{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,21]],"date-time":"2025-09-21T17:38:36Z","timestamp":1758476316649,"version":"3.37.3"},"reference-count":10,"publisher":"Oxford University Press (OUP)","issue":"5","license":[{"start":{"date-parts":[[2020,10,2]],"date-time":"2020-10-02T00:00:00Z","timestamp":1601596800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,11,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The Djumbodis system is a metallic stent designed to prevent false lumen dilatation after repair of acute aortic dissection. Although the exact number of Djumbodis stents inserted worldwide could not be ascertained from a review of the literature, available data indicate 9 specific device-related complications from 4 patient series and 3 case reports: stent deformity or fracture (4), progressive enlargement of the distal false lumen (3) and distal pseudoaneurysm (1); a further patient with pseudoaneurysm of the distal suture line is added from personal observation. The present review confirms the inability of the Djumbodis stent to provide reduction and\/or elimination of the false lumen after repair of type A dissection, highlighting peculiar device-related complications. Current survivors with a Djumbodis stent should undergo close follow-up to prevent possible catastrophic events due to device failure.<\/jats:p>","DOI":"10.1093\/icvts\/ivaa178","type":"journal-article","created":{"date-parts":[[2020,8,5]],"date-time":"2020-08-05T11:19:24Z","timestamp":1596626364000},"page":"704-707","source":"Crossref","is-referenced-by-count":9,"title":["Late complications of the Djumbodis system in patients with type A acute aortic dissection"],"prefix":"10.1093","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3473-1779","authenticated-orcid":false,"given":"Igor","family":"Vendramin","sequence":"first","affiliation":[{"name":"Cardiothoracic Department, University Hospital, Udine, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniela","family":"Piani","sequence":"additional","affiliation":[{"name":"Cardiothoracic Department, University Hospital, Udine, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"Lechiancole","sequence":"additional","affiliation":[{"name":"Cardiothoracic Department, University Hospital, Udine, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandro","family":"Sponga","sequence":"additional","affiliation":[{"name":"Cardiothoracic Department, University Hospital, Udine, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Massimo","family":"Sponza","sequence":"additional","affiliation":[{"name":"Department of Radiology, University Hospital, Udine, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michela","family":"Puppato","sequence":"additional","affiliation":[{"name":"Department of Radiology, University Hospital, Udine, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Uberto","family":"Bortolotti","sequence":"additional","affiliation":[{"name":"Cardiothoracic Department, University Hospital, Udine, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ugolino","family":"Livi","sequence":"additional","affiliation":[{"name":"Cardiothoracic Department, University Hospital, Udine, Italy"},{"name":"Department of Medical Area (DAME), University of Udine, Udine, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2020,10,2]]},"reference":[{"key":"2020110216312374700_ivaa178-B1","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.1093\/ejcts\/ezv351","article-title":"Proximal aortic repair versus extensive aortic repair in the treatment of acute type A aortic dissection: a meta-analysis","volume":"49","author":"Yan","year":"2016","journal-title":"Eur J Cardiothorac Surg"},{"key":"2020110216312374700_ivaa178-B2","doi-asserted-by":"crossref","first-page":"1450","DOI":"10.1016\/j.athoracsur.2010.06.087","article-title":"Transluminal stenting in type A acute aortic dissection: does the Djumbodis system have any impact on false lumen evolution?","volume":"90","author":"Ius","year":"2010","journal-title":"Ann Thorac Surg"},{"key":"2020110216312374700_ivaa178-B3","doi-asserted-by":"crossref","first-page":"e17","DOI":"10.1016\/j.athoracsur.2013.07.127","article-title":"Delayed stent deformity and fracture of Djumbodis dissection system","volume":"97","author":"Wong","year":"2014","journal-title":"Ann Thorac Surg"},{"key":"2020110216312374700_ivaa178-B4","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1093\/ejcts\/ezz367","article-title":"Open descending aortic replacement in a patient with a fractured DjumbodisTM dissection system","volume":"58","author":"Fujikawa","year":"2020","journal-title":"Eur J Cardiothorac Surg"},{"key":"2020110216312374700_ivaa178-B5","doi-asserted-by":"crossref","first-page":"336","DOI":"10.21037\/acs.2016.05.07","article-title":"Associated bare stenting of distal aorta with a Djumbodis\u00ae system versus conventional surgery in type A aortic dissection","volume":"5","author":"Caus","year":"2016","journal-title":"Ann Cardiothorac Surg"},{"key":"2020110216312374700_ivaa178-B6","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/j.ejcts.2011.05.063","article-title":"Effect on false-lumen status of a combined vascular an endovascular approach for the treatment of acute type A aortic dissection","volume":"41","author":"Czerny","year":"2012","journal-title":"Eur J Cardiothorac Surg"},{"key":"2020110216312374700_ivaa178-B7","doi-asserted-by":"crossref","first-page":"1616","DOI":"10.1016\/S0003-4975(01)03463-4","article-title":"Type A acute aortic dissection: combined operation plus stent management","volume":"73","author":"Roux","year":"2002","journal-title":"Ann Thorac Surg"},{"key":"2020110216312374700_ivaa178-B8","doi-asserted-by":"crossref","first-page":"1821","DOI":"10.1016\/j.jtcvs.2004.01.020","article-title":"New technologies for the treatment of type A aortic dissection: a case report","volume":"127","author":"Saccani","year":"2004","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2020110216312374700_ivaa178-B9","doi-asserted-by":"crossref","first-page":"1761","DOI":"10.1016\/j.athoracsur.2003.10.036","article-title":"Surgical repair and stent positioning for type A acute aortic dissection: a step forward?","volume":"79","author":"Saccani","year":"2005","journal-title":"An Thorac Surg"},{"key":"2020110216312374700_ivaa178-B10","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1016\/j.jtcvs.2005.10.013","article-title":"Type A aortic dissection: new surgical strategy using intra-operative stenting","volume":"131","author":"Leobon","year":"2006","journal-title":"J Thorac Cradiovasc Surg"}],"container-title":["Interactive CardioVascular and Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/icvts\/article-pdf\/31\/5\/704\/34105496\/ivaa178.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/icvts\/article-pdf\/31\/5\/704\/34105496\/ivaa178.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,2]],"date-time":"2020-11-02T21:31:47Z","timestamp":1604352707000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/icvts\/article\/31\/5\/704\/5917381"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,2]]},"references-count":10,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2020,10,2]]},"published-print":{"date-parts":[[2020,11,1]]}},"URL":"https:\/\/doi.org\/10.1093\/icvts\/ivaa178","relation":{},"ISSN":["1569-9285"],"issn-type":[{"type":"electronic","value":"1569-9285"}],"subject":[],"published-other":{"date-parts":[[2020,11]]},"published":{"date-parts":[[2020,10,2]]}}}