{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,3]],"date-time":"2025-12-03T07:21:04Z","timestamp":1764746464742,"version":"3.46.0"},"reference-count":39,"publisher":"Oxford University Press (OUP)","issue":"10","license":[{"start":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T00:00:00Z","timestamp":1760140800000},"content-version":"vor","delay-in-days":10,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"name":"German Federal Ministry of Education and Research","award":["03VP08500"],"award-info":[{"award-number":["03VP08500"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,10,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>Left ventricular assist devices are part of the foundations of mechanical circulatory support. As such devices evolve in technology, so does their implantation techniques, becoming less invasive. We developed a novel blood-guiding accessory for less invasive implantation, redirecting the blood intracardially into the ascending aorta through a transaortic outflow.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Ten healthy female swine (German Landrace, 104.4\u2009\u00b1\u200913.0 kg) underwent epicardial echocardiography before and after left ventricular assist device implantation. Cardiac geometry, aortic valve function, and outflow positioning were assessed before and after implantation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Epicardial echocardiography revealed sufficient biventricular unloading after device implantation. The end-diastolic and end-systolic left ventricular diameters decreased by 16% and 20%, respectively. Retrograde unloading was displayed by smaller diameters in left and right atria at 22% and 25%, respectively. At baseline, 1 animal presented mild aortic regurgitation, unchanged under mechanical support, whereas 1 developed mild de novo insufficiency. The outflow graft was either well centred within the aortic valve (n\u2009=\u20093) or between 2 cusps.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>A left ventricular assist device with the accessory allowed sufficient ventricular unloading, preserving biventricular function. Although the outflow graft was well centred within the aortic valve in only 30% of the cases, no relevant aortic regurgitation was found in the acute setting. Chronic testing in larger samples is required to analyse results in long term.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/icvts\/ivaf168","type":"journal-article","created":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T12:01:09Z","timestamp":1760097669000},"source":"Crossref","is-referenced-by-count":0,"title":["Echocardiographic Assessment of a Novel Blood-guiding Accessory for Left Ventricular Assist Devices in Swine"],"prefix":"10.1093","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3183-1504","authenticated-orcid":false,"given":"Michelle Costa","family":"Galbas","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, Medical Center\u2014University of Freiburg, Faculty of Medicine, University of Freiburg , 79106 Freiburg im Breisgau,","place":["Germany"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Florian","family":"Meissner","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Medical Center\u2014University of Freiburg, Faculty of Medicine, University of Freiburg , 79106 Freiburg im Breisgau,","place":["Germany"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hendrik","family":"Straky","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Medical Center\u2014University of Freiburg, Faculty of Medicine, University of Freiburg , 79106 Freiburg im Breisgau,","place":["Germany"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johanna","family":"Reuter","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Medical Center\u2014University of Freiburg, Faculty of Medicine, University of Freiburg , 79106 Freiburg im Breisgau,","place":["Germany"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marius","family":"Schimmel","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Medical Center\u2014University of Freiburg, Faculty of Medicine, University of Freiburg , 79106 Freiburg im Breisgau,","place":["Germany"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Czerny","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Medical Center\u2014University of Freiburg, Faculty of Medicine, University of Freiburg , 79106 Freiburg im Breisgau,","place":["Germany"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wolfgang","family":"Bothe","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Medical Center\u2014University of Freiburg, Faculty of Medicine, University of Freiburg , 79106 Freiburg im Breisgau,","place":["Germany"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2025,10,11]]},"reference":[{"key":"2025120302165710900_ivaf168-B1","doi-asserted-by":"crossref","first-page":"S1688","DOI":"10.21037\/jtd.2018.05.205","article-title":"The evolution of mechanical circulatory support (MCS): a new wave of developments in MCS and heart failure treatment","volume":"10","author":"Chatterjee","year":"2018","journal-title":"J Thorac Dis."},{"key":"2025120302165710900_ivaf168-B2","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1056\/NEJMoa012175","article-title":"Long-term use of a left ventricular assist device for end-stage heart failure","volume":"345","author":"Rose","year":"2001","journal-title":"N Engl J Med"},{"key":"2025120302165710900_ivaf168-B3","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1056\/NEJMoa067758","article-title":"Use of a continuous-flow device in patients awaiting heart transplantation","volume":"357","author":"Miller","year":"2007","journal-title":"N Engl J Med"},{"key":"2025120302165710900_ivaf168-B4","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1161\/CIRCHEARTFAILURE.109.917765","article-title":"The development of aortic insufficiency in left ventricular assist device-supported patients","volume":"3","author":"Cowger","year":"2010","journal-title":"Circ Heart Failure"},{"key":"2025120302165710900_ivaf168-B5","doi-asserted-by":"crossref","first-page":"1594","DOI":"10.1161\/CIRCRESAHA.121.318160","article-title":"Reverse remodeling with left ventricular assist devices","volume":"128","author":"Burkhoff","year":"2021","journal-title":"Circ Res"},{"key":"2025120302165710900_ivaf168-B6","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1097\/HCO.0b013e328345af13","article-title":"Left ventricular assist device unloading effects on myocardial structure and function: current status of the field and call for action","volume":"26","author":"Drakos","year":"2011","journal-title":"Curr Opin Cardiol"},{"key":"2025120302165710900_ivaf168-B7","doi-asserted-by":"crossref","first-page":"246","DOI":"10.2174\/1573403X1103150514151750","article-title":"Minimally-invasive LVAD implantation: state of the art","volume":"11","author":"Hanke","year":"2015","journal-title":"Curr Cardiol Rev"},{"key":"2025120302165710900_ivaf168-B8","doi-asserted-by":"crossref","first-page":"2010","DOI":"10.21037\/jtd-20-1492","article-title":"Minimally invasive ventricular assist device implantation","volume":"13","author":"Al-Naamani","year":"2021","journal-title":"J Thorac Dis"},{"key":"2025120302165710900_ivaf168-B9","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.hrtlng.2022.04.013","article-title":"Risk factors for post sternotomy wound complications across the patient journey: a systematised review of the literature","volume":"55","author":"Morrell Scott","year":"2022","journal-title":"Heart Lung"},{"key":"2025120302165710900_ivaf168-B10","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1111\/aor.14728","article-title":"Longitudinal cardiac dimensions in patients undergoing LVAD implantation","volume":"48","author":"Meissner","year":"2024","journal-title":"Artif Organs"},{"key":"2025120302165710900_ivaf168-B11","first-page":"220","volume-title":"Guide for the Care and Use of Laboratory Animals","author":"National Research Council (U.S.),","year":"2011","edition":"8th ed"},{"key":"2025120302165710900_ivaf168-B12","doi-asserted-by":"crossref","first-page":"e1777","DOI":"10.1002\/hsr2.1777","article-title":"A systematic methodology for epicardial and epiaortic echocardiography in swine research models","volume":"7","author":"Galbas","year":"2024","journal-title":"Health Science Reports"},{"key":"2025120302165710900_ivaf168-B13","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1016\/S0894-7317(03)00335-3","article-title":"Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and doppler echocardiography","volume":"16","author":"Zoghbi","year":"2003","journal-title":"J Am Soc Echocardiogr"},{"key":"2025120302165710900_ivaf168-B14","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s12947-023-00321-9","article-title":"Cardiac dimensions and hemodynamics in healthy juvenile Landrace swine","volume":"22","author":"Galbas","year":"2024","journal-title":"Cardiovasc Ultrasound"},{"key":"2025120302165710900_ivaf168-B15","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/j.healun.2015.10.029","article-title":"Proximal thoracic aorta dimensions after continuous-flow left ventricular assist device implantation: longitudinal changes and relation to aortic valve insufficiency","volume":"35","author":"Fine","year":"2016","journal-title":"J Heart Lung Transplant"},{"year":"2024","author":"Wickham","key":"2025120302165710900_ivaf168-B16"},{"key":"2025120302165710900_ivaf168-B17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.echo.2014.10.003","article-title":"Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging","volume":"28","author":"Lang","year":"2015","journal-title":"J Am Soc Echocardiogr"},{"key":"2025120302165710900_ivaf168-B18","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1016\/j.healun.2010.06.006","article-title":"Aortic valve pathophysiology during left ventricular assist device support","volume":"29","author":"John","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"2025120302165710900_ivaf168-B19","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1093\/ejcts\/ezv204","article-title":"Influence of aortic valve opening in patients with aortic insufficiency after left ventricular assist device implantation","volume":"49","author":"da Rocha e Silva","year":"2016","journal-title":"Eur J Cardiothorac Surg"},{"key":"2025120302165710900_ivaf168-B20","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1093\/icvts\/ivt263","article-title":"Analysis of aortic valve commissural fusion after support with continuous-flow left ventricular assist device","volume":"17","author":"Martina","year":"2013","journal-title":"Interact CardioVasc Thorac Surg"},{"key":"2025120302165710900_ivaf168-B21","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1097\/MAT.0000000000000005","article-title":"Large animal models for left ventricular assist device research and development","volume":"60","author":"Monreal","year":"2014","journal-title":"ASAIO J"},{"key":"2025120302165710900_ivaf168-B22","doi-asserted-by":"crossref","first-page":"1869","DOI":"10.1038\/s41598-024-52376-x","article-title":"Cardioaortic dimensions in German landrace pigs derived from cardiac magnetic resonance imaging","volume":"14","author":"Meissner","year":"2024","journal-title":"Sci Rep"},{"key":"2025120302165710900_ivaf168-B23","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1016\/j.healun.2015.10.037","article-title":"INTERMACS profiles and modifiers: heterogeneity of patient classification and the impact of modifiers on predicting patient outcome","volume":"35","author":"Cowger","year":"2016","journal-title":"J Heart Lung Transplant"},{"key":"2025120302165710900_ivaf168-B24","doi-asserted-by":"crossref","first-page":"e005094","DOI":"10.1161\/CIRCHEARTFAILURE.118.005094","article-title":"Optimal hemodynamics during left ventricular assist device support are associated with reduced readmission rates","volume":"12","author":"Imamura","year":"2019","journal-title":"Circ Heart Failure"},{"key":"2025120302165710900_ivaf168-B25","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1097\/01.mat.0000249502.80792.8c","article-title":"Development of \u201cPlug and Play\u201d TransApical to aorta VAD","volume":"53","author":"Wang","year":"2007","journal-title":"ASAIO J"},{"key":"2025120302165710900_ivaf168-B26","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1111\/aor.12730","article-title":"Interaction of a transapical miniaturized ventricular assist device with the left ventricle: hemodynamic evaluation and visualization in an isolated heart setup","volume":"40","author":"Granegger","year":"2016","journal-title":"Artif Organs"},{"key":"2025120302165710900_ivaf168-B27","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1097\/MAT.0000000000000038","article-title":"Early feasibility testing and engineering development of the transapical approach for the HeartWare MVAD ventricular assist system","volume":"60","author":"Tamez","year":"2014","journal-title":"ASAIO J"},{"key":"2025120302165710900_ivaf168-B28","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1016\/j.jtcvs.2011.01.011","article-title":"Transapical miniaturized ventricular assist device: design and initial testing","volume":"142","author":"Slaughter","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2025120302165710900_ivaf168-B29","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1007\/s12265-010-9216-4","article-title":"Right ventricular failure\u2014a continuing problem in patients with left ventricular assist device support","volume":"3","author":"John","year":"2010","journal-title":"J Cardiovasc Trans Res"},{"key":"2025120302165710900_ivaf168-B30","first-page":"208","article-title":"Hemodynamic ramp tests in patients with left ventricular assist devices","volume":"4","author":"Uriel","year":"2016","journal-title":"JACC: Heart Fail"},{"key":"2025120302165710900_ivaf168-B31","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1007\/s10047-018-1064-z","article-title":"The angle of the outflow graft to the aorta can affect recirculation due to aortic insufficiency under left ventricular assist device support","volume":"21","author":"Iizuka","year":"2018","journal-title":"J Artif Organs"},{"key":"2025120302165710900_ivaf168-B32","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1097\/MAT.0000000000000443","article-title":"LVAD outflow graft angle and thrombosis risk","volume":"63","author":"Aliseda","year":"2017","journal-title":"ASAIO J"},{"key":"2025120302165710900_ivaf168-B33","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.jtcvs.2011.06.010","article-title":"The impact of additional epicardial imaging to transesophageal echocardiography on intraoperative detection of residual lesions in congenital heart surgery","volume":"143","author":"Dragulescu","year":"2012","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2025120302165710900_ivaf168-B34","doi-asserted-by":"crossref","first-page":"60","DOI":"10.4103\/2211-4122.123032","article-title":"Accuracy of intraoperative epicardial echocardiography in the assessment of surgical repair of congenital heart defects confirmed","volume":"23","author":"Manvi","year":"2013","journal-title":"J Cardiovasc Echography"},{"key":"2025120302165710900_ivaf168-B35","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1111\/echo.13874","article-title":"The role of intraoperative epicardial echocardiography in pediatric cardiac surgery","volume":"35","author":"Ozturk","year":"2018","journal-title":"Echocardiography"},{"key":"2025120302165710900_ivaf168-B36","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1177\/2150135119838414","article-title":"Epicardial echocardiography in pediatric and congenital heart surgery","volume":"10","author":"Stern","year":"2019","journal-title":"World J Pediatr Congenit Heart Surg"},{"key":"2025120302165710900_ivaf168-B37","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.healun.2013.10.003","article-title":"In vivo evaluation of the HeartWare MVAD pump","volume":"33","author":"McGee","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"2025120302165710900_ivaf168-B38","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1016\/j.healun.2013.10.032","article-title":"Extended in vivo evaluation of a miniaturized axial flow pump with a novel inflow cannula for a minimal invasive implantation procedure","volume":"33","author":"Schima","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"2025120302165710900_ivaf168-B39","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1093\/icvts\/ivac012","article-title":"Impact of the HeartMate 3 continuous-flow left ventricular assist device in patients with small body size","volume":"34","author":"Tonai","year":"2022","journal-title":"Interact CardioVasc Thorac Surg"}],"container-title":["Interdisciplinary CardioVascular and Thoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/icvts\/advance-article-pdf\/doi\/10.1093\/icvts\/ivaf168\/64639673\/ivaf168.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/40\/10\/ivaf168\/64639673\/ivaf168.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/icvts\/article-pdf\/40\/10\/ivaf168\/64639673\/ivaf168.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,3]],"date-time":"2025-12-03T07:17:09Z","timestamp":1764746229000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/icvts\/article\/doi\/10.1093\/icvts\/ivaf168\/8283577"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":39,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025,10,6]]}},"URL":"https:\/\/doi.org\/10.1093\/icvts\/ivaf168","relation":{},"ISSN":["2753-670X"],"issn-type":[{"type":"electronic","value":"2753-670X"}],"subject":[],"published-other":{"date-parts":[[2025,10]]},"published":{"date-parts":[[2025,10]]},"article-number":"ivaf168"}}