{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T22:26:31Z","timestamp":1793831191400,"version":"4.6.1"},"reference-count":24,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[2024,7,12]],"date-time":"2024-07-12T00:00:00Z","timestamp":1720742400000},"content-version":"vor","delay-in-days":11,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,7,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p\/>\n               <jats:sec>\n                  <jats:title>OBJECTIVES<\/jats:title>\n                  <jats:p>The Tri-Ad Adams tricuspid annuloplasty ring is a recent innovative prosthesis characterized by a semi-rigid central component and fully flexible extremities. The goal of this study was to assess the short-term and mid-term results following implantation of the Tri-Ad Adams ring.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>METHODS<\/jats:title>\n                  <jats:p>A retrospective analysis was conducted on patients who underwent tricuspid annuloplasty using the Tri-Ad Adams ring between August 2016 and October 2021.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>RESULTS<\/jats:title>\n                  <jats:p>Our study enrolled a total of 248 participants. The median age was 64.0 (interquartile range: 56.0\u201371.5) years. The median EuroSCORE II was 4.3% (2.7\u20137.5%), with 37 patients (14.9%) having a history of cardiac operations. Tricuspid regurgitation of grade 2\u20133 was observed in 63.7% of cases, and the median tricuspid annular diameter was 3.3 (2.8\u20133.6) cm. Concurrent procedures included mitral valve replacement (n\u2009=\u2009160, 64.5%), mitral valve repair (n\u2009=\u200975, 30.2%), aortic valve replacement (n\u2009=\u200972, 29.0%) and the maze procedure (n\u2009=\u2009170, 68.5%). Immediate postoperative tricuspid regurgitation\u2265moderate was present in 1 patient (0.4%). Early death occurred in 14 patients (5.6%). Major complications included low cardiac output syndrome (n\u2009=\u200918, 0.3%), acute kidney injury (n\u2009=\u200914, 5.6%) and permanent pacemaker placement (n\u2009=\u200915, 6.0%). According to the Kaplan\u2013Meier analysis, the 4-year rates of freedom from overall mortality and moderate-to-severe tricuspid regurgitation were 96.9% and 91.6%, respectively. There were no incidents of tricuspid valve reoperations, ring detachment or significant tricuspid stenosis (trans-tricuspid valve gradient\u2009\u2265\u20095\u2009mmHg).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>CONCLUSIONS<\/jats:title>\n                  <jats:p>Tricuspid annuloplasty utilizing the Tri-Ad Adams ring demonstrated favourable outcomes in both the early and midterm periods. Further studies are warranted to confirm the long-term results.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/icvts\/ivae131","type":"journal-article","created":{"date-parts":[[2024,7,12]],"date-time":"2024-07-12T16:48:00Z","timestamp":1720802880000},"source":"Crossref","is-referenced-by-count":1,"title":["Mid-term outcomes of tricuspid annuloplasty using the Tri-Ad Adams tricuspid annuloplasty ring"],"prefix":"10.1093","volume":"39","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0606-4067","authenticated-orcid":false,"given":"Heemoon","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, Bucheon Sejong Hospital , Bucheon, Gyeonggi-do, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jihoon","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, Kangnam Sacred Heart Hospital, Hallym University Medical Center, Hallym University College of Medicine , Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji-Hyun","family":"Jung","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Internal Medicine, Bucheon Sejong Hospital , Bucheon, Gyeonggi-do, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7008-054X","authenticated-orcid":false,"given":"Jae Suk","family":"Yoo","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular Surgery, Bucheon Sejong Hospital , Bucheon, Gyeonggi-do, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2024,7,12]]},"reference":[{"key":"2024072522441300700_ivae131-B1","first-page":"555","article-title":"[Selective, adjustable and permanent annuloplasty. An original technic for the treatment of tricuspid insufficiency]","volume":"25","author":"De Vega","year":"1972","journal-title":"Rev Esp Cardiol"},{"key":"2024072522441300700_ivae131-B2","doi-asserted-by":"crossref","first-page":"I577","DOI":"10.1161\/CIRCULATIONAHA.105.001263","article-title":"Tricuspid valve repair with an annuloplasty ring results in improved long-term outcomes","volume":"114","author":"Tang","year":"2006","journal-title":"Circulation"},{"key":"2024072522441300700_ivae131-B3","doi-asserted-by":"crossref","first-page":"e191","DOI":"10.1016\/j.jtcvs.2019.09.060","article-title":"The influence of tricuspid annuloplasty prostheses on ovine annular geometry and kinematics","volume":"161","author":"Malinowski","year":"2021","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2024072522441300700_ivae131-B4","doi-asserted-by":"crossref","first-page":"3087","DOI":"10.21037\/jtd.2016.11.97","article-title":"Comparison of outcomes of tricuspid annuloplasty with 3d-rigid versus flexible prosthetic ring for functional tricuspid regurgitation secondary to rheumatic mitral valve disease","volume":"8","author":"Wang","year":"2016","journal-title":"J Thorac Dis"},{"key":"2024072522441300700_ivae131-B5","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1016\/j.jtcvs.2011.06.019","article-title":"Increased risk of dehiscence after tricuspid valve repair with rigid annuloplasty rings","volume":"143","author":"Pfannmuller","year":"2012","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2024072522441300700_ivae131-B6","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1093\/icvts\/ivw047","article-title":"Flexible band versus rigid ring annuloplasty for functional tricuspid regurgitation: two different patterns of right heart reverse remodelling","volume":"23","author":"Gatti","year":"2016","journal-title":"Interact CardioVasc Thorac Surg"},{"key":"2024072522441300700_ivae131-B7","doi-asserted-by":"crossref","first-page":"e13","DOI":"10.4081\/hi.2010.e13","article-title":"Flexible band versus rigid ring annuloplasty for functional tricuspid regurgitation","volume":"5","author":"Izutani","year":"2010","journal-title":"Heart Int"},{"key":"2024072522441300700_ivae131-B8","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1093\/icvts\/ivt363","article-title":"Is a rigid tricuspid annuloplasty ring superior to a flexible band when correcting secondary tricuspid regurgitation?","volume":"17","author":"Zhu","year":"2013","journal-title":"Interact CardioVasc Thorac Surg"},{"key":"2024072522441300700_ivae131-B9","doi-asserted-by":"crossref","first-page":"S71","DOI":"10.1016\/j.jtcvs.2011.11.015","article-title":"Rationale and initial experience with the tri-ad adams tricuspid annuloplasty ring","volume":"143","author":"Milla","year":"2012","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2024072522441300700_ivae131-B10","doi-asserted-by":"crossref","first-page":"92","DOI":"10.5090\/kjtcs.2018.51.2.92","article-title":"Early clinical outcomes of tricuspid valve repair with a tri-ad annuloplasty ring in comparison with the outcomes using an mc(3) ring","volume":"51","author":"Jung","year":"2018","journal-title":"Korean J Thorac Cardiovasc Surg"},{"key":"2024072522441300700_ivae131-B11","doi-asserted-by":"crossref","first-page":"42","DOI":"10.5090\/jcs.22.094","article-title":"Surgical outcomes of cardiac myxoma resection through right mini-thoracotomy","volume":"56","author":"Shin","year":"2023","journal-title":"J Chest Surg"},{"key":"2024072522441300700_ivae131-B12","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1016\/S0894-7317(03)00335-3","article-title":"Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and doppler echocardiography","volume":"16","author":"Zoghbi","year":"2003","journal-title":"J Am Soc Echocardiogr"},{"key":"2024072522441300700_ivae131-B13","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1136\/hrt.56.1.33","article-title":"Echocardiographic measurement of the normal adult right ventricle","volume":"56","author":"Foale","year":"1986","journal-title":"Br Heart J"},{"key":"2024072522441300700_ivae131-B14","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.echo.2008.11.029","article-title":"Echocardiographic assessment of valve stenosis: EAE\/ASE recommendations for clinical practice","volume":"22","author":"Baumgartner","year":"2009","journal-title":"J Am Soc Echocardiogr"},{"key":"2024072522441300700_ivae131-B15","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1080\/01621459.1999.10474144","article-title":"A proportional hazards model for the subdistribution of a competing risk","volume":"94","author":"Fine","year":"1999","journal-title":"J Am Stat Assoc"},{"key":"2024072522441300700_ivae131-B16","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1161\/CIRCULATIONAHA.106.611889","article-title":"Geometric determinants of functional tricuspid regurgitation: insights from 3-dimensional echocardiography","volume":"114","author":"Ton-Nu","year":"2006","journal-title":"Circulation"},{"key":"2024072522441300700_ivae131-B17","doi-asserted-by":"crossref","first-page":"1645","DOI":"10.1253\/circj.CJ-08-0237","article-title":"Right ventricular remodeling and dysfunction with subsequent annular dilatation and tethering as a mechanism of isolated tricuspid regurgitation","volume":"72","author":"Seo","year":"2008","journal-title":"Circ J"},{"key":"2024072522441300700_ivae131-B18","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1510\/icvts.2007.156786","article-title":"Tricuspid valve annuloplasty with a flexible prosthetic band","volume":"6","author":"Gatti","year":"2007","journal-title":"Interact CardioVasc Thorac Surg"},{"key":"2024072522441300700_ivae131-B19","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1253\/circj.CJ-09-0845","article-title":"Outcomes following use of a modified duran ring tricuspid valve reconstruction procedure for secondary tricuspid regurgitation","volume":"74","author":"Jung","year":"2010","journal-title":"Circ J"},{"key":"2024072522441300700_ivae131-B20","doi-asserted-by":"crossref","first-page":"1493","DOI":"10.1016\/j.athoracsur.2020.09.038","article-title":"Long-term outcomes of tricuspid valve repair: the influence of the annuloplasty prosthesis","volume":"112","author":"Algarni","year":"2021","journal-title":"Ann Thorac Surg"},{"key":"2024072522441300700_ivae131-B21","doi-asserted-by":"crossref","first-page":"194","DOI":"10.21037\/acs.2017.05.05","article-title":"Flexible band versus rigid ring annuloplasty for tricuspid regurgitation: a systematic review and meta-analysis","volume":"6","author":"Wang","year":"2017","journal-title":"Ann Cardiothorac Surg"},{"key":"2024072522441300700_ivae131-B22","doi-asserted-by":"crossref","first-page":"56","DOI":"10.5090\/jcs.22.077","article-title":"Chordae tendineae approximation technique for severe tricuspid regurgitation with severe leaflet tethering using a totally endoscopic beating-heart strategy: a case report","volume":"56","author":"Jang","year":"2023","journal-title":"J Chest Surg"},{"key":"2024072522441300700_ivae131-B23","doi-asserted-by":"crossref","first-page":"2004","DOI":"10.1016\/j.athoracsur.2020.07.044","article-title":"Impact of different annuloplasty methods for tricuspid regurgitation: a network meta-analysis","volume":"111","author":"Yokoyama","year":"2021","journal-title":"Ann Thorac Surg"},{"key":"2024072522441300700_ivae131-B24","article-title":"Suture tie-down forces and cyclic contractile forces after undersized tricuspid annuloplasty using a Tri-Ad Adams tricuspid annuloplasty ring in an ovine model","volume":"37","author":"Cho","year":"2023","journal-title":"Interdiscip Cardiovasc Thorac Surg"}],"container-title":["Interdisciplinary CardioVascular and Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/icvts\/advance-article-pdf\/doi\/10.1093\/icvts\/ivae131\/58530562\/ivae131.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/39\/1\/ivae131\/58653456\/ivae131.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/39\/1\/ivae131\/58653456\/ivae131.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,25]],"date-time":"2024-07-25T23:24:17Z","timestamp":1721949857000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/icvts\/article\/doi\/10.1093\/icvts\/ivae131\/7712946"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,7,3]]}},"URL":"https:\/\/doi.org\/10.1093\/icvts\/ivae131","relation":{},"ISSN":["2753-670X"],"issn-type":[{"value":"2753-670X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,7]]},"published":{"date-parts":[[2024,7]]},"article-number":"ivae131"}}