{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,3,19]],"date-time":"2024-03-19T05:59:42Z","timestamp":1710827982071},"reference-count":5,"publisher":"Oxford University Press (OUP)","issue":"6","license":[{"start":{"date-parts":[[2021,10,19]],"date-time":"2021-10-19T00:00:00Z","timestamp":1634601600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Mitral valve replacement in infants is challenging and there are limited alternative valves available. Since the Boston group published their first report on alternative valves for mitral valve replacement in infants, there has been a growth in the literature on the topic, mostly based on the use of a stented bovine jugular vein graft (Melody\u00ae valve). The challenges of the Melody valve are firstly in its length of 28\u2009mm unexpanded, which has the potential to cause left ventricular outflow tract obstruction, and secondly, the valve needs mechanical dilatation, which is laborious. A modified No-React\u00ae Injectable Biopulmonic\u2122 Prosthesis (Bio Integral Surgical, Inc., Mississauga, ON, Canada) which is shorter (19\u2009mm) and simpler in that it is self-expanding was implanted in a 14-month-old child to replace her mitral valve. The operation was successful and the short-term function of the prosthesis is good.<\/jats:p>","DOI":"10.1093\/icvts\/ivab274","type":"journal-article","created":{"date-parts":[[2021,10,12]],"date-time":"2021-10-12T03:18:31Z","timestamp":1634008711000},"page":"1168-1170","source":"Crossref","is-referenced-by-count":1,"title":["An alternative valve for mitral valve replacement in young children: using an NO-REACT\u00ae INJECTABLE BIOPULMONIC\u2122 prosthesis as a mitral valve replacement in a 14-month-old child"],"prefix":"10.1093","volume":"34","author":[{"given":"Cristina","family":"Carro","sequence":"first","affiliation":[{"name":"Pediatric Cardiac Surgery, ASST Grande Ospedale Metropolitano Niguarda , Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefano","family":"Marianeschi","sequence":"additional","affiliation":[{"name":"Pediatric Cardiac Surgery, ASST Grande Ospedale Metropolitano Niguarda , Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simone","family":"Ghiselli","sequence":"additional","affiliation":[{"name":"Pediatric Cardiac Surgery, ASST Grande Ospedale Metropolitano Niguarda , Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicola","family":"Uricchio","sequence":"additional","affiliation":[{"name":"Pediatric Cardiac Surgery Unit, ASST Papa Giovanni XXIII , Bergamo, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2021,10,19]]},"reference":[{"key":"2022060115245218000_ivab274-B1","doi-asserted-by":"crossref","first-page":"e97","DOI":"10.1016\/j.athoracsur.2012.02.101","article-title":"Modification of a stented bovine jugular vein conduit (melody valve) for surgical mitral valve replacement","volume":"94","author":"Abdullah","year":"2012","journal-title":"Ann Thorac Surg"},{"key":"2022060115245218000_ivab274-B2","doi-asserted-by":"crossref","first-page":"e007145","DOI":"10.1161\/CIRCINTERVENTIONS.118.007145","article-title":"Surgical atrioventricular valve replacement with melody valve in infants and children a multicenter study","volume":"11","author":"Pluchinotta","year":"2018","journal-title":"Circ Cardiovasc Interv"},{"key":"2022060115245218000_ivab274-B3","doi-asserted-by":"crossref","first-page":"e429","DOI":"10.1016\/j.athoracsur.2017.08.005","article-title":"Edwards Sapien 3: valve for mitral replacement in a child after melody valve endocarditis","volume":"104","author":"Trezzi","year":"2017","journal-title":"Ann Thorac Surg"},{"key":"2022060115245218000_ivab274-B4","doi-asserted-by":"crossref","first-page":"1403","DOI":"10.1016\/S0140-6736(00)02844-0","article-title":"Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction","volume":"356","author":"Bonhoeffer","year":"2000","journal-title":"Lancet"},{"key":"2022060115245218000_ivab274-B5","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1016\/S0003-4975(00)02456-5","article-title":"Shelhigh No-React porcine pulmonic valve conduit: a new alternative to the homograft","volume":"71","author":"Marianeschi","year":"2001","journal-title":"Ann Thorac Surg"}],"container-title":["Interactive CardioVascular and Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/34\/6\/1168\/43918488\/ivab274.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/34\/6\/1168\/43918488\/ivab274.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T15:25:26Z","timestamp":1654097126000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/icvts\/article\/34\/6\/1168\/6400642"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,19]]},"references-count":5,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2021,10,19]]},"published-print":{"date-parts":[[2022,6,1]]}},"URL":"https:\/\/doi.org\/10.1093\/icvts\/ivab274","relation":{},"ISSN":["1569-9285"],"issn-type":[{"value":"1569-9285","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2022,6,1]]},"published":{"date-parts":[[2021,10,19]]}}}