{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T12:02:53Z","timestamp":1753876973551,"version":"3.41.2"},"reference-count":5,"publisher":"Oxford University Press (OUP)","issue":"3","license":[{"start":{"date-parts":[[2022,4,19]],"date-time":"2022-04-19T00:00:00Z","timestamp":1650326400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,8,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The prosthetic paravalvular leak is a rare but important complication following mitral valve replacement. Determining the location of the leak is almost always dependent on perioperative transoesophageal echocardiography and the considerable expertise of echo operators. Acoustic shadowing due to the prosthetic valve may create another important difficulty. In this report, we present a case with a paravalvular leak diagnosed 1 year after mitral valve replacement. Beating heart surgery and robotic 3D\/high-resolution camera provided to localize the direct location of leak coherent with perioperative echocardiography and precise repair. The robotic approach prevented the potential complications of aortic cross-clamp and resternotomy.<\/jats:p>","DOI":"10.1093\/icvts\/ivac071","type":"journal-article","created":{"date-parts":[[2022,4,14]],"date-time":"2022-04-14T11:16:59Z","timestamp":1649935019000},"source":"Crossref","is-referenced-by-count":0,"title":["Robotic-assisted beating heart surgery provides precise repair of periprosthetic mitral valvular leak"],"prefix":"10.1093","volume":"35","author":[{"given":"Muharrem","family":"Kocyigit","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, Ac\u0131badem Mehmet Ali Ayd\u0131nlar University School of Medicine , Istanbul, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7160-6427","authenticated-orcid":false,"given":"Ahmet Umit","family":"Gullu","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Ac\u0131badem Mehmet Ali Ayd\u0131nlar University School of Medicine , Istanbul, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sahin","family":"Senay","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Ac\u0131badem Mehmet Ali Ayd\u0131nlar University School of Medicine , Istanbul, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cem","family":"Alhan","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Ac\u0131badem Mehmet Ali Ayd\u0131nlar University School of Medicine , Istanbul, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2022,4,19]]},"reference":[{"key":"2022082714194990500_ivac071-B1","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/j.ihj.2013.04.003","article-title":"Transcatheter closure of paravalvular leaks - how do I do it?","volume":"65","author":"Sivakumar","year":"2013","journal-title":"Indian Heart J"},{"key":"2022082714194990500_ivac071-B2","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1016\/S0003-4975(98)00084-8","article-title":"Accurate localization of mitral regurgitant defects using multiplane transesophageal echocardiography","volume":"65","author":"Foster","year":"1998","journal-title":"Ann Thorac Surg"},{"key":"2022082714194990500_ivac071-B3","doi-asserted-by":"crossref","first-page":"64","DOI":"10.21037\/acs.2016.08.03","article-title":"Robotic mitral valve replacement for rheumatic mitral disease","volume":"6","author":"Senay","year":"2017","journal-title":"Ann Cardiothorac Surg"},{"key":"2022082714194990500_ivac071-B4","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1111\/jocs.15160","article-title":"Robotic-assisted cardiac surgery without aortic cross-clamping: a safe alternative approach","volume":"36","author":"G\u00fcll\u00fc","year":"2021","journal-title":"J Card Surg"},{"key":"2022082714194990500_ivac071-B5","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.repc.2020.07.016","article-title":"Paravalvular leak closure: still a challenge with unpredictable results","volume":"40","author":"Galrinho","year":"2021","journal-title":"Rev Port Cardiol (Engl Ed)"}],"container-title":["Interactive CardioVascular and Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/35\/3\/ivac071\/45596967\/ivac071.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/35\/3\/ivac071\/45596967\/ivac071.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,27]],"date-time":"2022-08-27T14:20:01Z","timestamp":1661610001000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/icvts\/article\/doi\/10.1093\/icvts\/ivac071\/6570177"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,19]]},"references-count":5,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,8,3]]}},"URL":"https:\/\/doi.org\/10.1093\/icvts\/ivac071","relation":{},"ISSN":["1569-9293","1569-9285"],"issn-type":[{"type":"print","value":"1569-9293"},{"type":"electronic","value":"1569-9285"}],"subject":[],"published-other":{"date-parts":[[2022,9,1]]},"published":{"date-parts":[[2022,4,19]]},"article-number":"ivac071"}}