute kidney injury following atrial fibrillation ablation: a report using two different systems for pulsed field ablation","volume":"26","author":"De Smet","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B116","doi-asserted-by":"crossref","first-page":"2551","DOI":"10.1016\/j.hrthm.2025.04.031","article-title":"One-year outcomes of a conformable single-shot pulsed-field ablation catheter for the treatment of paroxysmal atrial fibrillation","volume":"22","author":"Reddy","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B117","doi-asserted-by":"crossref","first-page":"euad185","DOI":"10.1093\/europace\/euad185","article-title":"EUropean real-world outcomes with pulsed field ablatiOn in patients with symptomatic atRIAl fibrillation: lessons from the multi-centre EU-PORIA registry","volume":"25","author":"Schmidt","year":"2023","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B118","doi-asserted-by":"crossref","first-page":"2020","DOI":"10.1038\/s41591-024-03114-3","article-title":"Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study","volume":"30","author":"Ekanem","year":"2024","journal-title":"Nat Med"},{"key":"2026092807170433300_euag080-B119","doi-asserted-by":"crossref","first-page":"euaf182","DOI":"10.1093\/europace\/euaf182","article-title":"Real-world experience with the pentaspline pulsed field ablation system: one-year outcomes of the FARADISE registry","volume":"27","author":"Boersma","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B120","doi-asserted-by":"crossref","first-page":"e70158","DOI":"10.1002\/joa3.70158","article-title":"Pulsed-field ablation versus radiofrequency ablation for paroxysmal atrial fibrillation: a systematic review and meta-analysis","volume":"41","author":"Martins Esteves","year":"2025","journal-title":"J Arrhythmia"},{"key":"2026092807170433300_euag080-B121","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1016\/j.hrthm.2024.06.036","article-title":"Prevalence, timing, and impact of early recurrence of atrial tachyarrhythmias after pulsed field ablation: a secondary analysis of the PULSED AF trial","volume":"22","author":"Boersma","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B122","doi-asserted-by":"crossref","first-page":"euaf007","DOI":"10.1093\/europace\/euaf007","article-title":"Early versus late atrial fibrillation recurrence after pulsed field ablation: insights from the admIRE trial","volume":"27","author":"Di Biase","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B123","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1016\/j.hrthm.2024.08.011","article-title":"Redefining the blanking period after pulsed field ablation in patients with atrial fibrillation","volume":"22","author":"Mohanty","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B124","doi-asserted-by":"crossref","first-page":"euaf157","DOI":"10.1093\/europace\/euaf157","article-title":"Pulsed field ablation compared to thermal ablation techniques in atrial fibrillation: a German-wide in-hospital safety analysis","volume":"27","author":"Maier","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B125","doi-asserted-by":"crossref","first-page":"euaf185","DOI":"10.1093\/europace\/euaf185","article-title":"Incidence of laboratory-defined severe intravascular haemolysis across commercially available pulsed field ablation technologies for atrial fibrillation","volume":"27","author":"Mountantonakis","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B126","doi-asserted-by":"crossref","first-page":"euaf210","DOI":"10.1093\/europace\/euaf210","article-title":"Haemolysis and myocardial and neural injury after monopolar pulsed field ablation using a novel lattice-tip catheter to treat atrial fibrillation","volume":"27","author":"Gold","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B127","doi-asserted-by":"crossref","first-page":"euag005","DOI":"10.1093\/europace\/euag005","article-title":"Impact of saline irrigation on haemolysis, silent cerebral lesion incidence, thermal dynamics, and bubble formation in pulsed field ablation with a variable-loop circular catheter","volume":"28","author":"Zhou","year":"2026","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B128","doi-asserted-by":"crossref","first-page":"1864","DOI":"10.1016\/j.hrthm.2025.03.1978","article-title":"Diffuse right coronary artery spasm occurring 45 min after pulsed field ablation for atrial fibrillation","volume":"22","author":"Luther","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B129","doi-asserted-by":"crossref","first-page":"1478","DOI":"10.1016\/j.jacep.2025.03.014","article-title":"Effect of pulsed-field ablation on human coronary arteries: a longitudinal study with intracoronary imaging","volume":"11","author":"Tam","year":"2025","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B130","doi-asserted-by":"crossref","first-page":"euaf133","DOI":"10.1093\/europace\/euaf133","article-title":"Esophageal endoscopic findings after pulmonary vein and posterior wall isolation using pulsed field ablation: results from the Eso-PFA study","volume":"27","author":"Gunawardene","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B131","doi-asserted-by":"crossref","first-page":"2394","DOI":"10.1016\/j.jacep.2025.06.036","article-title":"Pulsed-field ablation of atrial flutter: insights from a large volume U. S. Center","volume":"11","author":"Demian","year":"2025","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B132","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.jacep.2023.09.026","article-title":"Pericarditis after catheter ablation for atrial fibrillation","volume":"10","author":"Yadav","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B133","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.hroo.2022.02.008","article-title":"Acute pericarditis after atrial fibrillation ablation: incidence, characteristics, and risk factors","volume":"3","author":"Nakhla","year":"2022","journal-title":"Heart Rhythm O2"},{"key":"2026092807170433300_euag080-B134","article-title":"Left atrial function after atrial fibrillation ablation with pulsed field vs radiofrequency energy: a comparative study","author":"Verhaeghe","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B135","doi-asserted-by":"crossref","first-page":"1767","DOI":"10.1093\/europace\/euab155","article-title":"Pulsed field ablation prevents chronic atrial fibrotic changes and restrictive mechanics after catheter ablation for atrial fibrillation","volume":"23","author":"Nakatani","year":"2021","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B136","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1016\/j.hrthm.2024.03.005","article-title":"Pulsed field ablation prevents left atrial restrictive physiology after posterior wall isolation in patients with persistent atrial fibrillation","volume":"21","author":"Banai","year":"2024","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B137","doi-asserted-by":"crossref","first-page":"1823","DOI":"10.1007\/s10840-025-02080-1","article-title":"Pulsed-field ablation beyond pulmonary vein for persistent atrial fibrillation: efficacy and impact on left atrial function","volume":"68","author":"Zaher","year":"2025","journal-title":"J Interv Card Electrophysiol"},{"key":"2026092807170433300_euag080-B138","doi-asserted-by":"crossref","first-page":"2782","DOI":"10.1111\/jce.14241","article-title":"Extensive left atrial ablation was associated with exacerbation of left atrial stiffness and dyspnea","volume":"30","author":"Moon","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026092807170433300_euag080-B139","doi-asserted-by":"crossref","first-page":"2104","DOI":"10.1161\/CIRCULATIONAHA.113.003862","article-title":"In-hospital complications associated with catheter ablation of atrial fibrillation in the United States between 2000 and 2010","volume":"128","author":"Deshmukh","year":"2013","journal-title":"Circulation"},{"key":"2026092807170433300_euag080-B140","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.hrthm.2025.04.008","article-title":"Incidence of silent cerebral events detected by MRI in patients with atrial fibrillation undergoing pulsed field ablation vs thermal ablation: a systematic review and network meta-analysis","volume":"10","author":"Hu","year":"2026","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B141","doi-asserted-by":"crossref","DOI":"10.1016\/j.jacep.2025.12.018","article-title":"Cerebrovascular ischemic lesions after pulsed field ablation for atrial fibrillation using Variable-loop ablation catheter","author":"Laskov","year":"2026","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B142","doi-asserted-by":"crossref","first-page":"2254","DOI":"10.1016\/j.jacc.2019.08.1036","article-title":"Risk of mortality following catheter ablation of atrial fibrillation","volume":"74","author":"Cheng","year":"2019","journal-title":"JACC"},{"key":"2026092807170433300_euag080-B143","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1161\/CIRCULATIONAHA.125.077983","article-title":"Life-threatening delayed myocardial ischemia and malignant arrhythmias occurring after pulsed field ablation of atrial fibrillation","volume":"153","author":"Gunawardene","year":"2026","journal-title":"Circulation"},{"key":"2026092807170433300_euag080-B144","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1016\/j.jacep.2022.10.028","article-title":"Pulsed field ablation to treat atrial fibrillation: autonomic nervous system effects","volume":"9","author":"Musikantow","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B145","doi-asserted-by":"crossref","first-page":"1634","DOI":"10.1016\/j.jacep.2024.05.005","article-title":"Autonomic effects of pulsed field vs thermal ablation for treating atrial fibrillation: subanalysis of ADVENT","volume":"10","author":"Gerstenfeld","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B146","doi-asserted-by":"crossref","first-page":"1864","DOI":"10.1016\/j.jacep.2023.05.035","article-title":"Impact of pulsed-field ablation on intrinsic cardiac autonomic nervous system after pulmonary vein isolation","volume":"9","author":"Tohoku","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B147","doi-asserted-by":"crossref","first-page":"e013977","DOI":"10.1161\/CIRCEP.125.013977","article-title":"2025 international expert practical guide on the use of the pentaspline pulsed field ablation system in atrial fibrillation ablation procedures","volume":"18","author":"Chen","year":"2025","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B148","doi-asserted-by":"crossref","first-page":"e010817","DOI":"10.1161\/CIRCEP.121.010817","article-title":"5S study: safe and simple single shot pulmonary vein isolation with pulsed field ablation using sedation","volume":"15","author":"Schmidt","year":"2022","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B149","doi-asserted-by":"crossref","first-page":"1837","DOI":"10.1007\/s10840-023-01495-y","article-title":"Pulsed field ablation in real-world atrial fibrillation patients: clinical recurrence, operator learning curve and re-do procedural findings","volume":"66","author":"Ruwald","year":"2023","journal-title":"J Interv Card Electrophysiol"},{"key":"2026092807170433300_euag080-B150","doi-asserted-by":"crossref","first-page":"2127","DOI":"10.1007\/s10840-024-01835-6","article-title":"National workflow experience with pulsed field ablation for atrial fibrillation: learning curve, efficiency, and safety","volume":"67","author":"Bisignani","year":"2024","journal-title":"J Interv Card Electrophysiol"},{"key":"2026092807170433300_euag080-B151","doi-asserted-by":"crossref","first-page":"2019","DOI":"10.1111\/jce.16056","article-title":"Comparison of pulsed field ablation and cryoballoon ablation for pulmonary vein isolation","volume":"34","author":"Schipper","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026092807170433300_euag080-B152","doi-asserted-by":"crossref","first-page":"euae243","DOI":"10.1093\/europace\/euae243","article-title":"2024 updated European Heart Rhythm Association core curriculum for physicians and allied professionals: a statement of the European Heart Rhythm Association of the European Society of Cardiology","volume":"26","author":"Trines","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B153","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1007\/s10840-023-01570-4","article-title":"Focal pulsed field ablation and ultrahigh-density mapping\u2014versatile tools for all atrial arrhythmias? Initial procedural experiences","volume":"67","author":"Ruwald","year":"2024","journal-title":"J Interv Card Electrophysiol"},{"key":"2026092807170433300_euag080-B154","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.hrthm.2025.07.001","article-title":"Ablation of cavotricuspid isthmus-dependent atrial flutter using a focal monopolar pulsed-field ablation catheter: feasibility, periprocedural coronary spasms and conduction disorders","volume":"23","author":"Farnir","year":"2026","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B155","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1007\/s10840-022-01215-y","article-title":"Innovations in atrial fibrillation ablation","volume":"66","author":"Kim","year":"2023","journal-title":"J Interv Card Electrophysiol"},{"key":"2026092807170433300_euag080-B156","doi-asserted-by":"crossref","first-page":"euaf171","DOI":"10.1093\/europace\/euaf171","article-title":"Comparative study of nanosecond and microsecond pulsed field ablation for pulmonary vein isolation in preclinical models","volume":"27","author":"Xie","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B157","doi-asserted-by":"crossref","first-page":"e13","DOI":"10.1016\/j.hrthm.2024.12.021","article-title":"A novel focal lattice-tip catheter toggling between pulsed field energy and radiofrequency for atrial arrhythmia ablation: results from a real-world, multicenter registry","volume":"22","author":"Vetta","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B158","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1007\/s10840-025-01980-6","article-title":"An approach to electroanatomical mapping with a pentaspline pulsed field catheter to guide atrial fibrillation ablation","volume":"68","author":"Mills","year":"2025","journal-title":"J Interv Card Electrophysiol"},{"key":"2026092807170433300_euag080-B159","article-title":"Learning curve and procedural efficiency of zero-fluoroscopy pulsed-field ablation for atrial fibrillation","author":"P\u00e9rez-Pinz\u00f3n","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B160","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1016\/j.hrthm.2024.09.061","article-title":"In vivo assessment of catheter-tissue contact using tissue proximity indication and its impact on cardiac lesion formation in pulsed field ablation","volume":"22","author":"Okumura","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B161","doi-asserted-by":"crossref","first-page":"euaf234","DOI":"10.1093\/europace\/euaf234","article-title":"Acute durability of cavotricuspid isthmus block after pulsed electric field ablation: randomized comparison of two pentaspline catheter configurations (SECTION trial)","volume":"27","author":"Stojadinovi\u0107","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B162","doi-asserted-by":"crossref","first-page":"e1193","DOI":"10.1016\/j.hrthm.2025.06.006","article-title":"Pulsed field ablation with a pentaspline catheter for ventricular arrhythmias: first US series","volume":"22","author":"Younis","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B163","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1016\/j.hroo.2024.04.011","article-title":"Posterior wall ablation for persistent atrial fibrillation: very-high-power short-duration versus standard-power radiofrequency ablation","volume":"5","author":"Compagnucci","year":"2024","journal-title":"Heart Rhythm O2"},{"key":"2026092807170433300_euag080-B164","doi-asserted-by":"crossref","first-page":"1526","DOI":"10.1016\/j.hrthm.2024.05.042","article-title":"Pulsed field vs very high-power short-duration radiofrequency ablation for atrial fibrillation: results of a multicenter, real-world experience","volume":"21","author":"Dello Russo","year":"2024","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B165","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1016\/j.jacep.2024.04.003","article-title":"Direct epicardial validation of posterior wall electroporation in persistent atrial fibrillation","volume":"10","author":"Solimene","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B166","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1111\/jce.16246","article-title":"Pulsed field ablation technology for pulmonary vein and left atrial posterior wall isolation in patients with persistent atrial fibrillation","volume":"35","author":"Schiavone","year":"2024","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2026092807170433300_euag080-B167","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1016\/j.hrthm.2024.04.102","article-title":"AF ablation using a novel \u201csingle-shot\u201d map-and-ablate spherical array pulsed field ablation catheter: 1-year outcomes of the first-in-human PULSE-EU trial","volume":"21","author":"Turagam","year":"2024","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B168","doi-asserted-by":"crossref","first-page":"900","DOI":"10.1016\/j.jacep.2024.01.017","article-title":"Impact of left atrial posterior wall ablation during pulsed-field ablation for persistent atrial fibrillation","volume":"10","author":"Turagam","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B169","doi-asserted-by":"crossref","first-page":"103865","DOI":"10.1016\/j.jaccas.2025.103865","article-title":"Successful pulsed-field ablation of superior vena cava fibrillation using a circular multielectrode array catheter","volume":"30","author":"Nozoe","year":"2025","journal-title":"JACC Case Rep"},{"key":"2026092807170433300_euag080-B170","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.jacep.2020.03.004","article-title":"Characterization of complex atrial tachycardia in patients with previous atrial interventions using high-resolution mapping","volume":"6","author":"Derval","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B171","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/j.hrthm.2023.01.009","article-title":"Anterior mitral line in patients with persistent atrial fibrillation and anterior scar: a multicenter matched comparison-the MiLine study","volume":"20","author":"Bergonti","year":"2023","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B172","doi-asserted-by":"crossref","first-page":"1292","DOI":"10.1016\/j.jacep.2019.08.014","article-title":"Septal versus lateral mitral isthmus ablation for treatment of mitral annular flutter","volume":"5","author":"Maheshwari","year":"2019","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B173","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1007\/s10840-021-00943-x","article-title":"Ablation of mitral annular flutter ablation utilizing a left atrial anterior line versus a lateral mitral isthmus line: a systematic review and meta-analysis","volume":"63","author":"Aldaas","year":"2022","journal-title":"J Interv Card Electrophysiol"},{"key":"2026092807170433300_euag080-B174","doi-asserted-by":"crossref","first-page":"1252","DOI":"10.1093\/europace\/euaa137","article-title":"Acute and mid-term outcome of ethanol infusion of vein of Marshall for the treatment of perimitral flutter","volume":"22","author":"Takigawa","year":"2020","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B175","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1001\/jamacardio.2023.4405","article-title":"Coronary artery spasm during pulsed field vs radiofrequency catheter ablation of the mitral isthmus","volume":"9","author":"Zhang","year":"2024","journal-title":"JAMA Cardiol"},{"key":"2026092807170433300_euag080-B176","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1016\/j.jacep.2023.03.021","article-title":"Pulsed-field ablation on mitral isthmus in persistent atrial fibrillation: preliminary data on efficacy and safety","volume":"9","author":"Davong","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B177","doi-asserted-by":"crossref","first-page":"e012426","DOI":"10.1161\/CIRCEP.123.012426","article-title":"Efficacy of intravenous nitrates for the prevention of coronary artery spasm during pulsed field ablation of the mitral isthmus","volume":"17","author":"Men\u00e8","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B178","doi-asserted-by":"crossref","first-page":"e014026","DOI":"10.1161\/CIRCEP.125.014026","article-title":"Feasibility and safety of pulsed field ablation for coronary sinus and left atrial appendage isolation and mitral isthmus ablation: acute and chronic findings","volume":"18","author":"La Fazia","year":"2025","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B179","doi-asserted-by":"crossref","first-page":"euaf265","DOI":"10.1093\/europace\/euaf265","article-title":"Anterior mitral isthmus line using pulsed-field ablation with the pentaspline catheter or radiofrequency ablation: procedural characteristics, safety, and mid-term outcomes","volume":"17","author":"Br\u00fcgger","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B180","doi-asserted-by":"crossref","first-page":"e40","DOI":"10.1016\/j.hrthm.2024.11.023","article-title":"Feasibility of atrial linear ablation using a lattice tip catheter that toggles between radiofrequency and pulsed-field energy under deep sedation","volume":"22","author":"Hirokami","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B181","doi-asserted-by":"crossref","first-page":"1957","DOI":"10.1016\/j.hrthm.2025.01.015","article-title":"A tailored substrate-based approach using focal pulsed field catheter ablation in patients with atrial fibrillation and advanced atrial substrate: procedural data and 6-month success rates","volume":"22","author":"Farnir","year":"2025","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B182","doi-asserted-by":"crossref","first-page":"2394","DOI":"10.1016\/j.jacep.2025.06.036","article-title":"Pulsed-field ablation of atrial flutter: insights from a large volume U.S. Center","volume":"11","author":"Demian","year":"2025","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B183","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1016\/j.jacep.2022.11.027","article-title":"Transient inferior ST-segment elevation and ventricular fibrillation after cavotricuspid isthmus pulsed-field ablation","volume":"9","author":"Della Rocca","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B184","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.jacep.2023.12.015","article-title":"Nitroglycerin to ameliorate coronary artery spasm during focal pulsed-field ablation for atrial fibrillation","volume":"10","author":"Malyshev","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B185","doi-asserted-by":"crossref","first-page":"e012826","DOI":"10.1161\/CIRCEP.124.012826","article-title":"Focal pulsed field ablation for premature ventricular contractions: a multicenter experience","volume":"17","author":"Della Rocca","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B186","doi-asserted-by":"crossref","first-page":"euae192","DOI":"10.1093\/europace\/euae192","article-title":"Efficacy and safety of focal pulsed-field ablation for ventricular arrhythmias: two-centre experience","volume":"26","author":"Peichl","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B187","doi-asserted-by":"crossref","first-page":"euae193","DOI":"10.1093\/europace\/euae193","article-title":"A large footprint focal catheter toggling between pulsed field and radiofrequency energy: first clinical experience for ventricular tachycardia ablation","volume":"26","author":"Pannone","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B188","doi-asserted-by":"crossref","first-page":"euae275","DOI":"10.1093\/europace\/euae275","article-title":"Mapping and ablation of ventricular tachycardia using dual-energy lattice-tip focal catheter: early feasibility and safety study","volume":"26","author":"Peichl","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B189","doi-asserted-by":"crossref","first-page":"euaf139","DOI":"10.1093\/europace\/euaf139","article-title":"Safety and efficacy of a lattice-tip catheter for ventricular arrhythmia ablation: the AFFERA Ventricular Arrhythmia Ablation Registry (AVAAR)","volume":"27","author":"Sacher","year":"2025","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B190","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.hrthm.2025.02.014","article-title":"Feasibility and midterm effectiveness of focal pulsed field ablation for ventricular arrhythmias","volume":"23","author":"Ruwald","year":"2026","journal-title":"Heart Rhythm"},{"key":"2026092807170433300_euag080-B191","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1161\/CIRCULATIONAHA.125.077025","article-title":"High-voltage focal pulsed field ablation to treat scar-related ventricular tachycardia: the first-in-human VCAS trial","volume":"152","author":"Reddy","year":"2025","journal-title":"Circulation"},{"key":"2026092807170433300_euag080-B192","doi-asserted-by":"crossref","first-page":"e013206","DOI":"10.1161\/CIRCEP.124.013206","article-title":"Pulsed field ablation of paroxysmal supraventricular tachycardia: a prospective multicenter single-arm study in China","volume":"17","author":"Li","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2026092807170433300_euag080-B193","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.jacep.2023.08.030","article-title":"The safety and feasibility of pulsed-field ablation in atrioventricular nodal re-entrant tachycardia: first-in-human pilot trial","volume":"10","author":"Zeng","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"2026092807170433300_euag080-B194","doi-asserted-by":"crossref","first-page":"euae134","DOI":"10.1093\/europace\/euae134","article-title":"State-of-the-art pulsed field ablation for cardiac arrhythmias: ongoing evolution and future perspective","volume":"26","author":"Chun","year":"2024","journal-title":"Europace"},{"key":"2026092807170433300_euag080-B195","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1097\/HCO.0000000000001183","article-title":"Cardiac selectivity in pulsed field ablation","volume":"40","author":"Meng","year":"2025","journal-title":"Curr Opin Cardiol"},{"key":"2026092807170433300_euag080-B196","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1016\/j.hrthm.2024.05.032","article-title":"Cost, efficiency, and outcomes of pulsed field ablation vs thermal ablation for atrial fibrillation: a real-world study","volume":"21","author":"Calvert","year":"2024","journal-title":"Heart Rhythm"}],"container-title":["Europace"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/europace\/advance-article-pdf\/doi\/10.1093\/europace\/euag080\/68031172\/euag080.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/europace\/article-pdf\/28\/6\/euag080\/68031172\/euag080.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/europace\/article-pdf\/28\/6\/euag080\/68031172\/euag080.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T11:17:32Z","timestamp":1790594252000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/doi\/10.1093\/europace\/euag080\/8651392"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,12]]},"references-count":196,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,6,2]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/euag080","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,6]]},"published":{"date-parts":[[2026,4,12]]},"article-number":"euag080"}}