{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T20:19:24Z","timestamp":1769026764514,"version":"3.49.0"},"reference-count":25,"publisher":"Oxford University Press (OUP)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,3]]},"DOI":"10.1093\/europace\/eus339","type":"journal-article","created":{"date-parts":[[2012,11,2]],"date-time":"2012-11-02T01:11:54Z","timestamp":1351818714000},"page":"402-408","source":"Crossref","is-referenced-by-count":23,"title":["Detection of high incidence of Riata lead breaches by systematic postero-anterior and lateral chest X-ray in a large cohort"],"prefix":"10.1093","volume":"15","author":[{"given":"Christian","family":"Steinberg","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Fran\u00e7ois","family":"Sarrazin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fran\u00e7ois","family":"Philippon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marc-Andr\u00e9","family":"Bouchard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gilles","family":"O'Hara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Franck","family":"Molin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isabelle","family":"Nault","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Louis","family":"Blier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean","family":"Champagne","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2012,11,1]]},"reference":[{"key":"key\n\t\t\t\t20170624063820_EUS339C1","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1016\/j.hrthm.2008.03.008","article-title":"Implantable cardioverter-defibrillator lead disintegration at the level of the tricuspid valve","volume":"5","author":"Duray","year":"2008","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t20170624063820_EUS339C2","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1093\/europace\/euq082","article-title":"Late failure of a single-coil transvenous implantable cardioverter-defibrillator lead associated with conductor separation","volume":"12","author":"Richards","year":"2010","journal-title":"Europace"},{"key":"key\n\t\t\t\t20170624063820_EUS339C3","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1016\/j.hrthm.2009.11.007","article-title":"Unusual failure of a multilumen, small-diameter implantable cardioverter-defibrillator lead","volume":"7","author":"Jalal","year":"2010","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t20170624063820_EUS339C4","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1111\/j.1540-8167.2011.02042.x","article-title":"Premature failure of a Riata defibrillator lead without impedance change or inappropriate sensing: a case report and review of the literature","volume":"22","author":"Krebsbach","year":"2011","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t20170624063820_EUS339C5","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1111\/j.1540-8159.2009.02664.x","article-title":"Insulation damage in a shock wire: an unexpected fluoroscopic image","volume":"33","author":"Valk","year":"2010","journal-title":"Pacing Clin Electrophysiol"},{"key":"key\n\t\t\t\t20170624063820_EUS339C6","doi-asserted-by":"crossref","first-page":"1018","DOI":"10.1111\/j.1540-8167.2011.02055.x","article-title":"Insulation defects of thin high-voltage ICD leads: an underestimated problem?","volume":"22","author":"Erkapic","year":"2011","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t20170624063820_EUS339C7","volume-title":"Important Product Information: St Jude Medical Riata and Riata ST Silicone Endocardial Leads","author":"Chester","year":"2010"},{"key":"key\n\t\t\t\t20170624063820_EUS339C8","volume-title":"Medical Device advisory","author":"Carlson","year":"2011"},{"key":"key\n\t\t\t\t20170624063820_EUS339C9","author":"Parkash","year":"2011"},{"key":"key\n\t\t\t\t20170624063820_EUS339C10","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1016\/j.hrthm.2011.12.019","article-title":"Riata implantable cardioverter-defibrillator lead failure: analysis of explanted leads with a unique insulation defect","volume":"9","author":"Hauser","year":"2012","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t20170624063820_EUS339C11","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1111\/j.1540-8167.2009.01651.x","article-title":"Clinical performance of the St. Jude Medical Riata defibrillation lead in a large patient population","volume":"21","author":"Porterfield","year":"2010","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t20170624063820_EUS339C12","article-title":"Prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata(R) and Riata(R) ST implantable cardioverter-defibrillator leads","author":"Schmutz","year":"2012","journal-title":"Int J Cardiol"},{"key":"key\n\t\t\t\t20170624063820_EUS339C13","doi-asserted-by":"crossref","DOI":"10.1111\/j.1540-8167.2012.02378.x","article-title":"Prevalence and Predictors of Cable Extrusion and Loss of Electrical Integrity with the Riata Defibrillator Lead","author":"Shen","year":"2012","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t20170624063820_EUS339C14","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1016\/j.hrthm.2012.03.049","article-title":"High prevalence of insulation failure with externalized cables in St. Jude Medical Riata Family ICD Leads; Fluoroscopic Grading Scale and correlation to extracted leads","volume":"9","author":"Parvathaneni","year":"2012","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t20170624063820_EUS339C15","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1161\/CIRCEP.112.973081","article-title":"Fluoroscopic screening of asymptomatic patients implanted with the recalled Riata Lead Family","volume":"5","author":"Liu","year":"2012","journal-title":"Circ Arrhythm Electrophiol"},{"key":"key\n\t\t\t\t20170624063820_EUS339C16","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1016\/j.hrthm.2012.03.048","article-title":"Deaths caused by the failure of Riata and Riata ST implantable cardioverter-defibrillator leads","volume":"8","author":"Hauser","year":"2012","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t20170624063820_EUS339C17","author":"Parkash","year":"2012"},{"key":"key\n\t\t\t\t20170624063820_EUS339C18","doi-asserted-by":"crossref","first-page":"2384","DOI":"10.1161\/CIRCULATIONAHA.109.924357","article-title":"Complications associated with revision of Sprint Fidelis leads: report from the Canadian Heart Rhythm Society Device Advisory Committee","volume":"121","author":"Parkash","year":"2010","journal-title":"Circulation"},{"key":"key\n\t\t\t\t20170624063820_EUS339C19","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2012.08.006","article-title":"Long-term electrical survival analysis of Riata and Riata ST Silicone Leads \u2013 National VA Experience","author":"Sung","year":"2012","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t20170624063820_EUS339C20","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2012.06.015","article-title":"Independent Multicenter Study of Riata and Riata ST ICD Leads","author":"Abdelhadi","year":"2012","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t20170624063820_EUS339C21"},{"key":"key\n\t\t\t\t20170624063820_EUS339C22"},{"key":"key\n\t\t\t\t20170624063820_EUS339C23","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1007\/s00399-012-0186-x","article-title":"Recommendations of the Working Group of Arrhythmias of the German Society of Cardiology on the approach to patients with Riata\u00ae and Riata ST\u00ae leads (St. Jude Medical): Nucleus of the Working Group of Arrhythmias of the German Society of Cardiology]","volume":"23","author":"Israel","year":"2012","journal-title":"Herzschrittmacherther Elektrophysiol"},{"key":"key\n\t\t\t\t20170624063820_EUS339C24","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1097\/HCO.0b013e32834dc366","article-title":"The values of defibrillation testing at implantable cardioverter defibrillator implantation: \u2018and then there were none","volume":"27","author":"Gasparini","year":"2012","journal-title":"Curr Opin Cardiol"},{"key":"key\n\t\t\t\t20170624063820_EUS339C25","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1111\/j.1540-8159.2010.02917.x","article-title":"Utility of postoperative testing of implantable cardioverter-defibrillators","volume":"34","author":"Sauer","year":"2011","journal-title":"Pacing Clin Electrophysiol"}],"container-title":["EP Europace"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/europace\/article-pdf\/15\/3\/402\/17860804\/eus339.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,15]],"date-time":"2020-07-15T11:28:26Z","timestamp":1594812506000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article-lookup\/doi\/10.1093\/europace\/eus339"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,11,1]]},"references-count":25,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2012,11,1]]},"published-print":{"date-parts":[[2013,3]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/eus339","relation":{},"ISSN":["1532-2092","1099-5129"],"issn-type":[{"value":"1532-2092","type":"electronic"},{"value":"1099-5129","type":"print"}],"subject":[],"published":{"date-parts":[[2012,11,1]]}}}