{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T16:51:07Z","timestamp":1774975867301,"version":"3.50.1"},"reference-count":26,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[2021,8,7]],"date-time":"2021-08-07T00:00:00Z","timestamp":1628294400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,1,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>\u2002<\/jats:title><\/jats:sec><jats:sec><jats:title>OBJECTIVES<\/jats:title><jats:p>The aim of this study was to report the outcomes of open or hybrid repair of failed thoraco-abdominal aortic aneurysm endovascular treatment with Multilayer Flow Modulator (MFM) stents.<\/jats:p><\/jats:sec><jats:sec><jats:title>METHODS<\/jats:title><jats:p>All patients who underwent open or hybrid repair of a failed MFM aortic treatment were retrospectively analysed. Perioperative and postoperative data, as well as midterm survival, were assessed.<\/jats:p><\/jats:sec><jats:sec><jats:title>RESULTS<\/jats:title><jats:p>Between 2013 and 2020, 39 patients received an open or hybrid conversion after endovascular treatment. Five of them [13%; 4 males; median age 68\u2009years (interquartile range 66\u201376)] were previously treated with aortic MFM stents (Cardiatis, Isnes, Belgium). Among these, the median interval between index repair and conversion was 84\u2009months (interquartile range 75\u201384). The median aneurysm diameter was 9.6\u2009cm (interquartile range 8\u201310). Renovisceral vessels steno-occlusion was highly prevalent: 2 renal arteries were occluded; 3 coeliac trunks, 2 renal arteries and 1 superior mesenteric artery had a &amp;gt;70% ostial stenosis. Open standard thoraco-abdominal aneurysm conversion was performed in 3 fit patients, while a hybrid approach with visceral debranching and tube endografting was performed in 2 high-risk patients. Two patients (2 open repairs) died intraoperatively, and 1 (hybrid repair) postoperatively. The 2 successfully treated patients are alive at 4- and 34-month follow-up, respectively, with patent visceral branches.<\/jats:p><\/jats:sec><jats:sec><jats:title>CONCLUSIONS<\/jats:title><jats:p>Open or hybrid thoraco-abdominal aortic aneurysm treatment after failed endovascular aortic repair with MFM stents might be the only surgical option to address sac enlargements and ruptures or branch-related failures. However, both procedures had a poor prognosis due to both the impaired preoperative patient\u2019s status and the surgical complexity in the presented series.<\/jats:p><\/jats:sec>","DOI":"10.1093\/icvts\/ivab224","type":"journal-article","created":{"date-parts":[[2021,7,20]],"date-time":"2021-07-20T19:31:53Z","timestamp":1626809513000},"page":"111-119","source":"Crossref","is-referenced-by-count":1,"title":["Late surgical conversion of failed Multilayer Flow Modulator stenting in thoraco-abdominal aneurysms"],"prefix":"10.1093","volume":"34","author":[{"given":"Simone","family":"Salvati","sequence":"first","affiliation":[{"name":"Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, \u201cVita-Salute\u201d University , Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6643-394X","authenticated-orcid":false,"given":"Victor","family":"Bilman","sequence":"additional","affiliation":[{"name":"Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, \u201cVita-Salute\u201d University , Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5462-1705","authenticated-orcid":false,"given":"Andrea","family":"Melloni","sequence":"additional","affiliation":[{"name":"Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, \u201cVita-Salute\u201d University , Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1201-0508","authenticated-orcid":false,"given":"Domenico","family":"Baccellieri","sequence":"additional","affiliation":[{"name":"Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, \u201cVita-Salute\u201d University , Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1546-7159","authenticated-orcid":false,"given":"Andrea","family":"Kahlberg","sequence":"additional","affiliation":[{"name":"Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, \u201cVita-Salute\u201d University , Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4168-1792","authenticated-orcid":false,"given":"Germano","family":"Melissano","sequence":"additional","affiliation":[{"name":"Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, \u201cVita-Salute\u201d University , Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roberto","family":"Chiesa","sequence":"additional","affiliation":[{"name":"Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, \u201cVita-Salute\u201d University , Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6871-2176","authenticated-orcid":false,"given":"Luca","family":"Bertoglio","sequence":"additional","affiliation":[{"name":"Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, \u201cVita-Salute\u201d University , Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2021,8,7]]},"reference":[{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1583\/12-4077MR-R.1","article-title":"One-year results of the Multilayer Flow Modulator stent in the management of thoracoabdominal aortic aneurysms and type B dissections","volume":"20","author":"Sultan","year":"2013","journal-title":"J Endovasc Ther"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1016\/j.jvs.2016.12.092","article-title":"Evidence of use of Multilayer Flow Modulator stents in treatment of thoracoabdominal aortic aneurysms and dissections","volume":"65","author":"Oderich","year":"2017","journal-title":"J Vasc Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"762","DOI":"10.1177\/1526602816653095","article-title":"Three-year outcomes with the Multilayer Flow Modulator for repair of thoracoabdominal aneurysms: a follow-up report from the STRATO trial","volume":"23","author":"Vaislic","year":"2016","journal-title":"J Endovasc Ther"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1016\/j.jvs.2010.07.008","article-title":"Reporting standards for thoracic endovascular aortic repair (TEVAR)","volume":"52","author":"Fillinger","year":"2010","journal-title":"J Vasc Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1067\/mva.2002.123763","article-title":"Reporting standards for endovascular aortic aneurysm repair","volume":"35","author":"Chaikof","year":"2002","journal-title":"J Vasc Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"S152","DOI":"10.1097\/CCM.0b013e318168c613","article-title":"Conventional markers of kidney function","volume":"36","author":"Bagshaw","year":"2008","journal-title":"Crit Care Med"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.ejvs.2016.06.005","article-title":"Editor\u2019s Choice\u2014Management of descending thoracic aorta diseases: clinical practice guidelines of the European Society for Vascular Surgery (ESVS)","volume":"53","author":"Committee","year":"2017","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.ejvs.2016.12.016","article-title":"Predicting the need for intra-operative large volume blood transfusions during thoraco-abdominal aortic aneurysm repair","volume":"53","author":"Pieri","year":"2017","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/j.ejvs.2018.09.027","article-title":"Epidural analgesia in open thoraco-abdominal aortic aneurysm repair","volume":"57","author":"Monaco","year":"2019","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1016\/j.jvs.2006.10.057","article-title":"Hybrid approach to thoracoabdominal aortic aneurysms in patients with prior aortic surgery","volume":"45","author":"Chiesa","year":"2007","journal-title":"J Vasc Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1583\/1545-1550-16.4.451","article-title":"Hybrid procedures for thoracoabdominal aneurysms","volume":"16","author":"Melissano","year":"2009","journal-title":"J Endovasc Ther"},{"key":"2023032020064386400_","first-page":"404","article-title":"Video-atlas of hybrid thoracoabdominal aortic aneurysm repair","volume":"1","author":"Chiesa","year":"2012","journal-title":"Ann Cardiothorac Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1016\/j.jvs.2013.09.055","article-title":"Comparison of renal perfusion solutions during thoracoabdominal aortic aneurysm repair","volume":"59","author":"Tshomba","year":"2014","journal-title":"J Vasc Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"1855","DOI":"10.1007\/s00270-020-02636-w","article-title":"Late open conversion following failure of EVAR and TEVAR: \u201cstate of the art\u201d","volume":"43","author":"Rinaldi","year":"2020","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2023032020064386400_","first-page":"381","article-title":"Thoracoabdominal aortic aneurysm repair with a branched graft","volume":"1","author":"la Cruz","year":"2012","journal-title":"Ann Cardiothorac Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1093\/ejcts\/ezv168","article-title":"Statistical and data reporting guidelines for the European Journal of Cardio-Thoracic Surgery and the Interactive CardioVascular and Thoracic Surgery","volume":"48","author":"Hickey","year":"2015","journal-title":"Eur J Cardiothorac Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1016\/j.jvs.2018.01.037","article-title":"Early and midterm outcome of Multilayer Flow Modulator stent for complex aortic aneurysm treatment in Germany","volume":"68","author":"Ibrahim","year":"2018","journal-title":"J Vasc Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1583\/13-4514MR.1","article-title":"When not to implant the Multilayer Flow Modulator: lessons learned from application outside the indications for use in patients with thoracoabdominal pathologies","volume":"21","author":"Sultan","year":"2014","journal-title":"J Endovasc Ther"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"629","DOI":"10.2147\/IJGM.S33008","article-title":"Multiple multilayer stents for thoracoabdominal aortic aneurysm: a possible new tool for aortic endovascular surgery","volume":"5","author":"Tolva","year":"2012","journal-title":"Int J Gen Med"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1177\/1526602816636891","article-title":"Systematic review and patient-level meta-analysis of the Streamliner Multilayer Flow Modulator in the management of complex thoracoabdominal aortic pathology","volume":"23","author":"Hynes","year":"2016","journal-title":"J Endovasc Ther"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1583\/11-3398C.1","article-title":"Treatment of complex thoracoabdominal or juxtarenal aortic aneurysms with a multilayer stent","volume":"19","author":"De Vries","year":"2012","journal-title":"J Endovasc Ther"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1583\/13-4553R.1","article-title":"One-year outcomes following repair of thoracoabdominal aneurysms with the Multilayer Flow Modulator: report from the STRATO trial","volume":"21","author":"Vaislic","year":"2014","journal-title":"J Endovasc Ther"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"1360","DOI":"10.1016\/j.jvs.2017.09.024","article-title":"Management of visceral aortic patch aneurysms after thoracoabdominal repair with open, hybrid, or endovascular approach","volume":"67","author":"Bertoglio","year":"2018","journal-title":"J Vasc Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.avsg.2015.07.042","article-title":"A single-center experience of aortic and iliac artery aneurysm treated with Multilayer Flow Modulator","volume":"30","author":"Pane","year":"2016","journal-title":"Ann Vasc Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"1632","DOI":"10.1016\/j.jvs.2014.04.032","article-title":"Severe visceral ischemia and death after multilayer stent deployment for the treatment of a thoracoabdominal aortic aneurysm","volume":"62","author":"Cavalcante","year":"2015","journal-title":"J Vasc Surg"},{"key":"2023032020064386400_","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1590\/1677-5449.011417","article-title":"Contemporary strategies for repair of complex thoracoabdominal aortic aneurysms: real-world experiences and multilayer stents as an alternative","volume":"16","author":"Kolvenbach","year":"2017","journal-title":"J Vasc Bras"}],"container-title":["Interactive CardioVascular and Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/34\/1\/111\/49571677\/ivab224.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/34\/1\/111\/49571677\/ivab224.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,6]],"date-time":"2023-11-06T08:13:58Z","timestamp":1699258438000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/icvts\/article\/34\/1\/111\/6345422"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,7]]},"references-count":26,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,1,6]]}},"URL":"https:\/\/doi.org\/10.1093\/icvts\/ivab224","relation":{},"ISSN":["1569-9285"],"issn-type":[{"value":"1569-9285","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2022,1,1]]},"published":{"date-parts":[[2021,8,7]]}}}