{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T21:01:49Z","timestamp":1788037309685,"version":"build-2784847793"},"reference-count":55,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2018,12,13]],"date-time":"2018-12-13T00:00:00Z","timestamp":1544659200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,2,1]]},"DOI":"10.1093\/europace\/euy266","type":"journal-article","created":{"date-parts":[[2018,10,11]],"date-time":"2018-10-11T15:12:12Z","timestamp":1539270732000},"page":"239-249","source":"Crossref","is-referenced-by-count":37,"title":["Updated systematic review and meta-analysis of the impact of contact force sensing on the safety and efficacy of atrial fibrillation ablation: discrepancy between observational studies and randomized control trial data"],"prefix":"10.1093","volume":"21","author":[{"given":"Sohaib A","family":"Virk","sequence":"first","affiliation":[{"name":"Department of Cardiology, Westmead Hospital, Sydney, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Ariyaratnam","sequence":"additional","affiliation":[{"name":"University of Manchester, Manchester, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard G","family":"Bennett","sequence":"additional","affiliation":[{"name":"Bristol Heart Institute, Bristol Royal Infirmary, Bristol, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saurabh","family":"Kumar","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Westmead Hospital, Sydney, Australia"},{"name":"Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Hawkesbury Road, Westmead, Sydney, NSW 2145, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2018,12,13]]},"reference":[{"key":"key\n\t\t\t\t2019020703595365600_euy266-B1","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1093\/europace\/eux274","article-title":"2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"20","author":"Calkins","year":"2018","journal-title":"Europace"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B2","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1161\/CIRCULATIONAHA.104.533190","article-title":"Response of atrial fibrillation to pulmonary vein antrum isolation is directly related to resumption and delay of pulmonary vein conduction","volume":"112","author":"Verma","year":"2005","journal-title":"Circulation"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B3","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1161\/CIRCEP.108.803650","article-title":"Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus","volume":"1","author":"Yokoyama","year":"2008","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B4","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1161\/CIRCEP.113.001094","article-title":"Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size","volume":"7","author":"Ikeda","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B5","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1016\/j.hrthm.2013.03.022","article-title":"Predictive value of impedance changes for real-time contact force measurements during catheter ablation of atrial arrhythmias in humans","volume":"10","author":"Kumar","year":"2013","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B6","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1161\/CIRCEP.113.978320","article-title":"Locations of high contact force during left atrial mapping in atrial fibrillation patients: electrogram amplitude and impedance are poor predictors of electrode-tissue contact force for ablation of atrial fibrillation","volume":"6","author":"Nakagawa","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B7","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/j.jacep.2018.03.014","article-title":"Role of contact force sensing in catheter ablation of cardiac arrhythmias: evolution or history repeating itself?","volume":"4","author":"Ariyarathna","year":"2018","journal-title":"JACC Clin Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B8","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.hrthm.2011.08.021","article-title":"A novel radiofrequency ablation catheter using contact force sensing: Toccata study","volume":"9","author":"Kuck","year":"2012","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B9","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/j.jacc.2014.04.072","article-title":"Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial","volume":"64","author":"Natale","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B10","doi-asserted-by":"crossref","first-page":"1990","DOI":"10.1016\/j.hrthm.2015.06.026","article-title":"Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: a systematic review and meta-analysis","volume":"12","author":"Afzal","year":"2015","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B11","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1111\/jce.13264","article-title":"Role of contact force-guided radiofrequency catheter ablation for treatment of atrial fibrillation: a systematic review and meta-analysis","volume":"28","author":"Lin","year":"2017","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B12","doi-asserted-by":"crossref","first-page":"e002476","DOI":"10.1161\/JAHA.115.002476","article-title":"Impact of contact force technology on atrial fibrillation ablation: a meta-analysis","volume":"4","author":"Shurrab","year":"2015","journal-title":"J Am Heart Assoc"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B13","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.2307\/2533446","article-title":"Operating characteristics of a rank correlation test for publication bias","volume":"50","author":"Begg","year":"1994","journal-title":"Biometrics"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B14","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1136\/bmj.315.7109.629","article-title":"Bias in meta-analysis detected by a simple, graphical test","volume":"315","author":"Egger","year":"1997","journal-title":"BMJ"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B15","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1111\/j.0006-341X.2000.00455.x","article-title":"Trim and fill: a simple funnel-plot-based method of testing and adjusting for publication bias in meta-analysis","volume":"56","author":"Duval","year":"2000","journal-title":"Biometrics"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B16","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1080\/14017431.2017.1285043","article-title":"Is the knowledge of contact force beneficial in pulmonary vein antrum isolation?","volume":"51","author":"Borregaard","year":"2017","journal-title":"Scand Cardiovasc J"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B17","doi-asserted-by":"crossref","first-page":"516","DOI":"10.5603\/CJ.a2013.0153","article-title":"Biomarkers of myocardial injury with different energy sources for atrial fibrillation catheter ablation","volume":"21","author":"Casella","year":"2014","journal-title":"Cardiol J"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B18","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.hrthm.2017.10.010","article-title":"Contact force sensing for ablation of persistent atrial fibrillation: a randomized, multicenter trial","volume":"15","author":"Conti","year":"2018","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B19","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1016\/j.hrthm.2014.03.019","article-title":"Comparison of lesion formation between contact force-guided and non-guided circumferential pulmonary vein isolation: a prospective, randomized study","volume":"11","author":"Kimura","year":"2014","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B20","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1007\/s10840-015-0056-7","article-title":"Randomized comparison of contact force-guided versus conventional circumferential pulmonary vein isolation of atrial fibrillation: prevalence, characteristics, and predictors of electrical reconnections and clinical outcomes","volume":"44","author":"Nakamura","year":"2015","journal-title":"J Interv Card Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B21","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1002\/joa3.12054","article-title":"Comparison of the efficacy between impedance-guided and contact force-guided atrial fibrillation ablation using an automated annotation system","volume":"34","author":"Park","year":"2018","journal-title":"J Arrhythm"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B22","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1111\/pace.12811","article-title":"Impact of contact force monitoring in acute pulmonary vein isolation using an anatomic approach. A randomized study","volume":"39","author":"Pedrote","year":"2016","journal-title":"Pacing Clin Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B23","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1161\/CIRCULATIONAHA.114.014092","article-title":"Randomized, controlled trial of the safety and effectiveness of a contact force-sensing irrigated catheter for ablation of paroxysmal atrial fibrillation: results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) study","volume":"132","author":"Reddy","year":"2015","journal-title":"Circulation"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B24","doi-asserted-by":"crossref","first-page":"1761","DOI":"10.1016\/j.hrthm.2016.05.011","article-title":"Randomized trial comparing pulmonary vein isolation using the SmartTouch catheter with or without real-time contact force data","volume":"13","author":"Ullah","year":"2016","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B25","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.ijcard.2014.11.105","article-title":"A prospective study on safety of catheter ablation procedures: contact force guided ablation could reduce the risk of cardiac perforation","volume":"179","author":"Akca","year":"2015","journal-title":"Int J Cardiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B26","doi-asserted-by":"crossref","first-page":"e017970","DOI":"10.1136\/bmjopen-2017-017970","article-title":"Randomised clinical trial of cryoballoon versus irrigated radio frequency catheter ablation for atrial fibrillation\u2014the effect of double short versus standard exposure cryoablation duration during pulmonary vein isolation (CIRCA-DOSE): methods and rationale","volume":"7","author":"Andrade","year":"2017","journal-title":"BMJ Open"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B27","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1007\/s10840-016-0128-3","article-title":"Clinical experience with contact-force and flexible-tip ablation catheter designs","volume":"47","author":"Deubner","year":"2016","journal-title":"J Interv Card Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B28","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.ipej.2015.07.004","article-title":"Pulmonary vein isolation using new technologies to improve ablation lesion formation: initial results comparing enhanced catheter tip irrigation (Surround Flow(\u00ae)) with contact force measurement (Smarttouch(\u00ae))","volume":"15","author":"Fichtner","year":"2015","journal-title":"Indian Pacing Electrophysiol J"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B29","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.1016\/j.ijcard.2012.11.072","article-title":"Contact force sensing technology identifies sites of inadequate contact and reduces acute pulmonary vein reconnection: a prospective case control study","volume":"168","author":"Haldar","year":"2013","journal-title":"Int J Cardiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B30","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1111\/jce.13281","article-title":"Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation","volume":"28","author":"Hussein","year":"2017","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B31","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1093\/europace\/euv206","article-title":"Reduced residual conduction gaps and favourable outcome in contact force-guided circumferential pulmonary vein isolation","volume":"18","author":"Itoh","year":"2016","journal-title":"Europace"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B32","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1111\/jce.12606","article-title":"Relationship between contact force sensing technology and medium-term outcome of atrial fibrillation ablation: a multicenter study of 600 patients","volume":"26","author":"Jarman","year":"2015","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B33","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1093\/europace\/euv186","article-title":"Use of a contact force-sensing ablation catheter with advanced catheter location significantly reduces fluoroscopy time and radiation dose in catheter ablation of atrial fibrillation","volume":"18","author":"Lee","year":"2016","journal-title":"Europace"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B34","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1007\/s00392-015-0855-y","article-title":"Comparison of contact force-guided procedure with non-contact force-guided procedure during left atrial mapping and pulmonary vein isolation: impact of contact force on recurrence of atrial fibrillation","volume":"104","author":"Makimoto","year":"2015","journal-title":"Clin Res Cardiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B35","doi-asserted-by":"crossref","first-page":"317","DOI":"10.4330\/wjc.v8.i4.317","article-title":"Impact of computed tomography image and contact force technology on catheter ablation for atrial fibrillation","volume":"8","author":"Marai","year":"2016","journal-title":"World J Cardiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B36","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1111\/jce.12303","article-title":"Real-time contact force sensing for pulmonary vein isolation in the setting of paroxysmal atrial fibrillation: procedural and 1-year results","volume":"25","author":"Marijon","year":"2014","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B37","doi-asserted-by":"crossref","first-page":"1312","DOI":"10.1111\/j.1540-8159.2012.03503.x","article-title":"Clinical impact of an open-irrigated radiofrequency catheter with direct force measurement on atrial fibrillation ablation","volume":"35","author":"Martinek","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B38","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1111\/jce.13280","article-title":"Three-year outcomes and reconnection patterns after initial contact force guided pulmonary vein isolation for paroxysmal atrial fibrillation","volume":"28","author":"Nair","year":"2017","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B39","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.ipej.2016.06.002","article-title":"Use of the new contact force sensing ablation catheter dramatically reduces fluoroscopy time during atrial fibrillation ablation procedures","volume":"16","author":"Naniwadekar","year":"2016","journal-title":"Indian Pacing Electrophysiol J"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B40","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.hrthm.2016.12.008","article-title":"Contact-force guided single-catheter approach for pulmonary vein isolation: feasibility, outcomes, and cost-effectiveness","volume":"14","author":"Pambrun","year":"2017","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B41","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1111\/jce.13058","article-title":"Radiofrequency ablation of atrial fibrillation: nonrandomized comparison of circular versus point-by-point \u201cSmart\u201d ablation for achieving circumferential pulmonary vein isolation and curing arrhythmic symptoms","volume":"27","author":"Rosso","year":"2016","journal-title":"J Cardiovasc Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B42","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1007\/s00392-018-1228-0","article-title":"Contact force facilitates the achievement of an unexcitable ablation line during pulmonary vein isolation","volume":"107","author":"Schaeffer","year":"2018","journal-title":"Clin Res Cardiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B43","first-page":"193","article-title":"Which is the best catheter to perform atrial fibrillation ablation? A comparison between standard ThermoCool, SmartTouch, and Surround Flow catheters","volume":"39","author":"Sciarra","year":"2014","journal-title":"J Interv Card Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B44","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1111\/pace.12549","article-title":"Optimizing radiofrequency ablation of paroxysmal and persistent atrial fibrillation by direct catheter force measurement-a case-matched comparison in 198 patients","volume":"38","author":"Sigmund","year":"2015","journal-title":"Pacing Clin Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B45","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1111\/pace.12501","article-title":"Comparison of robotic and manual persistent AF ablation using catheter contact force sensing: an international multicenter registry study","volume":"37","author":"Ullah","year":"2014","journal-title":"Pacing Clin Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B46","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1016\/j.hrthm.2017.02.014","article-title":"Reduction in radiation dose for atrial fibrillation ablation over time: a 12-year single-center experience of 2344 patients","volume":"14","author":"Voskoboinik","year":"2017","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B47","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1007\/s00392-013-0625-7","article-title":"Impact of real-time contact force and impedance measurement in pulmonary vein isolation procedures for treatment of atrial fibrillation","volume":"103","author":"Wakili","year":"2014","journal-title":"Clin Res Cardiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B48","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1007\/s10840-015-0006-4","article-title":"Superior efficacy of pulmonary vein isolation with online contact force measurement persists after the learning period: a prospective case control study","volume":"43","author":"Wolf","year":"2015","journal-title":"J Interv Card Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B49","doi-asserted-by":"crossref","first-page":"266","DOI":"10.5114\/aoms.2014.42578","article-title":"Contact force mapping during catheter ablation for atrial fibrillation: procedural data and one-year follow-up","volume":"2","author":"Wutzler","year":"2014","journal-title":"Arch Med Sci"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B50","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s10840-017-0295-x","article-title":"Assessment of autonomic nervous system modulation after novel catheter ablation techniques for atrial fibrillation using multiple short-term electrocardiogram recordings","volume":"51","author":"Yanagisawa","year":"2018","journal-title":"J Interv Card Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B51","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1056\/NEJM199809033391003","article-title":"Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins","volume":"339","author":"Haissaguerre","year":"1998","journal-title":"N Engl J Med"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B52","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1161\/CIRCEP.109.910125","article-title":"Electropathological substrate of long-standing persistent atrial fibrillation in patients with structural heart disease: longitudinal dissociation","volume":"3","author":"Allessie","year":"2010","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B53","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1161\/CIRCEP.110.959429","article-title":"Assessment of catheter tip contact force resulting in cardiac perforation in swine atria using force sensing technology","volume":"4","author":"Perna","year":"2011","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B54","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1016\/j.hrthm.2017.04.024","article-title":"Risk of atrioesophageal fistula formation with contact force-sensing catheters","volume":"14","author":"Black-Maier","year":"2017","journal-title":"Heart Rhythm"},{"key":"key\n\t\t\t\t2019020703595365600_euy266-B55","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1016\/j.hrthm.2017.07.023","article-title":"Safety of catheter ablation of atrial fibrillation using fiber optic-based contact force sensing","volume":"14","author":"Mansour","year":"2017","journal-title":"Heart Rhythm"}],"container-title":["EP Europace"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/europace\/article-pdf\/21\/2\/239\/27715558\/euy266.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,3]],"date-time":"2026-04-03T19:35:24Z","timestamp":1775244924000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/21\/2\/239\/5245326"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,13]]},"references-count":55,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2018,12,13]]},"published-print":{"date-parts":[[2019,2,1]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/euy266","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2019,2]]},"published":{"date-parts":[[2018,12,13]]}}}