{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T16:56:00Z","timestamp":1783702560551,"version":"3.55.0"},"reference-count":3,"publisher":"Oxford University Press (OUP)","issue":"3","license":[{"start":{"date-parts":[[2024,3,18]],"date-time":"2024-03-18T00:00:00Z","timestamp":1710720000000},"content-version":"vor","delay-in-days":17,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"JSPS KAKENHI","award":["21K08828"],"award-info":[{"award-number":["21K08828"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,3,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Computational fluid dynamics was performed to simulate haemodynamics of type B aortic dissection complicated by mesenteric malperfusion caused by dynamic obstruction in a 70-year-old man. Streamline analysis showed disappearance of antegrade flow in the false lumen of the descending aorta and attenuation of intermittent flap-induced disruption of visceral vessel perfusion after entry coverage. Quantitative analysis showed endovascular repair increased perfusion volume of the coeliac artery and superior mesenteric artery by 55.6% and 77.4%, respectively. Entry closure with thoracic endovascular prosthesis improved mesenteric malperfusion by attenuating the intermittent flap-induced perfusion disruption.<\/jats:p>","DOI":"10.1093\/icvts\/ivae047","type":"journal-article","created":{"date-parts":[[2024,3,18]],"date-time":"2024-03-18T22:10:17Z","timestamp":1710799817000},"source":"Crossref","is-referenced-by-count":2,"title":["Thoracic endovascular aortic repair for acute aortic dissection complicated by mesenteric malperfusion: an evaluation by computational fluid dynamics"],"prefix":"10.1093","volume":"38","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2618-6934","authenticated-orcid":false,"given":"Naoyuki","family":"Kimura","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University , Saitama,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuta","family":"Imada","sequence":"additional","affiliation":[{"name":"Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology , Nagoya,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daijiro","family":"Hori","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University , Saitama,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masanori","family":"Nakamura","sequence":"additional","affiliation":[{"name":"Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology , Nagoya,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2024,3,18]]},"reference":[{"key":"2025062416162599300_ivae047-B1","doi-asserted-by":"crossref","first-page":"e2961","DOI":"10.1002\/cnm.2961","article-title":"Flow pattern analysis in type B aortic dissection patients after stent-grafting repair: comparison between complete and incomplete false lumen thrombosis","volume":"34","author":"Naim","year":"2018","journal-title":"Int J Numer Method Biomed"},{"key":"2025062416162599300_ivae047-B2","doi-asserted-by":"crossref","first-page":"35S","DOI":"10.1016\/j.jvs.2012.07.061","article-title":"Initial findings and potential applicability of computational simulation of the aorta in acute type B dissection","volume":"57","author":"Cheng","year":"2013","journal-title":"J Vasc Surg"},{"key":"2025062416162599300_ivae047-B3","doi-asserted-by":"crossref","first-page":"1756","DOI":"10.1016\/j.jtcvs.2014.06.065","article-title":"Computational analysis to predict false-lumen perfusion and outcome of type B aortic dissection","volume":"148","author":"D'Ancona","year":"2014","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["Interdisciplinary CardioVascular and Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/icvts\/advance-article-pdf\/doi\/10.1093\/icvts\/ivae047\/57008101\/ivae047.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/38\/3\/ivae047\/58243089\/ivae047.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/38\/3\/ivae047\/58243089\/ivae047.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,24]],"date-time":"2025-06-24T20:16:31Z","timestamp":1750796191000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/icvts\/article\/doi\/10.1093\/icvts\/ivae047\/7631284"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,1]]},"references-count":3,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,3,5]]}},"URL":"https:\/\/doi.org\/10.1093\/icvts\/ivae047","relation":{},"ISSN":["2753-670X"],"issn-type":[{"value":"2753-670X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,3,1]]},"published":{"date-parts":[[2024,3,1]]},"article-number":"ivae047"}}