{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T13:36:00Z","timestamp":1768829760974,"version":"3.49.0"},"reference-count":21,"publisher":"Oxford University Press (OUP)","issue":"FI_3","license":[{"start":{"date-parts":[[2017,8,9]],"date-time":"2017-08-09T00:00:00Z","timestamp":1502236800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"funder":[{"DOI":"10.13039\/100007497","name":"Biosense Webster, Inc.","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100007497","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Janssen, Medtronic, Boston Sci, St. Jude Med"},{"name":"Medtronic, St. Jude Medical"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,11,1]]},"DOI":"10.1093\/europace\/eux264","type":"journal-article","created":{"date-parts":[[2017,8,9]],"date-time":"2017-08-09T07:29:20Z","timestamp":1502263760000},"page":"f392-f400","source":"Crossref","is-referenced-by-count":41,"title":["Safety and efficiency of porous-tip contact-force catheter for drug-refractory symptomatic paroxysmal atrial fibrillation ablation: results from the SMART SF trial"],"prefix":"10.1093","volume":"20","author":[{"given":"Larry A","family":"Chinitz","sequence":"first","affiliation":[{"name":"NYU Langone Medical Center, New York University, 550 First Avenue, New York, NY, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel P","family":"Melby","sequence":"additional","affiliation":[{"name":"Abbott Northwestern Hospital, Minneapolis, MN, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francis E","family":"Marchlinski","sequence":"additional","affiliation":[{"name":"University of Pennsylvania, Philadelphia, PA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Craig","family":"Delaughter","sequence":"additional","affiliation":[{"name":"HeartPlace, Bedford, TX, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert S","family":"Fishel","sequence":"additional","affiliation":[{"name":"Florida Electrophysiology Associates, Atlantis, FL, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George","family":"Monir","sequence":"additional","affiliation":[{"name":"Florida Hospital Cardiovascular Institute, Orlando, FL, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anshul M","family":"Patel","sequence":"additional","affiliation":[{"name":"Emory St Joseph\u2019s Hospital, Atlanta, GA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Douglas N","family":"Gibson","sequence":"additional","affiliation":[{"name":"Scripps Clinic, San Diego, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles A","family":"Athill","sequence":"additional","affiliation":[{"name":"San Diego Cardiac Center, San Diego, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lee","family":"Ming Boo","sequence":"additional","affiliation":[{"name":"Biosense Webster Inc., Diamond Bar, California, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Stagg","sequence":"additional","affiliation":[{"name":"Biosense Webster Inc., Diamond Bar, California, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"Natale","sequence":"additional","affiliation":[{"name":"Texas Cardiac Arrhythmia Research Foundation, Austin, TX, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2017,8,9]]},"reference":[{"key":"key\n\t\t\t\t2018120305155382800_eux264-B1","doi-asserted-by":"crossref","first-page":"1822","DOI":"10.1056\/NEJMp020134","article-title":"Atrial fibrillation\u2014rhythm or rate control","volume":"347","author":"Cain","year":"2002","journal-title":"N Engl J Med"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B2","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/j.jacc.2010.10.001","article-title":"2011 ACCF\/AHA\/HRS focused update on the management of patients with atrial fibrillation (Updating the 2006 Guideline). A report of the American College of Cardiology Foundation\/American Heart Association Task Force on Practice Guidelines","volume":"57","author":"Wann","year":"2011","journal-title":". J Am Coll Cardiol"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B3","doi-asserted-by":"crossref","first-page":"10A","DOI":"10.1016\/S0002-9149(97)89114-X","article-title":"Electrophysiologic mechanisms of perpetuation of atrial fibrillation","volume":"77","author":"Allessie","year":"1996","journal-title":"J Am Coll Cardiol"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B4","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1093\/europace\/eus027","article-title":"2012\u2009HRS\/EHRA\/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design","volume":"14","author":"Calkins","year":"2012","journal-title":"Europace"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B5","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1001\/jama.2009.2029","article-title":"Comparison of antiarrhythmic drug therapy and radiofrequency catheter ablation in patients with paroxysmal atrial fibrillation: a randomized controlled trial","volume":"303","author":"Wilber","year":"2010","journal-title":"JAMA"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B6","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/j.jacc.2014.04.072","article-title":"Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF Trial","volume":"64","author":"Natale","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B7","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1093\/europace\/euv206","article-title":"Reduced residual conduction gaps and favourable outcome in contact force-guided circumferential pulmonary vein isolation","volume":"18","author":"Itoh","year":"2016","journal-title":"Europace"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B8","doi-asserted-by":"crossref","first-page":"1919","DOI":"10.1016\/j.hrthm.2014.07.033","article-title":"Pulmonary vein isolation using \u201ccontact force\u201d ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation\u2013a prospective study","volume":"11","author":"Andrade","year":"2014","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B9","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.jacep.2016.07.014","article-title":"Relationship between catheter stability and 12-month success after pulmonary vein isolation: a subanalysis of the SMART-AF trial","volume":"2","author":"Reddy","year":"2016","journal-title":"JACC Clin Electrophysiol"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B10","doi-asserted-by":"crossref","first-page":"852","DOI":"10.1111\/jce.12403","article-title":"Acute safety of an open-irrigated ablation catheter with 56-hole porous tip for radiofrequency ablation of paroxysmal atrial fibrillation: analysis from 2 observational registry studies","volume":"25","author":"Oza","year":"2014","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B11","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1111\/jce.12031","article-title":"Comparison of ThermoCool\u00ae Surround Flow catheter versus ThermoCool\u00ae catheter in achieving persistent electrical isolation of pulmonary veins: a pilot study","volume":"24","author":"Bertaglia","year":"2013","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B12","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1111\/jce.12221","article-title":"Enhanced efficiency of a novel porous tip irrigated RF ablation catheter for pulmonary vein isolation","volume":"24","author":"Park","year":"2013","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B13","doi-asserted-by":"crossref","first-page":"2779","DOI":"10.1161\/STROKEAHA.115.010380","article-title":"National Institutes of Health Stroke Scale Item profiles as predictor of patient outcome: external validation on safe implementation of thrombolysis in stroke-monitoring study data","volume":"46","author":"Abdul-Rahim","year":"2015","journal-title":"Stroke"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B14","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1161\/CIRCEP.109.859116","article-title":"Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation","volume":"3","author":"Cappato","year":"2010","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B15","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1111\/jce.12303","article-title":"Real-time contact force sensing for pulmonary vein isolation in the setting of paroxysmal atrial fibrillation: procedural and 1-year results","volume":"25","author":"Marijon","year":"2014","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B16","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1093\/europace\/euu215","article-title":"Contact-force guided radiofrequency vs. second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation-a prospective evaluation","volume":"17","author":"Jourda","year":"2015","journal-title":"Europace"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B17","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1007\/s10840-015-0056-7","article-title":"Randomized comparison of contact force-guided versus conventional circumferential pulmonary vein isolation of atrial fibrillation: prevalence, characteristics, and predictors of electrical reconnections and clinical outcomes","volume":"44","author":"Nakamura","year":"2015","journal-title":"J Interv Card Electrophysiol"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B18","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1111\/pace.12811","article-title":"Impact of contact force monitoring in acute pulmonary vein isolation using an anatomic approach. A randomized study","volume":"39","author":"Pedrote","year":"2016","journal-title":"Pacing Clin Electrophysiol"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B19","doi-asserted-by":"crossref","first-page":"1761","DOI":"10.1016\/j.hrthm.2016.05.011","article-title":"Randomized trial comparing pulmonary vein isolation using the SmartTouch catheter with or without real-time contact force data","volume":"13","author":"Ullah","year":"2016","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B20","doi-asserted-by":"crossref","first-page":"e004867","DOI":"10.1161\/CIRCEP.116.004867","article-title":"Determinants of acute and late pulmonary vein reconnection in contact force-guided pulmonary vein isolation: identifying the weakest link in the ablation chain","volume":"10","author":"El Haddad","year":"2017","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"key\n\t\t\t\t2018120305155382800_eux264-B21","first-page":"775","article-title":"Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values","volume":"19","author":"Das","year":"2016","journal-title":"Europace"}],"container-title":["EP Europace"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/europace\/article-pdf\/20\/FI_3\/f392\/26947295\/eux264.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,2]],"date-time":"2019-10-02T01:12:48Z","timestamp":1569978768000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/20\/FI_3\/f392\/4079862"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8,9]]},"references-count":21,"journal-issue":{"issue":"FI_3","published-online":{"date-parts":[[2017,8,9]]},"published-print":{"date-parts":[[2018,11,1]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/eux264","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2018,11]]},"published":{"date-parts":[[2017,8,9]]}}}