{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T14:07:18Z","timestamp":1769090838192,"version":"3.49.0"},"reference-count":26,"publisher":"Oxford University Press (OUP)","issue":"8","license":[{"start":{"date-parts":[[2019,6,6]],"date-time":"2019-06-06T00:00:00Z","timestamp":1559779200000},"content-version":"vor","delay-in-days":1,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Aims<\/jats:title>\n                  <jats:p>The aim of our study was to investigate the long-term efficacy and safety of transseptal endocardial left ventricular lead implantation (TELVLI).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods and results<\/jats:title>\n                  <jats:p>Transseptal endocardial left ventricular lead implantation was performed in 54 patients (44 men, median age 69, New York Heart Association III\u2013IV stage) between 2007 and 2017 in a single centre. In 36 cases, the transseptal puncture (TP) was performed via the femoral vein, and in 18 cases, the TP and also the left ventricular (LV) lead placement were performed via the subclavian vein. An electrophysiological deflectable catheter was used to reach the LV wall through the dilated TP hole. The LV lead implantation was successful in all patients. A total of 54 patients were followed up for a median of 29\u2009months [interquartile range (IQR) 8\u201340\u2009months], the maximum follow-up time was 94\u2009months. Significant improvement in the LV ejection fraction was observed at the 3-month visit, from the median of 27% (IQR 25\u201334%) to 33% (IQR 32\u201344%), P\u2009&lt;\u20090.05. Early lead dislocation was observed in three cases (5%), reposition was performed using the original puncture site in all. The patients were maintained on anticoagulation therapy with a target international normalized ratio between 2.5 and 3.5. Four thromboembolic events were noticed during follow-up. A total of 27 patients died, with a median survival of 15\u2009months (IQR 6\u201340).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>The TELVLI is an effective approach for cardiac resynchronization therapy (CRT) however it is associated with a substantial thromboembolic risk (7%).<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/europace\/euz116","type":"journal-article","created":{"date-parts":[[2019,4,15]],"date-time":"2019-04-15T11:08:36Z","timestamp":1555326516000},"page":"1237-1245","source":"Crossref","is-referenced-by-count":14,"title":["Long-term single-centre large volume experience with transseptal endocardial left ventricular lead implantation"],"prefix":"10.1093","volume":"21","author":[{"given":"L\u00e1szl\u00f3","family":"Gell\u00e9r","sequence":"first","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zolt\u00e1n","family":"Sall\u00f3","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Levente","family":"Moln\u00e1r","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tam\u00e1s","family":"Tahin","sequence":"additional","affiliation":[{"name":"Department of Cardiology, St. Rafael Hospital, Zr\u00ednyi street 1, Zalaegerszeg H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emin Evren","family":"\u00d6zcan","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Faculty of Medicine, Dokuz Eyl\u00fcl University, K\u00fclt\u00fcr Mahallesi, Cumhuriyet Blv No: 144, \u0130zmir, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Valentina","family":"Kutyifa","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"},{"name":"University of Rochester Medical Center, 265 Crittenden Boulevard, Box 653, Rochester, NY, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Istv\u00e1n","family":"Osztheimer","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Szabolcs","family":"Szil\u00e1gyi","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N\u00e1ndor","family":"Szegedi","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P\u00e1l","family":"\u00c1brah\u00e1m","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Astrid","family":"Apor","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Klaudia Vivien","family":"Nagy","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Annam\u00e1ria","family":"Kosztin","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D\u00e1vid","family":"Becker","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Szilvia","family":"Herczeg","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Endre","family":"Zima","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B\u00e9la","family":"Merkely","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Heart and Vascular Center of Semmelweis University, V\u00e1rosmajor street 68, Budapest H, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2019,6,5]]},"reference":[{"key":"2019080504545289800_euz116-B1","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1056\/NEJMoa050496","article-title":"The effect of cardiac resynchronization on morbidity and mortality in heart failure","volume":"352","author":"Cleland","year":"2005","journal-title":"N Engl J Med"},{"key":"2019080504545289800_euz116-B2"},{"key":"2019080504545289800_euz116-B3","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1093\/europace\/eup061","article-title":"In the field of cardiac resynchronization therapy is left ventricular pacing via the coronary sinus a mature technique","volume":"11","author":"Alonso","year":"2009","journal-title":"Europace"},{"key":"2019080504545289800_euz116-B4","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1093\/europace\/eut300","article-title":"Left ventricular lead stabilization to retain cardiac resynchronization therapy at long term: when is it advisable?","volume":"16","author":"Biffi","year":"2014","journal-title":"Europace"},{"key":"2019080504545289800_euz116-B5","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1007\/s12471-014-0556-6","article-title":"Incidence of lead dislodgement, malfunction and perforation during the first year following device implantation","volume":"22","author":"Ghani","year":"2014","journal-title":"Neth Heart J"},{"key":"2019080504545289800_euz116-B6","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1161\/01.CIR.0000085656.57918.B1","article-title":"Resynchronization therapy for the treatment of heart failure","volume":"108","author":"Saxon","year":"2003","journal-title":"Circulation"},{"key":"2019080504545289800_euz116-B7","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1111\/j.1540-8167.2007.00722.x","article-title":"Stabilization of the coronary sinus electrode position with coronary stent implantation to prevent and treat dislocation","volume":"18","author":"Szilagyi","year":"2007","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2019080504545289800_euz116-B8","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.hrthm.2011.01.016","article-title":"Long-term experience with coronary sinus side branch stenting to stabilize left ventricular electrode position","volume":"8","author":"Geller","year":"2011","journal-title":"Heart Rhythm"},{"key":"2019080504545289800_euz116-B9","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1161\/CIRCEP.113.001110","article-title":"Development of a technique for left ventricular endocardial pacing via puncture of the interventricular septum","volume":"7","author":"Betts","year":"2014","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2019080504545289800_euz116-B10","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/j.hrthm.2017.10.014","article-title":"Permanent His-bundle pacing as an alternative to biventricular pacing for cardiac resynchronization therapy: a multicenter experience","volume":"15","author":"Sharma","year":"2018","journal-title":"Heart Rhythm"},{"key":"2019080504545289800_euz116-B11","doi-asserted-by":"crossref","first-page":"530","DOI":"10.21037\/cdt.2018.03.08","article-title":"Leadless left ventricular endocardial pacing: a real alternative or a luxury for a few?","volume":"8","author":"De Maria","year":"2018","journal-title":"Cardiovasc Diagn Ther"},{"key":"2019080504545289800_euz116-B12","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1016\/S0002-9149(01)01892-6","article-title":"Comparison of chronic biventricular pacing between epicardial and endocardial left ventricular stimulation using Doppler tissue imaging in patients with heart failure","volume":"88","author":"Garrigue","year":"2001","journal-title":"Am J Cardiol"},{"key":"2019080504545289800_euz116-B13","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1093\/europace\/euq043","article-title":"Left ventricular endocardial pacing improves the clinical efficacy in a non-responder to cardiac resynchronization therapy: role of acute haemodynamic testing","volume":"12","author":"Bracke","year":"2010","journal-title":"Europace"},{"key":"2019080504545289800_euz116-B14","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1111\/pace.12678","article-title":"Comparison of the effects of epicardial and endocardial cardiac resynchronization therapy on transmural dispersion of repolarization","volume":"38","author":"Ozcan","year":"2015","journal-title":"Pacing Clin Electrophysiol"},{"key":"2019080504545289800_euz116-B15","doi-asserted-by":"crossref","first-page":"1258","DOI":"10.1111\/j.1540-8159.2011.03138.x","article-title":"Transseptal left ventricular endocardial pacing reduces dispersion of ventricular repolarization","volume":"34","author":"Scott","year":"2011","journal-title":"Pacing Clin Electrophysiol"},{"key":"2019080504545289800_euz116-B16","doi-asserted-by":"crossref","first-page":"1744","DOI":"10.1111\/j.1540-8159.2000.tb07010.x","article-title":"Mid-term follow-up of endocardial biventricular pacing","volume":"23","author":"Jais","year":"2000","journal-title":"Pacing Clin Electrophysiol"},{"key":"2019080504545289800_euz116-B17","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.ejcts.2004.09.029","article-title":"Surgical epicardial left ventricular lead versus coronary sinus lead placement in biventricular pacing","volume":"27","author":"Mair","year":"2005","journal-title":"Eur J Cardiothorac Surg"},{"key":"2019080504545289800_euz116-B18","doi-asserted-by":"crossref","first-page":"1653","DOI":"10.1093\/europace\/eur190","article-title":"Feasibility of percutaneous implantation of transapical endocardial left ventricular pacing electrode for cardiac resynchronization therapy","volume":"13","author":"Kassai","year":"2011","journal-title":"Europace"},{"key":"2019080504545289800_euz116-B19","doi-asserted-by":"crossref","first-page":"2118","DOI":"10.1093\/eurheartj\/ehv723","article-title":"ALternate Site Cardiac ResYNChronization (ALSYNC): a prospective and multicentre study of left ventricular endocardial pacing for cardiac resynchronization therapy","volume":"37","author":"Morgan","year":"2016","journal-title":"Eur Heart J"},{"key":"2019080504545289800_euz116-B20","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1093\/europace\/eur353","article-title":"Usefulness of electroanatomical mapping during transseptal endocardial left ventricular lead implantation","volume":"14","author":"Kutyifa","year":"2012","journal-title":"Europace"},{"key":"2019080504545289800_euz116-B21","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.ijcard.2018.01.030","article-title":"Benefits of left ventricular endocardial pacing comparing failed implants and prior non-responders to conventional cardiac resynchronization therapy: a subanalysis from the ALSYNC study","volume":"259","author":"Biffi","year":"2018","journal-title":"Int J Cardiol"},{"key":"2019080504545289800_euz116-B22","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1054\/jcaf.2002.31907","article-title":"Anticoagulation in patients with dilated cardiomyopathy and sinus rhythm: a critical literature review","volume":"8","author":"Sirajuddin","year":"2002","journal-title":"J Card Fail"},{"issue":"Suppl 1","key":"2019080504545289800_euz116-B23","first-page":"S31","article-title":"Long-term follow-up of biventricular pacing using a totally endocardial approach in patients with end-stage cardiac failure","volume":"30","author":"Pasquie","year":"2007","journal-title":"Pacing Clin Electrophysiol"},{"key":"2019080504545289800_euz116-B24","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.hrthm.2014.01.031","article-title":"Mid-term follow up of thromboembolic complications in left ventricular endocardial cardiac resynchronization therapy","volume":"11","author":"Rademakers","year":"2014","journal-title":"Heart Rhythm"},{"key":"2019080504545289800_euz116-B25","doi-asserted-by":"crossref","first-page":"13262.","DOI":"10.1038\/s41598-018-31692-z","article-title":"Cardiac resynchronization therapy: a comparison among left ventricular bipolar, quadripolar and active fixation leads","volume":"8","author":"Ziacchi","year":"2018","journal-title":"Sci Rep"},{"key":"2019080504545289800_euz116-B26","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.ipej.2016.10.008","article-title":"Lead related complications in quadripolar versus bipolar left ventricular leads","volume":"17","author":"Rijal","year":"2017","journal-title":"Indian Pacing Electrophysiol J"}],"container-title":["EP Europace"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/europace\/advance-article-pdf\/doi\/10.1093\/europace\/euz116\/28768745\/euz116.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/europace\/article-pdf\/21\/8\/1237\/29094345\/euz116.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,5]],"date-time":"2019-08-05T08:55:19Z","timestamp":1564995319000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/europace\/article\/21\/8\/1237\/5511591"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,5]]},"references-count":26,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2019,6,5]]},"published-print":{"date-parts":[[2019,8,1]]}},"URL":"https:\/\/doi.org\/10.1093\/europace\/euz116","relation":{},"ISSN":["1099-5129","1532-2092"],"issn-type":[{"value":"1099-5129","type":"print"},{"value":"1532-2092","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2019,8]]},"published":{"date-parts":[[2019,6,5]]}}}