{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T11:31:59Z","timestamp":1784287919039,"version":"3.55.0"},"reference-count":5,"publisher":"Oxford University Press (OUP)","issue":"6","license":[{"start":{"date-parts":[[2020,11,1]],"date-time":"2020-11-01T00:00:00Z","timestamp":1604188800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,12,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>A patient with prior ascending aortic replacement for a type A acute dissection and a bovine arch presented with an asymptomatic chronic dissecting innominate artery aneurysm extending to both carotid arteries. As the patient refused redo open surgery, we performed a hybrid procedure with reverse extra-anatomic aortic arch debranching and a fenestrated endograft. The aneurysm was still partially perfused due to an endoleak and corrected 1 week later with vascular plugs.<\/jats:p>","DOI":"10.1093\/icvts\/ivaa197","type":"journal-article","created":{"date-parts":[[2020,8,19]],"date-time":"2020-08-19T11:20:55Z","timestamp":1597836055000},"page":"906-908","source":"Crossref","is-referenced-by-count":1,"title":["Vascular plug oversizing to treat an endoleak after hybrid surgery of the aortic arch"],"prefix":"10.1093","volume":"31","author":[{"given":"Alessandro C L","family":"Molinari","sequence":"first","affiliation":[{"name":"Vascular Surgery Unit, Manzoni Hospital, Lecco, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9963-1811","authenticated-orcid":false,"given":"Enrico","family":"Leo","sequence":"additional","affiliation":[{"name":"Vascular Surgery Unit, Manzoni Hospital, Lecco, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1840-9029","authenticated-orcid":false,"given":"Lorenzo","family":"Muzzarelli","sequence":"additional","affiliation":[{"name":"Vascular Surgery Unit, Manzoni Hospital, Lecco, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8991-6805","authenticated-orcid":false,"given":"Giovanni","family":"Rossi","sequence":"additional","affiliation":[{"name":"Vascular Surgery Unit, Manzoni Hospital, Lecco, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2020,11,1]]},"reference":[{"key":"2020120811434919200_ivaa197-B1","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1067\/mva.2001.115807","article-title":"Aneurysms of the innominate artery: surgical treatment of 27 patients","volume":"34","author":"Kieffer","year":"2001","journal-title":"J Vasc Surg"},{"key":"2020120811434919200_ivaa197-B2","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.jvscit.2018.02.004","article-title":"Reverse extra-anatomic aortic arch debranching procedure allowing thoracic endovascular aortic repair of a chronic ascending aortic aneurysm","volume":"4","author":"Canaud","year":"2018","journal-title":"J Vasc Surg Cases Innov Tech"},{"key":"2020120811434919200_ivaa197-B3","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1093\/icvts\/ivy345","article-title":"Accuracy of deployment of the Relay non-bare stent graft in the aortic arch","volume":"28","author":"Riesterer","year":"2019","journal-title":"Interact CardioVasc Thorac Surg"},{"key":"2020120811434919200_ivaa197-B4","doi-asserted-by":"crossref","first-page":"1659","DOI":"10.1016\/j.jvs.2017.04.063","article-title":"Impact of iliac artery anatomy on the outcome of fenestrated and branched endovascular aortic repair","volume":"66","author":"Gallitto","year":"2017","journal-title":"J Vasc Surg"},{"key":"2020120811434919200_ivaa197-B5","doi-asserted-by":"crossref","first-page":"1051","DOI":"10.1007\/s10439-019-02215-2","article-title":"Predictive numerical simulations of double branch stent-graft deployment in an aortic arch aneurysm","volume":"47","author":"Derycke","year":"2019","journal-title":"Ann Biomed Eng"}],"container-title":["Interactive CardioVascular and Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/icvts\/article-pdf\/31\/6\/906\/34804695\/ivaa197.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/icvts\/article-pdf\/31\/6\/906\/34804695\/ivaa197.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,9]],"date-time":"2020-12-09T23:04:20Z","timestamp":1607555060000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/icvts\/article\/31\/6\/906\/5948812"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11,1]]},"references-count":5,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2020,11,1]]},"published-print":{"date-parts":[[2020,12,7]]}},"URL":"https:\/\/doi.org\/10.1093\/icvts\/ivaa197","relation":{},"ISSN":["1569-9285"],"issn-type":[{"value":"1569-9285","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2020,12]]},"published":{"date-parts":[[2020,11,1]]}}}