{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T04:51:44Z","timestamp":1794286304062,"version":"4.9.0"},"reference-count":25,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2020,11,24]],"date-time":"2020-11-24T00:00:00Z","timestamp":1606176000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"funder":[{"DOI":"10.13039\/100006520","name":"Edwards Lifesciences","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006520","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,1,22]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p\/>\n               <jats:sec>\n                  <jats:title>OBJECTIVES<\/jats:title>\n                  <jats:p>This study aimed to compare the effect of surgical aortic valve replacement (SAVR) on coronary height in patients undergoing SAVR with rapid-deployment or SAVR with several standard sutured bioprostheses. This study may identify patients at higher risk of coronary obstruction during valve-in-valve procedures.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>METHODS<\/jats:title>\n                  <jats:p>We analysed 112 patients [mean age 71 (9 SD) years] who underwent SAVR with either a rapid-deployment aortic bioprosthesis (EDWARDS INTUITY Elite Valve) or other standard sutured biological valves. The coronary heights were assessed by computed tomography scan with the Philips 3D HeartNavigator system.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>RESULTS<\/jats:title>\n                  <jats:p>Two groups of patients were analysed: 51 (45.5%) patients implanted with an RD-AVR, which is a supra-annular valve that requires 3 anchoring sutures without the use of pledgets, and 61 (54.5%) patients implanted with a conventional supra-annular sutured bioprosthesis. The mean right and left coronary artery-to-annulus (RCAA and LCAA) heights at baseline were 16.9 (4.6 SD) and 14.2 (4.0 SD) mm in the standard sutured group and 16.3 (3.5 SD) and 12.8 (2.9 SD) mm in the RD-AVR group, respectively; a significantly shorter distance was observed for the left coronary artery in the rapid-deployment group (P\u2009=\u20090.420 for RCAA height and P\u2009=\u20090.044 for LCAA). Postoperatively, the mean RCAA and LCAA heights were significantly decreased in both groups compared to baseline. A mean of 11.5 (4.8 SD) mm for the RCAA and 7.9 (4.3 SD) mm for the LCAA in the standard sutured group as well as 14.4 (3.9 SD) mm for the RCAA and 9.0 (3.1 SD) mm for the LCAA in the RD-AVR group were observed (P\u2009&amp;lt;\u20090.001 for RCAA and LCAA in both the sutured and rapid-deployment groups). Despite the significant difference in the mean distance from the left coronary artery to annulus between the groups at baseline, the postoperative mean distance of the LCAA to the sewing ring was still higher in the RD-AVR group.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>CONCLUSIONS<\/jats:title>\n                  <jats:p>A significantly shorter coronary artery-to-aortic annulus distance for both the right and left main coronary arteries was observed after AVR with different conventional sutured supra-annular bioprostheses compared to AVR with rapid-deployment valves. These findings might be relevant for bioprosthesis selection, especially for young patients.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/icvts\/ivaa247","type":"journal-article","created":{"date-parts":[[2020,10,6]],"date-time":"2020-10-06T19:14:59Z","timestamp":1602011699000},"page":"196-203","source":"Crossref","is-referenced-by-count":8,"title":["Effect of conventional and rapid-deployment aortic valve replacement on the distance from the aortic annulus to coronary arteries"],"prefix":"10.1093","volume":"32","author":[{"given":"Iuliana","family":"Coti","sequence":"first","affiliation":[{"name":"Division of Surgery, Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Udo","family":"Maierhofer","sequence":"additional","affiliation":[{"name":"Division of Surgery, Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claus","family":"Rath","sequence":"additional","affiliation":[{"name":"Division of Anatomy, Center for Anatomy and Cell Biology, Medical University of Vienna, Vienna, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0925-6160","authenticated-orcid":false,"given":"Paul","family":"Werner","sequence":"additional","affiliation":[{"name":"Division of Surgery, Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Loewe","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular and Interventional Radiology, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2818-2227","authenticated-orcid":false,"given":"Alfred","family":"Kocher","sequence":"additional","affiliation":[{"name":"Division of Surgery, Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7257-110X","authenticated-orcid":false,"given":"Guenther","family":"Laufer","sequence":"additional","affiliation":[{"name":"Division of Surgery, Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4950-5432","authenticated-orcid":false,"given":"Martin","family":"Andreas","sequence":"additional","affiliation":[{"name":"Division of Surgery, Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2020,11,24]]},"reference":[{"key":"2022030919252036100_ivaa247-B1","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1016\/j.jtcvs.2011.04.048","article-title":"Aortic valve surgery: marked increases in volume and significant decreases in mechanical valve use\u2014an analysis of 41,227 patients over 5 years from the Society for Cardiothoracic Surgery in Great Britain and Ireland National database","volume":"142","author":"Dunning","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2022030919252036100_ivaa247-B2","doi-asserted-by":"crossref","first-page":"1262","DOI":"10.1016\/j.jtcvs.2015.01.052","article-title":"National trends in utilization and in-hospital outcomes of mechanical versus bioprosthetic aortic valve replacements","volume":"149","author":"Isaacs","year":"2015","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2022030919252036100_ivaa247-B3","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1001\/jama.2014.7246","article-title":"Transcatheter aortic valve implantation in failed bioprosthetic surgical valves","volume":"312","author":"Dvir","year":"2014","journal-title":"JAMA"},{"key":"2022030919252036100_ivaa247-B4","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1016\/j.jcin.2019.10.030","article-title":"Transcatheter ViV versus redo surgical AVR for the management of failed biological prosthesis: early and late outcomes in a propensity-matched cohort","volume":"13","author":"Tam","year":"2020","journal-title":"JACC Cardiovasc Interv"},{"key":"2022030919252036100_ivaa247-B5","doi-asserted-by":"crossref","first-page":"2335","DOI":"10.1161\/CIRCULATIONAHA.112.104505","article-title":"Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves","volume":"126","author":"Dvir","year":"2012","journal-title":"Circulation"},{"key":"2022030919252036100_ivaa247-B6","doi-asserted-by":"crossref","first-page":"2542","DOI":"10.1161\/CIRCULATIONAHA.113.000631","article-title":"Transcatheter aortic valve replacement for bioprosthetic aortic valve failure","volume":"127","author":"Webb","year":"2013","journal-title":"Circulation"},{"key":"2022030919252036100_ivaa247-B7","doi-asserted-by":"crossref","first-page":"2253","DOI":"10.1016\/j.jacc.2017.02.057","article-title":"Transcatheter aortic valve implantation within degenerated aortic surgical bioprostheses","volume":"69","author":"Webb","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"2022030919252036100_ivaa247-B8","doi-asserted-by":"crossref","first-page":"e002079","DOI":"10.1161\/CIRCINTERVENTIONS.114.002079","article-title":"Coronary obstruction in transcatheter aortic valve-in-valve implantation","volume":"8","author":"Dvir","year":"2015","journal-title":"Circ Cardiovasc Interv"},{"key":"2022030919252036100_ivaa247-B9","first-page":"311","article-title":"Coronary obstruction following transcatheter aortic valve implantation for degenerative bioprosthetic surgical valves: a systematic literature review","volume":"21","author":"Ribeiro","year":"2013","journal-title":"Rev Bras Cardiol Invasiva"},{"key":"2022030919252036100_ivaa247-B10","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.jtcvs.2012.07.108","article-title":"One-year outcomes of the surgical treatment of aortic stenosis with a next generation surgical aortic valve (TRITON) trial: a prospective multicenter study of rapid-deployment aortic valve replacement with the EDWARDS INTUITY Valve System","volume":"145","author":"Kocher","year":"2013","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2022030919252036100_ivaa247-B11","doi-asserted-by":"crossref","first-page":"1294","DOI":"10.1016\/j.athoracsur.2014.05.033","article-title":"Aortic valve replacement and concomitant procedures with the Perceval valve: results of European trials","volume":"98","author":"Shrestha","year":"2014","journal-title":"Ann Thorac Surg"},{"key":"2022030919252036100_ivaa247-B12","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1093\/ejcts\/ezy273","article-title":"Intermediate-term outcome of 500 consecutive rapid-deployment surgical aortic valve procedures","volume":"55","author":"Andreas","year":"2019","journal-title":"Eur J Cardiothorac Surg"},{"key":"2022030919252036100_ivaa247-B13","doi-asserted-by":"crossref","DOI":"10.1016\/j.athoracsur.2020.02.030","article-title":"Rapid-deployment aortic valves for patients with a small aortic root: a single-center experience","author":"Coti","year":"2020","journal-title":"Ann Thorac Surg"},{"key":"2022030919252036100_ivaa247-B14","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.ejcts.2007.12.055","article-title":"Guidelines for reporting mortality and morbidity after cardiac valve interventions","volume":"33","author":"Akins","year":"2008","journal-title":"Eur J Cardiothorac Surg"},{"key":"2022030919252036100_ivaa247-B15","doi-asserted-by":"crossref","first-page":"2739","DOI":"10.1093\/eurheartj\/ehx391","article-title":"2017 ESC\/EACTS guidelines for the management of valvular heart disease","volume":"38","author":"Baumgartner","year":"2017","journal-title":"Eur Heart J"},{"key":"2022030919252036100_ivaa247-B16","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1111\/joic.12520","article-title":"Valve in valve transcatheter aortic valve implantation (ViV-TAVI) versus redo\u2014surgical aortic valve replacement (redo-SAVR): a systematic review and meta-analysis","volume":"31","author":"Nalluri","year":"2018","journal-title":"J Interv Cardiol"},{"key":"2022030919252036100_ivaa247-B17","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1093\/eurheartj\/ehx455","article-title":"Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: insights from the VIVID registry","volume":"39","author":"Ribeiro","year":"2018","journal-title":"Eur Heart J"},{"key":"2022030919252036100_ivaa247-B18","doi-asserted-by":"crossref","first-page":"572","DOI":"10.4244\/EIJV11I5A112","article-title":"Clinical impact of coronary protection during transcatheter aortic valve implantation: first reported series of patients","volume":"11","author":"Yigal","year":"2015","journal-title":"EuroIntervention"},{"key":"2022030919252036100_ivaa247-B19","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1002\/ccd.22861","article-title":"Coronary obstruction following transcatheter aortic valve-in-valve implantation for failed surgical bioprostheses","volume":"77","author":"Gurvitch","year":"2011","journal-title":"Cathet Cardiovasc Intervent"},{"key":"2022030919252036100_ivaa247-B20","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.jtcvs.2012.07.108","article-title":"One-year outcomes of the surgical treatment of aortic stenosis with a next generation surgical aortic valve (TRITON) trial: a prospective multicenter study of rapid-deployment aortic valve replacement with the EDWARDS INTUITY Valve System","volume":"145","author":"Kocher","year":"2013","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2022030919252036100_ivaa247-B21","doi-asserted-by":"crossref","first-page":"2854","DOI":"10.1016\/j.jtcvs.2014.07.049","article-title":"Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patients","volume":"148","author":"Haverich","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2022030919252036100_ivaa247-B22","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1093\/ejcts\/ezx103","article-title":"Long-term outcomes of a rapid deployment aortic valve: data up to 5 years","volume":"52","author":"Laufer","year":"2017","journal-title":"Eur J Cardiothorac Surg"},{"key":"2022030919252036100_ivaa247-B23","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s13239-016-0284-8","article-title":"Pledget-armed sutures affect the haemodynamic performance of biologic aortic valve substitutes: a preliminary experimental and computational study","volume":"8","author":"Capelli","year":"2017","journal-title":"Cardiovasc Eng Technol"},{"key":"2022030919252036100_ivaa247-B24","doi-asserted-by":"crossref","first-page":"1902","DOI":"10.4244\/EIJ-D-17-00578","article-title":"Valve-in-valve transcatheter aortic valve implantation into a novel, sutureless bioprosthesis: technical considerations","volume":"13","author":"Andreas","year":"2018","journal-title":"EuroIntervention"},{"key":"2022030919252036100_ivaa247-B25","doi-asserted-by":"crossref","first-page":"37","DOI":"10.4244\/EIJ-D-18-00752","article-title":"Transcatheter aortic valve-in-valve implantation in degenerative rapid deployment bioprostheses","volume":"15","author":"Landes","year":"2019","journal-title":"EuroIntervention"}],"container-title":["Interactive CardioVascular and Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/32\/2\/196\/42780957\/ivaa247.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/32\/2\/196\/42780957\/ivaa247.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,9]],"date-time":"2022-03-09T19:25:51Z","timestamp":1646853951000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/icvts\/article\/32\/2\/196\/6000414"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11,24]]},"references-count":25,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2020,11,24]]},"published-print":{"date-parts":[[2021,1,22]]}},"URL":"https:\/\/doi.org\/10.1093\/icvts\/ivaa247","relation":{},"ISSN":["1569-9285"],"issn-type":[{"value":"1569-9285","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2021,2,1]]},"published":{"date-parts":[[2020,11,24]]}}}