{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T11:14:37Z","timestamp":1740136477198,"version":"3.37.3"},"reference-count":22,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2021,3,30]],"date-time":"2021-03-30T00:00:00Z","timestamp":1617062400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,7,26]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p\/>\n               <jats:sec>\n                  <jats:title>OBJECTIVES<\/jats:title>\n                  <jats:p>This study aims to analyse the risks associated with valve-in-valve procedures for treating structural valve deterioration in Mitroflow bioprostheses, as well as to determine the impact of the original Mitroflow size on the patients\u2019 long-term outcomes.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>METHODS<\/jats:title>\n                  <jats:p>Between January 2012 and September 2019, 21 patients (61.9% males; mean age 82.4\u2009\u00b1\u20095.4\u2009years) were treated for Mitroflow deterioration with valve-in-valve procedures (12 transapical and 9 transfemoral).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>RESULTS<\/jats:title>\n                  <jats:p>Mean EuroSCORE I and EuroSCORE II were 28.2% \u00b1 13.6% and 10.5% \u00b1 6.1%, respectively. Six patients presented an indexed aortic root diameter &amp;lt;14\u2009mm\/m2 and 7 patients a diameter of sinus of Valsalva &amp;lt;30\u2009mm. Implanted transcatheter valve sizes were 20\u2009mm in 6 cases, 23\u2009mm in 14 cases and 26\u2009mm in 1 patient. A Valve Academic Research Consortium-2 complication occurred in 23.8% of cases, including 3 coronary occlusions. In-hospital mortality was 9.5%. The 20\u2009mm transcatheter valves presented significantly higher postoperative peak and mean aortic gradients than other sizes (54.1\u2009\u00b1\u200911.3\u2009mmHg vs 29.9\u2009\u00b1\u20099.6\u2009mmHg, P\u2009=\u20090.003; and 29.3\u2009\u00b1\u20097.7\u2009mmHg vs 17.4\u2009\u00b1\u20095.9\u2009mmHg, P\u2009=\u20090.015, respectively). There were 12 cases of patient\u2013prosthesis mismatch (57.1%) and 3 cases (14.3%) of severe patient\u2013prosthesis mismatch. Cumulative survival was 85.7% \u00b1 7.6% at 1\u2009year, 74.3% \u00b1 10% at 2\u2009years and 37.1% \u00b1 14.1% at 5\u2009years.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>CONCLUSIONS<\/jats:title>\n                  <jats:p>Valve-in-valve procedures with balloon-expandable transcatheter valves associate a high risk of coronary occlusion in patients with indexed aortic root diameter &amp;lt;14\u2009mm\/m2 and low coronary ostia &amp;lt;12\u2009mm. Valve-in valve procedures with 20\u2009mm balloon-expandable transcatheter valves in \u226421\u2009mm Mitroflow bioprosthesis leave significant residual transvalvular gradients that might obscure patients\u2019 long-term outcomes.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/icvts\/ivab065","type":"journal-article","created":{"date-parts":[[2021,2,12]],"date-time":"2021-02-12T20:20:17Z","timestamp":1613161217000},"page":"173-180","source":"Crossref","is-referenced-by-count":0,"title":["Balloon-expanding transcatheter aortic valve implantation for degenerated Mitroflow bioprostheses: clinical and echocardiographic long-term outcomes"],"prefix":"10.1093","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1483-9037","authenticated-orcid":false,"given":"Victor X","family":"Mosquera","sequence":"first","affiliation":[{"name":"Department of Cardiac Surgery, Complejo Hospitalario Universitario de A Coru\u00f1a, A Coru\u00f1a, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2741-732X","authenticated-orcid":false,"given":"Alberto","family":"Bouzas-Mosquera","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Complejo Hospitalario Universitario de A Coru\u00f1a, A Coru\u00f1a, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yago","family":"Vilela-Gonz\u00e1lez","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Complejo Hospitalario Universitario de A Coru\u00f1a, A Coru\u00f1a, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos","family":"Velasco","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Complejo Hospitalario Universitario de A Coru\u00f1a, A Coru\u00f1a, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jorge","family":"Salgado-Fern\u00e1ndez","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Complejo Hospitalario Universitario de A Coru\u00f1a, A Coru\u00f1a, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ram\u00f3n","family":"Calvi\u00f1o-Santos","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Complejo Hospitalario Universitario de A Coru\u00f1a, A Coru\u00f1a, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicol\u00e1s","family":"V\u00e1zquez-Gonz\u00e1lez","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Complejo Hospitalario Universitario de A Coru\u00f1a, A Coru\u00f1a, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos\u00e9 M","family":"V\u00e1zquez-Rodr\u00edguez","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Complejo Hospitalario Universitario de A Coru\u00f1a, A Coru\u00f1a, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos\u00e9 M","family":"Herrera-Nore\u00f1a","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Complejo Hospitalario Universitario de A Coru\u00f1a, A Coru\u00f1a, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2021,3,30]]},"reference":[{"key":"2022030915261953600_ivab065-B1","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1016\/j.jcin.2017.03.018","article-title":"1-Year results in patients undergoing transcatheter aortic valve replacement with failed surgical bioprostheses","volume":"10","author":"Deeb","year":"2017","journal-title":"JACC Cardiovasc Interv"},{"key":"2022030915261953600_ivab065-B2","doi-asserted-by":"crossref","first-page":"e007038","DOI":"10.1161\/CIRCINTERVENTIONS.118.007038","article-title":"Long-term outcomes after transcatheter aortic valve-in-valve replacement","volume":"11","author":"de Freitas Campos Guimar\u00e3es","year":"2018","journal-title":"Circ Cardiovasc Interv"},{"key":"2022030915261953600_ivab065-B3","doi-asserted-by":"crossref","first-page":"2731","DOI":"10.1093\/eurheartj\/ehaa544","article-title":"Long-term outcomes after transcatheter aortic valve implantation in failed bioprosthetic valves","volume":"41","author":"Bleiziffer","year":"2020","journal-title":"Eur Heart J"},{"key":"2022030915261953600_ivab065-B4","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1002\/ccd.22967","article-title":"Coronary obstruction following transcatheter aortic valve-in-valve implantation for failed surgical bioprostheses","volume":"77","author":"Mack","year":"2011","journal-title":"Catheter Cardiovasc Interv"},{"key":"2022030915261953600_ivab065-B5","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1002\/ccd.22861","article-title":"Coronary obstruction following transcatheter aortic valve-in-valve implantation for failed surgical bioprostheses","volume":"77","author":"Gurvitch","year":"2011","journal-title":"Catheter Cardiovasc Interv"},{"key":"2022030915261953600_ivab065-B6","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1002\/ccd.24540","article-title":"Balloon valuloplasty prior to transcatheter valve-in-valve implantation in a degenerated Mitroflow aortic bioprosthesis","volume":"81","author":"Cerillo","year":"2013","journal-title":"Catheter Cardiovasc Interv"},{"key":"2022030915261953600_ivab065-B7","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1016\/j.athoracsur.2014.07.059","article-title":"Image-based decision-making treatment of degenerated mitroflow and trifecta prostheses","volume":"98","author":"Van Linden","year":"2014","journal-title":"Ann Thorac Surg"},{"key":"2022030915261953600_ivab065-B8","doi-asserted-by":"crossref","first-page":"1532","DOI":"10.1016\/j.athoracsur.2014.11.047","article-title":"Single institution experience with transcatheter valve-in-valve implantation emphasizing strategies for coronary protection","volume":"99","author":"Camboni","year":"2015","journal-title":"Ann Thorac Surg"},{"key":"2022030915261953600_ivab065-B9","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.ejcts.2010.03.069","article-title":"The Italian study on the Mitroflow postoperative results (ISTHMUS): a 20-year, multicentre evaluation of Mitroflow pericardial bioprosthesis","volume":"39","author":"Investigators","year":"2011","journal-title":"Eur J Cardiothorac Surg"},{"key":"2022030915261953600_ivab065-B10","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1093\/ejcts\/ezx161","article-title":"Long-term results of the Mitroflow aortic pericardial bioprosthesis in over 800 patients: limited durability and mechanisms of dysfunction","volume":"52","author":"Ius","year":"2017","journal-title":"Eur J Cardiothorac Surg"},{"key":"2022030915261953600_ivab065-B11","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1111\/jocs.12726","article-title":"Long-term outcomes and durability of the mitroflow aortic bioprosthesis","volume":"31","author":"Mosquera","year":"2016","journal-title":"J Card Surg"},{"key":"2022030915261953600_ivab065-B12","doi-asserted-by":"crossref","first-page":"1372","DOI":"10.1016\/j.jtcvs.2012.07.104","article-title":"Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: technical considerations and results","volume":"144","author":"Bapat","year":"2012","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2022030915261953600_ivab065-B13","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1111\/jocs.13720","article-title":"Efficacy and safety of transcatheter valve-in-valve replacement for Mitroflow bioprosthetic valve dysfunction","volume":"33","author":"Mosquera","year":"2018","journal-title":"J Card Surg"},{"key":"2022030915261953600_ivab065-B14","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.jtcvs.2012.09.002","article-title":"Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document","volume":"145","author":"Kappetein","year":"2013","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2022030915261953600_ivab065-B15","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.jcmg.2018.04.010","article-title":"Comprehensive echocardiographic assessment of normal transcatheter valve function","volume":"12","author":"Hahn","year":"2019","journal-title":"JACC Cardiovasc Imaging"},{"key":"2022030915261953600_ivab065-B16","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1136\/hrt.2005.067363","article-title":"Prosthesis-patient mismatch: definition, clinical impact, and prevention","volume":"92","author":"Pibarot","year":"2006","journal-title":"Heart"},{"key":"2022030915261953600_ivab065-B17","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1093\/eurheartj\/ehx455","article-title":"Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: insights from the VIVID registry","volume":"39","author":"Ribeiro","year":"2018","journal-title":"Eur Heart J"},{"key":"2022030915261953600_ivab065-B18","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jcmg.2018.12.003","article-title":"Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR): an expert consensus document of the Society of Cardiovascular Computed Tomography","volume":"12","author":"Blanke","year":"2019","journal-title":"JACC Cardiovasc Imaging"},{"key":"2022030915261953600_ivab065-B19","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1001\/jama.2014.7246","article-title":"Transcatheter aortic valve implantation in failed bioprosthetic surgical valves","volume":"312","author":"Dvir","year":"2014","journal-title":"Jama"},{"key":"2022030915261953600_ivab065-B20","doi-asserted-by":"crossref","first-page":"1603","DOI":"10.1016\/j.jcin.2016.05.025","article-title":"Mitral regurgitation after transcatheter aortic valve replacement: prognosis, imaging predictors, and potential management","volume":"9","author":"Cortes","year":"2016","journal-title":"JACC Cardiovasc Interv"},{"key":"2022030915261953600_ivab065-B21","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.ijcard.2019.01.094","article-title":"Self-expanding transcatheter aortic valve implantation for degenerated Mitroflow bioprosthesis: early outcomes","volume":"287","author":"Pascual","year":"2019","journal-title":"Int J Cardiol"},{"key":"2022030915261953600_ivab065-B22","doi-asserted-by":"crossref","first-page":"1240","DOI":"10.1016\/j.jcin.2019.03.035","article-title":"The BASILICA trial: prospective multicenter investigation of intentional leaflet laceration to prevent TAVR coronary obstruction","volume":"12","author":"Khan","year":"2019","journal-title":"JACC Cardiovasc Interv"}],"container-title":["Interactive CardioVascular and Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/33\/2\/173\/42781172\/ivab065.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/33\/2\/173\/42781172\/ivab065.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,9]],"date-time":"2022-03-09T15:53:04Z","timestamp":1646841184000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/icvts\/article\/33\/2\/173\/6200564"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,30]]},"references-count":22,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2021,3,30]]},"published-print":{"date-parts":[[2021,7,26]]}},"URL":"https:\/\/doi.org\/10.1093\/icvts\/ivab065","relation":{},"ISSN":["1569-9285"],"issn-type":[{"type":"electronic","value":"1569-9285"}],"subject":[],"published-other":{"date-parts":[[2021,8,1]]},"published":{"date-parts":[[2021,3,30]]}}}