{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T11:07:14Z","timestamp":1791976034231,"version":"4.4.0"},"reference-count":16,"publisher":"Oxford University Press (OUP)","issue":"9","funder":[{"DOI":"10.13039\/501100000024","name":"Canadian Institutes of Health Research","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000024","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,9,1]]},"DOI":"10.1093\/europace\/euw276","type":"journal-article","created":{"date-parts":[[2017,3,17]],"date-time":"2017-03-17T03:46:16Z","timestamp":1489722376000},"page":"1514-1520","source":"Crossref","is-referenced-by-count":19,"title":["Implantation of cardiac resynchronization therapy devices using three leads by cephalic vein dissection approach"],"prefix":"10.1093","volume":"19","author":[{"given":"Alexios","family":"Hadjis","sequence":"first","affiliation":[{"name":"McGill University Health Centre, 1650 Cedar Avenue, Room E5-200, Montreal, Quebec H3G 1A4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Riccardo","family":"Proietti","sequence":"additional","affiliation":[{"name":"Cardiology Department, Luigi Sacco Hospital, Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vidal","family":"Essebag","sequence":"additional","affiliation":[{"name":"McGill University Health Centre, 1650 Cedar Avenue, Room E5-200, Montreal, Quebec H3G 1A4, Canada"},{"name":"H\u00f4pital Sacr\u00e9-Coeur de Montr\u00e9al, Montreal, Quebec, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2017,3,17]]},"reference":[{"key":"key\n\t\t\t\t20180222002116_euw276C1","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1007\/s10840-005-5845-y","article-title":"Novel steerable telescoping catheter system for implantation of left ventricular pacing leads","volume":"12","author":"Geske","year":"2005","journal-title":"J Interv Card Electrophysiol"},{"key":"key\n\t\t\t\t20180222002116_euw276C2","first-page":"178","article-title":"Techniques of implantation of a biventricular pacing system","volume":"3","author":"Kappos","year":"2008","journal-title":"Hosp Chron"},{"key":"key\n\t\t\t\t20180222002116_euw276C3","doi-asserted-by":"crossref","first-page":"1664","DOI":"10.1093\/europace\/eut345","article-title":"Preferred tools and techniques for implantation of cardiac electronic devices in Europe: results of the European Heart Rhythm Association survey","volume":"15","author":"Bongiorni","year":"2013","journal-title":"Europace"},{"key":"key\n\t\t\t\t20180222002116_euw276C4","doi-asserted-by":"crossref","first-page":"57","DOI":"10.2478\/amma-2014-0013","article-title":"Implantation of biventricular cardiac devices using a double venous approach \u2014 an alternative implantation technique","volume":"60","author":"\u015eo\u015fdean","year":"2014","journal-title":"Acta Med Marisiensis"},{"key":"key\n\t\t\t\t20180222002116_euw276C5","first-page":"101","article-title":"Pneumothorax resulting from subclavian puncture: a complication of permanent pacemaker lead implantation","volume":"12","author":"Res","year":"2004","journal-title":"Neth Heart J"},{"key":"key\n\t\t\t\t20180222002116_euw276C6","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1111\/j.1540-8159.1999.tb00531.x","article-title":"The cephalic vein cutdown versus subclavian puncture for pacemaker\/ICD lead implantation","volume":"22","author":"Parsonnet","year":"1999","journal-title":"Pacing Clin Electrophysiol"},{"key":"key\n\t\t\t\t20180222002116_euw276C7","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.cjca.2012.10.006","article-title":"Canadian Cardiovascular Society guidelines on the use of cardiac resynchronization therapy: evidence and patient selection","volume":"29","author":"Exner","year":"2013","journal-title":"Can J Cardiol"},{"issue":"(11 Pt 2)","key":"key\n\t\t\t\t20180222002116_euw276C8","doi-asserted-by":"crossref","first-page":"1974","DOI":"10.1111\/j.1540-8159.1994.tb03783.x","article-title":"Four chamber pacing in dilated cardiomyopathy","volume":"17","author":"Cazeau","year":"1994","journal-title":"Pacing Clin Electrophysiol"},{"key":"key\n\t\t\t\t20180222002116_euw276C9","doi-asserted-by":"crossref","first-page":"2502","DOI":"10.1001\/jama.297.22.2502","article-title":"Cardiac resynchronization therapy for patients with left ventricular systolic dysfunction: a systematic review","volume":"297","author":"McAlister","year":"2007","journal-title":"JAMA"},{"key":"key\n\t\t\t\t20180222002116_euw276C10","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1016\/j.hrthm.2005.04.005","article-title":"Simplified cardiac resynchronization implantation technique involving right access and a triple-guide\/single introducer approach","volume":"2","author":"Romeyer-Bouchard","year":"2005","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t20180222002116_euw276C11","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1111\/j.1540-8159.2010.02975.x","article-title":"Safety and feasibility of cephalic venous access for cardiac resynchronization device implantation","volume":"34","author":"Ussen","year":"2011","journal-title":"Pacing Clin Electrophysiol"},{"key":"key\n\t\t\t\t20180222002116_euw276C12","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1016\/j.jacc.2011.06.007","article-title":"Implantation-related complications of implantable cardioverter-defibrillators and cardiac resynchronization therapy devices: a systematic review of randomized clinical trials","volume":"58","author":"van Rees","year":"2011","journal-title":"J Am Coll Cardiol"},{"key":"key\n\t\t\t\t20180222002116_euw276C13","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1093\/europace\/eus054","article-title":"Pneumothorax in cardiac pacing: a population-based cohort study of 28,860 Danish patients","volume":"14","author":"Kirkfeldt","year":"2012","journal-title":"Europace"},{"key":"key\n\t\t\t\t20180222002116_euw276C14","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1016\/j.cjca.2015.02.021","article-title":"A novel method of axillary venipuncture using the cephalic vein as a sole anatomic landmark","volume":"31","author":"Imnadze","year":"2015","journal-title":"Can J Cardiol"},{"key":"key\n\t\t\t\t20180222002116_euw276C15","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1161\/CIRCULATIONAHA.111.053744","article-title":"Clinical predictors of Fidelis lead failure: report from the Canadian Heart Rhythm Society Device Committee","volume":"125","author":"Birnie","year":"2012","journal-title":"Circulation"},{"key":"key\n\t\t\t\t20180222002116_euw276C16","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/j.amjcard.2012.03.015","article-title":"Predictors of fluoroscopy time and procedural failure during biventricular device implantation","volume":"110","author":"Hsu","year":"2012","journal-title":"Am J Cardiol"}],"container-title":["EP Europace"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/europace\/article-pdf\/19\/9\/1514\/24119978\/euw276.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,19]],"date-time":"2019-09-19T17:43:18Z","timestamp":1568914998000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/19\/9\/1514\/3073886"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,17]]},"references-count":16,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2017,3,17]]},"published-print":{"date-parts":[[2017,9,1]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/euw276","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2017,9]]},"published":{"date-parts":[[2017,3,17]]}}}